WorldWideScience
1

Generation of microwaves and hard X-rays in a flash X-ray tube  

Energy Technology Data Exchange (ETDEWEB)

High interelectrode voltage peaks have been observed simultaneously with the emission of hard X-ray bursts from a flash X-ray tube. The magnitude of the voltage peaks may exceed twice the initial charging voltage. It has also been observed that the discharge emits bursts of X-and P-band microwaves radiation which are coincident with the emission of the hard X-ray bursts. The results indicate that the microwaves and X-rays have a common origin in discharge plasma movements and an acceleration model for electrons in the plasma is presented as one possible explanation of the observed phenomena.

1982-01-01

2

Miniature x-ray source  

Energy Technology Data Exchange (ETDEWEB)

A miniature x-ray source utilizing a hot filament cathode. The source has a millimeter scale size and is capable of producing broad spectrum x-ray emission over a wide range of x-ray energies. The miniature source consists of a compact vacuum tube assembly containing the hot filament cathode, an anode, a high voltage feedthru for delivering high voltage to the cathode, a getter for maintaining high vacuum, a connector for initial vacuum pump down and crimp-off, and a high voltage connection for attaching a compact high voltage cable to the high voltage feedthru. At least a portion of the vacuum tube wall is fabricated from highly x-ray transparent materials, such as sapphire, diamond, or boron nitride.

2000-01-01

3

Vacuum leak problem in low energy of pelletron  

International Nuclear Information System (INIS)

During unit wise conditioning of unit 8, the vacuum started deteriorating inside the tube after a spark. The RGA reading was taken and it was found out that residual gas inside tube was sulphur hexafluoride. A leak was detected in second tube of unit number eight in between electrode 6 to 8. Leak was sealed with the sealant. Again leak check was done and no leak was found. The tank was closed and conditioning was started again. During the same unit number eight conditioning, leak developed again followed by a spark. So the damaged tube was replaced with a new accelerator tube. During the installation time the alignment of the machine was taken care. Again leak checking was done and the tube was baked properly. The tank was closed again and this particular unit was conditioned for about four days. The maximum voltage it has attained was 1.1 ...

4

Specific features of the current-voltage characteristics of diffuse glow discharges in Ar:N2 mixtures  

British Library Electronic Table of Contents (United Kingdom)

The characteristics of diffuse glow discharges in pure argon and the Ar + 1%N2 mixture at pressures of 2?80 Torr were studied experimentally and numerically. The discharge operated in a molybdenumglass tube with an inner diameter of 2.8 cm and interelectrode distance of 75 cm. The current-voltage characteristic of the discharge and the populations of the N2(B3? g ) and N2(C3? u ) states were measured. It is shown that, at relatively low pressures (P 15 Torr), the current-voltage characteristic of a discharge in the mixture lies lower than that in pure argon. As the pressure increases, the effect of the reduction in the discha...

2010-01-01

5

Pulse source of electron and X-ray radiations of subnanosecond duration  

International Nuclear Information System (INIS)

The time and dose characteristics of the electron and X-ray radiations of a tube, connected to a subnanosecond mega volt accelerator, are measured. By the pulse of the accelerating voltage of #>=# 600 kV with duration of #approx =# 0.3 ns the tube generates approximately 5 x 10"1"2 electrons pulse. The current amplitude equals approximately 5 kA/pulse and the radiation dose-about 5 kGy/pulse. The X-ray radiation dose from the tantalum external target constitutes 0.15 Gy/pulse. The prototypes of the electron and X-ray tubes sufficiently lower volumes, opening new applications in the technique and medicine, are developed

6

Design of APhF-IH Linac for a Compact Medical Accelerator  

CERN Document Server

The design of a small injection linac for a compact medical synchrotron is discussed. The linac design is based on interdigital H-type (IH) drift-tube structure with alternative phase focusing (APhF). A high acceleration rate and an absence of magnetic lenses inside drift-tubes reduce the cost and length of APhF-IH linac in comparison with HIMAC linac based on Alvarez structure with magnet quadrupoles inside drift-tubes. To reduce effects of emittance growth, the RFQ structure is used in front of the APhF linac. In such linac layout, the current transmission of a carbon beam can reach up to 90-100%. In this report, the basic parameters of whole linac are presented, while the design of APhF structure is considered in details. Two reference designs of 4 MeV/u 200 MHz APhF linacs with different voltage distributions along the whole tank have been generated and analyzed numerically. For the first design, a ...

2003-01-01

7

Charging a Battery-Powered Device with a Fiber-Optically Connected Photonic Power System for Achieving High-Voltage Isolation  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the development and testing of a system to provide isolated power to the cathode-subsystem electronics of an x-ray tube. These components are located at the cathode potential of several hundred kilovolts, requiring a supply of power isolated from this high voltage. In this design a fiber-optically connected photonic power system (PPS) is used to recharge a lithium-ion battery pack, which will subsequently supply power to the cathode-subsystem electronics. The suitability of the commercially available JDSU PPS for this application is evaluated. The output of the ppe converter is characterized. The technical aspects of its use for charging a variety of Li-Ion batteries are discussed. Battery charge protection requirements and safety concerns are also addressed.

2008-01-01

8

Development and performance of a miniature, high-voltage thermal battery  

Science.gov (United States)

A miniature, high-voltage, thermally activated battery has been developed. This battery weighs 41 grams, occupies a volume of 16.4 cu cm, and contains two separate 500-v channels, each designed to charge a 5.25 microfarad capacitor within 300 milli-seconds and remain operational under a 640-kohm load for a minimum of 28 seconds over the temperature range from +16 to +71 C. The electrochemical system utilizes a calcium anode, LiCl-KCl molten salt electrolyte, a CaCrO4-K2CrO4 mixture as the depolarizer or active cathode material, and an iron cathode. The depolarizer and electrolyte, along with a silica binder, are formed into homogeneous pellets, and these pellets are stacked alternately with calcium-iron bimetal disks in beryllium oxide tubes to form cell stacks. The cells are activated by an iron-potassium perchlorate pyrotechnic heat source external to the BeO tubes.

1974-01-01

9

Measurement of the energy dependence of the neutron fission cross section of /sup 242/Am/sup m/  

Energy Technology Data Exchange (ETDEWEB)

Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.

1981-03-01

10

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

Energy Technology Data Exchange (ETDEWEB)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1996-01-01

11

Transmit-receive eddy current probes for circumferential cracks in heat exchanger tubes  

International Nuclear Information System (INIS)

Conventional eddy current bobbin probes are known to be ineffectual in detecting circumferential cracks in tubing. Multi-pancake and/or rotating pancake probes are required to detect circumferential cracks. It has recently been demonstrated in CANDU steam generator tubes, with deformation, ferromagnetic deposits, and copper deposits, that multi-channel probes with transmit-receive (T/R) coils are superior to those using surface impedance coils. Unlike rotating probes, the design of a new probe denoted as C3 permits fast, single-scan inspection of a full-length tube at inspection speeds comparable to conventional bobbin probes. Since 1992, the probe has been used routinely for steam generator in-service inspection at 4 CANDU plants. Defective tubes have been plugged and the units returned to service, and they continue to operate without leaks. This paper describes the basic features of T/R surface ...

1992-01-01

12

Reducing the effect of penstock pressure pulsations on hydro electric plant power system stabilizer signals  

Energy Technology Data Exchange (ETDEWEB)

A characteristic trait of Francis turbines operating at low-head is pressure pulsations that occur during certain load levels of the generator. These stem from pressure variations across the turbine due to pulsating flow in the draft-tube. This surging action of the water column is related to draft-tube geometry and flow-rate of water in the penstock. The pressure pulsations cause torque variations on the turbine and corresponding electric power pulsations. If electric power is used as a feedback signal to the Power System Stabilizer (PSS), then Mvar and terminal voltage pulsations will occur when the generator is operating in the ``rough zone``. This paper describes field test results for investigating feedforward control from the penstock, draft tube and spiral case pressure to reduce the effects of Mw pulsations on PSS output signals. This investigation involved a PSS with generator power as the ...

1993-12-01

13

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

Energy Technology Data Exchange (ETDEWEB)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that (1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; (2) approximately equal detection ...

1994-10-01

14

Study of X-ray filter and peak kilovoltage in Fuji computed radiography in regard to the detection of simulated pulmonary nodules  

International Nuclear Information System (INIS)

To determine a suitable combination of X-ray filter and tube kilovoltage for Fuji Computed Radiography (FCR), provide better detection of pulmonary nodules, and reduce patient exposure, we compared observer performance with different X-ray filters and tube voltages. Radiographs were obtained with a copper filter backed by aluminium, with a tungsten filter backed by yttrium and aluminium, and with a lead filter backed by yttrium and aluminium, at both 100 kVp and 135 kVp. Observer performance in detecting simulated lung nodules, which were placed on the posterior aspect of a chest phantom, was compared using receiver operating characteristic (ROC) techniques for each combination of the X-ray filter and tube voltage. The results of the study indicated that 1) nodule detection was superior for the images obtained with 135 kVq as compared with 100 kVp; 2) approximately equal detection ...

1994-01-01

15

XENON-POISONING COMPUTER  

Science.gov (United States)

A computer was built for use with the NRU reactor to solve the problem of Xe/sup 135/ concentrations. The effect of any changes in reactor on Xe/sup 135/ concentration can be predicted and steps taken to avoid poisoning out. An electromechanical system was used for the computer to avoid the inherent disadvantages that electronic analog computers present for problems of very long solution times. The electromechanical analog computer has a high order of reliability and contains no vaccum tubes, commutators, slip rings, relays, or aluminum electrolytic capacitors. It is insensitive to transient disturbarce. In the event of failure of components or interruption of line voltage, it will retain existing information. The computer was designed for ~ 1% accuracy in Xe/ sup 135/ concentration readings. (W.D.M.)

1958-05-01

16

STATUS OF THE DIELECTRIC WALL ACCELERATOR  

Energy Technology Data Exchange (ETDEWEB)

The dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL) uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system is capable of accelerating any charge to mass ratio particle. Applications of high gradient proton and electron versions of this accelerator will be discussed. The status of the developmental new technologies that make the compact system possible will be reviewed. These include, high gradient vacuum insulators, solid dielectric materials, photoconductive switches and compact proton sources.

2009-04-22

17

Development of ambient sampling chemi/chemical ion source with dielectric barrier discharge  

British Library Electronic Table of Contents (United Kingdom)

The development of a new configuration of chemical ionization (CI)-based ion source is presented. The ambient air containing the gaseous sample is sniffed into an enclosed ionization chamber which is of sub-ambient pressure, and is subsequently mixed with metastable species in front of the ion inlet of the mass spectrometer. Metastable helium atoms (He*) are used in this study as the primary ionizing agents and are generated from a dielectric barrier discharge (DBD) source. The DBD is powered by an AC high-voltage supply and the configuration of the electrodes is in such a way that the generated plasma is confined within the discharge tube and is not extended into the ionization chamber. The construction of the ion source is simple, and volatile compounds released from the bulky sample can...

2010-01-01

18

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

Energy Technology Data Exchange (ETDEWEB)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. ...

2001-04-01

19

Study of chest portable radiography using computed radiography. Removal effect of X-ray scatter by a copper plate  

International Nuclear Information System (INIS)

When chest radiographs are obtained using an anti-scatter grid in a mobile x-ray unit by Fuji Computed Radiography (FCR), right lung densities may differ from left lung densities owing to misalignment caused by an oblique x-ray beam. Such misalignment is considered to be caused by factors such as the shape of the bed and angle of the x-ray tube. Misalignment is especially frequent when exposure is carried out in the sitting position. Although a low-ratio grid has been reported to offer improvement, the misalignment is not completely eliminated. Therefore, we used a copper plate without a lattice feature instead of grid, and examined the results. The copper plate was found to have the ability of a grid to eliminate radiation scatter, and, furthermore, to offer the physical capabilities of a grid as determined by Carlin's new grid assessment method. Image quality was demonstrated through contrast manipulation to be equal to that obtained by grid use. Further, optimal ...

2001-04-01

20

Dimeric subunit stoichiometry of the human voltage-dependent proton channel Hv1  

UK PubMed Central (United Kingdom)

In voltage-gated Na+, K+, and Ca2+ channels, four voltage-sensor domains operate on a central pore domain in response to membrane voltage. In contrast, the voltage-gated...Full Text Available

2008-06-03

21

Application of low-dose radiation protocols in survey CT scans  

International Nuclear Information System (INIS)

Objective: To characterize the protocols with low-dose radiation in survey CT scans for localization. Methods: Eighty standard adult patients, head and body phantoms were recruited. Default protocols provided by operator's manual setting were that all the tube voltage for head, chest, abdomen and lumbar was 120 kV; the tube currents were 20,10,20 and 40 mA, respectively. Values of kV and mA in the low-dose experiments were optimized according to the device options. For chest and abdomen, the tube position were compared between default (0 degree) and 180 degree. Phantoms were scanned with above protocols, and the radiation doses were measured respectively. Paired t-test were used for comparisons of standard deviation in CT value, noise and exposure surface dose (ESD) between group with default protocols and group with optimized protocols. Results: The optimized protocols in low-dose CT survey scans were ...

2009-08-01

22

Increasing the operational safety of nuclear facilities by using special insulation parts in the containment zone  

International Nuclear Information System (INIS)

LOCA (Loss of coolant accident) resistant heat-shrinkable polymeric products are widely used for the connection of LV cables for class 1E systems inside the containment area of nuclear power plants. The paper/presentation describes the verification of a reformulated compound for these products, where certain components of the compound formulation had to be substituted. A qualification programme with this so-called reformulated compound was undertaken to proof the equivalency of the products to the products made out of the original compound. The basic elements of this requalification project were material qualification tests including accelerated aging tests according to the arrhenius method and type tests in accordance to IEEE 383, including flammability tests. The test results showed that the products made out of the reformulated compound were similar in fit, form and function to the original products. Additional tests have also proven higher application ranges for the heat-shrinkable ...

2005-06-15

23

Efficiency of ozone production by pulsed positive corona discharge in synthetic air  

International Nuclear Information System (INIS)

We have studied the efficiency of ozone production by pulsed positive corona discharge in coaxial wire-cylinder geometry at atmospheric pressure. A corona discharge was generated by short (#approx#150 ns) high voltage pulses applied between a silver coated copper wire anode and stainless steel cylinder cathode in synthetic air. A pyrex probe and Teflon tube was used for collecting discharge products and an ozone concentration was monitored outside of the discharge chamber by a non-dispersive UV absorption technique. The production of ozone was investigated as a function of energy density (10"-"4-3x10"-"1 Wh l"-"1) delivered to the discharge volume by combining the discharge frequency (0.1-10 Hz) and airflow rate (1-32 l min"-"1). From ozone concentration measurements we have evaluated the ozone production, yield and production energy cost. The ozone production yield and cost vary in the range of 15-55 g kWh"-"1 and 35-110 eV/molecule. (author)

2002-06-07

24

Compact Dielectric Wall Accelerator Development For Intensity Modulated Proton Therapy And Homeland Security Applications  

Energy Technology Data Exchange (ETDEWEB)

Compact dielectric wall (DWA) accelerator technology is being developed at the Lawrence Livermore National Laboratory. The DWA accelerator uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. Its high electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The DWA concept can be applied to accelerate charge particle beams with any charge to mass ratio and energy. Based on the DWA system, a novel compact proton therapy accelerator is being developed. This proton therapy system will produce individual pulses that can be varied in intensity, energy and spot width. The system will be capable of being sited in a conventional linac vault and provide intensity modulated rotational therapy. The status of the developmental new technologies that make the compact system possible will be reviewed. ...

2009-06-17

25

Basic study on high performance secondary battery for electric load-leveling & electric vehicle  

Energy Technology Data Exchange (ETDEWEB)

Na/S battery can have the higher energy density and higher power density than that of existing high performance secondary battery. This battery is expected to use for electric load leveling and electric vehicle. Ni/MH battery was developed in advanced countries, but it is one of the advanced technologies which are preserved in their own country. In the study on Na/S battery, properties of B{sup -}alumina electrolyte was investigated. Also the construction technologies of this test cell was established by combining tube type of B{sup -}alumina solid electrolyte with Na-, S- electrode etc. Especially of this cell, charge/discharge performance and open circuit voltage was examined. Mi/MH battery sample were tested with SBT500 system for self-discharge rate at room temp, was measured. It was found that the electrolyte and separator can be optimized to minimize the self-discharge rate. (author). refs., figs., tabs.

1993-12-01

26

A Compact Linac for Proton Therapy Based on a Dielectric Wall Accelerator  

Energy Technology Data Exchange (ETDEWEB)

A novel compact CT-guided intensity modulated proton radiotherapy (IMPT) system is described. The system is being designed to deliver fast IMPT so that larger target volumes and motion management can be accomplished. The system will be ideal for large and complex target volumes in young patients. The basis of the design is the dielectric wall accelerator (DWA) system being developed at the Lawrence Livermore National Laboratory (LLNL). The DWA uses fast switched high voltage transmission lines to generate pulsed electric fields on the inside of a high gradient insulating (HGI) acceleration tube. High electric field gradients are achieved by the use of alternating insulators and conductors and short pulse times. The system will produce individual pulses that can be varied in intensity, energy and spot width. The IMPT planning system will optimize delivery characteristics. The system will be capable of being sited in a conventional linac vault ...

2007-10-29

27

Energy saving dc-dc converter circuit  

Energy Technology Data Exchange (ETDEWEB)

An energy saving dc-dc converter circuit is disclosed having two energy efficient means which operate in tandem, an energy conserving means and a voltage doubling means. These energy efficient means are applied in combination with elements commonly found in dc-dc converter circuits, namely an ac voltage generator, a transformer for stepping up the generated ac voltage, and means for storing the converted dc voltage. The energy conserving means is connected to the dc voltage storage means. It comprises a resettable inhibit circuit which cuts off the provision of dc voltage for conversion for a predetermined interval when the output of the converter exceeds a predetermined level. The voltage doubling means is reponsive to outputs of the inhibit circuit of the energy conserving means and the ac voltage generator. It ...

1982-06-22

28

Schottky barrier and homojunction gallium arsenide solar cells  

Energy Technology Data Exchange (ETDEWEB)

New techniques were developed to construct Schottky barrier and homojunction solar cells on GaAs substrates. Schottky barrier metal-semiconductor solar cells were produced for the first time on p-type GaAs substrate using a sputter-deposition method to form the barrier. The sputter deposition of gold or gold/palladium is the key to the method since normal thermal evaporation of gold onto p-type GaAs produces ohmic contacts. The results of this investigation are consistent with the idea that sputter damage produces donor type surface states on GaAs. Barrier heights were measured for both p-type sputtered and n-type thermally evaporated diodes using current-voltage and capacitance-voltage methods. Deep-level transient spectroscopy was used to identify the trap center concentration and energy levels for both diodes in an effort to explain the relatively large dark current in the p-type sputtered diodes. Homojunction GaAs solar cells were ...

1983-01-01

29

Quality control in medical radiology using T.L.D  

Energy Technology Data Exchange (ETDEWEB)

In this work tests of quality control in beams of X rays have been carried out, at diagnostic level, of two radiological services equipments of Brazilian hospitals (Aracaju, SE). We obtained the air kerma and kerma rate values, the beams efficiency, the coherence between the luminous fields and the referring fields of irradiation and half-value layer to each equipment and set of parameters. The measures of direct form have been obtained using two ionization chambers, one cylindrical and another one with parallel plates. An optional method for accomplishment some of the tests were carried out with CaSO{sub 4}:Dy + Teflon thermoluminescent dosimeters. The values of air kerma were evaluated for three tube voltage, 40, 60 and 81 kV at 1.0 m from the focus of the equipments. For each one of the voltages three distinct current values were chosen besides a fixed value of exposition time. The results showed that the values of air ...

2006-07-01

30

Transmit-receive eddy current probes  

International Nuclear Information System (INIS)

In the last two decades, due to increased inspection demands, eddy current instrumentation has advanced from single-frequency, single-output instruments to multifrequency, computer-aided systems. This has significantly increased the scope of eddy current testing, but, unfortunately, it has also increased the cost and complexity of inspections. In addition, this approach has not always improved defect detectability or signal-to-noise. Most eddy current testing applications are still performed with impedance probes, which have well known limitations. However, recent research at AECL has led to improved eddy current inspections through the design and development of transmit-receive (T/R) probes. T/R eddy current probes, with laterally displaced transmit and receive coils, present a number of advantages over impedance probes. They have improved signal-to-noise ratio in the presence of variable lift-off compared to impedance probes. They have strong directional properties, permitting probe ...

1997-10-27

31

Multislice spiral CT (MSCT) in pediatric radiology: dose reduction for chest and abdomen examinations  

International Nuclear Information System (INIS)

The advent of multislice spiral CT (MSCT) technique has led to new aspects of dose reduction, especially for the dedicated use of MSCT in children. Optimizing pediatric MSCT protocols according to the clinical problem allows reduction of radiation exposure to a minimum without loss of diagnostic quality. The different parameters that influence the degree of dose reduction, like tube current-time product (mAs), tube voltage (kV), collimation and pitch, are discussed in context with previously published data and our own experience in nearly 200 pediatric CT examinations. In our department, the effective mAs is calculated for a pediatric chest MSCT by multiplication of the body weight in kilogram with a factor of 1 to 1.5 and for a pediatric abdominal MSCT by multiplication with a factor of 2 to 2.5. To calculate the equivalent effective dose for a contrast media-enhanced 80 kV protocol, the effective mAs of the 120 kV ...

2004-07-01

32

Tests of Turbulators for Fire-Tube Boilers.  

Science.gov (United States)

... Originator-supplied keywords include: Turbulators, Heat transfer augmentation, Enhancement, Fire tube boilers. (Author). ...

1982-10-01

33

ELECTRON ATTACHMENT OF SEF6  

Science.gov (United States)

... attachment tube which is sketched in Fig. 1. It is mounted inside a cylindrical evacuated tube. A beam of thermal electrons ...

1961-06-20

34

Diaphragm Rupture Effects on an Expanding Flow in a Tube.  

Science.gov (United States)

... The fundamental problem of diaphragm rupture was studied experimentally to determine the effects on an expanding flow in an evacuated tube. ...

1972-08-01

35

Steam generator tube denting-criteria for tube plugging  

International Nuclear Information System (INIS)

When steam generator tube denting was identified, steps were taken to retard the rate of corrosion and to develop corrective measures if possible. Techniques were developed to determine the exact shapes of the tubes, and procedures were devised to analyze resulting strain and operating stresses. Tube plugging criteria were established, and in twelve years of operation, there has been only one instance of a forced outage due to a tube leak.

36

State-of-the-art technology for production of seamless tubes in zirconium and titanium alloys  

International Nuclear Information System (INIS)

Zircaloy fabrication plant manufactures all the necessary Zr-2 components like fuel canning tubes, calandria tubes and other rod and sheet products. This plant is having a capacity of producing about 4 lakh nos. of PHWR fuel tubes per annum. These tubes are seamless, thin walled with close dimensional tolerances and stringent mechanical properties. The plant has established all the facilities required to produce these tubes with required quality.

37

Loading of wellbores with explosives  

Energy Technology Data Exchange (ETDEWEB)

Bags of explosive are loaded rapidly into deep wellbores by suspending a rigid positioning tube partway into the wellbore, and loading the bags into the tube, the bags being prevented from dropping through the open bottom end of the tube by a cord attached to the lowermost bag and secured at the upper end of the tube when the tube-suspending cable is in tension by a cordsecuring/releasing means, E.G., a pivotable bar having a hook on one end. When the bag-laden tube is lowered to the bottom of the wellbore, or to a column of bags previously placed therein, the tension on the cable is relaxed and the cord is released, allowing the positioning tube thereafter to be raised to the surface for re-use, leaving the cord and bags in the wellbore. Freedom of the bag-supporting cord to move with respect to the positioning tube ...

1983-04-26

38

The opening of the two pores of the Hv1 voltage-gated proton channel is tuned by cooperativity  

UK PubMed Central (United Kingdom)

SUMMARYIn voltage-gated sodium, potassium, and calcium channels the functions of ion conduction and voltage sensing are performed by two distinct structural units: the pore domain...Full Text Available

2010-01-01

39

Induced voltage in a shared corridor  

Energy Technology Data Exchange (ETDEWEB)

The induction of voltages on pipelines and railroad signal wires can be a problem when high-voltage transmission lines share the right of way. A handbook and two computer programs provide the analytic tools for utilities to avoid the problem.

1983-10-01

40

Rapid and precise measurement of flatband voltage  

Science.gov (United States)

The paper outlines the design, principles of operation, and calibration of a five-IC network intended to give a rapid, precise, and automatic determination of the flatband voltage of MOS capacitors. The basic principle of measurement is to compare the analog output voltage of a capacitance meter - which is directly proportional to the capacitance being measured - with a preset or dialed-in voltage proportional to the calculated flatband capacitance by means of a comparator circuit. The bias to the MOS capacitor supplied through the capacitance meter is provided by a ramp voltage going from a negative toward a positive voltage level and vice versa. The network employs two monostable multivibrators for reading and recording the flatband voltage and for resetting the initial conditions and restarting the ramp. The flatband voltage can be held ...

1976-05-01

41

High voltage to complaints; Hoeyspent til besvaer  

Energy Technology Data Exchange (ETDEWEB)

Power supply to Bergen has created headaches. Many will not have the land-based high-voltage wire. But the alternatives are costly and will delay the line by many years. (AG)

2010-07-01

42

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

Energy Technology Data Exchange (ETDEWEB)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results.

1982-10-01

43

Steady-state thermal and hydraulic calculation of steam generator considering heat transfer tube lengths  

International Nuclear Information System (INIS)

The effect of heat transfer is described from heat exchange tubes of a horizontal steam generator on the distribution of primary water to the individual tubes of the tube bundle. It is shown that in a broad interval of mass flow rates and lengths of heat exchange tubes, the simplified method of calcualtion, i.e., calculation of the distribution of primary water into heat exchange tubes neqlecting the changes of physical properties of water along the heat exchange tubes, will yield sufficiently accurate results. (author).

1982-01-01

45

A tube inspection device. Dispositif de controle de tubes  

Energy Technology Data Exchange (ETDEWEB)

The device, aimed at non destructive control of the inner side of tubes such as steam generator tubes, is composed of a control sensor mounted on a support; the sensor head may rotate in the tube and a measuring system and signal processing allow for the exact determination of the angular position of the sensor head (application to ultrasonic or eddy current probes).

1993-05-07

47

Principles of ground relaying for high voltage and extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper is a tutorial discussion of the basic principles of ground relaying for high voltage and extra high voltage transmission lines. Three different HV configurations are considered: Long lines, lines with a weak mid-point station, and mutually-coupled lines. Application criteria for EHV circuits are also discussed, and specific setting calculations are included where appropriate.

1983-02-01

48

Optical voltage reference  

Energy Technology Data Exchange (ETDEWEB)

An optical voltage reference for providing an alternative to a battery source. The optical reference apparatus provides a temperature stable, high precision, isolated voltage reference through the use of optical isolation techniques to eliminate current and impedance coupling errors. Pulse rate frequency modulation is employed to eliminate errors in the optical transmission link while phase-lock feedback is employed to stabilize the frequency to voltage transfer function.

1992-12-31

49

Evaluation of lightning-induced overvoltages for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

This paper presents some results of lightning induced over voltages for a typical high voltage transmission line configuration. The authors developed an elaborated electromagnetic coupling between the lightning channel and characteristics and the resulting induced overvoltage. The lightning current parameters, for local data, in order to determine the occurrence severity for high voltage transmission lines. (author)

2001-07-01

53

A predictive integrated voltage regulator and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

An integrated voltage regulator and power system stabilizer based on one step ahead prediction is presented. The fixed parameter predictive control scheme is shown capable of providing consistently good voltage response and contribution to system damping over a wide range of operating conditions and system configuration. This is in contrast to the case with conventional automatic voltage regulator and power system stabilizer where performance varies widely with the operating situation and can even cause system instability. (author)

1995-04-01

56

Real-time coordination of secondary voltage control and power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

This paper is devoted to the coordination of secondary voltage control and adaptive parameters resetting of the power system stabilizer, in order to increase stability, margins in real time operation. Secondary voltage control and the power system stabilizer are two control loops, which affect the same system parameter on different bases - that parameter is the voltage set-point of the automatic voltage regulator. It was found that their effects were complementary. In that way, through the proper coordination of actions of these two control loops open up a wide range of possibilities for ensuring the stability of bulk power systems in real time. For the establishment of this coordination, an on-line sequential algorithm is proposed which is based on adaptive resetting of the voltage set-point of the automatic voltage regulator and the PSS parameters. The ...

2002-06-01

57

The Rab GTPase RabA4d Regulates Pollen Tube Tip Growth in Arabidopsis thaliana[W  

UK PubMed Central (United Kingdom)

During reproduction in flowering plants, pollen grains form a tube that grows in a polarized fashion through the female tissues to eventually fertilize the egg cell. These highly polarized pollen tubes...Full Text Available

2009-02-01

58

The Experimental Determination of the Thermodynamic and Hydrodynamic Mechanism of Augmented Flow Boiling in Tubes.  

Science.gov (United States)

Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...

1970-01-01

59

In service inspection for steam generator tubes  

International Nuclear Information System (INIS)

In this paper the authors show the means putting in place for examination of steam generators tubes. These means (eddy current probes, ultrasonic testing) associated with a knowledge on degradation phenomena allow mapping controlled tubes and limiting undesirable obturations.

1987-11-24

60

Secondary side concept to prevent steam generator tube corrosion  

International Nuclear Information System (INIS)

Some examples are given of design adaptations, e.g. U-bend support, tube spacer grid, flow distribution baffle, triangular tube pitch, tube-tubeplate sheet connection, which reduce the tendency to various types of corrosion (stress corrosion cracking, tube denting, tube wastage, intergranular cracking). A basic diagram of the secondary circuit is shown. Oxygen, corrosion product and impurity control in the secondary circuit is described. (E.J.). 19 figs., 6 refs.

1989-05-01

61

Large-scale absolute dent evaluation campaign  

International Nuclear Information System (INIS)

Steam generator tube denting is primarily caused by build-up of corrosion products at the tubesheet and the tube support plates. The mechanism of dent growth and the identification of tubes which should be removed from service have been studied. The practical outcome has been to prevent in-service tube leaks and to avoid unnecessary plugging of large numbers of tubes. A finite element study of tubesheet deformation (of pulled leaking tubes from reactors) was undertaken. Profilometry results for characterizing dents are given. Although several modifications have been made the high resolution profilometry system performance and the results obtained have proved satisfactory. (U.K.).

62

Graphitic nano tubes and aligned nano tubes films  

Energy Technology Data Exchange (ETDEWEB)

Carbon nano tubes are easily produced in macroscopic quantities, however their characterisation and possible applications are still rather limited. We have developed a new method to make aligned nano tube films which open new opportunities, not only for basic research but also for eventual applications. With this method the tubes can be aligned either parallel or perpendicular to the surface. We give a short review of the microscopic properties of single tubes and the bulk properties of the aligned films. (author). 24 refs., 6 figs.

1996-03-01

63

Film condensation of HCFC-22 on horizontal enhanced tubes  

Science.gov (United States)

Experiments were conducted to study the condensation heat transfer characteristics of horizontal enhanced tubes. In the current experiment, six different enhanced tubes, including 26, 40 fpi low fin tubes and four three-dimensional-fin tubes, were tested. The working fluid used in the experiment was HCFC-22. Data were presented in the form of overall heat transfer coefficient at three working pressures, namely 1.32, 1.47 and 1.62 Mpa. In addition, the condensing heat transfer coefficients for the test tubes were obtained from the Wilson plot technique.

1996-01-01

64

Contribution to the compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

An improved method to design suitable compensating schemes for extra high voltage transmission lines is presented. The technique is general and effective and will greatly facilitate the design of the optimal compensation scheme for extra high voltage transmission lines. The technique is illustrated for a typical 500 kV system. The equations developed here for voltage maxima and minima along the transmission line eliminate the need for point-to-point computation of the voltage profile. The controversy existing in the literature over the problem of making a choice between pi and tee configurations has been removed and it is established with a mathematical proof that the tee configuration requires compensating elements of lower ratings.

1987-04-01

65

Thoracoscopy in Children: Is a Chest Tube Necessary?  

UK PubMed Central (United Kingdom)

PurposeHistorically, a chest tube or drain has been left following a thoracic operation to allow drainage of air or fluid in the postoperative period. However, in...Full Text Available

2009-04-01

66

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters  

Science.gov (United States)

Fundamental study of heat transfer augmentation of tube inside surface by cascade smooth surface-turbulence promoters

1987-03-01

67

Development of technology on the material surveillance of CANDU pressure tubes  

International Nuclear Information System (INIS)

Material degradation of pressure tubes, which are the most important components in CANDU fuel channel, can only be evaluated by removing and examining them(material surveillance). This study aimed at establishment of overall evaluation technology including the evaluation of the material degradation for the integrity of pressure tubes of Wolsung units. Material tests for pressure tubes were performed as follows; (1) Evaluation on life limiting factors of pressure tubes (2) Review on leak-before-break and integrity maintenance technology of pressure tubes (3) Survey on selection criteria for tubes to be inspected and on related regulations for material surveillance (4) Analysis of material surveillance test procedure (5) Basic examinations of Wolsung unit 1 pressure tube material(TEM, texture, chemical component etc) (6) Manufacture of test ...

