WorldWideScience
1

Effect of external pressure on intramuscular blood flow at rest and after running  

Energy Technology Data Exchange (ETDEWEB)

Local blood flow in the thigh was measured with /sup 133/Xe clearance technique in eight male distance runners after compression with a foam rubber compress and a standard elastic bandage. Two degrees of compression were tested, and an initial experiment with rested subjects was followed by a similar experiment immediately after running. Maximum compression exerted a cutaneous pressure of 85 (+/- 8) mm Hg and caused an immediate cessation of intra-muscular blood flow in the compressed area. Moderate compression gave a cutaneous pressure of 40 (+/- 5) mm Hg and resulted in a reduction of blood flow by approximately 50%. During compression, there were no significant differences in the blood flow of rested subjects compared to subjects immediately after running. In acute soft tissue injuries, a maximum compression bandage should effectively reduce or eliminate the formation of an intra-muscular hematoma, ...

1987-10-01

2

Diabetic patients have abnormal cerebral autoregulation during cardiopulmonary bypass  

Energy Technology Data Exchange (ETDEWEB)

We tested the hypothesis that insulin-dependent diabetic patients with coronary artery bypass graft surgery experience altered coupling of cerebral blood flow and oxygen consumption. In a study of 23 patients (11 diabetics and 12 age-matched controls), cerebral blood flow was measured using 133Xe clearance during nonpulsatile, alpha-stat blood gas managed cardiopulmonary bypass at the conditions of hypothermia and normothermia. In diabetic patients, the cerebral blood flow at 26.6 +/- 2.42 degrees C was 25.3 +/- 14.34 ml/100 g/min and at 36.9 +/- 0.58 degrees C it was 27.3 +/- 7.40 ml/100 g/min (p = NS). The control patients increased cerebral blood flow from 20.7 +/- 6.78 ml/100 g/min at 28.4 +/- 2.81 degrees C to 37.6 +/- 8.81 ml/100 g/min at 36.5 +/- 0.45 degrees C (p less than or equal to 0.005). The oxygen consumption was calculated from jugular bulb effluent and increased from hypothermic values of 0.52 +/- 0.20 ...

1990-11-01

3

FFTF [Fast Flux Test Facility] Fission Gas Monitor Computer System  

International Nuclear Information System (INIS)

The Fast Flux Test Facility (FFTF) is a liquid-metal-cooled, fast neutron test reactor located on the Hanford Site. A dual computer system has been developed to monitor the reactor cover gas to detect and characterize any fuel or test pin fission gas releases. The system acquires gamma spectra data, identifies isotopes, calculates specific isotope and overall cover gas activity, presents control room alarms and displays, and records and prints data and analysis reports. The Fission Gas Monitor System (FGMS) integrates commercially available hardware and software, providing a reliable and easily maintained system. The design provides extensive automation of previous manual operations, reducing the need for operator training and minimizing the potential for operator error. The dual nature of the system allows either system A or B to be taken out of service for periodic tests or maintenance without interrupting the overall system performance. A control room color display tracks the ...

4

Regional myocardial perfusion in patients with atherosclerotic coronary artery disease, at rest and during angina pectoris induced by tachycardia  

International Nuclear Information System (INIS)

We studied regional myocardial perfusion by scintigraphic computer-assisted analysis of initial distribution, washout rates, and residual activity of "1"3"3Xe injected into the left coronary artery of four patients with normal arteriograms and 14 patients with coronary stenosis. At rest, residual activity in poststenotic regions was always greater than in control regions, but initial washout rates were not slower. During angina, following xenon injections, the amount of indicator distributed to the poststenotic regions was markedly reduced; the increase of the initial washout rates was smaller than in control regions relative to rest, and residual activity was higher. Initial washout rates did not differ as much as from those of normal myocardium because in severe ischemia too little indicator is deposited initially in these regions to produce a change of any magnitude. Indeed, when angina was induced immediately after the xenon injection, poststenotic washout rates became much slower ...

5

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

Energy Technology Data Exchange (ETDEWEB)

The measurements of the K X-ray intensity ratio I(K{alpha} {sub 2}/K{alpha} {sub 1}), I(K{beta} {sub 1}/K{alpha} {sub 1}) and I(K{beta}/K{alpha}) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a {sup 241}Am and 123.6 keV {gamma}-rays from a {sup 60}Co were used, and following the radioactive decay of {sup 51}Cr, {sup 55}Fe, {sup 67}Ga, {sup 99}Tc, {sup 111}In, {sup 131}I, {sup 133}Ba, {sup 133}Xe, {sup 137}Cs, {sup 201}Tl and {sup 226}Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-15

6

Measurement of relative K X-ray intensity ratio following radioactive decay and photoionization  

International Nuclear Information System (INIS)

The measurements of the K X-ray intensity ratio I(K#alpha# _2/K#alpha# _1), I(K#beta# _1/K#alpha# _1) and I(K#beta#/K#alpha#) for elements V, Mn, Zn, Tc, Ru, Cd, Xe, Ba, Cs, Hg and Rn were experimentally determined both by photon excitation, in which 59.5 keV #gamma#-rays from a "2"4"1Am and 123.6 keV #gamma#-rays from a "6"0Co were used, and following the radioactive decay of "5"1Cr, "5"5Fe, "6"7Ga, "9"9Tc, "1"1"1In, "1"3"1I, "1"3"3Ba, "1"3"3Xe, "1"3"7Cs, "2"0"1Tl and "2"2"6Ra. K X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the theoretical values. It was observed that present values agree with the previous theoretical and other experimental results.

2007-01-01

7

Cognitive performance correlates with cerebrovascular impairments in multi-infarct dementia  

International Nuclear Information System (INIS)

Cerebral blood flow (CBF) was measured by the "1"3"3Xe inhalation method in patients with multi-infarct dementia (MID, N = 26), Alzheimer's dementia (AD, N = 19), and among age-matched, neurologically normal, healthy volunteers (N = 26). Cognitive performance was assessed in all subjects using the Cognitive Capacity Screening Examination (CCSE). Cerebral vasomotor responses were calculated from differences in values of mean hemispheric gray matter blood flow (Delta CBF) measured during inhalation of 100% oxygen (hyperoxia) compared with CBF measured while breathing room air. Significant correlations were found between CCSE performance and vasomotor responsiveness in patients with MID (P less than .01), but not in patients with AD or in neurologically normal volunteers. Loss of vasomotor responsiveness is an indicator of cerebrovascular disease with rigidity and/or loss of reactivity of cerebral vessels, which impairs cerebrovascular responses to situational demands and predisposes to ...

8

Mechanisms of renal handling of lead  

International Nuclear Information System (INIS)

The relative roles of glomerular filtration, tubular reabsorption and tubular secretion in lead handling were evaluated using renal clearance technique, stop-flow analysis, and renal lead accumulation. In addition, the effect of altering acid-base status on renal handling of Pb was determined. Clearance of ultrafilterable lead was measured in anesthetized dogs during infusion of "2"0"3Pb with small doses of carrier Pb(0.5 to 50 #mu#g/kg/h). Filterable lead concentration was estimated by in vitro ultrafiltration of non-anticoagulated plasma. Fractional excretion of Pb was calculated using creatinine clearance to estimate glomerular filtration rate. Dogs in acute metabolic acidosis had the lowest fractional excretion of ultrafilterable Pb (< 0.1); those in alkalosis had high fractional Pb excretion (0.75 to 2.5) while normal dogs were intermediate (0.1 to .4). The fractional excretion of Pb during ...

9

Hemoglobin radiolabeling: in vitro and in vivo comparison of iodine labeling with iodogen and a new method for technetium labeling  

International Nuclear Information System (INIS)

The present investigation compares the suitability of two radiolabeling techniques for hemoglobin. "1"2"5I labeling of hemoglobin with Iodogen as iodinating agent caused major changes in the chromatographic behaviour and an accelerated plasma clearance of the labeled hemoglobin in rats. A recently developed two-step procedure for "9"9"mTc labeling gave better results. The label had only minimal influence on the chromatographic behaviour of hemoglobin. In vivo, no free label occurred in the circulation and no transfer of the label to other plasma proteins took place. The plasma clearance of "9"9"mTc-labeled hemoglobin in rats was slowed. However, this could be explained entirely by diminishing glomerular filtration, probably by inhibition of the dissociation of the hemoglobin molecule into dimers. The plasma clearance of hemoglobin modified by intramolecular cross-linking, which prevents dissociation of ...

10

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. ...

11

RangerMaster{trademark}: Real-time pattern recognition software for in-field analysis of radiation sources  

Energy Technology Data Exchange (ETDEWEB)

RangerMaster{trademark} is the embedded firmware for Quantrad Sensor`s integrated nuclear instrument package, the Ranger{trademark}. The Ranger{trademark}, which is both a gamma-ray and neutron detection system, was originally developed at Los Alamos National Laboratory for in situ surveys at the Plutonium Facility to confirm the presence of nuclear materials. The new RangerMaster{trademark} software expands the library of isotopes and simplifies the operation of the instrument by providing an easy mode suitable for untrained operators. The expanded library of the Ranger{trademark} now includes medical isotopes {sup 99}Tc, {sup 201}Tl, {sup 111}In, {sup 67}Ga, {sup 133}Xe, {sup 103}Pa, and {sup 131}I; industrial isotopes {sup 241}Am, {sup 57}Co, {sup 133}Ba, {sup 137}Cs, {sup 40}K, {sup 60}Co, {sup 232}Th, {sup 226}Ra, and {sup 207}Bi; and nuclear materials {sup 235}U, {sup 238}U, {sup 233}U, and {sup 239}Pu. To accomplish isotopic ...

1998-12-31

12

A study on the experimental verification for the pipe whip problem in a Nuclear Power Plant  

Energy Technology Data Exchange (ETDEWEB)

The purpose of this study is to investigate on the experimental verification analysis for the pipe whip problems and to obtain the quantitative evaluation technologies for the design technique of pipe whip restraints. These will contribute to the advance of nuclear regulatory technologies and enhance nuclear power plant safety. This study presents the experimental and transient analytical results of pipe whip tests using the 4', 6' diameter pipe and U-shaped restraints. In the tests, the effects of the overhang length, clearance, impact height on the pipe whip behavior of the pipe-restraints were investigated. The transient impact analysis of the pipe-restraint system was conducted by the finite element program ABAQUS. The applicability of the ABAQUS program to the pipe whip analysis is made clear through this analysis.

1993-12-15

13

Metabolic clearance of biologically active luteinizing hormone in man.  

UK PubMed Central (United Kingdom)

The plasma metabolic clearance of biologically active luteinizing hormone (bioactive LH) was studied using the rat interstitial cell testosterone (RICT) bioassay in six hypogonadotropic men after single...Full Text Available

1986-04-01

14

Impact of the 3,6,9-Trioxadecyloxy Group on Desazadesferrithiocin Analogue Iron Clearance and Organ Distribution  

UK PubMed Central (United Kingdom)

The impact of introducing a 3,6,9-trioxadecyloxyl group at various positions of the desazadesferrithiocin (DADFT) aromatic ring on iron clearance and organ distribution is described. Three DADFT...Full Text Available

2007-07-12

15

Effective In Vitro Clearance of Porphyromonas gingivalis by Fc? Receptor I (CD89) on Gingival Crevicular Neutrophils  

UK PubMed Central (United Kingdom)

Porphyromonas gingivalis has been implicated as a causative pathogen in periodontitis. Immunotherapeutic approaches have recently been suggested to aid in the clearance of P....Full Text Available

2001-05-01

16

Tracer studies with carrier-free lead-203  

International Nuclear Information System (INIS)

... blood cells in vitro in vivo injection intake lead 203 man renal clearance uptake

1972-07-30

17

Modeling of instabilities induced by cage clearances in ball bearings  

Energy Technology Data Exchange (ETDEWEB)

Generalized dynamic motion of balls and cage in a ball bearing are simulated by solving the differential equations of motion under prescribed operating conditions and bearing geometry. The general cage motion is parametrically evaluated as a function of clearances both in the ball pockets and at the guide lands. The design significance of the modeling approach is demonstrated by the prediction of critical clearances which trigger certain instabilities in the cage motion. In more practical terms, the correlation between cage clearances and instability defines a wear life for the bearing under the prescribed operating conditions. 10 refs.

1991-01-01

18

Effects of Pentobarbital Anesthesia on Survival, 'Escherichia ...  

Science.gov (United States)

... Title : Effects of Pentobarbital Anesthesia on Survival, 'Escherichia coli' Clearance, Glucose and Leukocyte Concentration in Dogs Subjected to ...

1978-08-28

19

Radioguided occult lesion localization versus wire-guided localization for non-palpable breast lesions: randomized controlled trial  

Scientific Electronic Library Online (English)

Abstract in english AIM: This prospective randomized clinical study was conducted to compare radioguided occult lesion localization (ROLL) with wire-guided localization to evaluate optimum localization techniques for non-palpable breast lesions. METHODS: A total of 108 patients who were undergoing an excisional biopsy for non-palpable breast lesions requiring pathologic diagnosis were randomly assigned to the ROLL group (n = 56) and wire-guided localization group (n = 52). In the study, pati (more) ents' characteristics, radiological abnormalities, radiological technique of localization, localization time, operation time, weight of the excised specimen, clearance margins, pathological diagnosis and perioperative complications were assessed. RESULTS: There were no differences between the two groups in terms of age, radiological abnormalities and localization technique (p = non-significant for all). ROLL ...

2011-01-01

20

Vascular filtration function in galactose-fed versus diabetic rats: The role of polyol pathway activity  

Energy Technology Data Exchange (ETDEWEB)

These studies were undertaken to assess the effects of increased galactose (v increased glucose) metabolism via the polyol pathway on vascular filtration function in the kidneys, eyes, nerves, and aorta. Quantitative radiolabeled tracer techniques were used to assess glomerular filtration rate (GFR) and regional tissue vascular clearance of plasma 131I-bovine serum albumin (BSA) in five groups of male Sprague-Dawley rats: nondiabetic controls, streptozotocin-diabetic rats, nondiabetic rats fed a 50% galactose diet, diabetic rats treated with sorbinil (an aldose reductase inhibitor), and galactose-fed rats treated with sorbinil. Sorbinil was added to the diet to provide a daily dose of approximately .2 mmol/kg body weight. After 2 months of diabetes or galactose ingestion, albumin clearance was increased twofold to fourfold in the eye (anterior uvea, choroid, and retina), sciatic nerve, aorta, and kidney; GFR was increased ...

1990-07-01

21

Translocation of particles to the pleural space and tracheobronchial lymph nodes following lung deposition  

Energy Technology Data Exchange (ETDEWEB)

The translocation of particles from the alveolar compartment to the pleural space and tracheobronchial lymph nodes was investigated in rats over a 30 day period following the intrapulmonary instillation of 4 x 10/sup 8/ polystyrene microspheres (1.9 ..mu..m dia.). In initial studies, approx. =10/sup 4/ particles were found in the pleural space compartment on Days 1, 14 and 30 after particle deposition, and most of these were cell-associated. Subsequent pleural space studies indicated, however, that the particles found in this compartment were, at least in part, due to the pleural lavage technique, and, unlike observations reported for some fibers, the translocation of the particles used in our study to the pleural space does not represent an important lung clearance pathway. In regard to particle clearance to the tracheobronchial lymph nodes, the accumulation of particles, most of which were extracellular, kinetically was ...