1997-05-21

68

Description of the ER-2 Dropwindsonde System The ... - ESPO - NASA  

Science.gov (United States)

2 illustrates the design of the launch tube, the gun barrel design of the multi-tube dispenser and integrated hardware pressure cannister. ...

69

An Optical Fiber Infrasound Sensor  

Science.gov (United States)

... We use a compliant, sealed tube helically wrapped with an optical fiber. ... 2.5 cm diameter compliant, sealed tube 10 m < length < 120 m ...

2000-09-01

70

X-ray dosimetry of TlGaSe_2 single crystals  

International Nuclear Information System (INIS)

TlGaSe_2 compound belongs to group of layered semiconductors of A"3B"3C_2"6-type. Photoelectric and optical properties of TlGaSe_2 single crystals were investigated in detail. Influence of gamma-, electron and neutron radiation on photoelectric properties of TlGaSe_2 single crystals is investigated too. The present work deals with experimental results relative to X-ray dosimetric characteristics of TlGaSe_2 crystals at 300 K. X-ray conductivity and X-ray dosimetric characteristic measurements are carried out in low load resistance regime. The source of X-ray radiation is the installation of X-ray diffraction analysis (URS-55a) with the BCV-2(Cu). Intensity of X-ray radiation (E) is regulated by measurement with current variation in tube at each given value of X-ray radiation dose E (R/min) are measured by crystal dosimeter DRGZ-02. X-ray conductivity coefficients K_#sigma# characterising X-ray sensitivity of investigated crystals are determined as the relative ...

71

High-power, high-brightness pseudospark-produced electron beam driven by improved pulse line accelerator  

Energy Technology Data Exchange (ETDEWEB)

A high power (200KV), intense current density, low emittance (71mmmrad), high brightness (8x10{sup 10}A/m rad) electron beam was generated in the 10cm long, high-voltage-resistive multi-gap hollow cathode pseudospark chamber filled with 15pa nitrogen and driven by an improved pulse line accelerator. The beam was ejected with the 1mm diameter, the 2.2KA beam current, and the 400ns pulse length, and could propagated 20cm in the drift tube. At a distance of 5cm from the anode it penetrated consecutively an acid-sensitive discoloring film and a 0.05mm-thick copper foil both stuck closely, left 0.6mm and 0.3mm holes on them, respectively. That 10 shots on an acid-sensitive film produced a hole of 1.6mm at 7cm downstream of anode showed its good repeatability. After 60 shots the pseudospark discharge chamber was disassembled and observed that almost no destructive damage traces left on the surfaces of its various electrodes and insulators. But on ...

1995-12-31

72

Gas evolution in aluminum electrolytic capacitors  

Science.gov (United States)

Gas evolution in aluminum electrolytic capacitors constitutes one of their main drawbacks in comparison to other types of capacitors lacking a liquid electrolyte. In this respect, one of the most common causes of failure shown by liquid electrolyte capacitors is electrolyte leakage through the seal or even explosions produced by internal pressure buildup. In order to prevent these hazards, some substances, known as depolarizers, are usually added to the capacitor electrolyte with the purpose of absorbing the hydrogen evolved at the cathode (1, 2). Although the gas evolution problem in electrolytic capacitors has been known for a long time, there is a lack of literature on both direct measurements of the gas evolved and assessments of the amount of depolarizer active for the hydrogen absorption process. Aluminum electrolytic capacitors of 100..mu..F and 40V nominal voltage, miniature type (diam 8 mm, height 18.5 mm), were manufactured under standard specifications. ...

1984-03-01

73

Boiling heat transfer in compact heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

Small circular and noncircular channels are representative of flow passages in compact evaporators and condensers. This paper describes results of an experimental study on heat transfer to the flow boiling of refrigerant- 12 in a small circular tube of diameter = 2.46 mm. The objective of the study was to assess the effect of channel size on the heat transfer coefficient and to obtain additional insights relative to the heat transfer mechanisms. The flow channel was made of brass and had an overall length of 0.9 m. The channel wall was electrically heated, and temperatures were measured on the channel wall and in the bulk fluid stream. Voltage taps were located at the same axial locations as the stream thermocouples to allow testing over an exit quality range of 0.21 to 0.94 and a large range of mass flux (63 to 832 kg/m{sup 2}s) and heat flux (2.5 to 59 kW/m{sup 2}). Saturation pressure was nearly constant, averaging 0.82 MPa for most of the ...

1994-12-31

74

Cracking of Alloy 800 tubing in superheated steam in a solar receiver  

Energy Technology Data Exchange (ETDEWEB)

The solar central receiver at the Barstow Pilot Plant is a once-through steam boiler consisting of vertical arrays of Alloy 800 tubes. Water/steam leaks associated with tube bends near the receiver outlet were observed after 16 service months. The leaks resulted from through-wall cracks localized in the crown of tube bends operating in the temperature range from 550 to 650/sup 0/C. Initiation occurred on the ID (steam side) of the tube and propagated transgranular through the tube wall. Cracking was axial and circumferential; in general, the circumferential cracks were more severe than the axial cracks. Thick oxide layers showed on the ID of the receiver tubes; a 25-..mu..m thick oxide layer had formed on tubing which operated at 650/sup 0/C. In addition, an enhanced oxidation layer was observed along a narrow band in the crown of the ...

1985-10-01

75

Wolsung-1 NPP - electrictal systems  

International Nuclear Information System (INIS)

... power reactors pressure tube reactors reactors THERMAL REACTORS.

1980-06-18

78

Experimental investigation for fluid flow and heat transfer in a rotating tube with twisted-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

Experimental investigation was carried out for friction factor and heat transfer coefficient in the case of a rotating tube with a twisted-tape insert for heat transfer augmentation. The data obtained were compared with existing data for a stationary tube with a twisted-tape insert. It has been observed that the enhancement in heat transfer offsets the rise in friction factor due to rotation, with respect to a plain tube under stationary conditions. A correlation has been proposed for the data obtained.

1995-04-01

80

Improvement in efficiency and savings potentials at the ''cold end'' by means of tube cleaning and cooling water filtration; Wirkungsgradverbesserung und Einsparpotentiale am ''kalten Ende'' durch Rohrreinigung und Kuehlwasserfiltration  

Energy Technology Data Exchange (ETDEWEB)

Contamination and blockages of the cooling tubes in the turbine condenser disturb the heat transfer, thereby causing power losses at the turbine and increasing the fuel demand. Corrosions cause tubing leakages which require operating downtimes and reduce the lifetime of the pipes. Tube cleaning systems and backflushing cooling water filters eliminate these problems. Nevertheless it can come to coatings in the condenser tubes, if the tube cleaning equipment does not operate optimally or if coarse dirt is entered. Under this aspect, the author of the contribution under consideration reports on these problems on the basis of practical examples. The author gives references to the optimized operation of the tube cleaning system and the cooling water filtration.

2010-07-01

81

Tube bundle for a heat exchanger  

International Nuclear Information System (INIS)

The tube bundle arrangement is suitable as reheating section of a steam generator in combination with a gas-cooled reactor. For any high-temperature section with a straightline type tube bundle, there is one inlet and one outlet collecting main; these two are arranged one opposite to the other and diametrically to the tube bundle. There are a number of lines from the inlet collecting main to the outlet collecting main; these lines are arranged axially one on top of the other and run around the tube bundle helically several times. (GL) 891 GL/GL 892 MB.

82

Steam generator tube performance  

International Nuclear Information System (INIS)

A review of the performance of steam generator tubes in 116 water-cooled nuclear power reactors showed that tubes were plugged at 54 (46 percent) of the reactors. The number of tubes removed from service decreased from 4 692 (0.30 percent) in 1981 to 3 222 (0.20 percent) in 1982. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that have used only volatile treatment, with or without condensate demineralization.

2005-10-27

83

Control Rod Ejection Accident while Using 6- and 8-Tube IRT-4M Fuel Assemblies in WWR-SM Research Reactor Core  

Energy Technology Data Exchange (ETDEWEB)

The WWR-SM reactor at the Institute of Nuclear Physics of the Academy of Sciences (INP AS) in Uzbekistan was converted to 6-tube IRT-4M LEU (19.7%) fuel in 2009. Presently, INP intends to also use IRT-4M 8-tube FA, and a safety analysis for these 'mixed' (8-tube and 6-tube FA) cores is required by the regulatory authorities. This paper presents results of control rod ejection transient analysis for these mixed cores

2011-07-01

84

Analysis of a bayonet tube heat exchanger  

Energy Technology Data Exchange (ETDEWEB)

This paper details the design, construction and testing of a bayonet tube heat exchanger for use in the process industry and potentially as part of an externally fired combined cycle. Detailed analysis of the system has been undertaken, in particular on the tube side. The data is reported in terms of temperature, pressure, heat gain and heat exchanger effectiveness, over a range of Reynolds numbers and shell side mixture ratios. Much of the heat gained by the tubes is in the annular flow of the bayonet tube. Overall the effectiveness of this system could exceed 70%. (Author)

2001-01-01

85

The effects of high voltage transmission lines on the health of adjacent resident populations.  

UK PubMed Central (United Kingdom)

A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant...Full Text Available

1984-01-01

86

Tarantula Huwentoxin-IV Inhibits Neuronal Sodium Channels by Binding to Receptor Site 4 and Trapping the Domain II Voltage Sensor in the Closed Configuration*S?  

UK PubMed Central (United Kingdom)

Peptide toxins with high affinity, divergent pharmacological functions, and isoform-specific selectivity are powerful tools for investigating the structure-function relationships of voltage-gated...Full Text Available

2008-10-03

87

Sensitivity limits for voltage control of P2Y receptor-evoked Ca2+ mobilization in the rat megakaryocyte  

UK PubMed Central (United Kingdom)

G-protein-coupled receptor signalling has been suggested to be voltage dependent in a number of cell types; however, the limits of sensitivity of this potentially important phenomenon are unknown. Using...Full Text Available

2004-02-15

88

Risks of leukaemia among residents close to high voltage transmission electric lines.  

UK PubMed Central (United Kingdom)

OBJECTIVES: To reassess the risk of leukaemia associated with residential exposure near high voltage transmission electric lines of 49 kV and above in view of the recent publications. METHODS: Through...Full Text Available

1997-09-01

89

Reproductive Success of Cavity-nesting Birds Breeding under High-voltage Powerlines  

Science.gov (United States)

... biological effects of electromagnetic fields (EMFs) produced by high-voltage transmission lines have come under intense scrutiny, mostly with respect ... biological effects of electromagnetic fields (EMFs...

90

Project resumes: biological effects from electric fields associated with high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Abstracts of research projects are presented in the following areas: measurements and special facilities; cellular and subcellular studies; physiology; behavior; environmental effects; modeling, scaling and dosimetry; and high voltage direct current. (ACR)

1980-01-01

91

Oxidation of an engineered pore cysteine locks a voltage-gated K+ channel in a nonconducting state.  

UK PubMed Central (United Kingdom)

We report the use of cysteine-substituted mutants in conjunction with in situ oxidation to determine the physical proximity of a pair of engineered cysteines in the pore region of the voltage-gated...Full Text Available

1996-12-01

92

Living and Working Around High-Voltage Power Lines.  

Energy Technology Data Exchange (ETDEWEB)

This booklet presents safe practices that you should follow if your activities take you near high-voltage transmission lines. It documents information that has generally been available to the public.

1981-08-01

93

Lithium batteries with voltage compatibility with conventional systems  

Science.gov (United States)

The possibility of using lead or lead-bismuth mixed oxides as positive materials in organic electrolyte lithium cells with a working voltage similar to those of conventional systems (1.5 V) has been considered. Performances and main characteristics of this new class of lithium batteries are described.

1980-03-01

94

Effect of a Longitudinally Applied Voltage Upon the Growth of Zea mays Seedlings 1  

UK PubMed Central (United Kingdom)

The electrical parameters that affect young seedling growth were investigated. Voltages ranging from 5 to 40 volts were applied longitudinally along the mesocotyl region of 4-day old Zea mays...Full Text Available

1988-08-01

95

Detrusor overactivity is associated with downregulation of large-conductance calcium- and voltage-activated potassium channel protein  

UK PubMed Central (United Kingdom)

Large-conductance voltage- and calcium-activated potassium (BK) channels have been shown to play a role in detrusor overactivity (DO). The goal of this study was to determine whether bladder outlet...Full Text Available

2010-06-01

96

A novel CMOS charge-pump circuit with current mode control 110 mA at 2.7 V for telecommunication systems  

International Nuclear Information System (INIS)

This paper presents a novel organization of switch capacitor charge pump circuits based on voltage doubler structures. Each voltage doubler takes a DC input and outputs a doubled DC voltage. By cascading voltage doublers the output voltage increases up to 2 times. A two-phase voltage doubler and a multiphase voltage doubler structures are discussed and design considerations are presented. A simulator working in the Q-V realm was used for simplified circuit level simulation. In order to evaluate the power delivered by a charge pump, a resistive load is attached to the output of the charge pump and an equivalent capacitance is evaluated. To avoid the short circuit during switching, a clock pair generator is used to achieve multi-phase non-overlapping clock pairs. This paper also identifies optimum loading conditions for different ...

2010-04-01

97

A modular approach to DC to DC power converters  

Science.gov (United States)

A familiar power inverter circuit, combined with a ferroresonant transformer and a simple control circuit, provides the basis for an economically attractive modular family of DC to DC converters. The circuit is readily adaptable to a wide range of input voltages and single or multiple output voltages.

1974-01-01

98

Radiation hardening characterization of a VDMOS developed at CAS institute of microelectronics  

International Nuclear Information System (INIS)

Total dose irradiation effects on a VDMOS developed at Institute of Microelectronics, CAS were investigated, particularly the electric parameter changes under different bias conditions. It was found that the breakdown voltage degradation by the irradiation depended mainly on the drain bias, whereas the threshold voltage degradation depended mainly on the gate bias. Thus, an innovative and effective method to domestic VDMOS total dose ionization characterization is that threshold voltage radiation hardening characterization should be tested on gate bias condition, and the breakdown voltage radiation hardening characterization, be tested on the drain bias. (authors)

2008-08-01

99

New approach to compensation of extra high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A computer-aided design procedure has been developed for the series compensation of an extra high voltage line with a compensating network connected at one or the other end or both ends. Higher degree polynomial equations are derived in terms of compensating elements to compute the network parameters for optimum received power with constrained capacitor terminal voltage, safe line current, Ferranti voltage and transient stability. It is shown that series capacitors located at both ends provide the most effective means from the viewpoint of power transmission capability in either direction, transmission efficiency and series capacitor rating in comparison with a capacitor located at one or the other end.

1985-09-01

100

HIGH VOLTAGE BREAKDOWN STUDY. ADDENDUM: SOME ...  

Science.gov (United States)

... The nature of the vacuum breakdown mechanism presents just such a problem and the relative significance or total absence of several processes ...

1968-10-01

102

Design Guide: Designing and Building High Voltage Power ...  

Science.gov (United States)

... Aluminum electrolytic capacitors have improved through the years. They are smaller, and equivalent series resistance (ESR) is improved. ...

1988-08-01

103

DEVELOPMENT OF KSC PROGRAM FOR INVESTIGATING AND - NASA Technical ...  

Science.gov (United States)

Aluminum electrolytic capacitors, with 1043 failures, are a good example. Also, categorization by size and voltage reveals such frequencies of occurrence as ...

105

An Evaluation of the Severity of the January 1998 Ice Storm in ...  

Science.gov (United States)

... storm. There was little damage to high-voltage transmission lines and communication towers in northern New England. ...

1998-04-01

106

The grid regulator as alternative for transformers; Der Netzregler als Alternative zur Transformatorenstation  

Energy Technology Data Exchange (ETDEWEB)

Line conditioners control voltage isolated in external conductors. Changes of Stern-Delta connections involve voltage drop in a nonloaded external conductor and are therefore compensated. The payback period of a line conditioner lasts normally between one to three years, according to the investment cost for the alternative medium-sized voltage to be constructed. (GL)

2005-11-01

107

The effects of high voltage transmission lines on the health of adjacent resident populations  

Energy Technology Data Exchange (ETDEWEB)

A community health survey of 438 individuals was taken to detect health problems related to high voltage electrical transmission among an adjacent residential population. Results revealed no significant or consistent relationships between exposure to a high voltage DC power line and the perceived health problems that were measured. The sample was not, however, large enough to draw statistically significant conclusions regarding possible health effects with a very low incidence.

1984-01-01

108

Fuel ignition by high voltage capacitive discharges  

Energy Technology Data Exchange (ETDEWEB)

The study examined the possibility for fuel ignition by spark discharge caused by induction effects under high voltage transmission lines. Theoretical background information on capacitive spark discharges and fuel ignition processes is given. Laboratory experiments were conducted to test the dependence of fuel ignition on three parameters: impedance in discharge path, multiple discharges, and larger electrode shapes. The results of these tests are discussed in terms of fuel ignition possibilities under high voltage transmission lines.

1983-03-01

109

ATLAS tile calorimeter electronics upgrade  

CERN Document Server

This presentation summarizes the present upgrade R&D projects in the TileCal collaboration. One project studies the possibility to divide the drawers into smaller minidrawers to simplify maintenance. There are three different front-end projects. There are also projects dealing with high voltage and low voltage distribution, projects for developing PMT dividers, low voltage electronics, data transmission and off-detector electronics.

2011-01-01

110

A solution for solid state detector and preamplifier protection, during HV application and removal transition periods  

International Nuclear Information System (INIS)

Surface barrier detectors may be damaged, because of microplasma breakdown, in rapid application of bias voltage. The high performance FETs of very low noise preamplifiers may also be damaged by rapid changes of the bias voltage. The electronic device described permits the gradual application and removal of the bias voltage, without any influence on the power supply specification. (Auth.).

111

Operating experience with Alloy 800 SG tubing in Europe  

Energy Technology Data Exchange (ETDEWEB)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. ...

2007-07-01

112

Operating experience with Alloy 800 SG tubing in Europe  

International Nuclear Information System (INIS)

'Full text:' In Germany, Alloy 800 (high nickel austenitic stainless steel) was modified and qualified for the use as steam generator tubing by Siemens/KWU (now AREVA NP GmbH). The service reliability of Alloy 800 has been demonstrated over a long period of time. 1968 Siemens/KWU decided to use this material for the NPP Stade, which started operation in 1972. The steam generators operating with Alloy 800 tubes have now been in service for more than 30 years. Up to now no PWSCC or secondary-side SCC has been observed in the more than 285,000 tubes installed in Siemens/KWU steam generators (including RSG) in 19 PWRs in Europe. The operating experience will be shown and discussed. During the past regular SG tubing inspections using eddy current testing, a few indications were detected within the tube sheet between upper and lower tube expansion. These indications ...

2007-08-19

113

Flow induced vibration mock-up test for heat exchanger tubes of PWR steam generator  

International Nuclear Information System (INIS)

It is one of the most important subjects to estimate the flow-related stability of the heat exchanger tubes. A large scale model steam generator has been developed to verify the stability of the tubes in the Japanese PWR steam generators for the two-phase flow-induced vibration and to accumulate related technical data of thermal-hydraulic and flow-induced vibration of U-bend tube bundle. The model steam generator has 230 U-bend tubes of 46 different radius and 5 columns for each of practical diameter and material, and the anti vibration bars are inserted into each spacing between tube arrays. The freon R123 has been used as the secondary side fluid in stead of water-steam two-phase. In the test, void fraction and interfacial velocities in U-bend and straight tube-bundle are measured with bi-optical probes, and vibration responses of some selected ...

2000-10-01

114

Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition  

International Nuclear Information System (INIS)

In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well ...

2008-12-01

115

Steam generator tube performance: experience with water-cooled nuclear power reactors during 1979  

International Nuclear Information System (INIS)

The performance of steam generator tubes in water-cooled nuclear power reactors has been reviewed for 1979. Tube failures occurred at 38 of the 93 reactors surveyed. Causes of these failures and procedures designed to deal with them are described. The defect rate was twice that in 1978 but still lower than the two previous years. Methods being employed to detect defects include increasing use of multifrequency eddy-current testing and a trend to full-length inspection of all tubes. To reduce the incidence of tube failures by corrosion, plant operators are turning to full-flow condensate demineralization and more leak-resistant condenser tubes. (author).

1994-10-18

116

Research on corrosion resistance of steam generator tube  

International Nuclear Information System (INIS)

In order to improve the reliability of PWR steam generators, we have performed research to improve the tubing material and tube-support-plate configuration, based on our wide operating experience, and have developed and verified Alloy TT690 as the optimum tubing material and the BEC (Broached Egg Crate) type tube-support design. In the research, we have studied the metallurgical mechanism of the alloy to improve its corrosion resistance, evaluated corrosion susceptible region quantitatively, estimated the actual environment in a steam generator and confirmed the reliability by a model boiler test over a long period. It has been verified that the steam generator with the latest design has higher reliability with respect to the corrosion resistance of tubes. (author).

117

Preparation of reactor tube by welding a porous membrane with a non-porous ceramic tube  

Energy Technology Data Exchange (ETDEWEB)

In the course of designing a catalytic porous membrane reactor for experimental studies, both inside and outside of the non-reaction zones as well as the two ends of the membrane need to be completely sealed to ensure that there is no flow across the membrane in the non-reaction zone. Experiments show that up to 50% of the total flow across the membrane may be contributed by the axial flow along the wall of the non-reaction zones if only one side of the membrane is sealed. Another problem that cannot be solved by sealing is the capillary flow of the catalyst along the tube wall into the non-reaction zones when the catalyst is doped on the membrane. One of the best ways to avoid this axial flow of catalyst would be to use non-porous tubes in the non-reaction zones and join them with the porous membrane tube. In doing so, the cost of the membrane reactor could be reduced simply because shorter membrane ...

1994-12-31

118

Numerical simulation of fluid flow and heat transfer in a concentric tube heat exchanger  

International Nuclear Information System (INIS)

In this paper, numerical simulation of a concentric tube heat exchanger is presented to determine the convective heat transfer coefficient and friction factor in a smooth tube. Increasing the convective heat transfer coefficient can increase heat transfer rate in a concentric tube heat exchanger from a given tubular surface area. This can be achieved by using heat transfer augmentation devices. This work constitutes the initial phase of the numerical simulation of heat transfer from tubes employing augmentation devices, such as twisted tapes, wire-coil inserts, for heat transfer enhancement. A computational fluid dynamics (CFD) simulation tool was developed with CFX software and the results obtained from the simulations are validated with the empirical correlations for a smooth tube heat exchanger. The difficulties associated with the simulation of a heat exchanger augmented with ...

2003-05-28

119

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

Energy Technology Data Exchange (ETDEWEB)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-01-01

120

IGC/IGSCC and general corrosion behavior of alloy 800 as a PWR S/G tube material  

International Nuclear Information System (INIS)

Resistance of Alloy 800 as a PWR S/G tube material to IGC/IGSCC and Ni, Co release into water was evaluated as compared with Alloys 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made, including the effects of shot-peening on the distribution of the residual stress of the U-bent tubes and the susceptibility to SCC, the stabilizing elements on IGC/IGSCC, and prior oxidation on general corrosion. From the results, shot-peened Alloy 800 was estimated to be the most reliable S/G tube material among the high nickel alloys tested. In addition, the Alloy 800 tube would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti, and Nb, and the prior oxidation of the inner tube surface, respectively.

1987-03-09

121

Alloy 800 welding experience at UKAEA Springfields  

International Nuclear Information System (INIS)

Investigatins into the welding of alloy 800 at the Reactor Fuel Element Laboratories, Springfields, commenced about three years ago following an extended development programme on tube to tube plate welding of low alloy and stainless steels for the Prototype Fast Reactor. The techniques and approach developed for critical fuel element welding applications had proved equally suitable for the precision welding requirements on the much heavier sections of heat exchangers. It had been demonstrated that the same control of weld quality and profile could be achieved with consistency and the permissible range of critical parameters could be readily defined. Because of this, development work was continued to include other materials, such as alloy 800, which might be of potential use. The tungsten inert gas (T.I.G.) arc welding process is used, and the equipment, including the control system, is described. Tube to ...

122

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-11-01

123

Radio and television interference caused by corona discharges from high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1995-10-01

124

Radio and television interference caused by corona discharges from high-voltage transmission lines  

International Nuclear Information System (INIS)

Increase in power utility loads in industrialized countries, as well as developing countries, demands a higher level of transmission line voltage. Radio interference (RI) problems have been determined to be a limiting factor in selecting the size of transmission line conductors. Transmission line noise is primarily caused by corona discharges in the immediate vicinity of the conductor. It has been observed that discharges occur during both half-cycles of the applied voltage, but positive corona is usually predominant at AM radio frequencies range with practical high-voltage and extra high-voltage transmission lines. The corona radio noise effect is highly dependent upon the presence of particles on the surface of the conductor and the increase of the electrical gradient beyond the breakdown value of the air. Therefore, corona radio noise varies significantly with the weather and atmospheric conditions ...

1996-04-09

125

Observation of dust stream formation produced by low current, high voltage cathode spots  

International Nuclear Information System (INIS)

Macroparticle acceleration driven by low current, high voltage cathode spots has been investigated for potential applications ranging from micrometeoroid simulation to nanoparticle deposition/implantation. Acceleration by this process was observed to occur when nanometer and micrometer-sized particles were exposed to a high voltage pulse in the presence of a plasma discharge. The applied negative voltage pulse initiates the formation of multiple, high voltage, low current cathode spots which provide the mechanism of actual acceleration of the charged dust particles. Dust streams generated by this process were detected using laser scattering techniques. Cathode spot behavior was also documented. The particle impact craters observed at the surface of downstream witness badges were documented using scanning electron microscopy and light microscopy. The observed impacts suggest the presence of energetic ...

2004-04-01

126

Laser beam apparatus and method for analyzing solar cells  

Energy Technology Data Exchange (ETDEWEB)

A laser beam apparatus and method for analyzing, inter alia, the current versus voltage curve at the point of illumination on a solar cell and the open circuit voltage of a solar cell. The apparatus incorporates a lock-in amplifier, and a laser beam light chopper which permits the measurement of the AC current of the solar cell at an applied DC voltage at the position on the solar cell where the cell is illuminated and a feedback scheme which permits the direct scanning measurements of the open circuit voltage. The accuracy of the measurement is a function of the intensity and wavelength of the laser light with respect to the intensity and wavelength distribution of sunlight and the percentage the dark current is at the open circuit voltage to the short circuit current of the solar cell.

1980-01-01

127

High voltage transmission lines studies with the use of artificial intelligence  

Energy Technology Data Exchange (ETDEWEB)

The paper presents an alternative approach for the studies of high voltage transmission lines based on artificial intelligence and more specifically artificial neural networks (ANNs). In contrast to the existing conventional-analytical techniques and simulations which are using in the calculations empirical and/or approximating equations, this approach is based only on actual field data and actual measurements. The proposed approach is applied on high voltage transmission lines in order to calculate the lightning outages, on grounding systems in order to assess the grounding resistance and on high voltage transmission lines' polluted insulators in order to estimate the critical flashover voltage. The obtained results are very close to the actual ones for all three case studies, something which clearly implies that the ANN approach is well working and has an acceptable accuracy, constituting an ...

2009-12-15

128

High voltage cable in municipal electricity supply  

Energy Technology Data Exchange (ETDEWEB)

The author explains current developments in high voltage cable technology and subsequently describes problems inherent in its application, from the users viewpoint, in municipal electricity supply. The planning of a high voltage cable network and the selection of a specific type of cable are not only dependent on the typical properties of various cables but to a major degree also on the feasible laying technique, the power transmitted, the costs, the stellation treatment of the high voltage network, the acceptance requirement, the inductive influence from telecommunication cable, thermal influences from the environment, eventual safeguards from mechanical and chemical damage to the network, frequency of failure and surveillance and breakdown location. In conclusion, the author portrays potential developments in the fields of high and maximum voltage cable from the perspectives of today.

1980-12-22

129

Comparison between two different designs in the AC voltage measurement  

British Library Electronic Table of Contents (United Kingdom)

In this paper, a comparison is done between two different techniques in measuring the AC voltage. The first technique is the single junction thermal voltage converters (SJTVC) which consist of one thermal element (TE) which its output e.m.f. in the range of 7-12mV and the other is the new designed thermal voltage converters which consist of a number of TEs connected in parallel, series and series/parallel to increase their output e.m.f. (becomes in the range of 35-51mV). The effect of increasing the output e.m.f. is studied in this paper through evaluating the uncertainty budget and proved that its increase has a great effect on the accuracy and the uncertainty of the AC voltage measurement.

2011-01-01

130

Pre-Flight Development of the PoGOLite Pathfinder  

International Nuclear Information System (INIS)

The Polarized Gamma-ray Observer (PoGOLite) is a balloon-borne instrument that will measure gamma-ray polarization in the energy range 25-80 keV from astronomical sources such as pulsars, accretion discs and jets from active galactic nuclei. The two additional parameters provided by such observations, polarization angle and degree, will allow these objects to be studied in a new way, providing information about their emission mechanisms and geometries. The instrument measures azimuthal scattering angles of photons within a close packed array of phoswich detector cells (PDCs) based on coincident detection of Compton scattering and photoelectric absorption. Each PDC comprises three different scintillating components and combines photon detection, active collimation and bottom anticoincidence into one single unit. The three parts are viewed by a photomultiplier tube (PMT) and pulse shape discrimination is used to identify signals from dierent parts. Surrounding the ...

131

3 phase-3 wire 10kW interconnected inverter for photovoltaic power generation; Sanso sansen 10kW taiyoko hatsuden`yo keito renkei inverter  

Energy Technology Data Exchange (ETDEWEB)

Inverter introduced in this paper is intended for use in medium-capacity photovoltaic power generation systems designed for industries in general. Interconnection is carried out at a low-voltage 210V point receiving from a commercial 3 phase-3 cable 6.6kV high voltage incoming panel. So as to ensure stable extraction of power in the maximum degree from a photovoltaic power generation system that is naturally unstable, this inverter monitors voltage and power, and behaves in a fully automated way. A maximum power point tracking (MPPT) control function is provided, which measures the power level at the current operating voltage point A, changes the operating voltage to a voltage value B which is lower than the point A voltage by 3V and to a voltage value C which is higher than the point A voltage by ...

1997-10-30

132

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

British Library Electronic Table of Contents (United Kingdom)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-01-01

133

The effect of deposits on the tubes of a horizontal steam generator on its thermal-hydraulic characteristics  

Science.gov (United States)

Analytical relations are obtained for estimating how the distributions of temperature and heat flux vary along a steam-generating tube and how the steam-generator power output reduces due to formation and accumulation of deposits.

2007-12-01

134

Terminated Exploding Wire Energy Source.  

Science.gov (United States)

By placing a discharge or 'dump' tube across an exploding bridgewire load, it is possible to by-pass the electrical energy and terminate the explosion of the wire. The dump tube is triggered by a signal derived from the energy removed from the storage cap...

1965-01-01

135

Stability of Plasma Human Immunodeficiency Virus Load in VACUTAINER PPT Plasma Preparation Tubes during Overnight Shipment  

UK PubMed Central (United Kingdom)

VACUTAINER PPT plasma preparation tubes were evaluated to determine the effects of various handling and shipping conditions on plasma human immunodeficiency virus (HIV) load determinations. Plasmas...Full Text Available

2000-01-01

136

Social media - Social media, The University of York  

Wastenet

...A directory of University social media accounts, including Facebook, Twitter and YouTube facebook, twitter, blog Social media - Social media, The ... Key: Facebook, Twitter, YouTube, Blog, LinkedIn, Flickr Missed you out? If you'd like to be included on this ...

137

Safety of pull-type and introducer percutaneous endoscopic gastrostomy tubes in oncology patients: a retrospective analysis  

UK PubMed Central (United Kingdom)

BackgroundPercutaneous endoscopic gastrostomy (PEG) allows long-term tube feeding. Safety of pull-type and introducer PEG placement in oncology patients with head/neck or oesophageal...Full Text Available

138

Research and development on probe inserting method into steam generator helically coiled tubes for in-service inspection  

International Nuclear Information System (INIS)

Helically coiled tubes of steam generators (SG) in FBR are boundaries between sodium and water/steam. Therefore, to assure the integrity of tubes, it is necessary to inspect the tubes nondestructively for in service or after a sodium-water reaction accident. In order to make it possible to conduct in-service inspection of SG tubes, we have studied on eddy current probes and probe inserting methods. As for the probe inserting method, IHI designed a fluid driving type which consists of a model probe and signal cable with float balls and driven by air pressure force. Presented in this paper is the authors' report, which describes the fluid driving type as an effective method to insert an eddy current probe into helically coiled tubes. The outline of the test results is as follows: 1. It was possible to insert the probe into 65 meter length helically coiled tubes. ...

1979-01-01

139

Multiple neural tube defects in the same patient with no neurological deficit  

UK PubMed Central (United Kingdom)

Congenital deformities involving the coverings of the nervous system are called neural tube defects (NTDs). NTD can be classified as neurulation defects, which occur by stage 12, and postneurulation...Full Text Available

2010-01-01

140

Mechanistic insights from a quantitative analysis of pollen tube guidance  

UK PubMed Central (United Kingdom)

BackgroundPlant biologists have long speculated about the mechanisms that guide pollen tubes to ovules. Although there is now evidence that ovules emit a diffusible attractant, little...Full Text Available

141

Material and process improvements in condenser tubing  

Energy Technology Data Exchange (ETDEWEB)

The reliability of the surface condenser is a key factor in plant performance level and maintenance cost optimization. This is especially the case for thermal nuclear plants where condenser raw wa-ter ingress can introduce contamination into the chemically-controlled, steam/water loop potentially causing damage to sensitive equipment. Two important parameters must be taken into account when attempting to optimize the quality and the reliability of condenser tubing. They include selecting the appropriate material according to the cooling water corrosion level present. A second and equally important parameter is the manufac-turing of the tubing product itself. This paper will identify methods to optimize manufacturing processes and improve tubing quality, according to VALTIMET's 30 years of condenser welded tubing production experience. Those methods complete the core manufacturing process ...

2010-07-01

142

Lectin Binding of the Major Polar Tube Protein (PTP1) and its Role in Invasion  

Science.gov (United States)

... 2003)050[0600:LBOTMP]2.0.CO;2 Lectin Binding of the Major Polar Tube Protein (PTP1) ... PTP1. We, therefore, undertook a study ...

143

Intergranular attack or corrosion in a once-through model steam generator: Final report  

Energy Technology Data Exchange (ETDEWEB)

Faulting the feedwater for a 19-tube, model steam generator with 10 ppM of caustic once a week produced widespread shallow 25 to 75 micrometers (1 to 3 mils) intergranular attack (IGA) on alloy 600 tubes and an axial tube rupture at the steam-water interface after 4.8 years. An extensive investigation of the IGA damage found little correlation with major test variables beyond the indication that mill-annealed tubing was more susceptible to attack than stress-relieved tubing. The most likely cause of the tube rupture was caustic that concentrated to high levels in a porous scale on the tube at the liquid-vapor interface where there was a high available superheat. Nondestructive examination (NDE) eddy current probes underestimated the depth of IGA and were not sensitive to circumferential cracks less than 152 micrometers (6 mils) deep that ...

1987-07-01

144

Integrity of the tubes used in vertical and horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Statistical data on experience gained from operation of steam generators around the world are presented, problems arising in vertical and horizontal steam generators are described, and the conditions of heattransfer tubes used in them are compared.

2011-01-01

145

Inspection of PFR steam generators  

International Nuclear Information System (INIS)

The inspection of PFR evaporator tubing, superheater and reheater tubing, and tube plate examinations, are described. Ferritic steel U tubes in the evaporator have been examined by an eddy current system operating at 400 kHz using flexible rotating probes. Surface defects as shallow as 0.1 mm can be detected and sized in the range 0.1 to 0.5 mm deep. An ultrasonic method is under development for wall thickness. Special test coil probes have been developed for examination of the type 316 stainless steel superheater and reheater tubing. Crack-life defects in the bore are detectable at approximately 10% wall thickness and 20% on the outside diameter. Tube plate examinations from the tube holes, have been conducted using eddy current probes which identify surface breaking cracks in the holes. For detecting curtain cracks between ...

1976-03-09

146

Heat transfer augmentation in 3D internally finned and microfinned helical tube  

Energy Technology Data Exchange (ETDEWEB)

Experiments are performed to investigate the single-phase flow and flow-boiling heat transfer augmentation in 3D internally finned and micro-finned helical tubes. The tests for single-phase flow heat transfer augmentation are carried out in helical tubes with a curvature of 0.0663 and a length of 1.15 m, and the examined range of the Reynolds number varies from 1000 to 8500. Within the applied range of Reynolds number, compared with the smooth helical tube, the average heat transfer augmentation ratio for the two finned tubes is 71% and 103%, but associated with a flow resistance increase of 90% and 140%, respectively. A higher fin height gives a higher heat transfer rate and a larger friction flow resistance. The tests for flow-boiling heat transfer are carried out in 3D internally micro-finned helical tube with a curvature of 0.0605 and a length of 0.668 m. Compared with that in ...

2005-05-01

147

Enhanced tube inner surface heat transfer device and method  

Science.gov (United States)

An inner surface substrate of metal tubes is provided with a single layer of randomly distributed metal bodies bonded to the substrate, spaced from each other, and substantially surrounded by the substrate to form body void space.

1979-05-15

148

Endoscopic T-tube placement in the management of lye-induced esophageal perforation: Case report of a safe treatment strategy  

UK PubMed Central (United Kingdom)

Esophageal perforation is associated with a significant risk of morbidity and mortality. We report herein a case of lye-induced esophageal perforation managed successfully by employing endoscopic T-tube...Full Text Available

149

Conjugate heat transfer of a finned tube. Part B: Heat transfer augmentation and avoidance of heat transfer reversal by longitudinal vortex generators  

Energy Technology Data Exchange (ETDEWEB)

Numerical investigations of three-dimensional flow and heat transfer in a finned tube with punched longitudinal vortex generators (LVG`s) are carried out for Reynolds number of 250 and 300. Air with a Prandtl number of 0.7 is used as the fluid. The flow is both thermally and hydrodynamically developing. The LVG is a delta winglet pair (DWP) punched out of the fin and is located directly behind the tube, symmetrically separated by one tube diameter. The DWP generates longitudinal vortices in the wake of the tube, defers flow separation on the tube, deflects the main stream into the tube wake, and strong reduces the ``dead water zone.`` Heat transfer reversal is avoided by the DWP. Comparison of the span-averaged Nusselt numbers for the fin with and without DWP shows significant local heat transfer enhancement of several hundred percent in the ...

1995-08-01

150

Application of automatic inspection system to nondestructive test of heat transfer tubes of primary pressurized water cooler in the high temperature engineering test reactor. Joint research  

International Nuclear Information System (INIS)

Heat transfer tubes of a primary pressurized water cooled (PPWC) in the high temperature engineering test reactor (HTTR) form the reactor pressure boundary of the primary coolant, therefore are important from the viewpoint of safety. To establish inspection techniques for the heat transfer tubes of the PPWC, an automatic inspection system was developed. The system employs a bobbin coil probe, a rotating probe for eddy current testing (ECT) and a rotating probe for ultrasonic testing (UT). Nondestructive test of a half of the heat transfer tubes of the PPWC was carried out by the automatic inspection system during reactor shutdown period of the HTTR (about 55% in the maximum reactor power in this paper). The nondestructive test results showed that the maximum signal-to-noise ratio was 1.8 in ECT. Pattern and phase of Lissajous wave, which were obtained for the heat transfer tube of the PPWC, were ...

151

An argument for the conservative management of small traumatic pneumathoraces in populations with high prevalence of HIV and tuberculosis: an evidence-based review of the literature  

UK PubMed Central (United Kingdom)

BackgroundTraumatic pneumothoraces are common. Many are managed with tube thoracostomy. However, there is a high complication rate from chest tube placement, particularly in patients...Full Text Available

152

Substantiation of recommendations for ensuring the design service life of heat-transfer tubes used in a PGV-1000MKP steam generator  

Science.gov (United States)

We present the results obtained from tests and studies carried out on the model of tube bundles for a PGV-1000 horizontal steam generator that were conducted for experimentally substantiating the design service life of a steam generator tube bundle intended for use at new nuclear power stations equipped with a PGV-1000MKP steam generator. Measures taken to minimize the incipience and development of local corrosion damage to the heat-transfer tubes and ensure their design service life are substantiated and confirmed.

2011-03-01

153

Peripherally inserted central catheter  

Science.gov (United States)

You have a peripherally inserted central catheter (PICC). This is a tube that goes into a vein in your arm. It will help carry nutrients ...

154

Meteorological Measurement Guide  

Science.gov (United States)

... 2-22 Page 31. The mercury barometer operates on the principle of air pressure forcing the mercury column up an evacuated tube. ...

1992-01-01

155

Kinetics of salt concentration in heated crevices  

International Nuclear Information System (INIS)

In PWR steam-generators, the crevice between tube and tube-support plate tends to fill with porous deposits during operation and acts as a concentration site for chemicals in the boiler water, which may lead to corrosion of the tube and tube-support-plate. The rate of concentration, the magnitude of the concentration factor and the rate of release of solute when conditions change are important parameters for devising strategies to minimize corrosion. Values of these parameters for salt concentration have therefore been measured in a laboratory simulation of the crevice and are used to formulate a model of the concentrating process.

1985-03-01

156

Is OD peening of Alloy 800 SG tubes desirable?  

Energy Technology Data Exchange (ETDEWEB)

The shot peening of the outer surface of Alloy 800 is proposed by the steam generator supplier in order to increase the stress corrosion cracking resistance of the tubes. The benefits and drawbacks of such a treatment are evaluated, focusing on the main concern i.e. a possible enhanced tendency of stress corrosion cracking at the transition of the expanded tube-to-tubesheet joint. Stress corrosion tests as well as residual stresses measurements demonstrate no significant difference between peened and unpeened tubes at that location. The other concerns such as stability of the compressive stresses, increased risk of pitting or intergranular attack and pollution of the secondary circuit by fragmented beads appear the as minor concerns.

1992-12-31

157
158

Inelastic collisions of molecular ions in the injected ion drift tube  

International Nuclear Information System (INIS)

... energy spectra inelastic scattering ion-molecule collisions mass spectrometers

1977-07-27

159

Heat exchanger tube vibration: comparison between operating experiences and vibration analyses  

International Nuclear Information System (INIS)

Tube failures due to excessive flow-induced vibration must be avoided to assure the reliable performance of heat exchangers. Such components must be thoroughly analysed for vibration at the design stage. Several flow-induced vibration mechanisms are possible. In this paper, particular attention is given to fluidelastic instability of tube bundles subjected to liquid and two-phase cross-flow. The performance of ten operating heat exchanger components is reviewed to validate our recommended vibration analysis guidelines. Both tube failure histories and satisfactory performances are considered. The results show that a fluidelastic instability constant K=3.3 is a reasonable design criterion. (auth).

1992-12-01

161

Explosive Performance Modification by Cosolidification of ...  

Science.gov (United States)

... A booster pellet, normally Comp B, was placed in the tube and an exploding bridgewire (EBW) detonator in a plastic holder was glued in with a ...

1976-10-01

163

Dictionary of Technical Terms for Aerospace Use - S  

Science.gov (United States)

sabot: A device fitted around or in back of a projectile in a gun barrel or launching tube to support or protect the projectile or to prevent the escape of ...

164

Design of a kW, DC Magnetically Contained Electrothermal ...  

Science.gov (United States)

... magnetic containment field lines which is zero on the center line of the toroidal containment tube and increases in magnitude with ...

1988-07-01

165

Acute diaphragmatic paralysis caused by chest-tube trauma to phrenic nerve  

International Nuclear Information System (INIS)

A 3"1/_2-year-old child developed unilateral diaphragmatic paralysis after chest drain insertion. Plain chest X-ray demonstrated paravertebral positioning of the chest-tube tip, and magnetic resonance imaging revealed hematomas in the region of the chest-tube tip and the phrenic nerve fibers. The trauma to the phrenic nerve was apparently secondary to malposition of the chest tube. This is a rare complication and has been reported mainly in neonates. Radiologists should notify the treating physicians that the correct position of a chest drain tip is at least 2 cm distant from the vertebrae. (orig.)

2001-06-01

166

A horizontal steam generator for the Indian 235 MW heavy water nuclear power plants  

International Nuclear Information System (INIS)

In this paper the thermal design of a horizontal steam generator for the Indian PHWR nuclear power plant is described. The main attraction is absence of tube sheet and use of stainless steel 'U' tubes. It is emphasised that with appropriate water chemistry it is possible to use stainless steel tubes, which is many times cheaper than the Incoloy tubes used elsewhere. The design approach, applicable equation for the design and the results of computation in the form of heat transfer area and some important dimensions of the steam generator are presented.

1993-11-01

167

Transmit-receive eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

This paper describes various eddy current probes, and their performance, which were developed at the Chalk River Laboratories of Atomic Energy of Canada. Included are probes for detecting defects at tubesheet regions in heat exchanger tubes, defects at expansion-transition regions in finned tubes, and defects in ferromagnetic tubes. All of these probes can be used with conventional commercially available instruments. (author).

1987-09-01

168

Steam generator tube failures: experience with water-cooled nuclear power reactors during 1976  

International Nuclear Information System (INIS)

A survey was conducted of experience with steam generator tubes at nuclear power stations during 1976. Failures were reported at 25 out of 68 water-cooled reactors. The causes of these failures and the repair and inspection procedures designed to cope with them are summarized. Examination of the data indicates that corrosion was the major cause of steam generator tube failures. Improvements are needed in steam generator design, condenser integrity and secondary water chemistry control. (author).

1994-10-18

169

Solar collectors with tubes partially filled with porous substrates  

Energy Technology Data Exchange (ETDEWEB)

In this work, the thermal performance of a conventional collector is improved by inserting porous substrates at the inner walls of the collector tubes. The porous substrates improve the convective heat transfer coefficient between the tube wall and the fluid. This improvement is investigated numerically and its effects on the efficiency and the useful gain of the collector are evaluated. It is found that inserting the porous substrate may raise the collector efficiency considerably, especially at high values of the overall heat loss coefficient.

1999-02-01

170

Pipe crawlers  

International Nuclear Information System (INIS)

The patent concerns pipe crawlers, i.e. apparatus capable of moving along the bores of pipes and tubes. Pipe crawlers are employed for conveying inspection equipment along the bores of pipes and tubes. The pipe crawler comprises a piston and assembly system, which controls the movement of the crawler and supports the assembly centrally within the bore of the pipe or tube. (UK).

1984-11-29

171

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

Energy Technology Data Exchange (ETDEWEB)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-07-01

172

Development of Program Evaluating the Effects on the Secondary Side of Steam Generator due to Foreign Objects  

International Nuclear Information System (INIS)

When materials such as metal are into the secondary side of steam generator, they, so called foreign objects, may have influences on the integrity of the steam generator tubes. They cause the tube wear due to the relative motion between the tubes and foreign objects and the tube impact due to flow. The best way to avoid the effects is to remove all the foreign objects. However, it is not easy to remove the foreign materials thoroughly due to their condition such as the location. If the locations of the foreign materials are in the middle of tube bundle and the tube arrangement of the steam generator is the triangle type, the equipment such as FOSAR(Foreign Object Search and Retrieval) can not reach their locations. If the foreign materials stick together with the tubes or tube sheet, they can not be removed. In the case ...

2005-10-27

173

Characterization of tube support alloys  

International Nuclear Information System (INIS)

The involvement and relationship of carbon steel corrosion products in the tube denting phenomenon promoted an intensive research effort to: 1) understand, reproduce, and arrest the denting process, and 2) evaluate alternative tube support materials to provide additional corrosion resistance. The paper summarizes a corrosion testing program for the verification of type 405 stainless steel under acid or all volatile treatment conditions.

1985-03-01

174

Characterization of eddy current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the eddy-current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects.

1985-02-01

175

Characterization of Eddy Current probes used in steam generator tubes inspection  

International Nuclear Information System (INIS)

In in-service inspection of steam-generator tubes, the need for reproducibility of the measurement results and for comparison of these results over two successive inspections has led EDF to specify the main characteristics of the Eddy-Current probes and to design equipment to measure them. This equipment is presented here and the electrical and magnetic results are correlated with those obtained by testing tubes with reference defects. 5 refs.

1985-02-01

176

Centering device  

Energy Technology Data Exchange (ETDEWEB)

A centering device for casing tubings is proposed. It includes a housing, collar made of copper linings, return springs and pusher with centering pins placed in it. In order to simplify the design of the centering device it is equipped with levers installed on the pusher rod and connected by hinges to one another. The centering device assures coaxial placement of tubes over the mouth of wells and installation of butt joints during welding of tubes.

1980-03-15

177

A study on the regulatory approach of KNGR multiple failure events  

Energy Technology Data Exchange (ETDEWEB)

This project is to provide the regulatory direction of containment bypass during multiple steam generator tube failure issue for the Korean Next Generation Reactors, which is a part of major technical issues resulted from the safety regulation R and D on the KNGR. The outstanding results are as follows : the Multiple Steam Generator Tube Repture(MSGTR) event has never been occurred in the history of commercial nuclear reactor operation but single Steam Generator Tube Rupture(SGTR) event is reported to occur every two years. A probabilistic safety analysis study on MSGTR event, however, show its probability of occurrence is to be the same order as the design basis accidents such as LACA. In this regard, the ability of NPPs to cope with MSGTR event is required. Some requirements on initial and boundary conditions are suggested to be used in the analyses of NPPs during MSGTR events. The items that should be considered in ...

2001-01-15

178

Torsional responses of double-walled carbon nanotubes via molecular dynamics simulations  

Energy Technology Data Exchange (ETDEWEB)

The buckling behaviors of double-walled carbon nanotubes (DWCNTs) under torsion are investigated by using molecular dynamics (MD) simulations. The effect of length on the torsional buckling behaviors of DWCNTs is examined for the first time. The simulation results show that the DWCNTs experience gradual or simultaneous buckling deformations depending on their lengths. In addition, the effect of the inner tube in a DWCNT on its torsional buckling behavior is also examined. The presence of the inner tube triggers van der Waals (vdW) interactions between it and the outer tube and thus leads to a stiffening effect of the DWCNT against torsional deformation. Whether the ends of the inner tube are free or fixed and whether it is subject to a torque or not, the critical torque and the critical torsional angle of the outer tube are only marginally affected.

2008-11-12

179

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-15

180

The estimation of lifetime distribution of Alloy 800 steam generator tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors worldwide and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under appropriate operating conditions. In planning refurbishment of nuclear plants stations, a key concern is the longevity of existing SGs up to the 60-year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and refines its estimation based on data specific to CANDU operating conditions. The paper presents a more advanced Bayesian probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of ...

2009-10-01

181

Superphenix 1 steam generator fabrication  

Energy Technology Data Exchange (ETDEWEB)

The Superphenix 750-MW (thermal), once-throughtype steam generators are the result of over 10 years of intensive research and development. Detailed design and manufacture of the components lasted from 1977 to 1982. The main difficulties encountered during the construction of these prototype units concerned: demonstration of satisfactory high-temperature properties of Alloy 800 tubes; proven resistance of tube welds to thermal fatigue and of structures and shells to sodium/ water reaction effects; prevention of the tube bundle to flow-induced vibration; necessity of manual welding of shells to prevent hot cracking hazards related to the boron content of the steel; and welding of heat exchange tubes. None of these difficulties, however, invalidated initial major design choices, but provided a wealth of technical and technological experience and knowledge for the steam generators of the future. Plans for ...

1985-02-01

182

Research on pitting corrosion of steam generator heat transfer tubes based on acoustic emission  

International Nuclear Information System (INIS)

Corrosion of steam generator heat transfer tubes (SGHTT) is one of the important problems which affect safety operation of nuclear power plants (NPP), and the hazard of pitting corrosion of heat transfer tubes is the most serious. With an acoustic emission device, the signals during a corrosion test on SGHTT were collected and analyzed, and the corrosion points in the tubes were located accurately. The results show that pitting corrosion of heat transfer tubes has passed through three periods in its development: expansion phase, stationary phase and rapid developing phase. The corrosion damage of HTT can be found earlier with acoustic emission than any other non-destructive testing methods. Acoustic emission can be used for on-line and real-time monitoring of the safety and operation of the steam generator and has therefore a great significance. (orig.)

2010-09-01

183

Investigations on denting phenomenon in monel tubes  

International Nuclear Information System (INIS)

Denting phenomenon as experienced in PWR steam generators has been investigated in the laboratory of Monel-400 tubes and C-steel baffles combination. Isothermal corrosion tests have been carried out by exposing capsules, containing a crevice between Monel-400 tubes and C-steel plugs, in plausible corrodents at 300"0C. Results indicated that the denting phenomenon is strongly influenced by the chloride content in the solution. In addition, it is a time dependent process. Stress exerted on the tubes by the growth of corrosion product on the outside surface of C-steel plugs are enough to deform the Monel tubes. The results have been discussed on the basis of accelerated corrosion of C-steel by hydrolyzable metal chlorides. (author).

1981-05-01

184

Evaluation, testing and database generation of pitting corrosion characteristics of domestic steam generator tubing material  

Energy Technology Data Exchange (ETDEWEB)

Accumulation of Chloride and Cupric ions under the sludge on the steam generator tubing surface in the area between tube sheet and the first tube support is known to be the main reason for the pitting corrosion. In addition to those ions, oxygen, pH, temperature, heat treatment history, contests of minor elements such as C, S or Ti in the alloy are also influencing the material's the pitting corrosion resistance. a series of autoclave pitting test was conducted to evaluate the pitting corrosion characteristics of the domestically produced alloy 690 tubing material and compare with that of INCO manufactured material. 16 refs., 44 figs., 5 tabs. (Author)

1998-04-01

185

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-07-01

186

A probabilistic approach to the estimation of lifetime distribution of Alloy 800 SG tubing  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. Extensive laboratory testing and in-service experience suggest that the Alloy 800 tubing has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. In planning refurbishment of CANDU stations, a key concern is the longevity of existing SGs up to the 60 year lifetime of the refurbished plant. The paper reviews an existing methodology based on the concept of the improvement factor, and estimates it based on experimental data specific to CANDU operating conditions. The paper presents a more advanced probabilistic approach to estimate the degradation free lifetime distribution of Alloy 800 tubing, which is used to quantify the probability of degradation during the service life and to evaluate the impact of potential occurrences of degradation ...

2008-06-01

187

Stable p-channel polysilicon thin film transistors fabricated by laser doping technique  

Energy Technology Data Exchange (ETDEWEB)

In this work we present the electrical characterization of non self-aligned p-channel thin film transistors fabricated by using laser doping technique for source/drain contact formation and gate oxide deposited at room temperature by Electron Cyclotron Resonance Plasma Enhanced Chemical Vapour Deposition. These techniques are suitable for a very low temperature process for TFT fabrication. The output characteristics show a current increase at high drain voltage ('kink' effect) rather moderate, if compared to self aligned polysilicon TFTs, probably due to the gradual doping profile induced by laser doping process. After bias stress at low gate voltage and high drain voltage condition a strong reduction of kink current has been observed in the output characteristics at high drain voltage, whereas minor changes has been observed in the transfer characteristics. This behaviour is similar ...

2005-09-01

188

Stable p-channel polysilicon thin film transistors fabricated by laser doping technique  

International Nuclear Information System (INIS)

In this work we present the electrical characterization of non self-aligned p-channel thin film transistors fabricated by using laser doping technique for source/drain contact formation and gate oxide deposited at room temperature by Electron Cyclotron Resonance Plasma Enhanced Chemical Vapour Deposition. These techniques are suitable for a very low temperature process for TFT fabrication. The output characteristics show a current increase at high drain voltage ('kink' effect) rather moderate, if compared to self aligned polysilicon TFTs, probably due to the gradual doping profile induced by laser doping process. After bias stress at low gate voltage and high drain voltage condition a strong reduction of kink current has been observed in the output characteristics at high drain voltage, whereas minor changes has been observed in the transfer characteristics. This behaviour is similar to what observed in ...

2005-09-01

189

Living and Working Safely Around High-Voltage Power Lines.  

Energy Technology Data Exchange (ETDEWEB)

High-voltage transmission lines can be just as safe as the electrical wiring in the homes--or just as dangerous. The crucial factor is ourselves: they must learn to behave safely around them. This booklet is a basic safety guide for those who live and work around power lines. It deals primarily with nuisance shocks due to induced voltages, and with potential electric shock hazards from contact with high-voltage lines. References on possible long-term biological effects of transmission lines are shown. In preparing this booklet, the Bonneville Power Administration has drawn on more than 50 years of experience with high-voltage transmission. BPA operates one of the world`s largest networks of long-distance, high-voltage lines. This system has more than 400 substations and about 15,000 miles of transmission lines, almost 4,400 miles of which are operated at 500,000 volts.

2001-06-01

190

Electrical biasing and voltage contrast imaging in a focused ion beam system  

Energy Technology Data Exchange (ETDEWEB)

We present two new techniques that enhance conventional focused ion beam (FIB) system capabilities for integrated circuit (IC) analysis: in situ electrical biasing and voltage contrast imaging. We have used in situ electrical biasing to enable a number of advanced failure analysis applications including (1) real time evaluation of device electrical behavior during milling and deposition, (2) verification of IC functional modifications without removal from the FIB system, and (3) ultraprecision control for cross sectioning of deep submicron structures, such as programmed amorphous silicon antifuses. We have also developed FIB system voltage contrast imaging that can be used for a variety of failure analysis applications. The use of passive voltage contrast imaging for defect localization and for navigation on planarized devices will be illustrated. In addition, we describe new, biased voltage contrast ...

1995-09-01

191

Top of tubesheet cracking in Bruce A NGS steam generator tubing - recent experience  

Energy Technology Data Exchange (ETDEWEB)

During the Bruce A Nuclear Generating Station (BNGS-A) Unit 1 1997 planned outage, a dew point search method identified a leak in one steam generator(SG) tube. Subsequently, the tube was inspected with all available eddy current probes and removed for examination. The initial inspection results and metallurgical examination of the removed tube confirmed that the leak was due to intergranular attack/stress corrosion cracking (IGA/SCC) emanating from the secondary side of the tube at the top of the tubesheet location. Subsequently, eddy current and ultrasonic indications were found at the top of the tubesheet of other Alloy 600 SG tubes. To investigate the source of the indications and to validate the inspection probes, sections of 40 tubes with various levels of damage were removed. The metallurgical examination of the removed sections showed that both secondary ...

1998-07-01

192

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

Energy Technology Data Exchange (ETDEWEB)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-07-01

193

Re-Analysis of In-Service Inspection of Pressure Tubes and Feeder Pipes in Wolsong Unit 1  

International Nuclear Information System (INIS)

Since the first commercial operation in 1983, Wolsung unit 1 has experienced several aging phenomena, especially in pressure tubes and feeder pipes. In case of pressure tubes, in-service inspections (ISI) revealed that a major portion of inspected tubes was in contact with calandria tubes. The likelihood of blister formation was a safety concern because it is a potential threat to pressure tube integrity. Wolsung unit 1 was, therefore, subjected to the SLAR (Spacer Location And Reposition) work to separate the contacted pressure tubes from calandria tubes. In this paper, experience of in-service inspection to the pressure tubes will be discussed including the irradiation creep elongation and CIGAR (Channel Inspection and Gauging Apparatus for Reactors) examination of pressure tubes. On the other ...

2005-10-27

194

Characteristics of U-tube assembly design for CANDU 6 type steam generators  

Energy Technology Data Exchange (ETDEWEB)

Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator ...

1996-06-01

195

CFD simulation of steam generator tube rupture thermal-hydraulics  

Energy Technology Data Exchange (ETDEWEB)

Several steam generator tube rupture accidents have occurred at plants in the past. In this paper the Computational Multi-Fluid Dynamics (CMFD) investigation of the horizontal steam generator thermal-hydraulics during the tube rupture accident is performed. A guillotine of a steam generator U-tube is assumed with choked flow from the primary to the secondary side of the steam generator. We have computed water and steam velocity fields, steam volume fraction distribution on the steam generator secondary (shell) side, as well as the swell level increase. The simulation results are a support to the safety analyses of the steam generator tube rupture accident. Numerical simulation is performed with the multidimensional multi-fluid modelling approach. The two-phase flow around steam generator tubes in the bundle is modelled by the porous media approach. Interfacial mass, momentum and ...

2004-07-01

196

A Conceptual Design of Light-weighted Mobile Robot for the Integrity of SG Tubes in NPP  

International Nuclear Information System (INIS)

Steam generators (SG) are among the most critical components of pressurized water Nuclear Power Plants (NPP). SG tubes must provide a reliable pressure boundary between the primary and secondary cooling water. It is because that any leakage from tube defects could result in the release of radioactivity to the environment. Thus degradations of steam generators tubes should be monitored and inspected periodically under nuclear regulatory. In-service inspections of SG tubes are carried out using eddy current test (ECT) and the defected tubes are usually plugged. Because the radioactivity in the internal of SG chambers limits free access of human worker, remote manipulators are required. In South Korea, Manipulators such as the Zetec SM series and the Westinghouse ROSA series have been used. Such manipulators are rigidly mounted to manways or tube sheets of SG. ...

2010-10-01

197

Zn/gelled 6M KOH/O{sub 2} zinc-air battery  

Energy Technology Data Exchange (ETDEWEB)

The gel electrolyte for the zinc-air cell was prepared by mixing hydroponics gel with a 6M potassium hydroxide aqueous solution. The self-discharge of cells was characterized by measuring the open-circuit voltage. The effect of a discharge rate of 50mA constant current on cell voltage and plateau hour, as well as the voltage-current and current density-power density were measured and analysed. The electrode degradation after discharge cycling was characterized by structural and surface methods. The oxidation of the electrode surface further blocked the utilization of the Zn anode and was identified as a cause for the failure of the cell. (author)

2006-09-13

198

PD and BD probability distribution and equiprobabilistic V-T characteristic of oil-filled transformer insulation  

Energy Technology Data Exchange (ETDEWEB)

Probability distributions of partial discharge (PD) and dielectric breakdown voltage were investigated for the typical components of oil-filled transformer insulation. The equi-probabilistic PD and BD V-t characteristics were obtained from experimental results in the time range from several ..mu..sec to 10 hours. The authors point out that there is a close relationship between the scattering of PD voltage and the inclination of V-t characteristics in a long term region for ac voltage.

1982-08-01

199

HVDC cable design logic for digital computers  

Energy Technology Data Exchange (ETDEWEB)

The design of High-Voltage, Direct-Current transmission cables insulated with oil-impregnated cellulose paper is constrained by the maximum temperature and the maximum steady-state and transient stresses (voltage gradients) that the cable insulation can reliably withstand over the desired operating lifetime. Because the electrical stresses in the insulation are related in a very complex fashion to temperature, applied voltage and cable geometry, iterative techniques are required to compute the values of these stresses. Digital computers are ideally suited for these iterative techniques. This paper presents the principal equations and logic needed to develop suitable computer programs.

1992-10-01

200

Environmental concerns for high-voltage transmission lines in UNIPEDE countries  

Energy Technology Data Exchange (ETDEWEB)

High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d`Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.

1996-11-01

201

Environmental concerns for high-voltage transmission lines in UNIPEDE countries  

International Nuclear Information System (INIS)

High-voltage transmission lines can pose an environmental problem, especially in countries where the electricity production is at a distance from the demand location. Planning, construction, and operation of high voltage transmission lines should be conducted within a comprehensive environmental policy, which may include assessment of visual impact, landscape and wildlife protection, and reduction of health risks. This paper reviews the environmental policies and action in planning, construction, and operation as developed by the utilities members of the Union Internationale des Producteurs et Distributeurs d'Energie Electrique (UNIPEDE). The paper also presents a brief outline of the health issues associated with the effects of electromagnetic fields to humans.

1996-01-01

202

Effect of discharge voltage on an ion sheath formed at a grid in a multi-dipole discharge plasma  

International Nuclear Information System (INIS)

It is experimentally demonstrated that a relatively strong ion-rich sheath formed at a fixed negative bias of the grid can be changed to a rather weak ion sheath (sheath potential weakly retards electrons) only by increasing the discharge voltage in the system. At sufficiently high negative grid bias, an increase of discharge voltage enhances the ion collection current at the grid. An explanation is put forward in support of this experimental observation. A slight density enhancement with a fall in plasma electron temperature is also observed with the increasing negative grid bias. (authors)

2008-03-01

203

Damping of capacitance voltage substations ferroresonance using a suitable RLC filter  

Energy Technology Data Exchange (ETDEWEB)

The underlying theory and model of capacitive voltage substations and its associated problems are described. This system is intended to supply electricity to rural communities directly from high-voltage transmission lines. This technique leads to important cost reductions when compared with conventional alternatives. However, in several transient cases, some problems such as ferroresonance and overvoltages could occur in these substations. Using a developed capacitive substation model these transient cases are simulated. A suitable filter is designed to damp overvoltages clue to ferroresonance. Analytical aspects of filter design are presented and some computer simulation tests are provided to highlight the usefulness of the proposed filter. (author)

2004-11-01

204

A new reconfiguration scheme for voltage stability enhancement of radial distribution systems  

International Nuclear Information System (INIS)

Network reconfiguration is an operation problem, which entails altering the topological structure of the distribution feeders by rearranging the status of switches in order to obtain an optimal configuration in order to minimise the system losses. This paper presents a new reconfiguration algorithm that enhances voltage stability and improves the voltage profile besides minimising losses without incurring any additional cost for installation of capacitors, tap changing transformers and related switching equipment in the distribution system. Test results on a 69 node distribution system reveal the superiority of this algorithm.