1985-01-01

22

Synthesis and radiolabelling of cysteine derivatives and pharmacological behaviour of their "9"9"mTc complexes  

International Nuclear Information System (INIS)

Full text: HMPAO, a butane monoxime derivative of propylene amine and ECD, ethyl cysteinate dimer, are currently being used as brain imaging agents. In an effort to develop new radiopharmaceuticals for imaging brain, we have synthesized amine and imine derivatives of ethyl cysteinate with butane monoxime, optimized labelling procedure with "9"9"mTc and studied the in vivo behaviour of their "9"9"mTc complexes. Imine derivative of ethyl cysteinate with butane monoxime was synthesized by refluxing equimolar amounts of butane monoxime and ethyl cystinate in dry benzene for 3 hours. The product was purified over silica with 10% ethyl acetate in chloroform as eluent. Amine derivative was prepared by reducing the imine derivative with sodium borohydride. The ligands were characterized by NMR spectroscopy and were found to be pure. The ligands were labelled with "9"9"mTc using stannous chloride as reducing agent. The complexes were characterized by paper chromatography, paper electrophoresis ...

1998-09-01

23

Radiation decontamination of dry food ingredients and processing aids  

International Nuclear Information System (INIS)

Radiation decontamination of dry ingredients, herbs and enzyme preparations is a technically feasible, economically viable and safe physical process. The procedure is direct, simple, requires no additives and is highly efficient. Its dose requirement is moderate. Radiation doses of 3-10 kGy (0.3-1 mrad) have proved sufficient to reduce the viable counts to a satisfactory level. Ionising radiations do not cause any significant rise in temperature. The flavour, texture or other important technological or sensory properties of most ingredients are not influenced at radiation doses necessary for satisfactory decontamination, and radiation obviates the chemical residue problem. The microflora surviving radiation decontamination of dry ingredients are more susceptible to subsequent antimicrobial treatments. Recontamination can be prevented as the product can be irradiated in its final packaging. Irradiation could be carried out in commercial containers and would result in considerable ...

24

CT findings after normal and unsuccessful functional endoscopic sinus surgery; Ruolod della tomografia computerizzata dopo chirurgia funzionale dei seni paranasali: rilievi normali e valutazioni degli insuccessi chirurgici  

Energy Technology Data Exchange (ETDEWEB)

The paper investigates the functional endoscopic sinus surgery with the Messer-linger's technique which treats benign or inflammatory diseases of paranasal sinuses resistant to medical therapy. The goal of this type of surgery is to open the obstructed sinus ostia and restore normal aeration and mucociliary clearance. The computerized tomography permits an accurate assessment of extension and results of functional endoscopic sinus surgery. [Italian] L'articolo discute l'uso della tecnica di Messerklinger nella chirurgia funzionale endoscopica dei seni paranasali per il trattamento delle malattie benigne e delle infiammazioni croniche. Essa disostruisce gli osti sinusali ripristinando la normale areazione e la pulizia mucociliare. La tomografia computerizzata consente di valutare l'estensione e i risultati del trattamento chirurgico funzionale, soprattutto nel caso di insuccesso terapeutico, rilevando malattia ...

1999-09-01

25

The root cause analysis of 9DVN002ZV fan failure in Daya Bay Nuclear Power Station  

International Nuclear Information System (INIS)

Extensive investigations and detailed analysis of the failure reason of 9DVN002ZV fan in Daya Bay Nuclear Power Station showed that the fan destroy was caused by the failure of non-drive end bear. The direct cause of this bearing' failure was its improper assembly caused by improper maintenance procedure, and the root cause was too small internal radial clearance after mounting. The factor affecting bearing internal radial clearance, the relationship between clearance and operating life time and fan failure process were discussed. (authors)

2005-09-01

26

Progress in development of controlled-clearance pressure balance in NMIJ  

International Nuclear Information System (INIS)

A new controlled-clearance pressure balance is under development with the aim of improving the hydraulic high-pressure standard up to 1 GPa. This pressure balance consists of three parts: (i) a pressure generation device up to 1 GPa, (ii) a weight-loading unit which can load/unload weights automatically and independently, (iii) a controlled-clearance piston-cylinder which is designed to allow the jacket pressure to be applied independently. Some adjustments were made for loading heavy weights on/off the piston safely, keeping them in balance, then generating the pressure stably. Stability of the generated pressure was checked for several piston-cylinders, and it was found that pressure fluctuation was less than a few parts per million. The jacket pressure coefficient of a 500 MPa controlled-clearance piston-cylinder was precisely evaluated as a function of both the system pressure and the jacket pressure.

2010-03-01

27

Interference Effects In A Photonic Crystal Cavity  

Science.gov (United States)

... AFRL-RV-PS-TP-2010-1001 9. SPONSORING / MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. ... (Clearance #377 ABW-2009-1628) 13. ...

2010-01-20

28

Exclusion, exemption and clearance in the mining and minerals industry - A review of the concepts from a South African perspective  

International Nuclear Information System (INIS)

The risks from mining and processing of ores is reviewed on a generic basis with particular reference to some of the confusions which can arise due to lack of consistency or common logic in the use of exclusion, exemption and clearance. The difference in exclusion and exemption are challenged by comparing doses received in high background radiation areas and the doses received from a mining practice. The common principle of risk to the human species is not applied consistently. The differences between IAEA recommendations and local regulatory conditions are compared, and the use of exemption levels as clearance levels is considered. A case study on management of mine tailings is presented with special focus on the use of clearance levels. In all areas of review the interpretation of regulation is subject to confusion resulting from inconsistencies which can distort free market economics. (author).

1997-05-06

29

Correlation between particle size, in vivo particle persistence, and lung injury.  

UK PubMed Central (United Kingdom)

Dosimetry parameters such as deposition, clearance, retention, and translocation and dissolution of inhaled particles in and to different lung compartments may be important for the persistence of particles...Full Text Available

1994-10-01

30

Carbohydrate-specified endocytosis: localization of ligand in the lysosomal compartment.  

UK PubMed Central (United Kingdom)

Carbohydrate-directed endocytosis is mediated by a receptor, the hepatic binding protein; it is responsible for the clearance of galactose-terminated glycoproteins from the circulation. This process...Full Text Available

1981-11-01

31

Effects of Pentobarbital Anesthesia on Survival, 'Escherichia coli' Clearance, Glucose and Leukocyte Concentration in Dogs Subjected to LD100. 'Escherichia coli'.  

Science.gov (United States)

This study was conducted to determine the effects of sodium pentobarbital anesthesia on survival of the dog, leukocyte response, E. coli clearance from the peripheral blood and blood glucose concentration in the leukocytotic endotoxin pre-injected canine ...

1978-01-01

32

Characteristics of boiling transition of tight lattice rod assembly  

International Nuclear Information System (INIS)

Critical power characteristics of tight lattice rod assembly was investigated using a simple-shaped experimental apparatus. An electrically heated rod with four spacers was placed in a circular tube, and boiling transition condition for a rod in an annular geometry was clarified varing annulus clearance. It was found that critical heat flux depends strongly on the clearance accoding as the gap becomes smaller. This results was compared with KfK correlation and the trends were well correlated. (author).

33

Scintiscanning with aerosols of "9"9Tc"m DTPA in the diagnostic strategy for pneumocystosis in aids patients  

International Nuclear Information System (INIS)

Pulmonary clearance of an aerosol of "9"9Tc"m DTPA was measured in 21 non-smoking AIDS and pneumocystosis patients. The results were compared with those of pulmonary scintiscanning with gallium. All the patients exhibited increased clearance, evidence of a considerable alteration in alveolar permeability. This increase was also observed in patients with normal chest X-rays and normal blood gases. The average clearance in these patients was 6 #+-# 2% min"-"1 as compared with a normal 1.1 #+-# 0.3% min"-"1. Conversely, only four out of eight patients with normal chest X-rays had abnormal gallium scans. Clearance returned to normal after recovery. Measurement of DTPA clearance appears to be a very sensitive indicator for the detection and follow-up of pneumocystosis. However, it is not very specific since it can be increased by tobacco poisoning, drug abuse and the presence of ...

1988-08-15

34

A stable neurotensin-based radiopharmaceutical for targeted imaging and therapy of neurotensin receptor-positive tumours  

International Nuclear Information System (INIS)

Neurotensin (NT) and its high affinity receptor (NTR1) are involved in several neoplastic processes. Thus, NT-based radiopharmaceuticals are potential tracers for targeted diagnosis and therapy of NTR-positive tumours. A new analogue based on NT(8-13), NT-XIX, with the three enzymatic cleavage sites stabilised, was synthesised and tested. The synthesis was performed by Boc strategy. Labelling with "9"9"mTc/"1"8"8Re was performed using the tricarbonyl technique. Metabolic stability was tested in vitro and in vivo. NT-XIX was further characterised in vitro in HT-29 cells and in vivo in nude mice with HT-29 xenografts. NT-XIX showed much longer half-lives than non-stabilised analogues. Binding to NTR1 was highly specific, although the affinity was lower than that of natural NT. Bound activity rapidly internalised into HT-29 cells and 50% remained trapped after 24 h. In the time-course biodistribution, the highest uptake was found in the tumour at all p.i. times. In ...

2009-01-01

35

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

Energy Technology Data Exchange (ETDEWEB)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 {mu}Sv/y, collective dose: 1 man{center_dot}Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 {mu}Sv per year and 0.166 man{center_dot}Sv per year about H-beam, and 158 {mu}Sv per year and 0.468 man{center_dot}Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

36

Safety assessment for clearance of radioactive metal wastes from nuclear facility  

International Nuclear Information System (INIS)

Safety assessments for clearance of H-beam and valves, main radioactive metal wastes in Kori nuclear power plants, were carried out to derivate a decontamination factor for satisfying the dose limits of clearance level (Maximum individual dose: 10 #mu#Sv/y, collective dose: 1 man#centre dot#Sv/y) in Korea. Maximum individual dose and collective dose were evaluated by internal dose conversion factor which based on the concept of effective dose in ICRP publication 60. The results of maximum individual dose and collective dose is 139 #mu#Sv per year and 0.166 man#centre dot#Sv per year about H-beam, and 158 #mu#Sv per year and 0.468 man#centre dot#Sv per year about valves respectively. Demand decontamination factor satisfied with, which is respectively more than 13.9 and 15.8 for satisfying clearance level.

2003-10-01

37

Pretreatment with the gram-positive bacterial cell wall molecule peptidoglycan improves bacterial clearance and decreases inflammation and mortality in mice challenged with Pseudomonas aeruginosa  

UK PubMed Central (United Kingdom)

The objective of this study was to determine if inflammatory tolerance and enhancement of innate immune function could be induced by the gram-positive cell wall component peptidoglycan (PGN)....Full Text Available

2008-10-01

38

Paracetamol reduces influenza-induced immunopathology in a mouse model of infection without compromising virus clearance or the generation of protective immunity  

UK PubMed Central (United Kingdom)

BackgroundSeasonal influenza A infection affects a significant cohort of the global population annually, resulting in considerable morbidity and mortality. Therapeutic strategies...Full Text Available

2011-05-01

39

Measuring the efficacy of anti-malarial drugs in vivo: quantitative PCR measurement of parasite clearance  

UK PubMed Central (United Kingdom)

BackgroundArtemisinin-based combination therapy, currently considered the therapy of choice for uncomplicated Plasmodium falciparum malaria in endemic countries,...Full Text Available

40

Induction of cytochrome P450 1A by cow milk-based formula: a comparative study between human milk and formula  

UK PubMed Central (United Kingdom)

During the treatment of neonatal apnea, formula-fed infants, compared to breastfed infants, show nearly three-fold increase in clearance of caffeine, a substrate...Full Text Available

2005-09-01

41

Dosing Recommendations for Continuous Venovenous Hemodiafiltration with AN69 Filter Membranes and Prismaflex Dialyzers  

UK PubMed Central (United Kingdom)

Background:Continuous renal replacement therapy is used to manage fluid and solute imbalances in critically ill patients but may affect the clearance of concurrently administered...Full Text Available

2009-11-01

42

Dissociation from albumin: a potentially rate-limiting step in the clearance of substances by the liver.  

UK PubMed Central (United Kingdom)

The hepatic uptake rate for certain albumin-bound drugs and metabolites correlates poorly with their equilibrium unbound concentration in the plasma, suggesting that binding equilibrium may not always...Full Text Available

1985-03-01

43

Conservative management of post traumatic thoraco diaphragmatico biliary fistula  

UK PubMed Central (United Kingdom)

We report herein a case of thoraco diaphragmatico biliary fistula in a 24-year-old male who was managed conservatively with antibiotics and tube thoracostomy and had complete radiological clearance.

2010-10-01

44

A neurodegenerative disease mutation that accelerates the clearance of apoptotic cells  

UK PubMed Central (United Kingdom)

Frontotemporal lobar degeneration is a progressive neurodegenerative syndrome that is the second most common cause of early-onset dementia. Mutations in the progranulin gene are a major cause of familial...Full Text Available

2011-03-15

45

A Master Conductor for Aggregate Clearance by Autophagy  

UK PubMed Central (United Kingdom)

Autophagic adapters including p62/SQSTM1 recognize polyubiquitinated autophagic targets such as toxic protein aggregates. Recently reporting in Molecular Cell, Filimonenko et al. provide evidence...Full Text Available

2010-05-18

46

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...

47

Velocity measurement of wake behind flat plate simulating BWR fuel spacer  

International Nuclear Information System (INIS)

Velocity field behind a flat plate, placed near the wall in a narrow channel as a simulant of a BWR fuel spacer, was measured by using a hot wire anemometer. It was found that not only the positions where the dead water region behind flat plate disappeared but also the locations where the velocity relaxation completed were almost independent of the width of the clearance, although the local average velocity and velocity fluctuation immediately downstream the flat plate were affected by the difference in the clearance. The transverse flow diversions in the channel cross section were evaluated from the shape of the average velocity profile. The decrease of local flow rate near the channel wall, which may causes the drift flow behind a flat plate, was encouraged as the drag of clearance increased. Attempts have been made to measure spanwise velocity in the narrow channel. A spanwise velocity that occurred due to flow diversion ...

2004-10-04

48

Radiostrontium clearance and bone formation in response to simulated internal screw fixation  

Energy Technology Data Exchange (ETDEWEB)

Changes in radiostrontium clearance (SrC) and bone formation (tetracycline labeling) were observed in the femurs of skeletally mature dogs following the various operative steps involved in bone screw fixation. Drilling, but not periosteal stripping, produced a small but statistically significant increase in SrC and endosteal bone formation in the distal third of the bone. Strontium clearance values equivalent to those produced by drilling alone were recorded after screw fixation at low or high torque (5 versus 20 inch pounds), as well as by the insertion of loosely fitting stainless steel implants. Bone formation (equals the percentage tetracycline-labeled trabecular bone surfaces) was increased by 30% when SrC values exceeded 3.5 ml/100 g bone/min, and the relationship was linear when SrC values ranged between 1.0 and 7.0 ml/100 g bone/min. The changes in SrC and bone formation one-week after bone screw application are primarily those ...

1987-06-01

49

Measurement of swirling flow in direct injection diesel engine (Part 2). Effect of piston cavity diameter and top clearance volume  

Energy Technology Data Exchange (ETDEWEB)

Swirling flow in a direct injection diesel engine was measured by a laser doppler velocimeter. Piston cavity diameter and top clearance volume were changed as factors affecting swirling flow to study the distribution of swirling flow speed. When using the same intake port and changing the opening ratio of piston cavity, the distribution of swirling flow speed was different by the cavity during intake process but these agree just after opening intake valve and then become again different by cavity. When increasing top clearance and decreasing compression ratio, the axial symmetry of flow during commpression process increases. When changing piston cavity, and also when changing intake port, the mean swirling ratio in inside and outside areas of combustion chamber has common tendency to increase and decrease respectively. The mean swirling flow in the combustion chamber may be capable to be predicted by devising a model which can describe this ...

1989-05-31

50

Absorption of lead from the bronchial region of the lung  

International Nuclear Information System (INIS)

Experiments have been reported previously in which lead-212 ions with lead carrier were instilled into the lungs of anaesthetised rabbits. Experiments were also reported in which bismuth-207 chloride was instilled into rabbit lung. To check that the chloride compound was cleared in the same way as ions instilled in isolation, lead-203 chloride has been instilled in three rabbits. Measurements of absorption of ionic lead have been repeated using the radon-222 daughter, lead-214. Rates of clearance from the lung of "2"0"3Pb as the chloride and "2"1"2Pb ions are compared, and retention functions are derived. Clearance from the lung of "2"1"4Pb ions is also shown, and retention functions are derived. (U.K.).