2009-09-01

205

Failure analysis report: Heat exchanger tubes geothermal binary power plant, Magma Electric Company, East Mesa, California  

Energy Technology Data Exchange (ETDEWEB)

Radian received twelve sections of heat exchanger tubing from the Magma Electric Company's 10MW(e) East Mesa binary geothermal power plant. Three tube sections were received from each of four shell and tube heat exchangers (HX1, Hx6, HX8, and Hx10) of the isobutane vaporizer train. All samples were taken from the upper few rows of tubes. Two months later, four more tube sections were received. These four sections were taken from the lower rows of heat exchangers 1, 6 (two sections), and 10. Radian was requested to investigate the cause of severe pitting failure of these heat exchanger tubes. This report is part of a continuing DOE effort to gain insight into the service life of component materials employed in geothermal energy utilization.

1982-05-01

206

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

Energy Technology Data Exchange (ETDEWEB)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7 x 10{sup 2} {<=} Re {<=} 1.31 x 10{sup 3}. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain circular tube showed a good agreement between them but the data of present ...

2011-01-15

207

When loss is more (for transmission towers) | SmartPlanet  

Wastenet

... ice, hurricanes, and trees (less likely on high voltage transmission lines ) can bring down above ground power lines. Flooding, Leeching ground ...

208

Terms Beginning With \\  

Wastenet

... Microwaves, radio waves, and low-frequency electromagnetic fields from high-voltage transmission lines . Non-Methane Hydrocarbon (NMHC): The sum of all hydrocarbon air ...

209

Silicon MOS inductor  

Energy Technology Data Exchange (ETDEWEB)

A device made of amorphous silicon which exhibits inductive properties at certain voltage biases and in certain frequency ranges in described. Devices of the type described can be made in integrated circuit form.

1981-01-01

210

Performance-Aware Power Management in Embedded Controllers with Multiple-Voltage Processors  

CERN Document Server

The goal of this work is to minimize the energy dissipation of embedded controllers without jeopardizing the quality of control (QoC). Taking advantage of the dynamic voltage scaling (DVS) technology, this paper develops a performance-aware power management scheme for embedded controllers with processors that allow multiple voltage levels. The periods of control tasks are adapted online with respect to the current QoC, thus facilitating additional energy reduction over standard DVS. To avoid the waste of CPU resources as a result of the discrete voltage levels, a resource reclaiming mechanism is employed to maximize the CPU utilization and also to improve the QoC. Simulations are conducted to evaluate the performance of the proposed scheme. Compared with the optimal standard DVS scheme, the proposed scheme is shown to be able to save remarkably more energy while maintaining comparable QoC.

2008-01-01

211

NASA - Hurricane Season 2008: Hurricane Ike (Atlantic Ocean)  

Science.gov (United States)

The company reports that with the help of outside companies, they completed all major fixes including high-voltage transmission lines to neighborhood ...

212

NAME=\\  

Wastenet

...Systems, UWA investigating rate uplift effects of shallow foundation systems associated with high voltage transmission line support towers. This work was funded by National Grid, ...

213

Medium voltage analytical electron microscopy microanalysis versus radiation damage  

Energy Technology Data Exchange (ETDEWEB)

The kinetic energy transferred to some elements by an electron of kinetic energy 100 to 400 kV is discussed. The displacement rates are compared to the signal generation. (DCL)

1985-09-01

214

High-Voltage Transmission Lines: The Ongoing Search for Biological Effects.  

Energy Technology Data Exchange (ETDEWEB)

During the early 1970s, controversy developed over the possible biological effects of electric fields from new 500-kilovolt and 765-kilovolt transmission lines. This, along with growing interest in advancing transmission voltage into the ultrahigh-voltage range (1000 kilovolts and above), led to the initiation of numerous research projects. Several reviews of this research by scientists in the US and other countries indicate that transmission lines have not been proven to be a health hazard to people or animals. The issue remains controversial, however, because research has confirmed some subtle effects of electric fields, and because it is an inseparable part of the public opposition that often accompanies the siting of high-voltage transmission lines. In addition, there is renewed interest in magnetic fields, including a possible association between such fields and human cancers. 2 figures, 2 tables.

1984-12-20

215

High Temperature Superconducting Compounds  

Science.gov (United States)

... Voltage noise power spectral density measurements as a function of temperature, frequency, current, and magnetic field on DyBa2Cu3O7.x (DBCO ...

1992-11-30

216

Experimental Investigations into Phosphoric Acid Adsorption on Platinum Catalysts in a High Temperature PEM FuelCell  

British Library Electronic Table of Contents (United Kingdom)

Abstract Dynamic testing of a phosphoric acid-based high temperature PEM fuel cell shows a peculiar phenomenon. A certain current loss is observed after temperature cycling at constant voltage. This loss is incidentally recovered by applying a cell voltage spike to open circuit voltage. Experimental investigations into temperature, cell voltage, and ageing effects show that this phenomenon might occur due to the orientation of the adsorbed phosphate species on the platinum catalyst surface. Along with some supporting literature and experimental results, a hypothesis is presented in order to explain this occurrence. Phosphoric acid adsorption hysteresis on platinum catalyst due to temperature cycling could cause the temporary cell current loss. Electrode potential-dependent molecule symmetr...

2011-01-01

217

Evidence from 12 geographically disparate power grids - NASA  

Science.gov (United States)

miles of high-voltage transmission lines with 12 intercon- nections to electricity systems in New York and Canada. As of 1 March 2003, ISO New England has ...

218

Dynamic voltage control by remote voltage regulation for pumped storage plants  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a new application in dynamic voltage control based on an older method of voltage regulation. The resulting method is suitable for adoption inn multi-unit pumped storage plants. Inherent operation characteristics of pumped storage plants in the pumping mode can created visible load rejection overvoltages on the transmission and the nearby distribution networks and cause customer complaints. This paper proposes a method in which the on-line units' excitation system impedance compensators are utilized to reduce the magnitude of these overvoltages. This paper presents the theoretical background, computer simulation results, and the field test results at the Pacific Gas and Electric Company's Helms Pumped Storage Plant. This paper should be of interest in the areas of power system planning as well as power system operation.

1988-08-01

219

Division of Solar Energy - NASA Technical Reports Server  

Science.gov (United States)

Metal-semiconductor solar cells reported to date exhibit inherently low output voltages. This effect isa consequence of high diode "saturation" ...

220

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface.

1998-01-01

221

Dielectric-wall linear accelerator with a high voltage fast rise time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators  

Energy Technology Data Exchange (ETDEWEB)

A dielectric-wall linear accelerator is improved by a high-voltage, fast rise-time switch that includes a pair of electrodes between which are laminated alternating layers of isolated conductors and insulators. A high voltage is placed between the electrodes sufficient to stress the voltage breakdown of the insulator on command. A light trigger, such as a laser, is focused along at least one line along the edge surface of the laminated alternating layers of isolated conductors and insulators extending between the electrodes. The laser is energized to initiate a surface breakdown by a fluence of photons, thus causing the electrical switch to close very promptly. Such insulators and lasers are incorporated in a dielectric wall linear accelerator with Blumlein modules, and phasing is controlled by adjusting the length of fiber optic cables that carry the laser light to the insulator surface. 12 figs.

1998-10-13

222

Design concept for radiation hardening of low power and low voltage dynamic memories  

International Nuclear Information System (INIS)

A radiation hard low power, low voltage dynamic memory is obtained by the use of a dummy cell concept. Compared to conventional dummy cell concepts, this concept applies a fully sized dummy cell. By optimizing the dummy cell precharge voltage for 5 V and 3 V operation and the timing of the dummy word-line, the overall soft error rate (SER) of the chip is improved by 2 orders of magnitude. An additional improvement of 1 order of magnitude is possible for 3 V operation by adjusting substrate bias and cell plate voltage. The results are verified by an accelerated SER measurement with a radium 226 source and an additional field soft error study.

223

Computer Controlled MHD Power Consolidation and Pulse ...  

Science.gov (United States)

... is a standard in the utility industry which is used to study switching transients on power distribution networks and high-voltage transmission lines. ...

1990-08-01

224

Compacting high voltage transmission lines in view of dielectric and corona noise constraints. Riduzione di ingombro delle linee di trasmissione nei confronti dei vincoli dielettrici e dei disturbi per effetto corona  

Energy Technology Data Exchange (ETDEWEB)

The paper reports the results of the studies performed at the Electric Research Center of ENEL (Italian National Electricity Board) in the field of compacting high voltage transmission lines, from the point of view of dielectric and corona noise constraints. The results of switching impulse withstand voltage tests, performed on typical compact line insulation configurations, are given and optimization criteria of such insulation configurations in relation to switching impulse are outlined. The constraints regarding surface withstand voltage in polluted conditions of the above insulations are analyzed and the possibility of reducing their dimensions by using unconventional insulation materials is considered. Finally, evaluations of corona noise in the case of optimization of the line encumbrance from the point of view of dielectric constraints are given.

1993-05-01

225

Capturing energy in the air to power electronics | SmartPlanet  

Wastenet

...smart grid applications where you could place them very close to the high-voltage transmission lines , very close to transformers and so on. Photo:...

227

A Multichannel Personal Telemetry System Using Pulse ...  

Science.gov (United States)

... Multivibrators were used in the first model, which is called the "MV Model." Mwe second model, "1ST Model," has a saw-toothed voltage. ...

1961-07-01

228

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

Energy Technology Data Exchange (ETDEWEB)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

1987-07-01

229

Production of intergranular attack of alloy 600, alloy 690, and alloy 800 tubing in tubesheet crevices: Topical report  

International Nuclear Information System (INIS)

Three model boilers, manufactured to simulate full-size tube sheet crevices, were tested with various secondary side environments. The first was faulted with organics representative of the decomposition of humic acid. The second was faulted with sodium carbonate and sodium hydroxide, while the third was faulted with sodium sulfate and sodium hydroxide. Each model contained seven tubes, which included Alloy 600 in the mill-annealed (MA) and thermally-treated (TT) conditions and Alloy 690 in the thermally-treated condition. Two models contained Alloy 800 tubes in the mill-annealed condition and one had Alloy 800 in the mill-annealed/cold-worked/glass-bead-peened condition. Two different sizes of tubesheet crevices were used in all model boilers. In the organics-faulted boiler, tubes of Alloy 600MA, Alloy 690TT and Alloy 800MA experienced no significant intergranular attack (IGA); however, the Alloy 600TT ...

230

The dependence of photovoltage of the system APhV-films photoresistor on the capacity of X-ray radiation dose  

International Nuclear Information System (INIS)

Full text: As you know, thin films which generate anomalous big photovoltage (APhV) , as film photo resistive structures made of the combinations of A_2B_6 respond to X-ray and #gamma#- radiations. In this work the influence of X-ray and #gamma#-radiations on the quantity of APhV in the system APhV-film-photoresistor was investigated. Earlier polycrystal films with anomalous photo voltage properties were received only on the clean and flat surface with high isolation property (R>10"1"4 #OMEGA#). We worked out the technology of receiving APhV films CdTe on the surface of the photosensitive film CdS. The main condition under which this effect may be observed is that the lining must be slant concerning to the direction of the motion of evaporated substance's molecular bunch during the growing of the film, i.e. received film must have a dendritic structure. That is why photosensitive film CdS was received with thermo vacuum slanting pulverization (#alpha#=30-60 ...

2004-08-23

231

White oils for high voltage cables  

Energy Technology Data Exchange (ETDEWEB)

S-120 white oils are used to impregnate insulation and fill high voltage wires. Cooling oil flows of specified viscosities can increase the load capacity of wires. White oils are studied for viscosities and dielectric properties. To meet requirements, S-220 type oils of different medium or low viscosities are tested. Capacity can be increased by viscosity adjustment. Tests were also made to select optimum stabilizing additives to keep low-viscosity.

1983-05-01

232

Underground cables as an alternative to overhead lines. A comparison of economic and technical aspects of voltages over 22 kV  

Energy Technology Data Exchange (ETDEWEB)

The report presents technical and economical aspects of underground cables compared to overhead lines in Norway in high voltage transmission systems above 22 kV. The economical comparison between the two options includes capital costs of installation (investment costs), maintenance costs and costs of electrical losses. The main technical issues discussed are reliability and flexibility. 35 refs., 23 figs., 29 tabs.

1994-07-11

233

Transient sheath overvoltages in armored power cables  

Energy Technology Data Exchange (ETDEWEB)

This paper is concerned with methods of limiting the build-up of transient voltages between sheath and armor in long armored power cables. Calculations by a frequency dependent cable model demonstrate that this voltage can be efficiently limited to an acceptable level by introducing sheath-armor bondings at regular intervals, or by using a semiconductive sheath-armor interlayer. The paper investigates the required minimum length between bondings, as well as the required conductivity of the sheath-armor interlayer if the use of bondings is to be avoided.

1996-07-01

234

Numerical calculation of the transient response of transmission systems using the natural spline functions, with applications on high-voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

To determine the transient response of linear and time-invariant transmission systems which are only described for discret frequencies, it is possible to find a good functional approximation by means of the generalized impulse method, combined with the most important natural spline-interpolation functions of the first and the third degree. This procedure has been applied to calculate the step response of the transient behaviour of the zero-sequence impedance system of the high voltage transmission line.

1981-10-01

235

New type of high voltage sea cable for floating installations; Ny type hoeyspent sjoekabel for flytende installasjoner  

Energy Technology Data Exchange (ETDEWEB)

Nexans has developed a new type of high voltage sea cable with metal barrier for dynamic application, suited for floating installations such as vessels, floating wind turbines or floating platforms. A brief presentation of the cable's design (ml)

2007-07-01

236

Industrial experience with an intelligent AC/DC standard  

Energy Technology Data Exchange (ETDEWEB)

AC/DC voltage standards based entirely on solid-state references used as secondary, working, or transfer standards is widespread, although metrological performance is typically defined only via comparison with a higher level standard. The present report shows the improvements of the output metrological characteristics of an ac/dc calibrator by establishing three internal hierarchical levels of dc voltage references and by constant calibration of ac measuring circuits.

1989-04-01

237

Induction effects of a 765 kV transmission line on a center pivot irrigator  

Energy Technology Data Exchange (ETDEWEB)

The use of irrigation systems in the proximity of high voltage transmission lines is increasing. This study examines the induced voltages and currents on a pivotal irrigation system operating under a 765 kV line. With a few simple precautions such as a system can be operated in complete safety. 1 ref.

1981-01-01

238

Identification and characterization of populations living near high-voltage transmission lines: a pilot study.  

UK PubMed Central (United Kingdom)

Populations living close to high-voltage transmission lines often have residential magnetic field exposures in excess of 1 microT, and sometimes over 2 microT. Yet, populations studied in most epidemiologic...Full Text Available

1993-12-01

239

Fault prediction on high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The prediction of faults on high voltage transmission lines requires the detection of incipient faults, which is implemented by detection of the radio noise due to contaminated insulators, insulation deterioration, and improver connections. It is shown that the radio noise due to incipient faults is separable and identifiable from normal transmission line radio noise, hence faults can be predicted.

1982-12-01

240

Evolution of longitudinal modes in low voltage FEL  

Energy Technology Data Exchange (ETDEWEB)

A low voltage FEL operating at 130 kV which can be run cw with a continuous electron beam current level up to 12 mA has been constructed for the X-Band microwave range (8-12 GHz). In this poster, we will report on the dependence on time, after the electron beam is switched on, of the growth and competition of those longitudinal modes in the cavity having nett gain.

1995-12-31

241

Electrical Circuit Tester  

Energy Technology Data Exchange (ETDEWEB)

An electrical circuit testing device is provided, comprising a case, a digital voltage level testing circuit with a display means, a switch to initiate measurement using the device, a non-shorting switching means for selecting pre-determined electrical wiring configurations to be tested in an outlet, a terminal block, a five-pole electrical plug mounted on the case surface and a set of adapters that can be used for various multiple-pronged electrical outlet configurations for voltages from 100 600 VAC from 50 100 Hz.

2006-04-18

242

Conductance quantization in ferromagnetic Ni nano-constriction  

Energy Technology Data Exchange (ETDEWEB)

The conductance in ferromagnetic Ni nano-wire is quantized in units of 2e{sup 2}/h in the absence of magnetic field, while the units switch to e{sup 2}/h in the magnetic field. The fractional units of 0.7e{sup 2}/h and 1.4e{sup 2}/h with and without magnetic field appear under the application of high bias-voltage. The spin polarization and bias-voltage play an important role in the electric conduction.

2002-02-01

243

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-12-31

244

Calculation of 3-D electrical field distribution around technical devices in the vicinity of high voltage transmission lines  

International Nuclear Information System (INIS)

The influence that electromagnetic fields have on mechanical and electronic equipment was discussed. A three dimensional numerical simulation model of electric fields around high voltage power transmission lines was described. 4 refs., 1 tab., 5 figs.

1997-08-24

245

Calculating ac/dc resistance ratios for high-pressure oil-filled cable designs. Volume 2. Details of mathematical derivations. Final report  

Energy Technology Data Exchange (ETDEWEB)

Conventional methods for calculating electricity losses in pipe-type cable systems rely heavily on data measured in lower-voltage systems in the 1950s. With the new technique developed in this study, engineers can compute power losses more precisely for cables of various configurations and voltage ratings.

1985-04-01

246

An Explanation for Positive Differential dc Voltage-Current Characteristics in Weakly Ionized, Low-Pressure Positive Column Gas Discharge Plasmas  

Energy Technology Data Exchange (ETDEWEB)

A physical explanation is given for the positive differential voltage-current characteristic seen at low current in weakly ionized, low-pressure positive column discharges in argon/mercury gas mixtures. {copyright} {ital 1996 The American Physical Society.}

1996-07-01

247

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

248

A comparison of methods for calculating audible noise of high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

During the last several years, audible noise produced by high voltage transmission lines in corona has emerged as an important design consideration. In this same time frame a number of different methods for calculating audible noise levels have been proposed. The methods currently available, for both ac and dc lines, are described in this paper and are compared through application to practical line geometries for which data from long-term measurements are available.

1982-10-01

249

X-ray phase imaging using a X-ray tube with a small focal spot. Improvement of image quality in mammography  

International Nuclear Information System (INIS)

Phase contrast X-ray imaging has been studied intensively using X-rays from synchrotron radiation and micro-focus X-ray tubes. However, these studies have revealed the difficulty of this technique's application to practical medical imaging. We have created a phase contrast imaging technique using a molybdenum X-ray tube with a small focal spot size for mammography. We identified the radiographic conditions in phase contrast magnification mammography with a screen-film system, where edge effect due to phase contrast overcomes geometrical unsharpness caused by the 0.1 mm-focal spot of a molybdenum X-ray tube. The edge enhancement due to phase imaging was observed in an image of a plastic tube, and then geometrical configuration of the X-ray tube, the object and the screen-film system was determined for phase imaging of mammography. In order to investigate a potential for medical ...

2002-03-01

250

Validating eddy current array probes for inspecting steam generator tubes  

International Nuclear Information System (INIS)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-11-16

251

Validating eddy current array probes for inspecting steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. ...

1997-07-01

252

Studies on improvement of heat transfer characteristics in high temperature heat exchangers, (1)  

International Nuclear Information System (INIS)

Reported in this paper are the theoretical and experimental studies, with regard to the effects of radiation between walls, conducted for the improvement of heat transfer characteristics of the circular duct in high temperature heat exchangers that operate through the medium of non-radiating gases at around 1,000"0C. To study the fundamental performance of the heat transfer augmentation, the experiment was carried out using a double tube at temperatures up to 900"0C. The outer tube in a double tube was selectively heated so as to give a uniform heat flux selected of 6.5 x 10"3 and 4.6 x 10"4 kcal/m"2.h, while the inner tube was used as a radiating surface to impart the radiation heat transmitted from the outer tube. Selectively preheated air was caused to flow in an annular passage at an inlet temperature selected within 100"0C to 400"0C and with the Reynolds number of 2.9 x 10"3 to ...

1978-01-01

253

NPP steam generator: materials and water-chemical regime  

International Nuclear Information System (INIS)

The main reasons of tube failures in steam generators (SG) are considered. 1.Stress corrosion craining which has 28% of SG (most of them have stainless steel tubes). 2. Corrosion loss of metal, which accounts for 24% of tubes (phosphate corrosion due to addition of PO into water). 3.Denting-peripheral pressing of tubes in the openings of the foundation plates by the corrosive products, which are formed on internal surface of drillings in the foundation plates made of carbon steel. 4.Separation of a plating layer on tube panels. 5.Dratting-corrosion. 6.Metal fatigue. A series of experiments were conducted to study the influence of material selection on tube reliability (stainless steel 304, inconel-600, mone-400, incalloy-800). The problem of increase of SG elements reliability is a complex one and can be solved by direct selection of material, proper control of ...

254

FRAMATOME's continuous efforts to improve steam generator corrosion resistance  

International Nuclear Information System (INIS)

Construction of the French PWR nuclear program started in the early 70s, at the time a number of operating plants in the US were being affected by the first corrosion problems. Since, at that time, its construction program was in an early stage, FRAMATOME was able to make modifications on the first units to improve steam generator resistance to corrosion. For instance, full depth expansion of the tubes in the tube-sheet using an explosive process (Westex) was performed on Fessenheim 1 steam generators already installed on site. Later on, continuous operating experience was being obtained in the US, before startup of the French units. This allowed FRAMATOME to react rapidly and take immediate corrective actions at the design stage, during fabrication and sometimes even on site in order to mitigate the risk of corrosion in the steam generators. FRAMATOME is confident that the present design of its steam generator models, including a large number ...

255

Experimental verification of the horizontal steam generator boil-off transfer degradation at natural circulation  

Energy Technology Data Exchange (ETDEWEB)

The presentation summarises the highlights of experimental results obtained for VVER type horizontal steam generator heat transfer, primary side flow pattern, and mixing in the hot collector during secondary side boil-off with primary at single-phase natural circulation. The experiments were performed using the PACTEL facility with Large Diameter (LD) steam generator models, with collector instrumentation designed specifically for these tests. The key findings are as follows: (1) the primary to secondary heat transfer degrades as the secondary water inventory is depleted, following closely the wetted tube area; (2) a circulatory flow pattern exists in the tube bundle, resulting in reversed flow (from cold to the hot collector) in the lower part of the tube bundle, and continuous flow through the upper part, including the tubes that have already dried out; and (3) mixing of the hot leg flow entering the ...

1997-12-31

256

Experimental Evaluation of Tude Support Plate Crevice Chemistry  

Energy Technology Data Exchange (ETDEWEB)

A test methodology for measuring temperature, impedance, pH, and electrochemical potential distributions within a sludge-packed tube support plate crevice in a laboratory test is described. The method successfully showed that there were large concentration gradients between the tube and tube support plate sides of the crevice. The testing also showed that strong bases concentrated more effectively than strong acids, and that the crevice pH, when exposed to seawater-based solutions, increased with increasing superheat and decreasing bulk concentration. The large variations in the crevice chemistry observed under heat transfer were eliminated upon shutdown. These new test data suggest that it might be beneficial to evaluate the variation in the extent of stress corrosion cracking with tube support plate elevation found in some steam generators in light of local chemistry changes, as well as the variation ...

2001-05-08

257

Development of a high performance air heater through use of an evacuated tube cover design  

Science.gov (United States)

Development of a high performance air heater through use of an evacuated tube cover design is described. The cover design utilizes evacuated fluorescent light tubes laid parallel in a close packed array to form an inner transparent glazing over a conventional metal absorber plate with flow behind the plate. A tempered flat glass plate was used as an outer glazing. Both clear and infrared reflective (IR) tubes were investigated. Solar transmittance tests indicate that the clear tube array has a higher transmittance than two flat sheets of low-iron glass. The IR coating produced substantial transmittance loss. Thermal conductance tests indicate that the tubes behave similar to two flat glass sheets with a vacuum in between. The IR reflective coating was only marginally effective at reducing heat conductance. Final prototype designs are presented along with collector performance ...

1980-01-01

258

Constant extension rate (CERT) testing of alloy 690 and 800 nuclear steam generator tubing  

Energy Technology Data Exchange (ETDEWEB)

Constant extension rate (CERT) tests were performed on Alloy 690 and Alloy 800 nuclear steam generator tubing specimens. For the Alloy 690 specimens, tests were performed in deaerated 10% sodium hydroxide solutions at 315 deg C with a +100 mV applied potential. For the Alloy 800 specimens, tests were performed in deaerated 5% sodium hydroxide solutions at 343 deg C with no applied potential. The test specimens were machined from tubing which was produced by different manufacturing processes and in different heat treated conditions. The Alloy 690 tubing was tested in six different thermomechanical conditions, while the Alloy 800 tubing was tested in four different thermomechanical conditions. The results from the test program include a complete microstructural examination using light-optical and scanning electron microscopy. The CERT test results (such as maximum stress achieved and crack morphology) are ...

1994-12-31

259

Comparison of two dose-area-product ionization chambers with different conductive surface coating for over-table and under-table tube configurations  

Energy Technology Data Exchange (ETDEWEB)

A custom-built graphite-coated transmission ionization chamber is compared to the VacuDAP 2001 (VacuTec, Dresden, Germany), which has transparent conductive electrodes. A study was made of the dependence of response on x-ray tube potential for both types of chamber under identical conditions of exposure using over-table and under-table x-ray tubes. Since the calibration factor is the dose-area product of the radiation incident on the patient per chamber reading, it depends on the intrinsic response of the chamber as well as the effect of material in the beam between the x-ray tube and patient. Differences of about 20% were measured between the intrinsic and the over-table calibration factors and between the over-table and the under-table calibration factors for both chambers. The VacuDAP display is specifically calibrated for the over-table condition and would overstate the actual DAP in the under-table case. The intrinsic ...

2000-03-01

260

Semiempirical model based on thermodynamic principles for determining 6 kW proton exchange membrane electrolyzer stack characteristics  

Energy Technology Data Exchange (ETDEWEB)

The performance of a 6 kW proton exchange membrane (PEM) electrolyzer was modeled using a semiempirical equation. Total cell voltage was represented as a sum of the Nernst voltage, activation overpotential and ohmic overpotential. A temperature and pressure dependent Nernst potential, derived from thermodynamic principles, was used to model the 20 cell PEM electrolyzer stack. The importance of including the temperature dependence of various model components is clearly demonstrated. The reversible potential without the pressure effect decreases with increasing temperature in a linear fashion. The exchange current densities at both the electrodes and the membrane conductivity were the coefficients of the semiempirical equation. An experimental system designed around a 6 kW PEM electrolyzer was used to obtain the current-voltage characteristics at different stack temperatures. A nonlinear curve fitting method was employed to ...

2008-12-01

261

High/medium voltage circuit breaker. Disjoncteur a haute ou moyenne tension  

Energy Technology Data Exchange (ETDEWEB)

Conventional gas-filled high voltage circuit breakers have the disadvantages of needing means to compress the arc-extinguishing gas and means for storing a significant amount of energy for operating the breaker. This invention has the object of providing a circuit breaker which does not need a gas compression means and whose energy of operation is very low. The principle of operation used in this circuit breaker consists of creating an arc voltage higher than that of the network. The difficulty of creating a high enough arc voltage in the SF{sub 6} gas normally used in a circuit breaker is resolved according to the invention by dividing the initial arc into a large number of elementary arcs by means of metal plates. The arc voltage of each elementary arc is from 20 to 40 volts, depending on the type of metal used. In a particular embodiment, the circuit breaker contains means for displacing the arc and ...

1990-08-21

262

Electrolyte for high voltage Li/LiMn{sub 1.9}Co{sub 0.1}O{sub 4} cells  

Energy Technology Data Exchange (ETDEWEB)

An electrolyte for high voltage lithium metal anode cells must simultaneously satisfy at least the following requirements; (i) high cycling efficiency on the lithium metal anode; (ii) higher oxidation potential than the charging voltage, and (iii) high specific conductivity. We have examined various electrolytes for lithium metal anode cells using a high voltage cathode, LiMn{sub 1.9}Co{sub 0.1}O{sub 4}. Of the electrolytes resistant to high voltage that we used, a system containing 60 to 90 vol.% of dimethyl carbonate (DMC) mixed with ethylene carbonate (EC) and 1.0 M lithium hexafluorophosphate (LiPF{sub 6}) provided the best cycling efficiency on a lithium metal anode, as well as a high specific conductivity around 10 mS cm{sup -1} at 20 C. (orig.)

1997-10-01

263

An improved soft switched PWM interleaved boost AC-DC converter  

International Nuclear Information System (INIS)

In this paper, an improved soft switched two cell interleaved boost AC/DC converter with high power factor is proposed and investigated. A new auxiliary circuit is designed and added to two cell interleaved boost converter to reduce the switching losses. The proposed auxiliary circuit is implemented using only one auxiliary switch and a minimum number of passive components without an important increase in the cost and complexity of the converter. The main advantage of this auxiliary circuit is that it not only provides zero-voltage-transition (ZVT) for the main switches but also provides soft switching for the auxiliary switch and diodes. Though all semiconductor devices operate under soft switching, they do not have any additional voltage and current stresses. The proposed converter operates successfully in soft switching operation mode for a wide range of input voltage level and the load. In addition, it has advantages ...

2011-01-01

264

Torsion of moderately thick hollow tubes with polygonal shapes  

British Library Electronic Table of Contents (United Kingdom)

A simple formulation is presented for torsion analysis of hollow tubes with polygonal shapes. Thicknesses of segments of cross section can be different. Governing equations in term of Prandtl's stress function are used to derive the formulas. The derived formulas are so simple that computations can be carried out with a pocket calculator. Several examples are presented to show the accuracy and efficiency of the formulation. The obtained results are verified by accurate finite element solutions. It will be seen that the derived formulas can be useful for analysis of thin-walled and moderately thick-walled hollow tubes.

2007-01-01

265

Thermally isolated pipeline  

Energy Technology Data Exchange (ETDEWEB)

The pipelines is provided for gases, particluarly helium, at temperature of about 1000/sup 0/C (pressure about 40 bar) and is used as the connection be tween a gas cooled high temperature reactor and a heat load. The pipe consists of a temperature-resistant inner tube, which is composed of several pipe sections, which are supported on ball bearings, and a gas tight pressurised outer tube. There are supports and insulation between the two tubes. The sub-claims concern fixing of and bearings for the pipe sections. The description is very detailed and supplemented by drawings.

1980-08-28

266

Testing of 12Kh18N10T tube steel samples tendency to intergranular corrosion  

International Nuclear Information System (INIS)

Tendency of 12Kh18N10T steel tube samples to intergranular corrosion (IGC) is investigated by an express electrochemical method in the 10% solution of H_2SO_4+0.0025 g/l of KCNS. Tendency to IGC is mainly detected on the internal surface of tube samples. It is shown that the tendency to INC under plant conditions is caused by surface carburization under its incomplete purification from the graphite lubrication.

1993-01-01

267

Stress corrosion cracking of Alloy 600 using the constant strain rate test  

International Nuclear Information System (INIS)

Nuclear grade production tubing of Alloy 600 was evaluated for stress corrosion cracking (SCC) susceptibility in high purity water at 365, 345, 325, and 290 C. Reverse tube U-bend specimens provided crack initiation data and constant extension rate tests were employed to determine the crack velocities experienced in th crack propagation stage. Initial results indicate that a linear extrapolation of data received from high temperature tests can be used to predict the service life of steam generator tubing that has been plastically deformed or is continually deforming by ''denting.''.

268

Longitudinal emittance oscillation in a superconducting drift tube linac  

International Nuclear Information System (INIS)

In drift tube linacs a beam energy spread results form the finite beam size. Radial variation of the axial accelerating field induces a beam energy spread, which, in general, will accumulate as the beam passes through successive drift tubes. This paper shows that under some conditions of periodic transverse focusing and longitudinal phase focusing, the correlation between the longitudinal and transverse motion can be used to correct the energy spread. The process of achieving such a correction is first described in a simplified situation, and then demonstrated for a particular tuning using a ray-tracing program which models a low velocity and low charge state linac designed for radioactive ion beams.

1995-05-01

269

Heat transfer characteristics of laminar flow in internally finned tubes under various boundary conditions  

Science.gov (United States)

Numerical solutions for fully developed laminar flow in internally finned tubes with trapezoidal and triangular fin profiles were given with Finite Element Method (FEM): The heat transfer characteristics were obtained and compared under the boundary conditions of uniform heat flux, uniform wall temperature, and the third boundary condition with finite wall thermal conductivity considered. The numerical results show that boundary conditions have pronounced effects on the temperature field. Furthermore, a new mechanism on the heat transfer augmentation of internally finned tubes is proposed.