1978-03-01

51

The biodistribution and effect on hepatic parenchyma with intraarterial injected I-131 lipiodol into hepatic artery  

Energy Technology Data Exchange (ETDEWEB)

Iodized oil has been used as a contrast agent in lymphangiography. One of the commercially available compounds is Lipidol Ultra-fluid(LUF) which contains 38% iodine by weight. Nakakuma et al(1979) reported that LUF was selectively retained in the hypervascular hepatocellular carcinoma when injected directly into the ligated hepatic artery. Since that time, it has been widely utilized in the detection as well as the therapeutic attempts of hepatocellular carcinoma, where it has been mixed with chemotherapeutic agents or labeled with radioactive I-131. Like all significant advances, the mechanism of lipid retention within the hepatocellular carcinoma is not clearly understood, and also there is a lack of information about the biodistribution and kinetics of I-131 Lipiodol. The apparent safety of this technique require confirmation. The present study was aimed to assess the biodistribution and kinetics of intraarterially injected I-131 Lipiodol and the histologic ...

1989-08-15

52

Role of protracted exposure on the toxicology of inhaled "2"3"9PuO_2  

International Nuclear Information System (INIS)

Studies were initiated to examine in rats the effects of a protracted exposure to inhaled "2"3"9PuO_2. Graphs are presented to show effect of multiple exposures to "2"3"9PuO_2 on the deposition and clearance of "2"3"9Pu in the alveoli.

1977-05-01

53

Influence of the high-affinity growth hormone (GH)-binding protein on plasma profiles of free and bound GH and on the apparent half-life of GH. Modeling analysis and clinical applications.  

UK PubMed Central (United Kingdom)

The discovery of a specific high-affinity growth hormone (GH) binding protein (GH-BP) in plasma adds complexity to the dynamics of GH secretion and clearance. Intuitive predictions are that such a protein...Full Text Available

1993-02-01

54

Dynamic Deformation and Recovery Response of Red Blood Cells to a Cyclically Reversing Shear Flow: Effects of Frequency of Cyclically Reversing Shear Flow and Shear Stress Level  

UK PubMed Central (United Kingdom)

Dynamic deformation and recovery responses of red blood cells (RBCs) to a cyclically reversing shear flow generated in a 30-μm clearance, with the peak shear stress of 53, 108,...Full Text Available

2006-09-01

55

Device for laying cut peat in a drying formation  

Energy Technology Data Exchange (ETDEWEB)

A device for laying cut peat in drying formations is proposed consisting of separate compartments, reinforced on a common frame and with mechanisms for both vertical and horizontal mixing. In order to intensify the drying process, within the scope of laying cut peat, uniform clearances and spacing in formations is applied. The mixing compartments are joined in sections with capabilities for separate mixing in each unit. The compartments are joined together by hinges and can be turned 180 degrees on the hinges horizontal to the plane.

1980-06-17

56

100 Areas: (For Technical Progress Letter No. 97), May 7--13  

Science.gov (United States)

Physics information for the D and F piles is presented. Thermal conductivity, reactivity, and irradiation levels are included. Concerning the cooling systems: process water control, pressure drip studies, purging studies, corrosion, and gun barrel clearance of expanded graphite are discussed. (GHH)

1946-05-17

57

Quantitative assessment of cancer risk from exposure to diesel engine emissions  

Energy Technology Data Exchange (ETDEWEB)

Quantitative estimates of lung cancer risk from exposure to diesel engine emissions were developed using data from three chronic bioassays with Fischer 344 rats. Human target organ dose was estimated with the aid of a comprehensive dosimetry model. This model accounted for rat-human differences in deposition efficiency, normal particle clearance rates, transport of particles to lung-associated lymph nodes, respiration rates, and lung surface area, as well as high-dose inhibition of particle clearance. Recent evidence indicates that the inert carbon core of the diesel particulate matter is likely to be the primary source of carcinogenicity. The epithelial tissue lining the alveoli and lower airways is the primary target site for induction of lung tumors. Dose was therefore based upon the concentration of carbon particulate matter per unit lung surface area. Unit risk estimates were developed using either a time-to-tumor or a linearized ...

1993-02-01

58

Preparation and biodistribution of technetium-99m-labeled 1-(2-nitroimidazole-1-yl)-propanhydroxyiminoamide (N2IPA) as a tumor hypoxia marker  

Energy Technology Data Exchange (ETDEWEB)

A new hydroxyiminoamide ligand, 1-(2-nitroimidazole-1-yl)-propanhydroxyiminoamide (N2IPA) was synthesized. The biodistribution of {sup 99m}Tc-N2IPA in mice bearing S180 tumor demonstrated that the complex showed a selective accumulation in tumor and slow clearance from it. The tumor-to-tissue uptake ratios increased with time. At 4 hours after injection, the uptake ratios of tumor to muscle, blood, liver, heart, and lung reached 8.4, 1.5, 0.6, 2.9, and 2.3, respectively. Moreover, the tumor-to-liver uptake ratio steadily increased to 0.9 at 8 hours and 2.3 at 24 hours. The complex showed little uptake and quick clearance in blood, lung and other organs. Compared with other proposed hypoxia-imaging agents, this novel agent has advantages of higher tumor-to-muscle and tumor-to-blood uptake ratios and easier synthesis.

2004-02-01

59

Influence of compound grease on the performance of premium connections  

Energy Technology Data Exchange (ETDEWEB)

The authors investigated the harmful effect of compound grease on premium connections. The pressure buildup of compound grease trapped between threads was measured during and after makeup of the connection. The resulting hoop stress in the coupling and the reduction in the seal interference were also measured. Mathematical models were developed to calculate coupling stress and grease pressure. Results indicate that for the conventional API buttress-thread profile, the pressure of trapped compound grease remains permanently high after the connection is made up because of the small thread-clearance area. This high pressure results in a high coupling stress and a large reduction in seal interference diameter, thereby degrading the integrity of the connection. To solve this problem, the thread profile was redesigned with a thread-clearance area larger than that of conventional buttress thread. The connection with the new thread design showed a ...

1990-03-01

60

Effect of heat transfer augmentation by square rod array in impinging air jet system(heat transfer characteristic of potential core region)  

Energy Technology Data Exchange (ETDEWEB)

This research has been proceeded over the potential core region (H/B=2) of two-dimensional impinging air jet system, in which square rods(width of 6 mm) has been set up in front of heating surface in order to increase heat transfer. The objective of this research was to investigate the characteristics of heat transfer and air flow, in cases of the clearance from rods to heating surface (C = 1, 2, 4, 6 mm) and the pitch between each rods(P = 30, 40, 50 mm) changed. And this research compared the above with the experimentation without rods. As result, heat transfer performance was best under the condition of C = 1 mm, in case clearance changed, and there was no serious difference in the effect of heat transfer augmentation in the case of pitch of rods changed. (author) 11 refs. 12 figs.

1995-07-01

61

The onset conditions of enhancement of ice accumulation associated with heat-conducting plates located perpendicularly to heat-transfer surfaces; Part 1: Analysis for still water  

Energy Technology Data Exchange (ETDEWEB)

An analytical study of the ice-formation process associated with heat-conducting plates located perpendicularly to isothermally heated and cooled surfaces with some clearance is presented. It is proposed that the onset conditions, which describe whether the ice-volume fraction in a steady state is greater than or less than that without heat-conducting plates, are defined by the dimensionless distances between the heated/cooled walls and the heat-conducting plates. It is shown that the onset conditions are dependent on the pitch and the thickness of the heat-conducting plates and are less dependent on the thermal conductivity of the plates.