1994-06-01

270

Feasibility study on scheme of disposing spent guide tubes at Daya Bay nuclear power plant  

International Nuclear Information System (INIS)

The author describes feasibility study on the scheme of disposing spent guide tubes at Daya Bay nuclear power plant, including scheme selection, packing cask design, disposal operation and technological process, budget estimation and safety evaluation. The research results show that the new scheme is feasible on technology, and reasonable on budget. If the scheme is adopted to dispose the spent guide tubes at Daya Bay nuclear power station, it can not only save large funds, but also accumulate experience on disposing non-compressible low and intermediate level solid radioactive wastes produced at nuclear power station for the country

1998-12-01

271

Evaluation of optimum sheath electric field for selective production of metallic carbon nanotubes  

International Nuclear Information System (INIS)

We estimate the optimum electric field at the sheath edge and the minimum interval among the nanotubes to promote the growth of armchair-type nanotubes (metallic character) as a function of the tube length. On the basis of the electric charge distribution in a nanotube and the optimum electric filed E*_1 at the tip of a nanotube evaluated using the Hueckel-Poisson method, we calculate the structure of the electric field lines outside a nanotube in the sheath region. As the tube length increases, the E*_1 decreases. To maintain the chemical activity at the tip, the sheath electric field must be decreased. We show the decreasing rate of the sheath field to the tube length.

2006-03-21

272

Design parameters for tube cavity receivers in solar power plants  

Energy Technology Data Exchange (ETDEWEB)

The design of a solar heated cavity receiver transferring 60 MW of thermal energy to the working medium (air) for a closed-cycle gas turbine is described. The gas turbine plant with its cycle layout is presented. Then the tubes for the receiver are designed taking into account thermal and mechanical loads. It is shown how the occurring stresses are influenced by the destribution of the locally absorbed hat flux. Calculations for an existing coal fired air heater of a closed-cycle gas turbine give a first impression of the long-term behaviour to be expected of the receiver tubes.

1981-01-01

273

Application of neutron radiography to visualization of multiphase flows  

Energy Technology Data Exchange (ETDEWEB)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-04-01

274

Application of neutron radiography to visualization of multiphase flows  

International Nuclear Information System (INIS)

Visualizations by real-time neutron radiography are demonstrated of various flow patterns of nitrogen gas-water two-phase flow in a stainless-steel tube, water inverted annular flow in a stainless-steel tube, flashing flow in an aluminium nozzle and fluidized bed in aluminium tube and vessels. Photographs every 1/60 s are presented by an image processing method to show the dynamic behaviours of the various flow patterns. It is shown that this visualization method can be applied efficiently to multiphase flow researches and will be applicable to multiphase flows in industrial machines. (author).

1990-01-01

275

Analysis of laminar flow heat transfer in uniform temperature circular tubes with tape inserts  

Science.gov (United States)

Constant property, laminar flow heat transfer in a semicircular tube with uniform wall temperature has been analyzed to define the lower bound of heat transfer augmentation in circular tubes with twisted-tape inserts. Two thermal boundary conditions, which correspond to the two extremes of the fin effect of twisted tapes encountered in practical applications, are considered. Numerical solutions, employing finite-difference formulations for the governing momentum and energy equations were carried out for the thermal entrance region and for fully developed flow.

1986-05-01

276

An investigation of turbulent convection heat transfer performance in spiral spring coil inserted tubes  

International Nuclear Information System (INIS)

This paper presents the results of the experimental investigation on heat transfer and fluid friction characteristics of a class of spiral spring coil used as a tube side forced convection heat transfer augmentation devices. Based on a lot of experimental data, the heat transfer correlation and fluid friction correlation revised by temperature were reached in terms of linear regression. At the same time, proper criteria were used to evaluate the economic performance of the spiral spring inserted tube according to the demand of practical application and some probing analysis were made.

1996-01-01

277

A new procedure for cutting out the broken thermocouple tubes inside the deep holes in the tube plate of moisture re-heater at Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

The scenario of the development of a new procedure for cutting out the broken protective wells for thermocouples inside the deep holes in the tube plate in the moisture re-heater (MSR) at Daya Bay nuclear power station is presented. Focused in the innovation and improvement of the self-made tools, the new procedure produced an effective method to cut out swing long inserts stuck inside the deep holes. (authors)

2005-09-01

278

X-Ray Fluorescence Analysis of Composite Propellants for ...  

Science.gov (United States)

... The constancy of the X-ray intensity ratio for each element in Table 8 as the X-ray tube settings were changed shows the excellent compensating ...

1977-06-03

279

Visualization and measurement of refrigerant flow in compression-type refrigerator by neutron radiography  

International Nuclear Information System (INIS)

The refrigerant two-phase flows in a capillary tube and a distributor used in a compression-type refrigerator were visualized by real-time neutron radiography. The thermal neutron radiography system of JRR-3M at the Japan Atomic Energy Research Institute was used. In the visualization experiments of the two-phase flow in the capillary tube of 2 mm I.D., a cooled CCD camera was used, and the axial one-dimensional distributions of void fraction were measured. For the distributor, a high sensitivity video camera with a silicone intensified target tube was used. From the visualized images, the refrigerant behaviors in the distributor were clearly shown, and the liquid fraction in each tube was measured. As a result, it was shown that the refrigerant behaviors in the distributor effected the distributing performance of the refrigerant flow.

1999-11-03

280

The interventional treatment for biliary recurrent obstruction after palliative T tube drainage in patients with obstruction due to cholangiocarcinoma  

International Nuclear Information System (INIS)

Objective: To explore the interventional method to treat biliary recurrent jaundice after T tube drainage in patients with malignant obstructive jaundice due to cholangiocarcinoma. Methods: 7 biliary metallic stents were placed in 7 patients with recurrent jaundice after T-tube drainage in cholangiocarcinoma cases. Results: Stent placement was once successful in all 7 cases with successful rate of 100%. For all cases, TBIL, ALT, GTP and AKP values 7 days postoperatively were significantly lower than that of preoperation together with subsidence of jaundice satisfactorily for 100% after the treatment. Conclusions: Percutaneous placement of biliary metallic stents was effective economic, minimal invasive and safe for palliation of biliary recurrent jaundice after T tube drainage in cholangiocarcinoma-induced obstructive jaundice

2002-10-01

281

Strain Rate Effects on Ultimate Strain of Copper  

Science.gov (United States)

... Figure 3a. PETN Filled Tube Specimen Detonated by Exploding Bridgewire Specimen POLYETIILLENE END-CAP "1- 901am WALL IHICKNESS ...

1979-05-01

282

Steam Generator Group Project: Annual report, 1985  

Energy Technology Data Exchange (ETDEWEB)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

1987-04-01

283

Steam Generator Group Project: Annual report, 1985  

International Nuclear Information System (INIS)

This report is a summary of the Steam Generator Group Project progress for 1985. Statistical analyses are presented of data from nondestructive examination (NDE) round robin tests that were performed on the Surry generator in 1984. In the first round robin, teams acquired and analyzed their own data on a selected 10% subset of tubes. In the second round robin, analysts from each participating team analyzed identical sets of data which were provided to them by the Project. Results from several examinations utilizing advanced/alternate NDE technologies including alternate eddy current probes and techniques, ultrasonics, and profilometry are also reported. Criteria are listed for selecting tube specimens that will be removed from the generator. A sampling plan based on these criteria is detailed graphically in the report. The initial steps that have been taken to carry out the plan are described; tooling fabricated for the sample removals is ...

284

Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions  

Energy Technology Data Exchange (ETDEWEB)

Since the fluoroscopic image during nasoenteral tube placements is used for guidance and not for diagnosis, a lower contrast image with increased quantum mottle can be easily tolerated. The three methods to reduce the radiation dose rate investigated consisted of removing camera from the image intensifier output phosphor, and setting the fluoroscopic mA to the minimum value so that the kVp could be maximized. Fluoroscopic frozen video frames of a clinical tube insertion comparing the images with and without the dose-saving techniques are presented. Measurements of the radiation dose rates using a Plexiglas phantom show that the dose for patient and staff during fluoroscopic-guided nasoenteral tube placements can be reduced by over a factor of 10 without significantly adversely affecting the actual placement procedure. (author).

1992-02-01

286

Initiation process of type 1 pitting corrosion on copper water-tubes; Reisui yo dokan ni okeru 1 gata koshoku no hassei  

Energy Technology Data Exchange (ETDEWEB)

Copper tubes have been widely used for water supply and heat exchangers. In such systems copper tubes often suffer from type 1 pitting-corrosion. A mechanism, of the type I pitting-corrosion on copper tubing has been presented, but a initiation mechanism of the pitting corrosion is still unknown. In this paper we aimed to clarify the initiation mechanism of the pitting corrosion. Copper-tube specimens were immersed in a circulating solution. The solution had been used for heat exchangers at a Japanese factory where the water leakage occurred by the pitting corrosion on copper tubes. The solution contained tiny precipitates resulted from corrosion of galvanized steel pipe. During the immersion test changes in the surface state of a copper tube was analyzed by in situ RAMAN (in situ Raman Spectroscopy), SEM (Scanning Electron Microscope), EPMA (Electron Probe ...

1999-07-15

287

Indium(III) Compounds Containing the Neopentyl Substituent ...  

Science.gov (United States)

... learn more about the thermal stability of InNP2 Me, a sample contained in a previously evacuated tube was heated at 100°C for 13 days. Neither ...

1989-02-24

288

History of Bioterrorism: Botulism  

Medline Plus

... Pan Flu Preparedness YouTube is Your Friend Additional Resources ... Response Hurricane Readiness in High-Risk Areas: Survey Results Elements of ...

289

Far-out Pathways to Space: Great Guns? - ISTP  

Science.gov (United States)

The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he ...

290

Far-out Pathways to Space: Great Guns?  

Science.gov (United States)

Turbine Afterword The SHARP cannon. Hydrogen is compressed in the tube on top, the gun barrel is on bottom. When Jules Verne wrote in 1865 "From Earth to the Moon" he envisioned...

2011-09-03

291

Development of the SSC (Superconducting Super Collider) trim coil beam tube assembly  

Energy Technology Data Exchange (ETDEWEB)

The Superconducting Super Collider uses approx. =9600 dipole magnets. The magnets have been carefully designed to exhibit minimal magnetic field harmonics. However, because of superconductor magnetization effects, iron saturation and conductor/coil positioning errors, certain harmonic errors are possible and must be corrected by use of multipole correctors called trim coils. For the most efficient use of axial space in the magnet, and lowest possible current, a distributed internal correction coil design is planned. The trim coil assembly is secured to the beam tube, a uhv tube with special strength, size, conductivity and vacuum. The report details the SSC trim coil/beam tube assembly specifications, history, and ongoing development.

1987-01-01

292

Development of a FeCoNb Alloy to be used in Eddy Current ...  

Science.gov (United States)

... Accession Number : ADD336001. Title : Development of a FeCoNb Alloy to be used in Eddy Current Probes for Testing Ferromagnetic Tubes,. ...

293

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

International Nuclear Information System (INIS)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-22

294

Development of In-Service Inspection system for heat transfer tubes in the primary pressurized water cooler in the HTTR  

Energy Technology Data Exchange (ETDEWEB)

The ISI (In-Service Inspection) system has been developed so as to maintain the structural integrity of heat transfer tubes in the primary pressurized water cooler in the HTTR (High Temperature Engineering Test Reactor). This system consists of eddy current probes, ultra-sonic probes, insertion and extraction units, positioning unit and so on. Verification and performance tests of the developed ISI system were carried out using mock-up heat transfer tubes in the primary pressurized water cooler. The constitution of the system, R and D results of the inspection probes, and verification and performance test results of the ISI system for heat transfer tubes are described in this paper. (author)

1999-08-01

295

Central Venous Access Catheters (CVAC) and Gastrostomy (Feeding) Tubes  

Science.gov (United States)

... of CVACs, including tunneled catheters (Hickman or Broviac), peripherally inserted central catheters (also called PICC lines or long lines), ...

296

Burner systems  

Energy Technology Data Exchange (ETDEWEB)

A burner system particularly useful for downhole deployment includes a tubular combustion chamber unit housed within a tubular coolant jacket assembly. The combustion chamber unit includes a monolithic tube of refractory material whose inner surface defines the combustion zone. A metal reinforcing sleeve surrounds and extends the length of the refractory tube. The inner surface of the coolant jacket assembly and outer surface of the combustion chamber unit are dimensioned so that those surfaces are close to one another in standby condition so that the combustion chamber unit has limited freedom to expand with that expansion being stabilized by the coolant jacket assembly so that compression forces in the refractory tube do not exceed about one-half the safe compressive stress of the material; and the materials of the combustion chamber unit are selected to establish thermal gradient parameters across the combustion chamber ...

1984-07-10

297

BAM: Staphylococcal Enterotoxins  

Science.gov (United States)

... Dialysis tubing. Cellulose casing of 1-1/8 inches flat width and an average pore diameter of 48 Angstrom units is used (12,000-14,000 mol wt exclusion). ...

298

Augmentation of laminar flow and heat transfer in flat tubes by means of helical screw-tape inserts  

British Library Electronic Table of Contents (United Kingdom)

The heat transfer a characteristics and friction factor in the horizontal double pipes of flat tubes with full length helical screw element of different twist ratio and helical screw inserts with different spacer length are investigated. Cold and hot water are used as working fluid in tube side and shell side respectively. The experiments covered a range of Reynolds numbers 5.7x102Re1.31x103. The effect of spacer length on the heat transfer augmentation and friction factor and the effect of twist ratio on heat transfer augmentation and friction factor have been presented separately. The study shows that, the Nusslet number (Nu) and friction factor (f) decrease with the increase of S or Y for flat tube. The comparison between the data of present plain circular with that of previous plain ci...

2011-01-01

299

Application of Combined Enhanced Techniques for Design of Highly Efficient Air Heat Transfer Surface  

British Library Electronic Table of Contents (United Kingdom)

In order to reduce the size and cost of heat exchangers, an air-side wavy fin-and-tube heat transfer surface with three-row tubes needs to be replaced by two-row tubes with some appropriate enhancing techniques. The major purpose of the present paper is to search for such new structure by numerical simulation. First, longitudinal vortex generators of Delta-winglet type are tried. The influence of number and of arrangement of the winglets on the performance of the heat transfer surface is studied in detail. The numerical results show that the fin with two winglets aligned spanwise in the front and rear of each tube (Fin W6) has higher heat transfer capability than other enhanced structures with vortex generators, but it still unable to meet the heat transfer requirement. Then a combination ...

2012-01-01

300

A New Tool for Accurately Measuring the Inside Diameter of a ...  

Science.gov (United States)

Page 1. AD-769 272 A NEW TOOL FOR ACCURATELY MEASURING THE INSIDE DIAMETER OF A GUN BARREL, LONG TUBE, OR SIMILAR ...

1973-08-29

301

120-MM Gun Tube Erosion Including Surface Chemistry ...  

Science.gov (United States)

... with dynamic gridding capability to account for material ablation, as well as the addition of energy sources and heat transfer augmentation due to ...

1997-10-01

302

(12) United States Patent  

Science.gov (United States)

Sep 19, 2005 ... within a sealed tube to control the environment to which a sample mounts are better suited to handling the very small crystal is exposed. ...

303

Long pulse production of high current D"- ion beams in the JT-60 negative ion source  

International Nuclear Information System (INIS)

The first long pulse production of high power D"- ion beams has been demonstrated in the JT-60 U negative ion sources, each of which was designed to produce 22 A, 500 keV D"- ion beams. Voltage holding capability and the grid power loading were examined for long pulse production of high power D"- ion beams. From the correlation between voltage holding and the light intensity of cathodoluminescence from the Fiber Reinforced Plastic insulators, the acceleration voltage for stable voltage holding capability was found to be less than 320-340 kV where the light was sufficiently suppressed. By tuning the extraction voltage, the grid power loadings in the ion sources were decreased to the allowable levels for long pulse injection without a significant reduction of the beam power. After tuning the acceleration and extraction voltages, D"- ion beams of 12.5 and 9.8 A ...

2008-02-01

304

High frequency breakdown voltage  

Energy Technology Data Exchange (ETDEWEB)

This report contains information about the effect of frequency on the breakdown voltage of an air gap at standard pressure and temperature, 76 mm Hg and O{degrees}C, respectively. The frequencies of interest are 47 MHz and 60 MHz. Additionally, the breakdown in vacuum is briefly considered. The breakdown mechanism is explained on the basis of collision and ionization. The presence of the positive ions produced by ionization enhances the field in the gap, and thus determines the breakdown. When a low-frequency voltage is applied across the gap, the breakdown mechanism is the same as that caused by the DC or static voltage. However, when the frequency exceeds the first critical value f{sub c}, the positive ions are trapped in the gap, increasing the field considerably. This makes the breakdown occur earlier; in other words, the breakdown voltage is lowered. As the frequency increases two decades or more, ...

1992-03-01

305

50 Hz - electromagnetic fields. Regulations concerning non-ionizing radiation; 50 Hz-Magnetfelder. Gesetzgeberische Moeglichkeiten auf dem Gebiet der nichtionisierenden Strahlung und Handlungsprogramme in Schweden  

Energy Technology Data Exchange (ETDEWEB)

As a central supervision authority the National Electrical Safety Board (Elsaekerhetsverket) has the main responsibility for the safety of high voltage power lines and other power electric equipment. It is therefore also responsible for questions concerning the effects of power frequency magnetic fields on the environment. According to the rules it is not allowed to draw overhead power lines with a voltage exceeding 1000 V above buildings. Their minimum distance to buildings must not be below 5 m. For regions comprised by rural development plans the directions prescribe a minimum distance of 10 m between buildings and high voltage transmission lines with a voltage of 55 kV or more. The publication of two large epidemiological studies about exposure to magnetic fields and cancer in Sweden in autumn 1992 has brought magnetic fields problems to general notice again. A statement on health risks form ...

1993-06-01

306

Working hot  

International Nuclear Information System (INIS)

The author says ''barehand'' methods, where specially trained utility workers are called in conductive suits to equalize voltage over their bodies, to maintain high-voltage transmission lines are on the rise. Utilities are building lines at higher voltages and selling more power to other utilities, making it highly inconvenient to take the lines out of service. However, some unions view the barehand work with less than enthusiasm. Touching lines energized at hundreds of thousands of volts demands flawless equipment and rigid work procedures followed to the letter. Some local unions contend that adequate safety procedures and training, and appropriate penalties for workplace negligence, should be in place before utilities may do barehand work. The author discusses some of the methods of barehand work and the equipment used, i.e. steel-mesh lineman's suit, bucket truck's boom, helicopters, and robots.

1988-01-01

307

Very high voltage cables with synthesis insulation; Les cables tres haute tension a isolation synthetique  

Energy Technology Data Exchange (ETDEWEB)

A historical review on insulated cables for power transmission, is presented, beginning with impregnated paper insulation, oil filled cables and natural rubber cables. High density and chemically reticulated polyethylene were then used for high voltage and very high voltage cables; the advantages of polyethylene compared to impregnated paper cables are discussed, which led to research programs at EDF on various themes concerning the optimization of polyethylene cables: dielectric properties and reliability, thermomechanical behaviour, thermal ageing of materials, testing methods (acceptance dielectric test and long duration temperature test); utilization of low- and high-density and chemically reticulated polyethylene for 225 kV cables is discussed

1997-06-01

308

Production engineering measure for capacitors, electrolytic aluminum high reliability, high voltage  

Science.gov (United States)

Production engineering measures for improving production techniques to increase the reliability of high voltage, high temperature aluminum electrolytic capacitors have been completed. The required number of capacitors for each contract item were life tested at 85C for 10,000 hours. There were 9,400 capacitors on the extended life test. Reliability for CU13 and CU17 capacitors and contract item 2AG rated 1.5 mfd - 400 V are shown. The verification testing, which was performed at 125 C on 40 capacitors for each contract item, met the requirements of MIL-C-39018A. It further demonstrated that in addition to CU13 styles which are designed to operate at 125 C, the CU17 manufactured for this contract are capable of operating at 125C with derated voltage. Process specifications and Quality Control Manual are included.

1975-07-01

309

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

Energy Technology Data Exchange (ETDEWEB)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-12-31

310

Optimum arrangements of the phase conductors of overhead transmission lines for the electric field minimization  

International Nuclear Information System (INIS)

The magnitude of electric and magnetic fields around a high voltage three-phase transmission line was studied. A three-phase transmission circuit with parallel conductors produces rotating elliptic electric and magnetic fields. This study investigated the optimum arrangement of the phase conductors to minimize the maximum value of the magnetic flux density and to minimize the intensity of the resultant electric field. Two different types of high voltage double circuit transmission lines of 400 kV were considered. The optimum arrangement of the phase conductors was determined. It was concluded that the optimum arrangement can be easily applied to already constructed high voltage transmission lines by properly interchanging the phase conductors at the substations. 10 refs., 1 tab., 4 figs.

1997-08-24

311

Influence of mechanical bending and temperature on the threshold voltage instability of a-Si:H thin-film transistors under electrical stress  

British Library Electronic Table of Contents (United Kingdom)

This paper studies the electrical characteristics of hydrogenated amorphous silicon thin-film transistors (a-Si:H TFTs) under flat and bending situations after AC/DC stress at different temperatures. Stress temperature was varied from 77K to 400K, and threshold voltage shifts were extracted to analyze degradation mechanisms. It was found that high temperature and mechanical bending played important roles under AC stress, with an enhanced stress effect resulting in a more serious degradation. This study also discusses the dependence between the accumulated sum of bias rising and falling time and the threshold voltage shifts under AC stress.

2011-01-01

312

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...

1986-04-01

313

Fabrication of shuttle-junctions for nanomechanical transfer of electrons  

International Nuclear Information System (INIS)

We report on the fabrication of nanomechanical devices for shuttling of electrons from one electrode to another. Each device consists of a 20 nm diameter gold nanoparticle embedded within the gap between two gold electrodes. In two different kinds of shuttle-junctions the nanoparticle is attached to the electrodes through either (i) a single layer of 1,8-octanedithiol or (ii) a multilayer of 1-octanethiol molecules. The thiol layers play the role of 'damped springs', such that when a sufficient voltage bias is applied to the junction, the nanoparticle is expected to start oscillating and thereby transferring electrons from one electrode to the other. For both kinds of shuttle-junctions we observed an abrupt increase in the transmitted current above a threshold voltage, which can be attributed to a transition from the stationary to the oscillating regime. The threshold voltage was found to be lower for single-layer ...

2009-12-02

314

Electrotransmission of high traffic capability. Elektroperedachi povyshennoi propusknoi sposobnosti  

Energy Technology Data Exchange (ETDEWEB)

Comparative indices are given for the efficiency of phase control of remote-controlled self-compensating high-voltage transmission lines, including a consideration of the power transfer effect between high-voltage line circuits. A description is given of certain circuit variations for performing the technical means of regulating phase shift, and their characteristics which make it possible to evaluate the effect of the phase regulators on the electrical transmission system are also given. An examination is made of problems concerned with the design of lines, relay protection, computation of transfer processes and dynamic stability as well as the computation of over-voltage when shutting off short circuits during amplified electromagnetic ties between line circuits.

1981-01-01

315

Electron transport through asymmetric DNA molecules  

British Library Electronic Table of Contents (United Kingdom)

We investigate quantum mechanical electron transport along the long axis of the DNA molecule using an effective tight-binding model. The overall contour plot of transmission, the current-voltage characteristics, and the differential conductance are examined for the variation of backbone onsite energy, the energy-dependent hopping strength, and the contact coupling between the leads and the DNA molecule. It is shown that as backbone asymmetry increases, the merging and collapse of the two mini-bands take place and an extra resonance peak in the transmission appears. In addition, we present the modulation of voltage threshold in the current-voltage curves and a double-peak structure in the differential conductance due to the disappearance of the merged mini-band. Finally, in the Coulomb bloc...

2010-01-01

316

Electromagnetic compatibility and power quality: engineering contribution; Compatibilite electromagnetique et qualite de l`onde: contribution de l`ingenieur-conseil  

Energy Technology Data Exchange (ETDEWEB)

Problems relating to electromagnetic compatibility and power quality were discussed, combined with a discussion of the role that consulting engineers can play in resolving them. The need for the consulting engineer to be aware of design specifications of equipment was considered essential. Similarly, the interrelationship between installations using variable speed drives, halogenous lighting systems, capacitor banks, high-voltage power lines, power transformers, etc., and the need for familiarity with the operating characteristics of different types of power systems were stressed as key ingredients to success in ascertaining events and causes of equipment failure or power system problems on the network. The main sources of disturbances, impact of voltage variations, the importance of controlling voltage imbalance, and system protection were summarized. 4 figs.

1996-08-01

317

Electrochemical characterization of MnO2 as the cathode material for a high voltage hybrid capacitor  

British Library Electronic Table of Contents (United Kingdom)

Manganese dioxide (MnO2) was prepared using the ultrasonic method. Its electrochemical performance was evaluated as the cathode material for a high voltage hybrid capacitor. And the specific capacitance of the MnO2 electrode reached 240 F.g-1. The new hybrid capacitor was constructed, combining Al/Al2O3 as the anode and MnO2 as the cathode with electrolyte for the aluminum electrolytic capacitor to solve the problem of low working voltage of a supercapacitor unit. The results showed that the hybrid capacitor had a high energy density and the ability of quick charging and discharging according to the electrochemical performance test. The capacitance was 84.4 mF, and the volume and mass energy densities were greatly improved compared to those of the traditional aluminum electrolytic capacito...

2009-01-01

318

Electrical properties of a calix[4]acid/amine Langmuir-Blodgett thin film  

British Library Electronic Table of Contents (United Kingdom)

In this work the DC and AC characteristics for metal-LB film-metal structures deposited by a standard Langmuir-Blodgett film deposition technique are investigated. The conduction mechanism has been studied for a thin film structure in which a calix[4]arene substituted with carboxylic acid groups has been deposited alternately with a calix[4]arene molecule substituted with amine groups. This LB film structure shows a typical insulating behaviour for low voltage values and the Schottky effect becomes dominant when the voltage increases. The conductivity at low voltage values was found to be 1.34x10^-^1^3Scm^-^1. The height of the potential barrier was determined to be 1.65eV for this alternate layer LB film system.

2011-01-01

319

Design: voice activated door opener.  

Science.gov (United States)

A voice activated garage door opener was designed for a handicapped person to open a garage door without assistance. This design uses speech recognition of one word. The activating word that was chosen is "up". The frequency spectrum of "up" was captured on a soundboard and is the basis of this design. Filters are used to pick out three frequency bands in this spectrum. The output signals from these filters are then compared to three threshold voltages using voltage comparators. If the output signals from the filters are above the threshold voltages, the comparators go high. Monostable multivibrators are used on the output of the comparators to lengthen the high pulses. When all of the pulses from the monostable multivibrators are high at the same time, an AND gate output goes high. This high pulse activates the door opener. PMID:8329601

1993-01-01

320

Design concepts for simulators of EMP-induced surges in the electric power system  

International Nuclear Information System (INIS)

The nation's electric power system would be subject to induced surges in the event of a high altitude nuclear burst. The HEMP would be coupled to overhead power lines and cause severe overvoltage to components connected to the line. This paper discusses the design of pulsed power equipment needed to simulate this induced EMP. A facility is described which is capable of testing the vulnerability of components by applying appropriate voltage and current waveforms. The pulser can provide waveforms under a variety of test conditions to meet the requirements of different types of components. A 3-5 MV Marx pulser is described. It has the capability of generating a fast rising voltage followed by two distinct exponential decays. The testing of components, charged with their normal voltage is also described.

321

Delta connected resonant snubber circuit  

Energy Technology Data Exchange (ETDEWEB)

A delta connected, resonant snubber-based, soft switching, inverter circuit achieves lossless switching during dc-to-ac power conversion and power conditioning with minimum component count and size. Current is supplied to the resonant snubber branches solely by the dc supply voltage through the main inverter switches and the auxiliary switches. Component count and size are reduced by use of a single semiconductor switch in the resonant snubber branches. Component count is also reduced by maximizing the use of stray capacitances of the main switches as parallel resonant capacitors. Resonance charging and discharging of the parallel capacitances allows lossless, zero voltage switching. In one embodiment, circuit component size and count are minimized while achieving lossless, zero voltage switching within a three-phase inverter.

1998-01-01

322

Apparatus for producing controlled positive or negative corona discharge for semiconductor materials processing  

Energy Technology Data Exchange (ETDEWEB)

An apparatus capable of producing current or voltage controlled positive and negative ion beams in 1-atm oxidizing and nonoxidizing ambients between 25/sup 0/ and 950 /sup 0/C is presented. The apparatus utilizes a point-to-plane corona discharge in the gas phase. Room-temperature experiments revealed that the small differences in ion beam shape between the two polarities is primarily due to the difference in applied voltage required to produce the same current for the two polarities. Due to increased ion mobility and decreased threshold voltage at higher temperatures, a slight broadening of the ion beam current-density profiles for both positive and negative ions is predicted.

1984-09-01

323

An PB?-73C vacuum spark gap with a control circuit based on an inductive energy storage  

British Library Electronic Table of Contents (United Kingdom)

The design and operating principle of a small (50 mm in diameter and 100 mm in height) ???-73C vacuum spark gap are described. It is shown that it can be efficiently switched using a control circuit with a low (?900 V) supply voltage, which is based on an inductive energy storage and a diode opening switch that forms a high-voltage igniting pulse with a rise time of nanosecond duration. The ???-73C switching process is investigated at different rise times of igniting voltage pulses and different igniting current amplitudes. The results of tests of the spark gap operating in regimes of switching current pulses with an amplitude of 12 kA and a rise time of 800 ns are presented.

2011-01-01

324

Adaptation of an air-dielectric RF cable for use as an oil-filled high voltage pulse transmission line  

Energy Technology Data Exchange (ETDEWEB)

This paper describes the specifications, conceptual design, prototype testing and operating experience of an oil-filled high voltage pulse transmission cable adapted from commercially available air-dielectric RF components. Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) requires a method of transmitting 250kV, 70 nanosecond pulses from the power conditioning equipment to the accelerator. The oil-filled cable approach was chosen over alternative concepts because of its high voltage holding capacity, long life and flexibility. The criteria for cable and connector design are discussed. The results of prototype testing and performance of the final design are presented.

1984-11-01

325

5 GHz GaAs monolithic astable multivibrator type voltage controlled oscillator  

Science.gov (United States)

A 5 GHz GaAs monolithic astable multivibrator-type voltage-controlled oscillator has been developed. The monolithic oscillator uses 2 micron long self-aligned TiW-silicide gate MESFETs as well as GaAs Schottky diodes for capacitance. Good agreement between the experiment and calculations for oscillation frequency characteristics versus control voltage is obtained by assuming donor density in the FET active layer to be a Gaussian distribution. This oscillator is useful for monolithic front ends and phase-locked oscillators used in microwave signal processing. X-band oscillation frequency can be obtained with 1 micron long gate FET and low loss resonance inductors.

1984-03-01

326

Transient burnout in flow reduction condition  

International Nuclear Information System (INIS)

A transient flow reduction burnout experiment was conducted with water in a uniformly heated, vertically oriented tube. Test pressures ranged from 0.5 to 3.9 MPa. An analytical method was developed to obtain transient burnout conditions at the exit. A simple correlation to predict the deviation of the transient burnout mass velocity at the tube exit from the steady state mass velocity obtained as a function of steam-water density ratio and flow reduction rate. The correlation was also compared with the other data. (author).

327

Tracheal laceration during intubation of a double-lumen tube and intraoperative fiberoptic bronchoscopic evaluation through an LMA in the lateral position -A case report-  

UK PubMed Central (United Kingdom)

A 76-year-old, 148-cm woman was scheduled for right upper lobectomy. A 32 Fr left-sided double lumen tube was placed using a conventional technique. Despite several attempts under fiberoptic bronchoscope-guidance,...Full Text Available

2011-04-01

328

Thermal/hydraulic tests of tube supports in a multi-tube steam generator model  

International Nuclear Information System (INIS)

Tube supports used in the tube bundles of PWR steam generators have consisted of mechanical devices located at intervals along the tube bundle. The presence of tube supports creates regions of restricted flow with altered flow patterns and increased pressure drop. An additional and very important effect is also the possibility of local complete vaporization or dryout occurring in the tube/support flow passage and crevices. The thermal/hydraulic conditions at which dryout occurs are of particular interest because of the possibility of the deposition of dissolved solids with the occurrence of dryout. As long term build-up of solid deposition could have a deleterious effect, knowledge of the conditions at which dryout occurs would possibly provide a means to avoid this build-up. A test program, sponsored by the Steam Generator Project Office of the Electric Power Research Institute, ...

1985-03-01

329

Steam generator design improvements for the candu wolsung nuclear power plant  

International Nuclear Information System (INIS)

Design considerations are given for the secondary side region of a vertical U-tube nuclear stream generator with an integral preheater. The thermal shield design, the novel recirculating water flow distribution scheme, the high porosity tube supports used in the parallel flow regions, and the U-bend supports are discussed for the Wolsung Plant steam generators. Experimental and analytical development programs undertaken to verify the design features are outlined.

1978-01-01

330

Simultaneous absolute and differential operation of eddy current bobbin probes for heat exchanger tube inspection  

Energy Technology Data Exchange (ETDEWEB)

Here the authors try to dissolve some commonly held misconceptions about the operation of eddy current probes used for inspecting heat exchanger tubes. With the help of computer model results, the authors demonstrate that, for optimized operation, absolute/differential probes should be operated with coil current flowing in phase with another. This month's feature should be of interest to researchers as well as for NDT field personnel.

2000-05-01

331

Radiative Heat Transfer Augmentation in High Temperature Combustion Systems with Application to Radiant Tube Burners. Final Report, April 1987-March 1990.  