1994-07-01

62

Rapid clearance of iodine-131 MIBG from the heart and liver of patients with adrenergic dysfunction and pheochromocytoma  

Energy Technology Data Exchange (ETDEWEB)

Iodine-131 MIBG, a radiolabeled adrenergic neuron-blocking agent, decreased rapidly from the heart and liver of patients with adrenergic dysfunction and pheochromocytoma when compared with eight controls. However, there was no significant difference in the rate of (/sup 131/I)MIBG decrease in these organs between controls and patients in the intervals subsequent to 4 hr. These findings suggest that adrenergic neuronal uptake of (/sup 131/I)MIBG in these organs is smaller in the patients than in the controls. Measurements of time-activity relationships of radioiodinated MIBG may be useful for assessment of adrenergic function of these organs and thus of generalized disorders of adrenergic innervation.

1985-04-01

63

Performance of rubber heat-stable and radiation-stable seals in helium coolant lines  

International Nuclear Information System (INIS)

The integrity of helium circulation loop flanged joints has been attracting recent attention as a design problem, in the development of high-temperature facilities incorporating helium loops (e.g., the VRG-50 pilot nuclear facility). Elevated temperatures and pressures, and the radiation environment, impose additional requirements on sealant materials. This applies first and foremost to rubber seals, which have found widespread favor on account of its excellent elasticity, its ability to spontaneously conform to possible changes in the clearance in the seal assembly, and the low compressive stresses developed in the flange joint assembly.

64

Fiber optic feedthrough module and method of making same  

International Nuclear Information System (INIS)

A fiber optic feedthrough module which comprises a metal sleeve, a fiber optic element extending through the sleeve in spaced relation thereto, and a tandem series of centrally-apertured mating annular sealant bodies of thermoplastic material surrounding the fiber optic element and compressed between it and the sleeve. The module is made by first providing a loose subassembly of a plurality of individual but interfitting sealant bodies on the fiber optic element and then inserting this subassembly into a metal sleeve, following by swaging the whole assembly which eliminates clearances and provides sealed interfaces between the various contacting components. (author).

1983-05-25

65

Effect of tritium and helium-3 on the lifetime properties of Pd-Ag alloys in ITER tritium purification technology  

Energy Technology Data Exchange (ETDEWEB)

An experimental verification for long-term performance of a Pd-Ag permeation in ITER tritium fusion cleanup units (FCU) is needed. In addition, information is required on the influence of tritium and {sup 3}He decay on the physical and chemical properties of Pd-Ag alloys (V-1). The results of the investigations of alloys (V-1) (mechanical properties and microstructure) after long-term usage exposition in tritium are given in this report. The experimental conditions (temperature, pressure, clearance, {sup 3}He concentrations) and the previous conclusions on the V-1 alloy performance are presented. (orig.).

1996-10-01

66

Cocarcionogenesis of inhaled plutonium dioxide and beryllium oxide  

International Nuclear Information System (INIS)

Inhaled beryllium oxide results in impaired alveolar clearance of inhaled "2"3"9PuO_2 and induces an inflammatory reaction in the lung. However, only one of 184 rats exposed to beryllium developed a lung tumor; none of 128 unexposed rats developed a lung tumor. Fifty-six lung tumors were induced in 181 rats exposed to plutonium. A total of 37 lung tumors were found in 119 rats given combined exposures to beryllium and plutonium. Only in rats given the highest levels of both beryllium and plutonium was there an incidence of lung tumors greater than that seen with exposure to plutonium only.

1977-05-01

67

Prediction of response of blood lead to airborne and dietary lead from volunteer experiments with lead isotopes  

Energy Technology Data Exchange (ETDEWEB)

To predict the response of blood lead to airborne and dietary lead requires knowledge of the rate of uptake of lead into the body from lung and gut, its subsequent partitioning between compartments, the stay time in those compartments, and its redistribution or excretion. Tracer studies with volunteers have shown no differences in systemic distribution of inorganic lead between tissues whether it is taken by inhalation, ingestion or injection. Lead is rapidly transferred from plasma to red cells, and there is slower movement thence into liver and other soft tissues, to bone, and to excreta. Work at Harwell and elsewhere with /sup 203/Pb has shown that the initial rapid distribution leaves rather over half the assimilated lead attached to red cells. The result is remarkably consistent, and applies also to dogs and baboons. The renal clearance (Vu) (ratio of U to CB, or daily urinary output expressed as mass of blood having the same lead content), and also the ...

1985-04-22

68

Nod2 sensing of lysozyme-digested peptidoglycan promotes macrophage recruitment and clearance of S. pneumoniae colonization in mice.  

Science.gov (United States)

Streptococcus pneumoniae colonizes the mucosal surface of the human upper respiratory tract. A colonization event is gradually cleared through phagocytosis by monocytes/macrophages that are recruited to the airway lumen. Here, we sought to define the bacterial and host factors that promote monocyte/macrophage influx and S. pneumoniae clearance using intranasal bacterial challenge in mice. We found that the recruitment of monocytes/macrophages required their expression of the chemokine receptor CCR2 and correlated with expression of the CCR2 ligand CCL2. Production of CCL2 and monocyte/macrophage recruitment were deficient in mice lacking digestion of peptidoglycan by lysozyme (LysM) and cytosolic sensing of the products of digestion by Nod2. Ex vivo macrophages produced CCL2 following bacterial uptake, digestion by LysM, and sensing of peptidoglycan by Nod2. Sensing of digested peptidoglycan by Nod2 also required the pore-forming toxin pneumolysin. The generation ...

2011-08-15

69

Experimental studies of 4-inch pipe whip test under BWR LOCA conditions  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous circumferential guillotine break of primary coolant piping in nuclear power plants. The present paper describes the results of the pipe whip tests using test pipes of 4 inch diameter, under the BWR LOCA conditions, which were performed from 1979 to 1981. The tests were carried out at an initial pressure of about 6.8 MPa and an initial temperature of about 285/sup 0/C. The test pipe was 114.3 mm (4 in) in diameter, 8.6 mm in thickness and 4500 mm in length. The four pipe whip restraints used in the tests were the U-bar type of 8 mm in diameter and frabricated from Type 304 stainless steel. The experimental parameters were the clearance (30, 50 and 100 mm) and the overhang length (250, 400, 550 and 1000 mm). The main purpose of these tests is to investigate the effects of the clearance and the overhang length ...

1983-10-01

70

Comparison of /sup 99/Tcsup(m) complexes (NEP-DADT, ME-NEP-DADT and HMPAO) with /sup 123/IAMP for brain SPECT imaging in dogs  

Energy Technology Data Exchange (ETDEWEB)

In this study we have compared brain uptake and blood clearance of /sup 99/Tcsup(m)-N-ethylpiperi-dinediamino dithiol (/sup 99/Tcsup(m)-NEP DADT), its 4-methylated derivative (/sup 99/Tcsup(m)-Me-NEP-DADT) and /sup 99/Tcsup(m)-hexamethyl-propylene-amine-oxime (/sup 99/Tcsup(m)-HMPAO) with that of N-isopropyl(/sup 123/I)iodoamphetamine (/sup 123/IAMP) in two dogs. Single photon emission tomography (SPECT) was employed to measure brain accumulation and retention of the four radiopharmaceuticals. Cerebral uptake of the /sup 99/Tcsup(m) complexes was lower than that of /sup 123/IAMP. There was considerable extracerebral activity in the dog's head, especially in the olfactory and snout regions. Because of slow blood clearance, /sup 99/Tcsup(m)-HMPAO showed high uptake in these regions. Brain uptake of /sup 99/Tcsup(m)-HMPAO reached a plateau 5 to 10 min after intravenous injection and remained constant for the entire study period (1 h). ...