Science.gov (United States)

Gas fired radiant tube heaters provide an indirect heating source for applications in which direct contact cannot be permitted between combustion gases and the workpiece. The program was an investigation of ways to improve performance of such burners thro...

1990-01-01

332

PWR steam generator chemical cleaning process  

International Nuclear Information System (INIS)

Some of the origins of corrosion encountered in the secondary side of pressurized water reactor steam generators are:-sludge accumulation (a mixture of metal oxides, primarily magnetite and copper) on tube sheet and attack of tube support plates by aggressive impurities leading to denting. Although Electricite de France has not suffered from these problems, it has developed a chemical cleaning process to dissolve corrosion products at both locations. (author).

1986-10-13

333

Markets for clean energy  

Wastenet

... The products can be categorised as glazed flat-plate collectors, evacuated glass-tube collectors, and unglazed plastic or low temperature collectors. Glazed flat-plate collectors and vacuum tubes are widely used for solar water heating and space heating systems in all types of buildings. Unglazed plastic collectors are used exclusively for lower temperature applications, such as outdoor swimming pools or the agrarian business. Flat-plate solar collectors are likely to ...

334

Manual corrosion  

Energy Technology Data Exchange (ETDEWEB)

In the aim to fight against tubes corrosion of geothermal wells which exploit the aquifer of Dogger reservoir in the Parisian basin, injection of corrosion inhibitors in the geothermal fluid has been generalized since 1989 by using an additive injection tube in the bottom of the well, allowing the protection of the two wells from the geothermal doublet. 3 annexes. 46 refs. 13 tabs. 9 figs.

1994-09-01

335

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

Energy Technology Data Exchange (ETDEWEB)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A{sub 1}) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs{sub eff}). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A{sub 2}). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube ...

2003-12-01

336

Individually weight-adapted examination protocol in retrospectively ECG-gated MSCT of the heart  

International Nuclear Information System (INIS)

The standard protocol in multislice spiral CT (MSCT) angiography for coronary arteries with fixed tube current-time settings leads to an overexposure and thus to an unnecessary high radiation dose in patients with lower weight when compared to heavier patients. The purpose of this study was to estimate the effect of reducing the radiation dose by adapting the tube current-time settings individually. Fifty patients underwent retrospectively ECG-gated MSCT of the heart. In 25 patients (group A_1) a standard protocol with constant tube current-time settings was used (4 x 1-mm collimation, 120 kV, 400 mAs_e_f_f). Subsequently, artificial image noise was added to the data of these patients simulating a directive for weight-adapted tube current-time settings (group A_2). In the other 25 patients (group B) an alternative protocol with individually weight-adapted tube current-time settings ...

2003-12-01

337

Esophageal perforation following bite of inner tube of automobile tyre: An unusual cause of barotrauma  

UK PubMed Central (United Kingdom)

An 8-year-old child presented with severe chest pain and respiratory distress after he accidentally bit an automobile tyre tube which burst into his mouth. The chest radiograph revealed left-sided pneumothorax....Full Text Available

2010-01-01

338

Energy conservation via heat transfer enhancement. Quarterly progress report, October 1-December 31, 1979  

Science.gov (United States)

Contacts with researchers, manufacturers, and users of enhanced heat transfer equipment are summarized. The Technical Literature file and the Patent File continue to be updated; the Patent File is the source for a patent technology report now in draft form. Application studies on a rationally-based friction correlation for internally-finned tubes and on the evaluation of candidate tube-side enhancements for OTEC applications are reported. The technology study on enhancement of spray evaporation is also discussed.

1979-01-01

339

Effective stress of a 4.2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall`s resistivity requirement ({sigma}*t = 2E5 {Omega}{sup {minus}1}). For a 4.2 K beam tube the Cu thickness is 100 {mu}m (RRR=30,6.7 T, {sigma}=2E9{Omega}{sup {minus}1}m{sup {minus}1}). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam tube ...

1993-05-01

340

Effective stress of a 4. 2 K beam tube in a quenching collider 50 mm dipole magnet for the SSC  

Energy Technology Data Exchange (ETDEWEB)

Two mechanical design requirements are defined for the SSC Collider beam tube. First, the vacuum requirement (luminosity lifetime = 150 hrs). It requires the design of a pressure boundary within the cold mass vessel to provide a vacuum tunnel for the proton beam and to minimize the synchrotron radiation gas desorbtion with a suitable material. The Collider beam tube design is under an intensive activity to search for a material that will meet the luminosity requirement without a distributed pump or liner. Second is the tube wall's resistivity requirement ([sigma]*t = 2E5 [Omega][sup [minus]1]). For a 4.2 K beam tube the Cu thickness is 100 [mu]m (RRR=30,6.7 T, [sigma]=2E9[Omega][sup [minus]1]m[sup [minus]1]). The copper yield strength is relatively low in comparison to steel and, therefore, the design of the steel layer is governed by the copper layer yield stress limit. A beam ...

1993-05-01

341

Condenser replacement at Unterweser nuclear power station  

International Nuclear Information System (INIS)

In spite of extensive cooling water studies premature damage due to corrosion occurred on the CuZn20Al condenser tubes. It was then decided to incorporate new titanium-tubed condensers during the annual overhauls of 1983 and 1985 and also take ameliorating measures up to the exchange of individual condensers. (orig.).

342

CERAMIC MEMBRANES FOR HYDROGEN PRODUCTION FROM COAL  

Energy Technology Data Exchange (ETDEWEB)

The preparation and performance of membranes for application to hydrogen separation from coal-derived gas is described. The membrane material investigated was dense amorphous silica deposited on a suitable support by chemical vapor deposition (CVD). Two types of support materials were pursued. One type consisted of a two-layer composite, zeolite silicalite/{alpha}-Al{sub 2}O{sub 3}, in the form of tubes approximately 0.7 cm in diameter. The other type was porous glass tubes of diameter below 0.2 cm. The first type of support was prepared starting from {alpha}-Al{sub 2}O{sub 3} tubes of 1{micro}m mean pore diameter and growing by hydrothermal reaction a zeolite silicalite layer inside the pores of the alumina at the OD side. After calcination to remove the organic template used in the hydrothermal reaction, CVD was carried out to deposit the final silica layer. CVD was carried out by alternating exposure of the surface with ...

2004-04-01

343

Bounding ingestion stream-tube determination via a CO tracer  

Energy Technology Data Exchange (ETDEWEB)

A gas tracer technique based on carbon monoxide and a commercial automotive exhaust gas analyser has been applied to wind tunnel models of waterjet propulsion systems intakes. The post-processing and interpretation of the carbon monoxide concentration signals has yielded high resolution measurements of the bounding ingestion stream-tubes. (orig.) With 3 figs., 1 tab., 8 refs.

1998-05-01

344

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

Energy Technology Data Exchange (ETDEWEB)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-07-01

345

Aerosol deposition in horizontal steam generator tubes in severe accident conditions  

International Nuclear Information System (INIS)

The understanding of fission product deposition in realistic steam generator conditions is needed for release estimates in PSA studies, and for the design of efficient accident management procedures. This is considered very important because primary-to-secondary leakages risk dominant sequences in many plants. Furthermore, the decay heat of the fission product deposits adds to the thermal load to the steam generator tubes also in other sequences, especially in case of cold leg leakages. This brings out the concern of induced steam generator tube ruptures in cases, where the steam generators are initially intact. The experimental data showed that the highest deposited fraction within the tubes were found in cases with lowest flow velocities. The minimum value of the deposited fraction was observed at intermediate flow velocities. With these relatively low Reynolds numbers, the results calculated with deposition models agree ...

2003-10-05

346

Advances in enhanced heat transfer: 1987  

Energy Technology Data Exchange (ETDEWEB)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-01-01

347

Advances in enhanced heat transfer: 1987  

International Nuclear Information System (INIS)

This book contains nine selections. Some of the titles are: High Heat-Flux, Forced-Convection Heat Transfer for Tubes with Twisted-Tape Inserts; Heat Transfer Augmentation by Interrupted Surfaces - Experimental Consideration; Turbulent Flow Heat Transfer from Externally Roughened Tubes in Axial Flow in Concentric Pipe Heat Exchangers; and Heat Transfer Enhancement of Turbulent Flow in Pipes with an Internal Circular Rib.

1987-08-09

348

Serviceability of steam generators at NPPs with reactors of the WWER-440 and WWER-1000 types  

Energy Technology Data Exchange (ETDEWEB)

Steam generators (SG) are the weak link of nuclear power plants, their service life is shorter than the service life of other NPP components. This paper is dedicated to a statistical analysis of SG damages and failures. Heat exchanging tubes (HET) are the most damaged elements in SG, there are on average 286 plugged or repaired tubes in each operating SG. The usually mechanisms of tube failure are the following: denting, corrosion at tube outside, pitting, fretting, and circular crack propagation. Most of damages are located in the transition zone above a tube plate. This study shows that the factors that are involved in the SG HET fault probability are: - design features of SG and secondary equipment elements (high pressure feed heaters (HPFH), low pressure feed heater (LPFH)), - water chemistry at different points of condensate feed pipe, composition and density of deposits on HET ...

2002-07-01

349

Processing fine-grained and superplastic AZ31 Mg tubes for hydroforming  

Energy Technology Data Exchange (ETDEWEB)

The microstructures and mechanical properties of the AZ31 Mg tubes fabricated by one-pass forward piercing tube extrusion operated at 250-400 C and 10{sup -2}-10{sup 0} s{sup -1} are examined. The grain size is refined from the initial {proportional_to}75 {mu}m grain size down to {proportional_to}1.5 {mu}m. The room temperature tensile elongation along the extrusion direction also increases from {proportional_to}13% for the as-received billet up to 51%. The highest superplastic elongation of 610% was obtained as tensile loaded at 300 C and 2 x 10{sup -4} s{sup -1}, and high strain rate superplasticity of 406% and 502% was achieved at 300 C and 400 C with a high strain rate of 1 x 10{sup -2} s{sup -1}. Preliminary hydroforming or tube bulging at room temperature has demonstrated the feasibility. Hydroforming at elevated temperature of 200 C or above should exhibit much more promising results, utilizing the capability of LTSP ...

2004-07-01

350

Prevention of pitting corrosion on copper tubes in central hot water supply systems by UV photochemical decomposition of residual chlorine  

Energy Technology Data Exchange (ETDEWEB)

After confirming that residual chlorine in tap water, which is regarded as one of the major cause of pitting corrosion, can be decomposed/removed by the irradiation of UV light, effect of dechlorinated water obtained based on this principle on the prevention of pitting corrosion, generation and growth, of the copper tubing was investigated by a corrosion test simulated the actual system in high buildings. (1) Low pressure type mercury lamp easily decompose/remove the residual chlorine. (2) If the dechlorinated water is supplied from the initial stage of copper tube usage, potential of the copper tube remains at the level of 100 mV/SCE and the generation of pitting corrosion is not observed. (3) Even when pitting corrosion is already found, switching to dechlorinated water in the midway reduces the potential of the copper tube down to 50 - 70 mV level, at the same time completely restricting the growth ...

1988-03-25

351

Pitting corrosion of copper coiled tubes in the air conditioning system having the open heat storage water tank; Kaihokei chikunetsuso reionsuika ni okeru kuchokiyo kokan no koshoku ni tsuite  

Energy Technology Data Exchange (ETDEWEB)

In order to investigate pitting corrosion of copper coiled tubes for air conditioning systems with an open heat storage water tank, the effect of carbon films on the inner surface of copper tubes and fine corrosion-product particles in water as environmental corrosion factor on pitting corrosion was studied by field test under real environmental conditions. As a result, pitting corrosion of copper tubes was caused by synergistic effect of fine corrosion-product particles in water and carbon films. Generation of pitting corrosion was derived from deposition of the films and particles, while considerable growth of pitting corrosion was dependent on the particles. Time variation of spontaneous electrode potential also showed the effect of the film and particle. Pitting corrosion potential was estimated to be nearly 100mV vs. SCE. The following measures against pitting corrosion were considered to be effective: (1) Removal of ...

1998-11-15

352

Measurement of reactor tube cladding thickness by x-ray fluorescence spectrometry  

International Nuclear Information System (INIS)

An x-ray fluorescence spectrometer was designed and fabricated which nondestructively determines the thickness of aluminum cladding at small suspected thin spots in the inner or outer surface of actinide reactor tubes. The analysis method is based on the difference in absorption of actinide L/sub #alpha#/ and L/sub #beta#/ fluorescent x-rays in passing through the cladding. Calibration plots of the logarithm of the L/sub #beta#//L/sub #alpha#/ x-ray intensity ratio versus cladding thickness are linear to at least 40 mils for U-Al, U_3O_8-Al, and PuO_2-Al substrates. Accuracy and precision of the experimentally determined cladding thickness and evaluated for both uranium and plutonium substrates. Experimental thickness data are reported for 618 quality assurance analyses on six Mark 41 PuO_2-Al target tubes. An x-ray fluorescence cladding thickness monitor operated with a computer-controlled fluoroscope holds considerable promise for quality ...

1978-01-01

353

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

Energy Technology Data Exchange (ETDEWEB)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2006-07-01

354

Field experience with eddy current X-probes in CANDU steam generators and heat exchangers  

International Nuclear Information System (INIS)

CANDU steam generators and heat exchangers have been afflicted with a significant variety of degradation mechanisms. Until recently, detection and characterization of most of the varieties of flaws required usage of several different eddy current techniques. Tubes needed to be scanned multiple times to ensure they were inspected for all possible degradation mechanisms. The time required to deploy so many different types of techniques to inspect the steam generator tubes has had a significant impact on the inspection schedules. The X-Probe was designed with an array of eddy current coils capable of detecting, characterizing and sizing axial, circumferential and volumetric flaws. The X-Probe is a fast-scanning probe with scanning speed equivalent to speeds typically used for simple bobbin coil probes. With its capability of fulfilling most if not all of the functions of the other tube-testing eddy current probes, it can ...

2005-11-20

355

Determination of water level profile along heat exchange tubes of horizontal steam generator PGV 1000 M  

International Nuclear Information System (INIS)

A mathematical model is described for determining the level profile along the length of heat exchange tubes in a horizontal steam generator, and for determining the conditions in the steam cushion under the perforated sheet. The water level area is divided in the model into 36 partial elements; for analysis of the conditions under the level, the steam-water space is divided into four areas. The results of the calculations were compared with measurement results for the steam generator rated values. Very good agreement was found. The results show that, among others, the supply water distribution very much affects the conditions in the area of the steam cushion and of the bubble vacuum. Also, the average steam load of the inner bundle tubes is significantly higher than that of the outer bundles. It was also shown that permanent steam generator operation with exposed top tube rows may occur even in some permissible operating ...

356

Augmentation of heat transfer in a tube with an oscillating thin plate. Shindohen sonyu ni yoru enkannai netsudentatsu sokushin  

Energy Technology Data Exchange (ETDEWEB)

An attempt is made to augment the heat transfer efficiency by means of inserting an oscillating thin plate into a tube of the shell and tube heat exchanger. However, the heat transfer augmenting mechanism has not been fully explained. To elucidate this heat transfer augmenting mechanism, an investigation was given on the heat transfer characteristics of a tube inlet at its preliminary run area when a double-hinged oscillating thin plate is inserted in the inlet. As a result of the experiment, the heat transfer augmentation in the tube as a result of inserting the double-hinged oscillating thin plate was found effective when the preliminary inlet run area is treated as the object. However, in comparison of the effect with the heat transfer in a fully developed turbulent region, it was {eta}- 1. The result thus obtained explains that no sufficient turbulence can be obtained when the deflection angle of ...

1991-09-01

357

Utility activities that create power quality problems  

Energy Technology Data Exchange (ETDEWEB)

Power quality problems are caused by activities normal to utility operations such as maintenance outages and capacitor switching or events that are abnormal such as lightning strikes and equipment failures. Disconnection and reconnection of transmission lines and transformers can cause switching surges, and are more severe on extra high voltage transmission lines than high voltage lines. Capacitor switching can cause transients and harmonics that may affect sensitive equipment, and are the source of 3rd, 5th, 7th and 9th harmonics in the hundreds of hertz ranges. Overload, sudden loss of generating capacity and transmission line faults are typical problems affecting system stability. Fault interruptions and reclosings can cause surges in the distribution system, and lightning strikes may cause voltage surges or dips due to arrester sparkover. Blackouts, brownouts, voltage fluctuations, travelling wave ...

1992-02-01

358

Underground cable: Best for cogeneration links  

Energy Technology Data Exchange (ETDEWEB)

This article addresses the connection of cogeneration plants to the utility system. The article provides examples for use in illustrating the problems that must be overcome and the solution chosen. These illustrations include high voltage utility connection, multiple connections to the utility at one location, and dealing with losses and obstructions.

1989-05-01

359

The influence of electromagnetic field irradiated by high-voltage transmission lines on properties of cells.  

Science.gov (United States)

The influence of low-frequency electromagnetic field irradiating by high-voltage transmission lines on signal transduction of cell in spleen cells of the rates have been studied by molecular-biology techniques. The spleen cells are extracted from skilled rates, which are exposed in the electromagnetic field of high-voltage transmission lines with 4000 V/m and 0.09-0.1 G about 400 days. The quantity or level of phosphorylation of signal transducer and activator of transcription (STAT3) in JAK-STAT signal transduction pathway of spleen cells, which are stimulated and unstimulated by IL-2, respectively, are detected by the immunoblotting and immunobiochemistry. The results show that the expression of phospho-STAT3 in spleen cell stimulated by IL-2 differ not from that in the unstimulated cell. The former is significantly large than the latter. This shows that signal transduction of cell is affected by this electromagnetic field. The spectra of ...

2005-01-01

360

The Antibacterial Activity of Human Neutrophils and Eosinophils Requires Proton Channels but Not BK Channels  

UK PubMed Central (United Kingdom)

Electrophysiological events are of central importance during the phagocyte respiratory burst, because NADPH oxidase is electrogenic and voltage sensitive. We investigated the recent suggestion that...Full Text Available

2006-06-01

361

Temperature-induced opening of TRPV1 ion channel is stabilized by the pore domain  

UK PubMed Central (United Kingdom)

SummaryTRPV1 is the founding and best-studied member of the family of temperature-activated transient receptor potential ion channels (thermoTRPs). Voltage, chemicals, and heat...Full Text Available

2010-06-01

362

Study on vibration of transmission lines when gust is blowing (an interim report); Kyofuji no haiden senro no yodo ni kansuru kenkyu  

Energy Technology Data Exchange (ETDEWEB)

As an interim report on the study on vibration of transmission lines when gust is blowing, this paper introduces events of confused and other contacts between transmission lines, photographing of transmission line vibration, physical measurement on transmission line response, and development of simulation software. Events of confused contacts of high-voltage transmission lines with overhead ground wires have the following common conditions: gust blows nearly perpendicularly to the line direction; no obstacles exist in upwind directions; the wind blows upward or downward against high-voltage transmission lines; and size of the high-voltage transmission lines is 25 mm{sup 2}. According to photographs of transmission line vibration, it appears that gust caused a high-voltage transmission line on the upwind side to jump resulting in confused contact with the overhead ground wire. The physical measurement ...

1996-03-25

363

Single Molecule Source Reagents for CVD of Beta Silicon Carbide.  

Science.gov (United States)

Beta silicon carbide is an excellent candidate semiconductor material for demanding applications in high power and high temperature electronic devices due to its high breakdown voltage, relatively large band gap, high thermal conductivity and high melting...

1991-01-01

364

Risk of hematological malignancies associated with magnetic fields exposure from power lines: a case-control study in two municipalities of northern Italy  

UK PubMed Central (United Kingdom)

BackgroundSome epidemiologic studies have suggested an association between electromagnetic field exposure induced by high voltage power lines and childhood leukemia, but null results...Full Text Available

365

Regulation of ROMK1 Channels by Protein-tyrosine Kinase and -tyrosine Phosphatase*  

UK PubMed Central (United Kingdom)

We have used the two-electrode voltage clamp technique and the patch clamp technique to investigate the regulation of ROMK1 channels by protein-tyrosine phosphatase (PTP) and protein-tyrosine...Full Text Available

2001-03-09

366

Probing the Mechanisms of an Air Amplifier using a LTQ-FT-ICR-MS and Fluorescence Spectroscopy  

UK PubMed Central (United Kingdom)

We report the first quantitative assessment of electrosprayed droplet/ion focusing enabled by the use of a voltage-assisted air amplifier between an electrospray ionization emitter and a hybrid...Full Text Available

2007-11-01

367

Pore region of TRPV3 ion channel is specifically required for heat-activation  

UK PubMed Central (United Kingdom)

Ion-channels can be activated (gated) by a variety of stimuli including chemicals, voltage, mechanical force or temperature. Whereas molecular mechanisms of ion-channel gating by chemicals and...Full Text Available

2008-09-01

368

Penny Battery  

Science.gov (United States)

In this activity, learners light an LED with five cents. Learners use two different metals and some sour, salty water to create a cheap battery. Learners also have the option of checking the voltage of their battery if a voltmeter is available.

369

NOVEL EMBEDDED CERAMIC ELECTRODE SYSTEM TO ACTIVATE NANOSTRUCTURED TITANIUM DIOXIDE FOR DEGRADATION OF MTBE  

Science.gov (United States)

A novel reactor combining a flame-deposited nanostructured titanium dioxide film and a set of embedded ceramic electrodes was designed, developed and tested for degradation of methyl tert-butyl ether (MTBE) in water. On applying a voltage to the ceramic electrodes, a surface coro...

370

Life estimation of high-voltage electric cable. Koden prime atsu cable no jumyo yosoku  

Energy Technology Data Exchange (ETDEWEB)

An explanation is given of life estimation of CV cable and OF cable which are generally used as high-voltage power cable. CV cable uses XLPE (crosslined polyethylene) and OF cable uses oil-immersed paper as electrical insulators. Relating to CV cable, voltage deterioration due to partial discharge and electric treeing occurs in a high electric field, and by extrapolating the data of up to the actually used electric field in this high electric field, the life is estimate (there is an n-power deterioration law which is V{sup n} = t between breakdown voltage V and electric applied time t). Validity of this extrapolation, however, is a future issue. Further, in the use under the immersion condition, water tree deterioration phenomena influenced by water content and the electric field which are characteristic of CV cable are seen even in the actually used low electric field, and the life index becomes considerably small. ...

1991-12-15

371

Induced current switching development work for the application of ground interrupter switches on the Hydro-Quebec H.V. system  

Energy Technology Data Exchange (ETDEWEB)

Phenomena associated with induced currents and voltages on high voltage transmission lines were discussed. Basic principles were reviewed. Action taken by Hydro-Quebec to assess the importance of associated problems on its grid was described. Hydro-Quebec`s findings and recommendations were compared with those of the International Standard, IEC 1129. It was concluded that for most cases, induced currents and voltages were higher than those listed under Class A recommendations of IEC 1129 as rated switching capabilities for ground switches assigned to this duty. For worst case scenarios, it was also found that, values of induced currents and voltages were lower than those of Class B recommendations. Hydro-Quebec and GEC Alsthom T and D collaborated to design and type test a full range of low cost and efficient ground interrupter switches tailored to Hydro-Quebec`s needs. A list of general application ...

1995-12-31

372

Formation of the electret state of polymers in a gas discharge plasma  

Science.gov (United States)

The present article studies the electret state of polymers when moving through an alternating-current corona discharge plasma and investigates means for the determination of the transition of the polymeric material from the initial state of the electret when the corona-displaying voltage is increased.

1983-02-01

373

Electric field measurement on time domain generated by corona on insulators on distribution systems  

Energy Technology Data Exchange (ETDEWEB)

Radio interference and TV interference are being a problem in urban and rural areas. This interference is generated by high voltage transmission lines as well as distribution lines. The radio noise can be produced by polluted or damaged insulators, and by metal parts of the distribution lines. The corona effect on the surface of the dielectric material produces high frequency electromagnetic fields during the ionization and during the recombination period. Fields of different intensity are produced by positive voltage and negative voltage. The insulator flashover (leaking current) also produces electromagnetic fields. A new technique to measure these fields was developed. This technique measures the radiated fields on time domain and on frequency domain. This permits us to characterize the radiated field and thus identify the type of the source. Several measurements were done varying the type of the RF generator, i.e., new ...

1996-12-31

374

Voltage-current characteristics of point systems of metal-oxide-metal  

Science.gov (United States)

A detection theory is developed for point-contact metal-oxide-metal (MOM) systems. A system with heterogeneous oxide strongly bonded to the substrate is considered. It is shown that the form of the functional connection between the barrier heights and the ultimate compressive strength of the oxide has no substantial influence on the voltage-current characteristics of the system. Quantitative analysis indicates that a MOM system can behave as a tunnel diode and as a diode with a Schottky barrier. The model permits the determination of the optimum construction of long-life detectors based on MOM point-contacts.-

1975-10-01

375

RATIO COMPUTER  

Science.gov (United States)

An electronic computer circuit is described for producing an output voltage proportional to the product or quotient of tbe voltages of a pair of input signals. ln essence, the disclosed invention provides a computer having two channels adapted to receive separate input signals and each having amplifiers with like fixed amplification factors and like negatlve feedback amplifiers. One of the channels receives a constant signal for comparison purposes, whereby a difference signal is produced to control the amplification factors of the variable feedback amplifiers. The output of the other channel is thereby proportional to the product or quotient of input signals depending upon the relation of input to fixed signals in the first mentioned channel.

1958-11-11

376

Power cables: methods of defects localization; Cables d'energie: methodes de localisation des defauts  

Energy Technology Data Exchange (ETDEWEB)

The defects localization in power cables follows several steps: identification, pre-localization and precise localization. Pre-localization methods, other than echo-metry, are presented first: bridge methods, particular case of low voltage networks, future perspectives. Then, the precise localization methods are described: magneto-acoustic method, audible frequencies method. The particular case of underwater and high-voltage cables is considered too (oil and gas leaks detection). (J.S.)

2006-08-15

377

Passivation-free solid state battery  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to passivation-free solid-state rechargeable batteries composed of Li.sub.4 Ti.sub.5 O.sub.12 anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn.sub.2 O.sub.4, LiCoO.sub.2, LiNiO.sub.2 and LiV.sub.2 O.sub.5 and their derivatives.

1998-01-01

378

Passivation-free solid state battery  

Energy Technology Data Exchange (ETDEWEB)

This invention pertains to passivation-free solid-state rechargeable batteries composed of Li{sub 4}Ti{sub 5}O{sub 12} anode, a solid polymer electrolyte and a high voltage cathode. The solid polymer electrolyte comprises a polymer host, such as polyacrylonitrile, poly(vinyl chloride), poly(vinyl sulfone), and poly(vinylidene fluoride), plasticized by a solution of a Li salt in an organic solvent. The high voltage cathode includes LiMn{sub 2}O{sub 4}, LiCoO{sub 2}, LiNiO{sub 2} and LiV{sub 2}O{sub 5} and their derivatives. 5 figs.

1998-06-16

379

Low-frequency fields - sources and exposure  

International Nuclear Information System (INIS)

The author briefly discusses definition of terms, gives an introduction to measurement techniques and describes the characteristics of various low-frequency fields and their causes using typical examples: natural electric fields (thunderstroms), natural magnetic fields, technical electric constant fields (urban transportation, households), static magnetic fields (urban transportation, nuclear magnetic resonance imaging), technical electric alternating fields (high-voltage transmission lines, households), and magnetic alternating fields (high-voltage transmission lines). The author discusses both occupational exposure and that of the general public while underpinning his statements by numerous tables, measurement diagrams and charts. (Uhe).

1993-06-01

380

High voltage transmission lines - what are the hazards  

International Nuclear Information System (INIS)

With the increasing use of high voltage alternating current (HVAC) transmission lines there is a growing concern among the public about possible human health effects resulting from exposure to the electric fields associated with these lines. While there is no definitive evidence of such effects, mounting public fear and activism over hypothesized health risks is already causing delays in the licensing and constuction of major power transmission facilities, and is encouraging the formation of regulatory policy. This paper briefly reviews the concerns, biological effects data and standards for HVAC transmission lines.

1984-07-01

381

Gaseous dielectrics V  

Energy Technology Data Exchange (ETDEWEB)

This book discusses the progress and problems of current interest in gaseous dielectrics and their use, with special emphasis on insulation in high-voltage transmission lines and substations. Topics covered include: basic physics of gaseous dielectrics; basic mechanisms; gas decomposition, reactions and toxicity; diagnostics and field probes; gases and mixtures for GIS transformers and circuit breakers; gaseous media for discharge chemistry and etching/corona; gas engineering for pulsed power and switching; gas breakdown under steep-fronted voltages; new developments in gas-insulated equipment and gas handling; gas/insulator interface/flashover; and quality control in testing gas-insulated equipment. Contains approximately 85 papers.

1987-01-01

382

Electric induction on a trolley bus contact line, running parallel to a 138 KV overhead transmission line; Inducao em linha de contato de trolebus paralela a uma linha de transmissao de 138 kV  

Energy Technology Data Exchange (ETDEWEB)

Results obtained on induced current and voltage caused by a high voltage transmission lines running parallel at a trolley bus contact lines, are presented. A computer program in Basic language, was developed to calculate the electric induction, problems of safety, a theoretical development and mathematical model of the electric factors between two lines (inductor and induced) are also discussed. 11 figs., 1 tab., 8 refs.

1991-12-31

383

Control device of a high voltage circuit breaker equipped with closing resistors  

Energy Technology Data Exchange (ETDEWEB)

A high voltage self-blowing circuit breaker with closing resistors is equipped with an auxiliary contact inserted in the trip control circuit of an electrical circuit breaker. The auxiliary contact is actuated by the mechanical control rod of the circuit breaker in such a way as to prevent any operator closing error. A high-speed mechanism is inserted in the link system connecting the control rod and the auxiliary contact, with dead travel to delay closing of the auxiliary contact when a closing operation takes place and to prevent a tripping order from being transmitted too early. Such an early transmission would be liable to cause a flashover on the inserter contacts and damage to the circuit breaker.

1991-02-12

384

Back-up for high voltage cable pressurizing system  

Energy Technology Data Exchange (ETDEWEB)

A back-up system is provided for a pumping plant or a pressure reservoir system used to maintain insulating oil under pressure in high voltage submarine power cables which includes a gas driven membrane pump to insure a small outflow of oil at a rupture point in the power cable to prevent water from penetrating the cable. The proper operation of the membrane pump is insured by introducing degasified oil at the drive side of the pump during the stand-by and test modes of operation of the back-up system. 11 drawings.

1982-07-19

385

A robust cell voltage monitoring system for analysis and diagnosis of fuel cell or battery systems  

Energy Technology Data Exchange (ETDEWEB)

Cell voltage monitoring (CVM) systems are essential for the operation of fuel cell stacks and some battery systems, in the field as well as in the laboratory, because they allow the diagnosis and correction of problems that would otherwise go unnoticed and cause impaired performance or even permanent damage. A robust, safe, and low-cost design for a CVM unit is presented, using electromechanical relays as multiplexing switches. Some examples from the application of the unit on the University of Delaware's fuel cell battery hybrid buses are presented, including its use in automatically correcting anode flooding and diagnosing air channel blockage. (author)

2010-12-15

386

A photoelectrochemical investigation of passive films formed by alternating voltage passivation  

Energy Technology Data Exchange (ETDEWEB)

Photocurrent measurements for stainless steel type 304 in the as-received condition after dc and AV (alternating voltage) passivation have confirmed that significant changes of the passive film properties occur due to AV passivation. The photocurrents were the highest for the sample treated by the AV passivation process (AVPP). The bandgap energy increased from about 2.8 to about 3.05 eV for this treatment. Very similar results have been obtained for pure chromium, which suggests that the AVPP produces a thicker passive film with a less defective nature due to a partial dehydration of the chromium oxide phase in the film.

1993-07-01

387

Assessment of audible noise from high voltage transmission lines and a high voltage transformer station  

Energy Technology Data Exchange (ETDEWEB)

The study of audible noise from high voltage transmission lines and a high voltage transformer station was conducted in three parts. Part 1 consisted of long-term measurement and statistical analysis by computer reduction of audible noise as a result of corona discharge from high voltage transmission lines and the associated weather conditions which contribute to this noise. Recommendations are given concerning further computer programming in order to improve the statistical reliability of corona noise presence and reduce the degree of background noise contamination of the present results. Part 2 consisted of categorizing and cataloguing of corona noise spectra from long-term measurements on 550, 735 and 765 kV transmission lines and to provide a library of such sounds on magnetic tape to be used in the ongoing study of corona noise. Twenty-five different corona sound spectra have been identified and documented in a tape ...

1986-11-01

388

Ultra-high temperature strength properties on Mod.9Cr-1Mo steel  

Energy Technology Data Exchange (ETDEWEB)

A sodium-water reaction drove from the single tube break in steam generator of FBR might overheat labor tubes rapidly under internal pressure loadings. If the temperature of tube wall becomes too high, it has to be evaluated that the stress of tube does not exceed the material strength limit to prevent the propagation of tube rupture. This study clarified the tensile and creep properties of Mod.9Cr-1Mo steel at ultra-high temperature which will be used in evaluation of the tube burst by sodium-water reaction. The strain rates for tensile test are from 10%/min to 10%/sec, and creep-rupture time is maximum 277sec. The range of test temperature is 700degC to 1300degC. The main results obtained were as follows; (1) The evaluation data on the relationship between tensile strength and strain rate and creep-rupture strength in shorter time on Mod.9Cr-1Mo steel were ...