1987-08-01

72

Lithography Production Techniques for next Generations of Microelectronics  

CERN Document Server

Lithography Production Techniques for next Generations of Microelectronics

1992-01-01

73

Uptake of Pb by human skeleton and comparative metabolism of Pb and alkaline earth elements  

Energy Technology Data Exchange (ETDEWEB)

Measurements of the retention of /sup 47/Ca and of /sup 203/Pb were made following their administration by intravenous injection. Translocation to bone was measured by ..gamma.. counting the feet of subjects. Uptake by bone of /sup 203/Pb was comparatively slow and extrapolation to the whole skeleton indicated that 20% of the dose has been taken up within 20 days. By time, a similar fraction of the dose has been excreted in urine. Uptake by bone of /sup 47/Ca was about 1.5-2 times the amount excreted in urine. Both the uptake by bone, and its excretion in urine, were more rapid than that of /sup 203/Pb due to the greater attachment of the latter to red blood cells. However, the plasma clearance rate for Pb, like that of Sr, was greater than that of Ca.

1984-12-01

74

The NCRP wound model: development and application.  

Science.gov (United States)

The US National Council on Radiation Protection and Measurements, in collaboration with the International Commission on Radiological Protection, has been developing a biokinetic and dosimetric model for radionuclide-contaminated wounds. The finalised model is described briefly in this paper, together with the scientific basis and application. The multicompartment model uses first-order linear biokinetics to describe the retention and clearance of a radionuclide deposited in a wound site using seven default retention categories. Examples using plutonium nitrate in colloidal form and uranium in metal fragments show the behaviour of the less soluble forms of radionuclides in wounds, in which long-term retention is predicted. Using uranium as an example, the wound model is coupled to a uranium International Commission on Radiological Protection systemic model to predict urinary excretion patterns for different physicochemical forms of uranium. The latter application is ...

2007-08-31

75

Susceptibility to invasive bacterial infections in children with sickle cell disease  

British Library Electronic Table of Contents (United Kingdom)

Individuals with sickle cell disease (SCD) demonstrate an increased susceptibility to invasive bacterial infections (IBI). The most common organisms causing IBI are Streptococcus pneumoniae, nontyphi Salmonella species and Haemophilus influenzae type b (Hib). IBI are the most common causes of death in children below 5 years of age with SCD. Increased susceptibility to IBI is because of several factors including dysfunctional antibody production and opsonophagocytosis as well as defective splenic clearance. Early diagnosis of Hib and pneumococcal infections combined with antibiotic prophylaxis and immunization programs, could lead to significant improvements in mortality, especially in Africa. Pediatr Blood Cancer. 2010;55:401-406. Copyright 2010 Wiley-Liss, Inc.

2010-01-01

76

Study on a transportation and emplacement system of pre-assembled EBS module for HLW geological disposal  

International Nuclear Information System (INIS)

HLW disposal is one of the largest issue to utilize Nuclear power safely. In the past study, the concept, which buffer materials and Overpacked waste were transported into underground respectively, have shown. The concept of pre-assembled engineered barrier has advantage to simplify the logistics and emplacement procedure, however there are difficulties to support heavy weight of pre-assembled package by equipment under the condition of little clearance between tunnel and package. In this study, Combination of air bearing and two degree-of-freedom wheels were suggested for transportation, and air jack was suggested for unloading and emplacement system. Also, whole system for transportation and emplacement procedure was designed, and Scale model test was examined to evaluate the feasibility of these concept and functions. (author)

2009-11-01

77

Radiolabelled peanut lectin for the scintigraphy detection of cancer  

International Nuclear Information System (INIS)

To investigate the role of intravenously administered, radioiodinated peanut lectin ("1"3"1I-PNA) in the non-invasive detection of cancer, the pharmacokinetics and scintigraphic distribution of this novel tumor-seeking compound were studied in 8 patients with metastatic cancer of the colon, breast or lung. Scintigraphic localization of "1"3"1I-PNA was apparent at certain anatomical sites of known metastases in 2 patients and in a further 2 patients an adjacent malignant pleural effusion was visualized. The rapid clearance of radioactivity from the whole body and plasma with marked renal concentration and rapid urinary excretion of significant amounts of intact "1"3"1I-PNA (mol.wt. 107,000,pI 5.95) implied that this molecule was excreted selectively by the renal tubules. PNA or other lectins may find a role in the scintigraphic detection of selected types of cancer. (author).

1984-01-01

78

Parametric study of pipe whip behavior  

International Nuclear Information System (INIS)

A pipe whip test is one of the main subjects of the pipe rupture tests performed in Japan Atomic Energy Research Institute. In 1979, the pipe whip test of 4B, sch-80 pipe will be done under the BWR condition. As the preliminary analysis of this test, the pipe whip analysis of 4B, sch-80 pipe was implemented in order to make clear of the influences of the physical parameters on the pipe whip behavior. The pipe whip analysis was treated as nonlinear dynamic analysis of pipe-restraint system by using the general purpose finite element program ADINA. Overhang length, clearance between pipe and restraint, restraint length and cross section area of restraint were taken as physical parameters. It was clarified through this analysis how restraint displacement, restraint strain and distribution of energy between pipe and restraint were influenced by these parameters. (author).

79

Nonlinear response and stability of a spindle system supported by Ball bearings  

Energy Technology Data Exchange (ETDEWEB)

In this effort, the nonlinear responses and stability of a spindle system supported by ball bearings are presented. The dynamics of this system is described by a set of second order differential equations with a nonlinear piecewise smooth force. The Floquet theory is applied to investigate the stability of the periodic solution. Due to the loss of contact between the raceways and balls in the ball bearing, the bending of the frequency response curves switch to the left at the weak resonance region, which is similar to the frequency response curves of a system with a soft spring. With the decrease of the bearing clearance, the bending of the frequency response curves switch to the right, which is similar to the frequency response curves of a system with a hard spring. Increase of the frequency ratio, the bending of frequency response curves transforms from left to right. The route to chaos through a period doubling process is also observed in this spindle-bearing ...

2010-09-15

80

Nigeria's radioactive waste management policy and strategy document  

International Nuclear Information System (INIS)

Radioactive waste for legal and regulatory purposes may be defined as material that contains or is contaminated with radio-nuclides at concentrations or activities greater than clearance levels as established by the regulatory body, and for which no use is foreseen. Safe management of radioactive waste is essential to ensure protection of humans and environment. Radioactive waste management policy is a guideline for the safe management of radioactive waste. It expresses the commitment of the country towards the goal. Government should initiate investigation into best long-term option for management of spent nuclear fuels. Process of selecting option and eventual site should involve comprehensive public participation within set time frames (with deep geological disposal as preferred management option).

2009-07-14

81

NURE aerial gamma-ray and magnetic reconnaissance survey: southeastern area-Alaska Quadrangles. Volume I. Narrative report  

International Nuclear Information System (INIS)

A rotary-wing, reconnaissance high sensitivity radiometric and magnetic survey covering the Alaska portion of twenty-nine 1:250,000 UTMS quadrangles. A total of 21,409 line miles (34,455 line kilometers) of data were collected during the 1976 and 1977 flying seasons. This report covers only the Southeastern area comprised of the Skagway, Atlin, Mt. Fairweather, Juneau, Taku River, Sitka, Port Alexander, Sumdum, Petersburg, Bradfield Canal, Craig, Dixon Entrance, Ketchikan, and Prince Rupert NTMS 1:250,000 scale quadrangles which were flown during the 1976 and 1977 seasons. The radiometric data were normalized to 400 feet terrain clearance. The data are presented in the form of computer listings on microfiche and as stacked profile plots. A geologic interpretation of the radiometric and magnetic data is included in this volume.

82

Low frequency noise from MW wind turbines -- mechanisms of generation and its modeling  

Energy Technology Data Exchange (ETDEWEB)

During the present project the mechanisms of generation of low frequency noise (LFN) for upwind rotors has been investigated. A 3.6 MW turbine has been simulated with a noise prediction model from NASA in US. Running the model on this turbine a number of important turbine design parameters with influence on the LFN have been identified as well as other parameters not linked to the turbine design. Of important parameters can be mentioned 1) rotor rotational speed, 2) blade/tower clearance, 3) rotor configuration - upwind/downwind, 4) unsteadiness/turbulence in inflow. Further, the directivity characteristics of LFN has been computed as well as reduction in noise as function of distance from the turbine. In general low levels of LFN has been computed for the upwind rotor in standard configuration. (au)

2008-04-15

83

Evaluation of the hepatobiliary function with "9"9"mTc-EHIDA imaging during total parenteral nutrition  

International Nuclear Information System (INIS)

14 surgical patients with non-hepatobiliary diseases were studied with "9"9"mTc-EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. Duration of TPN ranged from 6-56 days, 10 of the 14 patients Beijing within 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominet findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatorcyte is also impaired. (2) The effect of TPN on liver function is reversible. It was concluded that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible.