2000-03-01

389

The Cause of an Eddy Current Signal Noise from a Steam Generator Tube and its Effect on the Detectability of a Crack  

International Nuclear Information System (INIS)

An eddy current inspection has been applied for a pre-service and in-service examination of a steam generator in nuclear power plants. The experience from the inspection of steam generators showed that many plants had an excessive number of tubes with eddy current noise signals over several hundreds, which originated from manufacturing anomalies. The plants in U.S suffered significant downstream inspection costs, history reviews, and diagnostic testing because some signals resembled flaws and others masked a flaw. These lessens learned resulted in issuing the guidelines for steam generator tubing specifications and repair, in order to reduce the number of anomalous signals in the tubes and also to provide the requirement of a signal to noise ratio by applying a field type examination with bobbin coil eddy current probes at a manufacturing process. Besides the noise signals of a bobbin coil eddy current probe from ...

2008-05-01

390

Predicting optimum vortex tube performance using a simplified CFD model  

International Nuclear Information System (INIS)

The Ranque-Hilsch tube is a particular type of vortex tube device. The flow enters the device tangentially near one end and exits from the open ends of the tube. The inlet air is of a uniform temperature throughout while the outputs are of different temperatures. One outlet is hotter and the other is colder than the inlet air. This device has no moving parts and does not require any additional power for its operation other than that supplied to the device to compress the inlet air. It has, however, not been widely used, mainly because of its low efficiency. In this paper, a simplified 2-dimensional computational fluid dynamics model for the flow in the vortex tube is developed using FLUENT. This model makes use of the assumption of axial symmetry throughout the entire flow domain. Compared to a three-dimensional computational solution, the simplified model requires significantly less computational time. ...

2004-05-09

391

Fracture inspection by BHTV logging through a vinyl chloride tube; Enbi pipe ga sonyusareta kosei deno BHTV ni yoru kiretsu chosa  

Energy Technology Data Exchange (ETDEWEB)

A borehole televiewer (BHTV) logging was conducted to investigate cracks in bored wells. The logging process shoots ultrasonic waves onto bore walls and utilizes reflection waves from the bore walls. If the bores are filled with muddy water, or the ultrasonic waves can pass through even if vinyl chloride tubes have been inserted after excavation, the state of the bore walls can be investigated in principle. Conventional optical scanners are, however, incapable of making this investigation. The BHTV logging can be used for identifying lithofacies from reflection intensities from bore walls (it depends on sound impedance of rocks), not to speak of finding cracks. As a result of making logging upon setting time windows from 105 to 145 {mu} sec in a bored well inserted with a vinyl chloride tube, cracks in the bore wall were identified clearly through the vinyl chloride tube. If the distance between the bore wall and the vinyl ...

1997-05-27

392

Application of new corrosion-resistance superheater tubings for a 500 C, 100 Kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy plant  

Energy Technology Data Exchange (ETDEWEB)

A two-year demonstration run of a 500 C/100kgf/cm{sup 2}{center_dot}g high-efficiency waste-to-energy pilot plant has been started from February 1998; this plant represents as the final stage of the NEDO project of development of a high-efficiency waste-to-energy plant. Alloy 625 (SB444) and 310 HCbN tubings were selected for the 3rd and 2nd superheater of the pilot plant, respectively, and ten kinds of conventional and new solid-wall tubings, weld overlayed tubings, composite tubings, and cermet spray coated tubings were tested. By means of 6000-hour field corrosion test in three typical domestic plants, material life and corrosion environment for superheater tubings installed in the pilot plant were evaluated. Also, the effect of alloying elements Cr, Ni, Mo, corrosion rate law, etc. were investigated in detail. Furthermore, the design conception and basic ...

1999-11-01

393

Analysis of defect detection in steam generator tubes of FBR, under support plates and in the presence of sodium using multi-frequency eddy current algorithms  

International Nuclear Information System (INIS)

In the present paper we estimate the effect of sodium in the in-service inspection of non-magnetic steam generators tubes using eddy current technique and eddy current probes based on a differential double bobbin coil configuration. Experimental measurements of defects signals in steam generator tubes of fast breeder reactor are compared with simulations results of a two-dimensional axisymmetric finite element code to validate a reliable electromagnetic model of the system (eddy current coils, steam generator tube, defect) when there is no sodium on the outer steam generator tube surface. The electromagnetic code is used to evaluate the sodium band and sodium layer signals when a defect is located under steam generator support plate. Using a multi-frequency algorithm, its parameters are determined in the 'no sodium condition' (there is no sodium on the outer steam generator tube ...

2007-04-22

394

A review of heat exchanger tube bundle vibrations in two-phase cross-flow  

International Nuclear Information System (INIS)

Flow-induced vibration is an important concern to the designers of heat exchangers subjected to high flows of gases or liquids. Two-phase cross-flow occurs in industrial heat exchangers, such as nuclear steam generators, condensers, and boilers, etc. Under certain flow regimes and fluid velocities, the fluid forces result in tube vibration and damage due to fretting and fatigue. Prediction of these forces requires an understanding of the flow regimes found in heat exchanger tube bundles. Excessive vibrations under normal operating conditions can lead to tube failure. Relatively little information exists on two-phase vibration. This is not surprising as single-phase flow induced vibration; a simpler topic is not yet fully understood. Vibration in two-phase is much more complex because it depends upon two-phase flow regime, i.e. characteristics of two-phase mixture and involves an important consideration, which is the void ...

2004-05-01

395

X-ray exposure in the teaching of science at junior and senior high schools  

Energy Technology Data Exchange (ETDEWEB)

A significant amount of X-rays were detected as a leakage from some of the Crooke`s tubes which were used in the teaching of science at junior and senior high schools in Japan. We measured the leaked dose of X-rays from the Crooke`s tubes with ionizing chambers, film badges and TLDs. The maximum leaked dose at 5cm distance from those tubes was estimated 143mSv/h. The effective energy of leaked X-rays was 19.3keV. The maximum dose of students exposed during the teaching of science were estimated 0.15mSv per experiment, which exceeded the value recommended in the ICRP publication 36. (author)

1995-10-01

396

Thermal energy storage system with stearic acid as phase change material  

Energy Technology Data Exchange (ETDEWEB)

A simple tube-in-tube heat exchanger system for thermal energy storage employing stearic acid as PCM has been investigated. The performance and heat transfer characteristics of such a system were studied. Phase transition temperature range and times were measured and the speed of the phase transition front was computed. The melting front was found to move in the radial direction inward as well as in the axial direction from the top toward the bottom of the phase change material PCM tube. The speed of the melting front is enhanced by a convection heat transfer mechanism in the melted PCM. The heat transfer rate and, consequently, phase transition time can be altered by changing the water inlet temperature to the heat exchanger. In addition, a faster phase transition is realized by placing the heat exchanger in a horizontal position rather than a vertical one. (Author)

1994-10-01

397

Summary of denting mechanism and kinetic studies with seawater  

International Nuclear Information System (INIS)

Studies at Commissariat a l'Energie Atomique (CEA) have been under way for three years in an attempt to find methods for preventing and stopping denting. Tests have been performed in 28 model boilers (Ajax with U tubes and Clarinette with straight tubes). In these boilers, with continous injection and blowdown, and heat flux is about 40 W X cm"-"2 (126900 Btu/ft"2 X h). The kinetics of denting has been studied with different levels of faulting. Some high-temperature electrochemical measurements established the mechanism of denting in the boiler tests. Denting kinetics can be rationalized in terms of three main parameters: faulting level, heat flux, and relative mechanical strength of the tube compared to the support plate.

398

Special eddy current probes for heat exchanger inspection  

International Nuclear Information System (INIS)

Until a decade ago, only the differential bobbin type eddy current probe was considered necessary for reliable heat exchanger tube inspection. The introduction of different tube materials, manufacturing processes and a variety of service induced failures has greatly increased the demands of eddy current testing. Optimized probe designs enhanced by improved instrumentation can help satisfy some of these demands. Some of the more difficult inspection problems are detection of circumferential cracks, fretting wear under non-ferromagnetic support plates and shallow internal defects. Reliable detection and sizing of such defects is often made more difficult by the fact they frequently occur in defect prone regions such as under tubesheets or support plates and in transition regions of finned tubes. Probe designs effective in overcoming these difficulties exist. This paper describes a number of such probes and their performance.

1986-11-17

399

Research of time-domain equivalent circuit method in solving dispersion of coupled-cavity traveling-wave tube  

International Nuclear Information System (INIS)

In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)

2008-09-01

400

Relative performance of supercritical binary geothermal power cycles with in-tube condensors in different orientations  

Energy Technology Data Exchange (ETDEWEB)

The Heat Cycle Research Program, which is conducted for the Department of Energy, has as its objective the development of the technology for effecting the improved utilization of moderate temperature geothermal resources. The current testing involves the investigation of the performance of binary power cycles utilizing mixtures of non-adjacent hydrocarbons as the working fluids, with supercritical vaporization and in-tube condensation. The utilization of these concepts will improve the net geofluid effectiveness (net plant output per unit mass of geofluid) about 20% over that of a conventional binary power plant. The major prerequisite for this improvement is the achievement of integral, countercurrent condensation. Results are presented for testing of the performance of the condenser at different tube inclinations. The performance in the vertical orientation is better than in either the horizontal or inclined orientations. 7 refs., 8 figs.

1989-01-01

401

Process for filling tubular plates for lead batteries. Verfahren zum Fuellen von Rohrplatten fuer Bleiakkumulatoren  

Energy Technology Data Exchange (ETDEWEB)

The following method is proposed as a supplement to main patent 2419107, which deals with the filling of tubular plates surrounding the lead cores: the flat materials which are used to produce the jacket tubes are prepared before forming into jacket tubes by a film producing aqueous carboxy-methyl cellulose solution closing the pores. The preparation can be done by coating the flat material with a soluble foil. After pressing the paste in, the tubular plates are dried and after cooling are dipped into sulphuric acid with a specific gravity of 1.24 g/cm/sup 3/. The carboxy-methyl cellulose is dissolved and the permeability of the tube walls for electrolyte is restored after only 15 minutes.

1981-06-19

402

Post-CHF heat transfer with water and refrigerants  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer experiments were performed in the post-CHF two-phase flow regime in a vertical tube. The tube inside diameter was 7.75 mm, and the boiling fluid was R-113. The experiments were performed at steady state by means of liquid heating of the test tube. Wall superheats were maintained below 70 C for heat exchanger/steam generator application. The mass flux range of the data was 379-816 kg m{sup -2} s{sup -1}. The use of R-113 significantly extended the property range of the existing low wall-superheat data base. Experimental data are presented in tabular as well as graphical form, and the results were used with low wall-superheat data from other fluids to add generality to a predictive heat transfer correlation. (orig.)

1996-06-01

403

Offshore drilling rig with enclosed work area  

Energy Technology Data Exchange (ETDEWEB)

In order to improve the working conditions for the operators of drilling rigs, the work area for handling of pipes and tubes is arranged on a main deck convered by a drill deck, which has openings closable by hatch cover panels. The derrick is enclosed in a cover, from which tunnels extend out over the drill deck and comprises lifting means for handling of pipes and tubes between the decks. The tunnels are connected to the cover of the derrick by raised enclosures permitting the swinging of pipes from a horizontal position in the tunnel to a vertical position in the derrick, and vice versa. There is a door, at least at one of the enclosures, permitting handling of especially long objects. Basically, the handling of pipes and tubes can be performed within areas fully protected from the weather.

1987-12-01

404

Mining User Comment Activity for Detecting Forum Spammers in YouTube  

CERN Document Server

Research shows that comment spamming (comments which are unsolicited, unrelated, abusive, hateful, commercial advertisements etc) in online discussion forums has become a common phenomenon in Web 2.0 applications and there is a strong need to counter or combat comment spamming. We present a method to automatically detect comment spammer in YouTube (largest and a popular video sharing website) forums. The proposed technique is based on mining comment activity log of a user and extracting patterns (such as time interval between subsequent comments, presence of exactly same comment across multiple unrelated videos) indicating spam behavior. We perform empirical analysis on data crawled from YouTube and demonstrate that the proposed method is effective for the task of comment spammer detection.

2011-01-01

405

Metallurgical Investigation of a Prematurely Failed Concentric Reducer Tube Used in a Hot-Rolling Mill  

British Library Electronic Table of Contents (United Kingdom)

A concentric reducer tube, which was a part of the top exit roughing hydraulic descaler in a hot strip mill failed prematurely under working pressure. A detailed metallurgical investigation comprising physical examination, optical microscopy, scanning electron microscopy, and electron probe microanalysis was carried out to find out the genesis of the failure. Physical examination revealed cracks located symmetrically around the circumference of the tube that ran along its full length, up to the weld beads at both ends. Optical microscopy of etched samples revealed a banded ferrite-pearlite structure and the existence of forging folds near the change-in-section(160? fillets). Cracks were found to initiate from these forging folds. No structural abnormalities were found in the weld beads and...

2007-01-01

406

Mechanical design of a PERMCAT reactor module  

International Nuclear Information System (INIS)

The PERMCAT is a membrane reactor proposed for processing fusion reactor plasma exhaust gas: tritium removal is obtained by isotopic swamping operating in counter-current mode. In this work, a membrane reactor using a permeator tube of length about 500 mm produced via diffusion welding of Pd-Ag thin foils is described. An appropriate mechanical design of the membrane module has been developed in order to avoid any significant compressive and bending stresses on the very long and thin wall permeator tube: two expanded bellows have been applied to the Pd-Ag tube, so that it has been pre-tensioned before operating. The elongation of the metal permeator under hydrogenation has been theoretically estimated and experimentally verified for properly designing the membrane reactor.

2007-02-01

407

Life extension of boilers using weld overlay protection  

Energy Technology Data Exchange (ETDEWEB)

The presentation describes the status of modern weld overlay technology for refurbishment, upgrading and life extension of boilers. The approaches to life extension of boilers include field overlay application, shop-fabricated panels for replacement of the worn, corroded waterwall and shop-fabricated overlay tubing for replacement of individual tubes in superheaters, generating banks and other areas. The characteristics of weld overlay products are briefly described. Also discussed are successful applications of various corrosion-resistant overlays for life extension of boiler tubes in waste-to-energy boilers, coal-fired boilers and chemical recovery boilers. Types of corrosion and selection of weld overlay alloys in these systems are also discussed. (orig.) 14 refs.

1998-12-31

408

Improvement of the PGV-1000 steam generator in-vessel components  

International Nuclear Information System (INIS)

Results of calculational investigations into circulation of water and steam-and-water mixture in the PGV-1000 steam generator heat exchanger bundle used at NPPs with the WWER-1000 reactors, are considered. Model of water circulation in horizontal steam generator with submerged heating surface under conditions of steam generation irregularity along the heat transfer tubes is made. On the basis of the obtained data the assumption is made about water essential overflows from the hot collector zone into the cold one. Overflow rate over the upper line of the heat transfer tubes may constitute 0.7 m/s. The conclusion is made about the necessity to set up the vertical barrier which divides hot and cold sections of heat transfer tubes and helps to avoid water transverse overflows.

1988-01-01

409

Impact of Tubing Length on Hemodynamics in a Simulated Neonatal Extracorporeal Life Support Circuit  

British Library Electronic Table of Contents (United Kingdom)

Abstract During extracorporeal life support (ECLS), a large portion of the hemodynamic energy is lost to various components of the circuit. Minimization of this loss in the circuit leads to better vital organ perfusion and decreases the risk of systemic inflammation. In this study, we evaluated the hemodynamic properties of differing lengths of tubing in a simulated neonatal ECLS circuit. The neonatal ECLS circuit used in this study included a Capiox Baby RX05 oxygenator (Terumo Corporation, Tokyo, Japan), a Rotaflow centrifugal pump (MAQUET Cardiopulmonary AG, Hirrlingen, Germany), and a heater and cooler unit. An 8 Fr Biomedicus arterial and a 10 Fr Biomedicus venous cannula were connected to the pseudopatient. One fourth inch tubing was used for both the arterial and the venous line. A ...

2010-01-01

410

Heat transfer augmentation in liquid metal reactor steam generators  

International Nuclear Information System (INIS)

The use of heat transfer augmentation devices has been proposed as a means for reducing the cost of steam generators for advanced LMR designs by approximately 25%. Experimental results are presented for two types of enhancers in the form of a twisted-tape and a core-tube insert in the steam tube of a 13.1-m-long, sodium-heated single-tube test section. Test parameters were prototypical of liquid metal reactor (LMR) steam generator design for a once-through high-pressure steam cycle. Heat transfer results are compared with the no-insert case on an overall and local basis. Although both augmentations increased overall performance, the mechanisms were different.

411

Fluidelastic instability of heat exchanger tube bundles; Review and design recommendations  

Energy Technology Data Exchange (ETDEWEB)

This paper reports that fluidelastic instability is the most important vibration excitation mechanism for heat exchanger tube bundles subjected to cross-flow. Most of the available data on this topic have been reviewed from the perspective of the designer. Uniform definitions of critical flow velocity for instability, damping, natural frequency and hydrodynamic mass were used. Nearly 300 data points were assembled. The authors found that only data from experiments where all tubes are free to vibrate are valid form a design point of view. In liquids, fluid damping is important and should be considered in the formulation of fluidelastic instability. From a practical design point of view, we conclude that fluidelastic instability may be expressed simply in term of dimensionless flow velocity and dimensionless mass-damping. There is no advantage in considering more sophisticated models at this time. Practical design guidelines are discussed.

1991-05-01

412

Evaluation of validity of the RELAP5/MOD3 flow regime map for horizontal tubes  

Energy Technology Data Exchange (ETDEWEB)

RELAP5/MOD3 code was developed for western type power water reactors with vertical steam generators. Thus, this code should be validated also for VVER design with horizontal steam generators. The validation work, which has been started in Lappeenranta University of Technology (LUT), has already shown some weaknesses of the code. For example the flow inside a steam generator horizontal tube in some accident cases is not correctly modelled by the code. It may be the result of erroneous prediction of the flow regime. The aim of the study is the attempt of verification of the flow regime map, which is used in the RELAP5/MOD3 computer code for two-phase flow in horizontal tubes. (18 refs.).

1996-12-31

413

Assessment of degradation processes in corrosion resistant steels in nuclear power engineering  

International Nuclear Information System (INIS)

The possible corrosion damage is discussed of the CrNi and CrNiMo types steels used as structural materials in WWER type nuclear power plants. It includes point and slot corrosion, corrosion cracking and corrosion fatigue as well as corrosion denting. Also discussed are test procedures that simulate operating conditions and are used for assessing the properties of metallurgical products (sheets and tubes) used in nuclear power engineering. Briefly described is a system for testing the said products in an aqueous medium while keeping the test parameters in a narrow range for a long time. Under the defined temperature, pressure and corrosion medium composition, the test specimens in this system can mechanically be loaded, both statically and dynamically or a temperature gradient can be produced at the tube-tube plate joint. (Z.M.). 1 fig., 1 tab., 10 refs.

1987-12-01

414

p-Nonyl-phenol: an estrogenic xenobiotic released from "modified" polystyrene.  

UK PubMed Central (United Kingdom)

Alkylphenols are widely used as plastic additives and surfactants. We report the identification of an alkylphenol, nonylphenol, as an estrogenic substance released from plastic centrifuge tubes. This...Full Text Available

1991-05-01

415

User's manual for the BNW-I optimization code for dry-cooled power plants. [MFCIRI Code  

Science.gov (United States)

This appendix provides a listing of the BNW-I optimization code, MFCIRI, for a metal finned tube dry-cooled heat rejection system for power plants. (LCL)

1977-01-01

416

The Mechanism and the Magnitude of Flow Boiling Augmentation in Tubes with Discrete Surface Roughness Elements (III).  

Science.gov (United States)

Related to other research on the effectiveness of flow boiling heat transfer augmentation using various types of turbulators this investigation comprises a definitive study of the effect of large discrete roughness elements on heat transfer over the entir...

1972-01-01

417

Study of nuclear materials by neutron scattering.  

Science.gov (United States)

Following studies on fiber and sheet texture of hexagonal crystal system in 1988, work has been extended to tube texture. Using the zircaloy-4 fuel cladding of Wolsung-type reactor as specimen, six pole figures for different crystallographic planes were m...

1990-01-01

418

Staphylococcal Enterotoxin B: Solid-Phase Radioimmunoassay  

UK PubMed Central (United Kingdom)

An immunoassay employing 125I-labeled enterotoxin B and polystyrene tubes coated with specific antibody was used for assaying purified and crude enterotoxin. Antibody was adsorbed to untreated...Full Text Available

1971-11-01

419

Solid-Phase Radioimmunoassay of Total and Influenza-Specific Immunoglobulin G  

UK PubMed Central (United Kingdom)

An antigen-antibody system of polystyrene tubes coated with immunoglobulin antibody was used for quantitating immunoglobulins. A similar radioimmunoassay method was adapted for a viral antigen-antibody...Full Text Available

1972-02-01

420

Site Error There's a problem with ... - NASA Technical Reports Server  

Science.gov (United States)

Mar 1, 2011 ... Bending moments recorded by sensors on the aluminum tube. ... the escape rocket motor, tests also were made with the escape tower and rocket .... Incoming photographic data will be electronically converted and processed ...

421

Problems and prospects of using structural materials for horizontal steam generators  

British Library Electronic Table of Contents (United Kingdom)

Prospects for using new structural materials instead of Grade 08Kh18N10T steel for making heat-transfer tubes for horizontal steam generators with the purpose to increase their service life from 30?40 to 60 or more years are considered.

2011-01-01

422

Prediction of refrigerant void fraction in horizontal tubes using probabilistic flow regime maps  

Energy Technology Data Exchange (ETDEWEB)

A state of the art review of two-phase void fraction models in smooth horizontal tubes is provided and a probabilistic two-phase flow regime map void fraction model is developed for refrigerants under condensation, adiabatic, and evaporation conditions in smooth, horizontal tubes. Time fraction information from a generalized probabilistic two-phase flow map is used to provide a physically based weighting of void fraction models for different flow regimes. The present model and void fraction models in the literature are compared to data from multiple sources including R11, R12, R134a, R22, R410A refrigerants, 4.26-9.58 mm diameter tubes, mass fluxes from 70 to 900 kg/m{sup 2} s, and a full quality range. The present model has a mean absolute deviation of 3.5% when compared to the collected database. (author)

2008-04-15

423

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

424

Modeling of soluble impurities distribution in the steam generator secondary water  

Energy Technology Data Exchange (ETDEWEB)

A model was developed to compute concentration of impurities in the WWER 440 steam generator (SG) secondary water along the tube bundle. Calculated values were verified by concentration values obtained from secondary water sample chemical analysis. (orig.). 2 refs.

1997-12-31

425

Modeling of a horizontal steam generator for the submerged nuclear power station concept  

Energy Technology Data Exchange (ETDEWEB)

A submerged nuclear power station has been proposed as an alternative power station with a relatively low environmental impact for use by both industrialized and developing countries. The station would be placed 10 m above the seabed at a depth of 30--100 m and a distance of 10--30 km from shore. The submerged nuclear power station would be manufactured and refueled in a central facility, thus gaining the economies of factoryfabrication and the flexibility of short-lead-time deployment. To minimize the size of the submerged hull, horizontal steam generators are proposed for the primary-to-secondary heat transfer, instead of the more traditional vertical steam generators. The horizontal steam generators for SNPS would be similar in design to the horizontal steam generators used in the N-Reactors except the tube orientation is horizontal (the tube`s inlet and outlet connection points on the tubesheet are at the same elevation). Previous RELAP5 ...

1993-05-01

426

Minimal distensibility of pulmonary capillaries in avian lungs compared with mammalian lungs  

UK PubMed Central (United Kingdom)

Previous physiological studies suggest that avian pulmonary capillaries behave like almost rigid tubes. We made morphometric measurements to determine the diameter of the capillaries in chicken...Full Text Available

2008-02-01

427

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

Energy Technology Data Exchange (ETDEWEB)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

1996-06-01

428

Methodological study of hemodynamic analysis of lung mass by contrast enhanced dynamic CT  

International Nuclear Information System (INIS)

We investigated a method of analyzing the hemodynamics of the lung mass by contrast enhanced dynamic computed tomography (dynamic CT) to determine the difference in vascular supply between the pulmonary artery and bronchial artery using an experimental model. Our experimental model consisted of two injectors connected to two tubes, representing the pulmonary artery and bronchial artery, which were further connected to a chamber representing the lung mass. Following infusion of contrast medium into each tube with some delay time, dynamic CT scans were performed to obtain time density curves of the two tubes and the chamber. Using the time-density curve of contrast passage, flow rates from the two tubes into the chamber were calculated by the curve fitting method. Calculated values correlated well with the adopted flow rates of fluid from the injectors (r=0.893) in the experiment. The results indicate our ...

429

Membrane nanotubes induced by aqueous phase separation and stabilized by spontaneous curvature  

UK PubMed Central (United Kingdom)

Tubular membrane structures are widespread in eukaryotic cells, but the mechanisms underlying their formation and stability are not well understood. Previous work has focused on tube extrusion from...Full Text Available

2011-03-22

430

Magnetic Fields in Massive Stars. II. The Buoyant Rise of Magnetic Flux Tubes Through the Radiative Interior  

CERN Document Server

We present results from an investigation of the dynamical behavior of buoyant magnetic flux rings in the radiative interior of a uniformly rotating early-type star. Our physical model describes a thin, axisymmetric, toroidal flux tube that is released from the outer boundary of the convective core, and is acted upon by buoyant, centrifugal, Coriolis, magnetic tension, and aerodynamic drag forces. We find that rings emitted in the equatorial plane can attain a stationary equilibrium state that is stable with respect to small displacements in radius, but is unstable when perturbed in the meridional direction. Rings emitted at other latitudes travel toward the surface along trajectories that largely parallel the rotation axis of the star. Over much of the ascent, the instantaneous rise speed is determined by the rate of heating by the absorption of radiation that diffuses into the tube from the external medium. Since the time scale for this ...

2003-01-01

431

Is Computerized Tomography Angiographic Surveillance Valuable for Prevention of Tracheoinnominate Artery Fistula, a Life-Threatening Complication after Tracheostomy?  

UK PubMed Central (United Kingdom)

ObjectiveThe aim of this study was to evaluate the utility of volume-rendered helical computerized tomography (CT) angiography focusing tracheostomy tube and innominate artery for...Full Text Available

2011-02-01

433

Fluid dynamics analysis of a Ranque-Hilsch vortex tube  

International Nuclear Information System (INIS)

Fluid dynamic analysis of a commercial, counter-flow Ranque-Hilsch Vortex Tube (Rh vt), Ex air 25 s cfm, has been performed in this work both experimentally and numerically; in particular Rh vt cooling power and temperature separation performances have been tested in both direct cooling employment (jet impingement) and indirect cooling employment (supplying cold plates). Experimental techniques, used in this work, revealed several difficulties to produce detailed information about velocity and temperature fields inside the tube and at both the exits. Hence numerical simulation of the flow inside the tube has been conducted using the commercial Cfd code Fluent 6.3.26. Compressible, turbulent, high swirling flow inside Rh vt has been simulated by using both Rans and Les approaches. In particular several turbulence closures have been used in the Rans simulations and results have been compared with Les ones. Large Eddy ...

2008-05-01

434

Evaluation of the Widal tube agglutination test for the diagnosis of typhoid fever among children admitted to a rural hdospital in Tanzania and a comparison with previous studies  

UK PubMed Central (United Kingdom)

BackgroundThe diagnosis of typhoid fever is confirmed by culture of Salmonella enterica serotype Typhi (S. typhi). However, a more rapid, simpler,...Full Text Available

435

Evaluation of new corrosion-resistant superheater tubing in high-efficiency waste-to-energy plants  

Energy Technology Data Exchange (ETDEWEB)

Field corrosion tests were conducted on eight single tube materials and two welded overlay materials in three typical Japanese waste incineration plants in an effort to develop new corrosion-resistant superheater tubes capable of functioning efficiently under temperature and pressure conditions of 500 C and 100 kgf/cm{sup 2}-g in high-efficiency waste-to-energy (WTE) plants. Austenitic alloys containing higher concentrations of chromium, nickel, and molybdenum [Cr + Ni + Mo] showed excellent corrosion-resistant properties, and the new alloys JHN24 and HR30M showed good corrosion resistance. Different corrosion rates found in each of the three plants were explained by differences in operating conditions, such as gas temperature, concentration of molten salts resulting from chlorine (Cl) content of deposits, heavy metal (zinc oxide [ZnO] + lead oxide [PbO]) content, etc. It was confirmed that the corrosion rate of materials positioned in the ...

1998-07-01

436

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

Energy Technology Data Exchange (ETDEWEB)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K{sup Iscc}, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most ...

2002-07-01

437

Effect of crevice environment PH on corrosion damage of horizontal steam generator tubes  

International Nuclear Information System (INIS)

In support of a project on lifetime calculation experiments were carried out to evaluate the resistance to environmentally assisted cracking (EAC) of steam generator tubes during operation. Estimations of the incubation period for crack initiation and the threshold K value, K"I"s"c"c, and the crack growth rate were made to predict evolution of damage in tube walls. The paper summarizes results of experiments of C ring specimen for the initiation testing and results of SENT (single edge notch tensile) specimen for the crack growth rate (CGR) testing. The specimens were exposed to concentrated environments at elevated temperatures simulating crevice environments in secondary side crevices in horizontal steam generators. The results show that the material of SG tubes is sensitive to transgranular environmentally assisted cracking in the three basic concentrated environments used, alkaline, neutral and acid. The most corrosive ...

2002-05-05

438

Eddy Current Inspection of Mildly Ferromagnetic Tubing.  

Science.gov (United States)

The past decade has seen the development of eddy current probes for inspection of the mildly ferro-magnetic alloy Monel 400. Due to the rapid advances in permanent magnet technology similar probes have been upgraded to magnetically saturate, and hence ins...

1984-01-01

439

Does My Child Have ADHD?  

Medline Plus

September 14, 2010 ADHD: Signs, Symptoms, Research NIMH researchers talk about the symptoms of ADHD as well as the latest research. Download this video. Watch on YouTube. Transcript Announcer: ADHD- Attention Deficit Hyperactivity Disorder- is one of the ...

440

Cross flow boiling in tube bundles  

Science.gov (United States)

This report contains two main subjects. One is the newly started investigation of cross flow boiling in tube bundles. The heat transfer information at this condition is of significant importance to horizontal steam generator design. The other one is the continuation of the research on boiling heat transfer in confined spaces. The research on cross flow boiling in tube bundles has been started. The Freon loop has been modified for higher flow and higher two phase quality. The test section design is finished and is under fabrication presently. The new instrumentation system is also established. The test matrix has been planned. The research on boiling in confined spaces proceeds steadily. This problem is of great importance to the boiling induced corrosion in the steam generator crevices between the tube and the support plate. In the report of 1981, detailed results were presented for analysis of single phase flow, two phase ...

1982-10-01

441

Coolant rate distribution in horizontal steam generator under natural circulation  

Energy Technology Data Exchange (ETDEWEB)

In the presentation the major factors determining the conditions of NCC (Natural Coolant Circulation) in the primary circuit and in particular conditions of coolant rate distribution on the horizontal tubes of PGV-1000 in NPP with VVER-1000 under NCC are considered. 5 refs.

1997-12-31

442

Conservative management of post traumatic thoraco diaphragmatico biliary fistula  

UK PubMed Central (United Kingdom)

We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.

2010-10-01

443

Comparative Inhibitory Effects of Antigen and Antibody in the Staphylococcal Enterotoxin Solid-Phase Radioimmunoassay System  

UK PubMed Central (United Kingdom)

A solid-phase radioimmunoassay employing 125I-labeled enterotoxins and polystyrene tubes coated with specific antibody has been developed for assaying the relative concentrations of antibodies...Full Text Available

1975-06-01

444

Chromium steel corrosion rates and mechanisms in aqueous nickel chloride at 300C  

International Nuclear Information System (INIS)

Rapid corrosion of PWR steam generator carbon steel support structures and consequential denting of steam generator tubes led to investigation of alternative support designs and materials. In recent designs of steam generators the carbon steel drilled hole tube support plate has been replaced by one of quatrefoil or trefoil shape to minimize the contact area. These plates are now made of more corrosion resistant chromium steel (approx. 12%Cr) to ensure that they are less vulnerable to attack in the event of adverse boiler water chemistry. This study was initiated to examine the corrosion behavior of a range of chromium steels in the acid chloride environments characteristic of tube/support plate crevices under adverse boiler water conditions. Objectives of the study were to: 1) determine the relative susceptibility of candidate tube support plate steels to acid chloride corrosion; 2) investigate the ...

1985-03-01

445

Changing the emphasis at Bruce A  

Energy Technology Data Exchange (ETDEWEB)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

1994-01-01

446

Changing the emphasis at Bruce A  

International Nuclear Information System (INIS)

Steam generator tube plugging rates have increased markedly at Bruce since the end of the 1980s. A new programme of refurbishment aims to keep the steam generators operating successfully until around 2015. (Author).

447

Boiler and HRSG tube failures. Lesson 2. Corrosion fatigue  

Energy Technology Data Exchange (ETDEWEB)

Fatigue damage occurs in general when a boiler tube is subject to repeat cyclic or fluctuating loading although the stress produced is below the material yield strength. The types of fatigue damage include, e.g., corrosion, thermal, mechanical, vibration, and creep fatigue. It is important to determine which form of fatigue is active, because measures to avoid repeat failures differ as the case arises. In this lesson, the focus is exclusively on corrosion fatigue. Corrosion fatigue occurs by the combined synergistic actions of cyclic loading and a corrosive environment. It is a discontinuous process with crack initiation and growth during transient periods. The excessive stresses may be caused during boiler operation by the restraint at tube attachments and by load changes (in particular during cold starts or forced cools) or during shutdown or restart of circulation boilers by thermal stratification of water along the tube ...

2009-10-15

448

Astronaut Jeff Williams Answers Your Questions  

National Aeronautics and Space Administration (NASA)

Expedition 22 Commander Jeff Williams, aboard the International Space Station 220 miles above Earth, responds to questions posted on YouTube concerning the station's orientation, life in space and the recent butterfly experiment.

2010-03-10

449

A post-labeling method for multiplexed and multicolored genotyping analysis of SSR, indel and SNP markers in single tube with bar-coded split tag (BStag)  

UK PubMed Central (United Kingdom)

BackgroundGenotyping analysis using capillary DNA sequencing with fluorescently labeled primer pairs obtained by polymerase chain reaction (PCR) is widely used, but is expensive....Full Text Available

450

A heating tube  

Energy Technology Data Exchange (ETDEWEB)

Hollow needles made of an electrically conducting material are attached by hinges in the openings of the perforated end of an insert in order to intensify heat and mass transfer. The free sections of the needles are placed outside the insert, and a wick is placed on the wall of the frame in the condensation area. The wick overlaps the inlet openings of the insert.

1980-09-23

451

A double antibody solid phase assay for DNA autoantibodies for clinical use.  

UK PubMed Central (United Kingdom)

DNA antoantibodies in serum will bind to antigen-coated polystyrene tubes and can be detected by radiolabelled anti-immunoglobulin. The method is quantitative, gives information on the antibody class...Full Text Available

1976-08-01

452

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

Energy Technology Data Exchange (ETDEWEB)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described ...

2007-07-01

453

A CANDU utility perspective on using world experience to manage Alloy 800 SG tube degradation  

International Nuclear Information System (INIS)

In response to European operating experience regarding Alloy 800 steam generator (SG) tube cracking, New Brunswick Power Nuclear (NBPN) recognized two important shortcomings in the industry SG technical support framework. First, information exchange networks between utilities with Alloy 800 SG tubing should be strengthened. Second and more importantly, there is a need for consistent industry guidance for Alloy 800 SG tubing degradation management, supported by clear technical bases. It is NBPN's perspective that this guidance can be improved immediately using the extensive amount of laboratory and field data that is available for Alloys 600, 690, and 800, and EPRI methodology developed to predict the performance of Alloy 690. NBPN has initiated the development of a performance-based inspection plan. This effort is based on demonstrated improvement factors for Alloy 800, defined by the EPRI approach, and described in this ...

2007-08-19

454

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

Energy Technology Data Exchange (ETDEWEB)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-15

455

Two-phase Flow Regime Maps in Horizontal and Vertical Tubes  

International Nuclear Information System (INIS)

A safety analysis code to design a pressurized water reactor and to obtain the licenses including entire proprietary rights is under development in domestic R and D project. The tasks of KAERI is to develop the constitutive relations including models for defining flow regimes and flow regime related models for inter-phase friction, wall frictions, wall heat transfer, and interphase heat and mass transfer in the two-phase three-field equations. In this paper, the process will be presented for choosing the best flow regime maps which occur in gas-liquid two-phase flow in horizontal and vertical tubes.

2007-10-01

456

Theoretical investigations of strength of a flexible tube made of NiTi; Festigkeitstheoretische Untersuchungen einer flexiblen Huelse aus NiTi  

Energy Technology Data Exchange (ETDEWEB)

A flexible, steerable tube (distal end) of an endoscope for the application in the laparoscopic surgery has been analyzed by means of the finite-element-method (FEM). The unusual mechanical and thermal features of the used shape memory alloy (SMA) of NiTi were taken in account. The analyses showed that the strains remain in the super-elastic region up to the maximum bending of 90 and no plastic deformations occur. The application of the shape optimization (CAO) made possible finding the optimal structure of the distal end and therefore powerful reducing the maximum strains in the critical regions. (orig.)

2000-04-01

457

Tank of sodium cooled fast reactor  

International Nuclear Information System (INIS)

Object: To provide a tank, which can safely and reliably accommodate high temperature sodium containing radioactive substance in case of occurrence of an accident in a sodium system and thus prevent spread of contamination. Structure: A sodium drain duct inserted into a tank from above the tank is provided at the position of its lower end with a buffer means for preventing direct flow-down of sodium to a bottom plate. A means for preventing the discharge of radioactive substance to the cover gas is provided above the lower end of the sodium drain tube so as to surround the sodium drain tube. (Kamimura, M.).

458

TVA's program to mitigate steam generator denting at Sequoyah and Watts Bar Nuclear Plants  

International Nuclear Information System (INIS)

TVA is currently engaged in an extensive program to mitigate steam generator tube denting at the Sequoyah Nuclear Plant, which is in commercial operation, and to prevent or minimize the onset of denting at the Watts Bar Nuclear Plant, which is under construction. This paper describes TVA's denting mitigation program, which is primarily feedwater chemistry and system operation improvement, and the effect the changes that have been implemented have had on the incidence as well as the progression rate of steam generator tube denting during the past 220 effective full power days of Sequoyah unit 1 operation.

1983-09-25

459

Process to eliminate the deposits formed in a steam generator of a pressurized water nuclear reactor  

International Nuclear Information System (INIS)

The present process allows to eliminate the corrosion products formed on the tube plates and in the interstices of plate-tube crosspieces of a PWR steam generator in order to avoid a corrosion phenomenon which may cause denting by presence of oxides. The process consists in applying on these oxides at about 50-100 degrees, an aqueous solution containing 6-8% of gluconic acid, 3-5% of citric acid, about 0.5% of a corrosion inhibitor and ammonia until a pH of 3-9.5 is obtained.

1984-04-05

460

Peristaltic flow of a couple stress fluid in an annulus: Application of an endoscope  

Science.gov (United States)

This paper discusses the influence of an endoscope on the peristaltic flow of a couple stress fluid in an annulus under a zero Reynolds number and long wavelength approximation. The inner tube is uniform, rigid, while the outer tube has a sinusoidal wave traveling down its wall. Analytical expressions for the axial velocity, stream function and axial pressure gradient are established. The flow is investigated in a wave frame of reference moving with the velocity of the wave. Numerical calculations are carried out for the pressure rise, frictional forces and trapping. The features of the flow characteristics are analyzed by plotting graphs and discussed in detail.

2008-04-01

461

Operating experience with condenser tubes made from copper alloys and new developments; Betriebserfahrungen mit Kondensatorrohren aus Kupferlegierungen und aktuelle Entwicklungen  

Energy Technology Data Exchange (ETDEWEB)

Copper alloys are a suitable tubing material for turbine condensers and heat exchangers. Due to problems with corrosions copper alloys increasingly are displaced by high-grade steel and titanium. Blockages and surface formation in the pipes, disturbance of the oxide coating formation, erosion and quality faults with the production are the causes for the corrosion. In the contribution under consideration counter measures are designated for the solution of the problems with corrosions. The application limits for different copper alloys are designated. Recommendations for the optimized operation are given.

2008-07-01

462

Microwave heating type evaporator  

Energy Technology Data Exchange (ETDEWEB)

Purpose: To prevent evaporization stills against corrosion due to radioactive liquid wastes. Constitution: Microwaves are supplied from a microwave generator by way of a wave guide tube and through a microwave permeation window to the inside of an evaporatization still. A matching device is attached to the wave guide tube for transmitting the microwaves in order to match the impedance. When the microwaves are supplied to the inside of the evaporization still, radioactive liquid wastes supplied from a liquid feed port by way of a spray tower to the inside of the evaporization still is heated and evaporated by the induction heating of the microwaves. (Seki, T.).

1987-01-22

463

Laboratory robotics projects in the Analytical Development Division at the Savannah River Laboratory  

International Nuclear Information System (INIS)

To encourage the application of robotics technology for routine radiobench applications, a laboratory dedicated to the research and development of contained robotic systems is being constructed. The facility will have several robots located in laminar flow hoods, and the hoods are being designed to allow the possibility for multiple robots to work together. This paper presents both the design features of the hoods and the general layout of the laboratory, and also discusses an application of a robotic system for the routine nuclear counting of gamma tube samples. The gamma tube system is presently operating in one of the routine analysis laboratories. 5 figs.

464

Integrity assessment of pressure tubes for Wolsung unit 2  

Energy Technology Data Exchange (ETDEWEB)

To improve operational safety of the fuel channel for Wolsung units the recommended primary heat transport system (PHTS) operating guidelines were developed, which provides a safe operation window in terms of pressure and temperature to maintain fuel channel integrity, which is similar to pressure-temperature curves used for primary pressure boundary integrity in PWRs and deterministic Leak-Before Break (LBB) analyses were conducted using recent understanding of delayed hydride cracking (DHC) mechanism. In addition, a comparative assessment of LBB analysis was made using the procedures of Fitness For Service Guidelines(FFSG) for pressure tubes rev. 0 and rev. 1.

1997-10-01

465

Implementation and management of Daya Bay Nuclear Power Plant in-core flux thimble tube in-service inspection  

International Nuclear Information System (INIS)

This article discusses the Daya Bay nuclear power plant in-core flux thimble tube in-service inspection method and strategy. High light of the multiple frequency eddy current technology adopted including frequency and probe choice, standard design, data acquisition process are involved. The wear defect-growing trends are studied on base of the history data, which contribute to the in-service inspection strategy decision. (authors)

2003-04-08

466

Hydrodynamics of swirling flow in a circular tube with sudden increase in cross-section and of the flow through a Borda mouthpiece  

Energy Technology Data Exchange (ETDEWEB)

By applying the mass, momentum, and angular momentum conservation laws and the maximum flow rate principle to swirling, effectively inviscid, incompressible flows in a circular tube with a sudden expansion and the direct-flow and reversed-flow Borda mouthpieces the dependence of the flow rate coefficient and mechanical energy losses on the radius ratio and nondimensional circulation is obtained. Several calculating approaches with potential and helical motion are introduced and investigated. In the case of helical motion, as the swirl decreases the axial core of the flow is found to close with a sudden change of the flow parameters.

1994-11-01

467

Development of electro-optical instrumentation for annular two-phase flow studies  

International Nuclear Information System (INIS)

The development of new electro-optical instrumentation for studying the annular dispersed two-phase flow regime is described. The system measures the thickness of the water film and droplet size and velocity distributions which would be encountered in such a flow regime. The water film thickness is measured by an improved capacitance method with a short time constant using newly developed sensor electrodes. The electrodes are made flush with the inner wall of a cylindrical tube and do not disturb the flow. In the test equipment, steady, laminar flow of water along the inner wall of the tube is controlled by appropriate valves and a porous jacket while droplets are introduced by means of a special spray nozzle.

1981-01-01

468

Development of ALLOY 800 for PWR/SG tubings resistant to IGSCC and general corrosion  

Energy Technology Data Exchange (ETDEWEB)

Resistance of ALLOY 800 as a PWR/SG tubings to IGC/IGSCC and Ni, Co release into high temperature water was evaluated as compared with ALLOYs 600 and 690. The study to improve the resistance to IGSCC and general corrosion was also made. From the results, ALLOY 800 was evaluated to be the most reliable among the high Ni alloys tested. In addition, the alloy would obtain further reliability in IGSCC and general corrosion resistance by the combined addition of Ti and Nb, and the prior oxidation treatments, respectively. (author).

1989-07-01

469

Detection of EDM defects under Monju support plate using experimental data from remote field eddy current probes and a multi-frequency algorithm  

International Nuclear Information System (INIS)

This paper describes detection of electro-discharged machine (EDM) defects in magnetic steam generator (SG) tubes of Monju fast breeder reactor (FBR). The EDM defects are located under support plate (SP), on the outer tube surface and they are detected by a remote field eddy current probe. Using the experimental measurements and a multi frequency algorithm, the defect signal can be extracted from the SP signal. The parameters of the multi-frequency algorithm were calculated by comparing SP measurements with two-dimensional finite element simulations (FEM). (author)

2006-07-01

470

Design of a tandem accelerator free electron laser  

International Nuclear Information System (INIS)

The motivation for using a tandem electrostatic accelerator as an electron accelerator for a free electron laser (FEL) is presented. The adaptation of the HVEC EN tandem at the Weizmann Institute for this purpose, electron beam optics and nonlinear FEL computation relevant for this FEL realization are described. In the tandem configuration the terminal is held at a positive potential. The electron beam is accelerated from ground potential to the terminal in one beam tube and then decelerated down the other beam tube. The FEL wiggler and cavity are at the terminal. Due to the beam energy recovery this scheme produces a high power beam at the terminal with a small investment in electrical power. (orig.).

471

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiences, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-07-01

472

Design criterion for tubed solar-heated cavity receivers  

Energy Technology Data Exchange (ETDEWEB)

Solar energy can be economically converted into electrical energy for small and medium power outputs. A typical solar power plant consists of a parabolic dish, cavity receiver and gas turbine. To obtain high gas turbine efficiencies, the working fluid used has to be heated to high temperatures. This necessitates the use of expensive high-quality materials for the tubes in the receiver. This expense must be kept to a minimum. The present paper demonstrates how this aim can be achieved by meeting the so-called Bammert Criterion.

1986-01-01

473

Corrosion performance of tube support materials  

International Nuclear Information System (INIS)

The problem of denting in steam generators leads to change in the conception of the tube support plates. A new material is now used for this component, a 13% Cr steel, which composition has been adjusted for weldability and mechanical resistance criteria. The geometry of trefoil support plate (TSP) has also been improved, using a broached TSP (quadrifoiled holes) instead of a drilled TSP. Tests have been performed on 13% Cr and C-steel broached TSP, and drilled TSP, to confirm the better resistance to denting of this new configuration.

1985-03-01

474

Comprehensive characterization of fuel, clad and wrapper materials and assemblies for fast reactors - towards design, development and performance  

International Nuclear Information System (INIS)

The paper provides a brief description of the fuel characterization for Fast Breeder Test Reactor (FBTR) and Prototype Fast Breeder Reactor (PFBR). The development and characterization of mechanical properties of Alloy D9 clad and wrapper tubes are discussed. The problems associated with fusion welding of Alloy D9 are outlined. Non-destructive characterization of cladding tubes by optimum encircling eddy current probes, on-line and off-line neural network methods is presented. Both the on-line and off-line neural network methods could readily detect and size defects specified by the designers

2004-01-01

475

BNES materials conference a status review of alloy 800  

International Nuclear Information System (INIS)

Existing applications of Alloy 800 are summarized, with particular reference to its use in various types of reactor. The need for a co-ordinated research and development programme is stressed, and the variables to be explored are outlined. The papers relating to the problem of corrosion and cracking in water and steam are considered. the strength and ductility of Alloy 800 is considered. Finally, sections of the summary deal with the use of Alloy 800 for (a) sodium cooled fast reactor boiler tubes; (b) the high temperature gas cooled reactor; and (c) PWR steam generator tubes. (U.K.).

476

Application of wavelet analysis to signal processing methods for eddy-current test; ueburetto kaiseki no kadenryushinshoho heno tekiyo  

Energy Technology Data Exchange (ETDEWEB)

This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube test pieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

1998-12-15

477

Application of the porous media model for the LWR process components  

Energy Technology Data Exchange (ETDEWEB)

Full text of publication follows: A porous media solution PORFLO has been developed for the 3-dimensional two-phase flow by describing the process facility in Cartesian or cylindrical coordinates. The local porosity fraction is applied for distinguishing the fluid filled volumes from the solid structures. The solid structure contribute the two-phase flow through the wall friction, flow area and heat transfer. Optionally the solid structure may contain primary liquid of steam generators, steam in the higher temperature and pressure to be condensed or electrical heating power. By using these optional boundary conditions three different process facilities have been analysed. The thermohydraulic solution based on 5-equation approach, where the conservation equations are solved for the liquid and gas (vapour) mass, mixture momentum (giving the velocity only for the mixture), liquid and gas energy, is described shortly. In addition to that the principles modelling optional boundary ...

2005-07-01

478

Application of neutron radiography to a diagnosis of refrigerator  

International Nuclear Information System (INIS)

A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).

1996-07-01

479

A truly commercial product  

International Nuclear Information System (INIS)

In one of the first uses of high Tc superconductors in an end-use product, Lake Shore Cryotronics and a Swiss lab have developed a liquid nitrogen level sensor using a high Tc thin film. The probe is manufactured using a seamless stainless steel tube with an yttrium-based zirconium oxide flame-sprayed on the tube. A plasma-sprayed superconductor compound is deposited on top of that. The probe is coated with a sealant that protects the superconducting film from the atmosphere. This manufacturing method has yielded an extremely durable product. Unaffected by ice formation and related mechanical problems, the superconducting level sensor can be kept in the dewar for long periods of time.

480

A review of the behaviour of alloy 800 in liquid sodium  

International Nuclear Information System (INIS)

Although there is service experience of Alloy 800 as tubing for superheaters in conventional and nuclear (HTR) power stations and in PWR heat exchangers, there is no corresponding service experience in sodium-cooled fast reactor steam generators. However, some limited experimental studies have been made of corrosion behaviour, and of possible structure modifications and effects on mechanical properties which occur during exposure of this material to a high temperature sodium environment, and these are summarised in the paper. It is concluded that further work needs to be done before Alloy 800 can be confidently endorsed for use as tubing in fast reactor steam generators. (author).

481

A mathematical model for a thermally coupled humidification?dehumidification desalination process  

British Library Electronic Table of Contents (United Kingdom)

The humidification?dehumidification process is an interesting technique that has been adapted for water desalination. Previous works experimentally investigated desalination processes in the shell and tube columns, where the humidification and dehumidification were thermally coupled and simultaneously performed at the tube and shell sides, respectively. In this work, a comprehensive steady-state mathematical model was developed for such a humidification?dehumidification desalination process by taking into account the heat and mass balances on both sides of the desalting column, the mass transfer rate at the humidification side, and the heat transfer rate between the dehumidification side and humidification side. Meanwhile, the mass transfer coefficient at the humidification side and the to...

2006-01-01

482

Visual inspection technology of the narrow and small confined area for monitoring feederpipe support of pressure tube in calandria reactor  

Energy Technology Data Exchange (ETDEWEB)

There are 760 feederpipes, which they are connected to inlet/outlet of the 380 pressure tube channels on the front of the calandria, in CANDU-type Reactor of Wolsung Nuclear Power Plant. As an ISI(In-Service Inspection) and PSI (Post-Service Inspection) requirements, maintenance activities of measuring the thickness of curvilinear part of feederpipe and inspecting the feederpipe support area within calandria are needed to ensure continued reliable operation of nuclear power plant. And ultrasonic probe is used to measure the thickness of curvilinear part of feederpipe, however workers are exposed to radioactivity irradiation during the measurement period. But, it is exposed to radioactivity irradiation during the measurement period. But, it is impossible to inspect feederpipe support area thoroughly because of narrow and confined accessibility, that is , an inspection space between the pressure tube channels is less than 100 mm and pipes in ...

1999-12-01

483

Studies on the permeation of hydrogen through steam generator tubes at high temperatures using an electrochemical method  

Energy Technology Data Exchange (ETDEWEB)

The permeation of hydrogen through steam generator tubes at high temperatures ({approx} 300 degrees C) has been studied using an electrochemical technique. With this technique, hydrogen is generated on one side of the tube and monitored on the other side. The time for the hydrogen to reach the other side is used to determine the diffusion coefficient of hydrogen in the tube. Boundary conditions at the entry and exit sides have been investigated separately. Preliminary studies were performed on Stainless Steel 316 and Nickel Alloy 800 to better understand the influence of the solution chemistry on the electrochemical evolution of hydrogen. The surface phenomena effect and the trapping effect are discussed to account for differences observed in the permeation response. The hydrogen permeation through oxides at the exit side has been studied. Two nickel alloys (Alloy 800 and Alloy 600), materials widely used for steam ...

1998-07-01

484

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330{sup o}C in very high cycle fatigue regime  

Energy Technology Data Exchange (ETDEWEB)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10{sup 10}cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10{sup 7} cycles) and strain controlled fatigue at temperatures up to 330{sup o}C have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288{sup o}C than at room temperature (RT). At the stress near the ...

2007-07-01

485

Fatigue behavior of Alloy 690 and Alloy 800 SG tubing at temperatures up to 330"oC in very high cycle fatigue regime  

International Nuclear Information System (INIS)

During the service in nuclear power plants, steam generator (SG) tubing will suffer from a vibration with a frequency from 30-40 Hz. This means that SG tubing will undergo a very high cycle fatigue process during the design life time (25 years=about 3x10"1"0cycles). The material degradation and the very high cycle fatigue life of SG tubing materials due to the vibration are therefore of concern. In this investigation, the fatigue properties of Alloy 690 and Alloy 800 SG tubing in the very high cycle fatigue regime (higher than 10"7 cycles) and strain controlled fatigue at temperatures up to 330"oC have been investigated. The fatigue properties of SG tubing of Alloy 690 are comparable to that of wrought material. The strain controlled fatigue properties of Alloy 690 and Alloy 800 are slightly better at 288"oC than at room temperature (RT). At the stress near the fatigue endurance, ...

2007-08-19

486

Effect of lead and silicon on localized corrosion of Alloy 800 in steam generator crevice environments  

Energy Technology Data Exchange (ETDEWEB)

The Alloy 800 tubes used in CANDU 6 steam generators have not experienced significant corrosion damage to date, which may be attributed to successful water chemistry control strategies. However, it is known that Alloy 800, like other steam generator (SG) tubing materials, is not immune to corrosion, especially pitting, under some plausible but off-specification operating scenarios. Electrochemical measurements provide information on corrosion susceptibility and rate, which are known to be a function of water chemistry. Using laboratory data in combination with chemistry monitoring and diagnostic software it is possible to assess the impact of plant operating conditions on SG tube corrosion for plant life management (PLIM). In this context, this paper discusses the results of electrochemical measurements made to elucidate the corrosion behaviour of Alloy 800 SG tubes under conditions simulating those ...

2001-09-01

487

EDF approach on OD corrosion of SG tubes  

Energy Technology Data Exchange (ETDEWEB)

The secondary side corrosion of steam generator tubes is the main degradation of components in operating power plants, strongly impacted by chemistry. This is why EDF has largely studied the chemical parameters in its 56 PWRs which might influence corrosion development. The results of 168 hideout returns of chemical species performed on the French plants allowed to draw conclusions on where chemical species are likely to concentrate in steam generators and on the influence of several contaminants on corrosion processes: sodium, chloride, phosphate, organic compounds, etc... Based on laboratory studies and plants feedback, new chemistry specifications were established and are now applied to EDF units to minimize corrosion and operating costs and to provide a good availability while maintaining an excellent safety. Boric acid is added in the secondary water of the 10 oldest units with Inconel 600 MA tubing, highly sensitive to intergranular ...

1998-12-31

488

Development of a numerical methodology to simulate the roller expansion forming process  

International Nuclear Information System (INIS)

A distinguishing design feature of CANDU nuclear reactors is the use of horizontal fuel channels housed in a horizontal vessel called a calandria, which is made of stainless steel 304L. Each channel consists of a Zr-2.5%Nb alloy pressure tube and an externally concentric Zr-2 calandria tube. The calandria tubes are joined to the end plates (tubesheets) of the calandria vessel by joints formed by roller expansion. The bores in the tubesheets are grooved. Roller expanded joints provide a cost effective means of joining dissimilar materials, require minimal space and no maintenance. The quality of these roller expanded joints is important from a sealing, strength and stress corrosion point of view. The roller expansion process consists of expanding the calandria tubes to deform them plastically against the bores and into the grooves of the tubesheets. Therefore, understanding the effect of the number, ...

2006-04-03

489

Delayed Hydride Cracking Mechanism in Zirconium Alloys and Technical Requirements for In-Service Evaluation of Zr-2.5Nb Tubes with Flaws  

International Nuclear Information System (INIS)

In association with periodic inspection of CANDU nuclear power plant components, Canadian Standards Association issued CSA N285.8 in 2005 as technical requirements for in-service evaluation of zirconium alloy pressure tubes in CANDU reactors. This first version, CSA N285.8 involves procedures for, firstly, the evaluation of pressure tube flaws, secondly, the evaluation of pressure tube to calandria tube contact and, thirdly, the assessment of a reactor core, and material properties and derived quantities. The evaluation of pressure tube flaws includes delayed hydride cracking evaluation the procedures of which are stipulated based on the existing delayed hydride cracking models. For example, the evaluation of flaw-tip hydride precipitation during reactor cooldown involves a procedure to calculate the equilibrium hydrogen equivalent concentration in solution at the flaw tip, Htipas ...

2007-05-10

490

Assessment of leak detection capability of Candu 6 annulus gas system using moisture injection tests  

Energy Technology Data Exchange (ETDEWEB)

The Candu 6 reactor assembly consists of an array of 380 pressure tubes, which are installed horizontally in a large cylindrical vessel, the Calandria, containing the low pressure heavy water moderator. The pressure tube is located inside calandria tube and the annulus between these tubes, which forms a closed loop with CO{sub 2} gas recirculating, is called the Annulus Gas System (AGS). It is designed to give an alarm to the operator even for a small pressure tube leak by a very sensitive dew point meter so that he can take a preventive action for the pressure tbe rupture incident. To judge whether the operator action time is enough or not in the design of Wolsung 2, 3, and 4, the Leak Before Break (LBB) assessment is required for the analysis of the pressure tube failure accident. In order to provide the required data for the LBB assessment of Wolsung Units 2, ...

1998-10-01

491

Isolated PWM DC-AC SICAM with an active capacitive voltage clamp[Pulse Density Modulated; Pulse Width Modulation  

Energy Technology Data Exchange (ETDEWEB)

In this report an isolated PWM DC-AC SICAM with an active capacitive voltage clamp is presented. AC-DC power supply is implemented in its simplest form: diode rectifier followed by a medium-size charge-storage capacitors and possibly with an EMC filter on the mains entrance. Isolation from the AC mains is achieved using a high frequency (HF) transformer, whose voltages are not audio-modulated. The latter simplifies the design and is expected to have many advantages over the approach where the transformer voltages are modulated in regards to the audio signal reference. Input stage is built as a DC-AC inverter (push-pull, half-bridge or a full-bridge) and operated with 50% duty cycle, with all the challenges to avoid transformer saturation and obtain symmetrical operation. On the secondary side the output section is implemented as rectifier+inverter AC-AC stage, i.e. a true bidirectional bridge, which operation is aimed ...

2004-03-15

492

Identifying surface structural changes in layered Li-excess nickel manganese oxides in high voltage lithium ion batteries: A joint experimental and theoretical study  

Energy Technology Data Exchange (ETDEWEB)

High voltage cathode materials Li-excess layered oxide compounds Li[Ni{sub x}Li{sub 1/3-2x/3}Mn{sub 2/3-x/3}]O{sub 2} (0 < x < 1/2) are investigated in a joint study combining both computational and experimental methods. The bulk and surface structures of pristine and cycled samples of Li[Ni{sub 1/5}Li{sub 1/5}Mn{sub 3/5}]O{sub 2} are characterized by synchrotron X-Ray diffraction together with aberration corrected Scanning Transmission Electron Microscopy (a-S/TEM). Electron Energy Loss Spectroscopy (EELS) is carried out to investigate the surface changes of the samples before/after electrochemical cycling. Combining first principles computational investigation with our experimental observations, a detailed lithium de-intercalation mechanism is proposed for this family of Li-excess layered oxides. The most striking characteristics in these high voltage high energy density cathode materials are (1) formation of tetrahedral lithium ...

2011-09-06

493

Field-effect research at the High Voltage Transmission Research Center  

Energy Technology Data Exchange (ETDEWEB)

This report presents information obtained during five different studies of field effects from high voltage transmission lines performed at EPRI's High Voltage Transmission Research Center. The first study is the development of a methodology for the evaluation of the expected frequency of occurrence of specific short-term effects of spark discharges and induced currents caused by overhead high voltage transmission lines. The methodology is divided into the analysis of the expected frequency of occurrence of situations in which induction effects may occur, and the analysis of the expected severity of the effect. The second study is of the electric field in the surface and on the immediate proximity of the strands of stranded conductors used for overhead high voltage lines. In particular, the cases of deformations of stranded conductors, caused by air expansion or by popped out strands, are ...

1991-02-01

494

Effect of elevated temperatures on the performance of an InP cell illuminated by a selective emitter  

Energy Technology Data Exchange (ETDEWEB)

The thermophotovoltaic (TPV) option was not selected for further deep space mission technology development in NASA for several reasons. Chief among them was the large radiator required to keep the photovoltaic cells at a sufficiently low operating temperature. This led to significant integration problems with the spacecraft and limited sensor view angles. It is clear that the issue of cell temperature is crucial for space applications because of radiator size and system impact. Many efforts have focused on matching cell band gap to appropriate emitters in the 1 to 2 {mu}m range, resulting in band gaps in the 0.5 to 0.8 eV range. However, low band gaps lead to low open circuit voltages ({approximately}0.25 to 0.45 V) caused by high intrinsic carrier concentrations (n{sub i}{sup 2}). Thus, in order to obtain high performance. Photovoltaic cell temperatures must be kept near room temperature. This leads to the inevitable consequence of very large radiators for space ...

1999-03-01

495

Ab initio study of lithium transition metal fluorophosphate cathodes for rechargeable batteries  

Energy Technology Data Exchange (ETDEWEB)

Density functional theory (DFT) calculations using plane-wave methods were performed for Li2TMPO4F, LiTMPO4F, and TMPO4F (TM=V, Mn, Fe, Co, Ni) to address their feasibility as high-voltage cathode materials for Li ion batteries. We computed their structures, average open circuit voltages, and thermal stabilities for step-wise lithiation/delithation (discharge/charge) reactions. The calculations suggest that associated unit cell volume changes are sufficiently small on average that they should not be a significant detriment to the mechanical stability of the cathode. In the nickel case, the calculated volume change deviates from the series by increasing during the first delithiation step. Furthermore, the volume increases for all these materials during the second delithiation step. It appears that the relative volume expansion in the series during delithiation is directly correlated to the degree of d-p rehybridization. Predicted average open ...

2011-08-18

496

Heat transfer augmentation of a circular pipe flow using nano-particle layers  

International Nuclear Information System (INIS)

For the advanced fusion reactor FFHR2 (Force Free Helical Reactor) that has been proposed by NIFS, molten salt Flibe (LiF:BeF2=64:36) breeder blanket system is selected because of Flibe's features such as chemical stability, low-pressure operation and low electric conductivity. The Flibe is however high Prandtl number fluid since it has high viscosity and low thermal conductivity. Therefore its heat transfer performance is low compared with liquid Li or Pb-Li. In addition to heat removal of 1MW/m2 on the first wall, electrolysis of molten salt due to MHD effect will take place under high flow rate condition. This indicates that heat transfer enhancement under low flow rate is essential for the Flibe blanket system. In our laboratory, heat transfer characteristics of molten salt HTS (KNO3:NaNO2:NaNO3=53:40:7), have been evaluated, which is used as a simulant fluid of Flibe from the points of view of Be's toxicity and similar Prandtl number. In this paper, we adopt nano-particle layer ...

2007-10-05

497

Alloy 800 SG tubing: current status and future challenges  

Energy Technology Data Exchange (ETDEWEB)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio ({>=}12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those ...

2007-07-01

498

Alloy 800 SG tubing: current status and future challenges  

International Nuclear Information System (INIS)

Alloy 800 has been used for steam generator (SG) tubing for more than 30 years, primarily in CANDU reactors and in reactors in Germany. The grade of Alloy 800 tubing used for this service has a controlled Ti/C ratio (#>=#12 for CANDU SGs), and this specification is sometimes termed Alloy 800 M or Alloy 800 NG . There have been very few corrosion-related flaws detected in this material in SG service, and, until recently, no incidences of cracking. There has been extensive R and D carried out on Alloy 800 tubing, both in Canada and elsewhere, under a variety of operating conditions, including shutdowns, which show that it has excellent resistance to corrosion-related degradation under specified and appropriate operating conditions. These R and D findings are reflected in the in-service experience. It has been shown from the R and D that Alloy 800 is susceptible to corrosion under acidic conditions, in particular those that ...

2007-08-19