84

Estimates of quantitative genetic parameters of immunological traits in the chicken.  

Science.gov (United States)

Three in vivo assays were used to measure the immunocompetence of chickens in two generations of a selection experiment. The obtained data were used to estimate the variance components for sire and dam for antibody production to Pasteurella multocida and Mycoplasma gallisepticum vaccines, for T-cell-mediated immunity evaluated by a phytohemagglutinin wing web assay, and for clearance of foreign particles from the circulatory system. Heritabilities of and genetic correlations among these immunological traits were calculated from the sire variance components. Heritability estimates of the immunological traits based on the sire component of variance ranged from .06 to .53, and genetic correlations among immunological traits were generally negative. PMID:1956847

1991-10-01

85

Eating the enemy in Crohn's disease  

British Library Electronic Table of Contents (United Kingdom)

Several old and new observations suggest the existence in Crohn's disease of a phagocytic disorder of macrophages related to impaired bactericidal activity of host cells or to the presence of invasive bacteria that have developed strategies to counteract macrophage killing. It was recently reported that disordered macrophage cytokine secretion underlies impaired acute inflammation and bacterial clearance in Crohn's disease. Secretion of proinflammatory cytokines by CD macrophages was impaired in response to E. coli or specific Toll-like receptor agonists. In addition, major advances in the etiology of Crohn's disease came from the existence of polymorphism in NOD2 and autophagy-related susceptibility genes (ATG16L1 and IRGM) in patients and from the identification of the presence of adhere...

2010-01-01

86

Autoradiographic study of regional distribution of gastric mucosal blood flow  

Energy Technology Data Exchange (ETDEWEB)

Iodo(/sup 14/C)antipyrine autoradiography was used to measure gastric mucosal blood flow in anesthetized rats and to study regional distribution. Blood flows of 61 +/- 8 ml.100 g-1.min-1 (means +/- SE) in corpus and 84 +/- 9 ml.100 g-1.min-1 in antral mucosa compared well with previously reported measurements by hydrogen clearance. Blood flow in the crests of corpus mucosal folds was significantly higher than in the valleys between folds, indicating that the greater susceptibility of the former areas to acute injury, documented in several studies, is not associated with a perfusion defect in the resting stomach. Corpus mucosal blood flow was also higher in the side walls of the stomach than in the greater curvature region, and in distal than in proximal locations. No systematic regional variations within antral mucosa were demonstrated.

1988-04-01

87

A study on the transient analysis of pipe and restraint due to impact loading  

Energy Technology Data Exchange (ETDEWEB)

In this study, experiments were performed for pipe whip phenomena simulation. The analytical method was developed by combining several kinds of elements in ABAQUS computer code, standard version 5.2 . The transient analytical and the experimental results of the pipe whip test using 6 inch diameter pipe and U-shaped restraints are presented. It is shown that the adequate clearance decreases the restraint strains. As the overhang length increased, the maximum strain of restraints decreased. When the impact force increased, the maximum restraint strain increased slightly. The analytical models simulate the experimental impact phenomena very precisely, with slight conservatism. It is verified that the analytical method developed is very suitable to pipe whip phenomena analysis in nuclear power plants. 6 refs., 10 figs., 1 tab.

1995-12-31

88

A network security case study; The Los Alamos National Laboratory integrated computer network  

Energy Technology Data Exchange (ETDEWEB)

This paper reports on a study to validate the Graphical Network Representation (GRPHREP) model which is being conducted on the Los Alamos National Laboratory Integrated Computer Network (ICN). The GRPHREP model is a software system application based on graph theory and object-oriented programming methodologies. It codified the Department of Energy (DOE) Order 5637.1, which is concerned with classified computer secret policy, restrictions, and requirements. The Los Alamos ICN is required to control access to and support large-scale scientific and administrative computing. Thus, large-scale scientific and administrative computing. Thus we felt that this large, complex, and dynamic network would provide a good test for the graphical and functional capabilities of the model. Furthermore, the ICN is composed of multiple partitions that reflect the sensitivity and classification of the computation (data) and designate the required clearance level for the user.

1991-01-01

89

A Hypothesis: Supplementation with Mushroom-Derived Active Compound Modulates Immunity and Increases Survival in Response to Influenza Virus (H1N1) Infection.  

Science.gov (United States)

We hypothesize that the mushroom-derived active compound may be a potential strategy for increasing survival in response to influenza virus (H1N1) infection through the stimulation of host innate immune response. The validity of the hypothesis can be tested by immune response to influenza infection as seen through survival percentage, virus clearance, weight loss, natural killer cell cytotoxicity, Tumor Necrosis Factor-? (TNF-?) and Interferon-gamma (IFN-?) levels, lytic efficiency in the spleens of mice and inducible nitric oxide synthase mRNA expressions in RAW 264.7 murine macrophage cells. The hypothesis may improve people's quality of life, reduce the medical cost of our healthcare system and eliminate people's fears of influenza outbreak. PMID:21660092

2011-03-20

90

Autocontrol technique of combined centrifuges  

International Nuclear Information System (INIS)

The design characteristic of the autocontrol technique of the combined centrifuge is introduced. Digital technique, vary structure control and interface technique, graphical display techniques, digital communication technique as well as electronic technique are applied in the course of research. Automation in the operation of large scale combined centrifuges and the course of combined test has been realized and it can coordinate with other systems of status monitoring, data collecting and centrifugal force-aerodynamic force matched load automatically

2009-12-01

91

Nondestructive Detection Techniques of Garter Springs from CANDU Reactors  

Energy Technology Data Exchange (ETDEWEB)

The design and material characteristics of garter spring were summarized and Nondestructive detection techniques of garter spring were also described. In particular, Eddy current testing of loose type garter spring was used in Wolsung unit 1 and was described in detail. The inspection technique of tight type garter spring has not been established and all candidated techniques were investigated in order to choose the possible detection technique. Candidated nondestructive techniques including RFEC, PEC, Magnetic technique using GMR sensor, AE, Guided Wave technique, and high frequency ultrasonic technique, are summarized for evaluating the detectability of tight garter spring.

2004-04-15

92

Survey of Cognitive Radio Techniques in Wireless Network  

CERN Document Server

In this report, I surveyed the cognitive radio technique in wireless networks. Researched several kinds of cognitive techniques about their advantages and disadvantages.

2011-01-01

93

Accelerator-based analytical techniques using ion and photon beams. Environmental and industrial applications  

International Nuclear Information System (INIS)

An overview of different Ion Beam Analysis (IBA) techniques is given. Examples of applications of the PIXE techniques to various types of samples are presented. (author)

1999-11-01

94

Synthesis and tissue distribution of substituted [{sup 125}I]iodophenylamine derivatives: Possible brain imaging agents  

Energy Technology Data Exchange (ETDEWEB)

The synthesis and brain uptake in mice of the radioidinated derivatives of N,N-dimethyl-N'-(idodimethoxyphenyl)-1,3-propanediamine, as well as the N-substituted derivatives of (iodoalkylphenyl)isopropyl, iodoalkylphenylethylamine and 3,4-(methylenedioxy)phenyl-amphetamine (MDA) are described. These compounds contain structural features of both IMP and HIPDM, the cerebral perfusion agents currently in clinical use. The radiolabeled analogs were obtained via the [{sup 125}I]I exchange method, or by [{sup 125}I]NaI treatment of the iodo-free precursor in the presence of an oxidant. Following intravenous injection in mice, all compounds showed important radioactivity concentrations in the lungs and kidneys. The N-substituted (iodoalkylphenyl)isopropyl and iodoalkylphenyl-ethylamine derivatives displayed a high initial brain uptake (>10%IDg{sup -1}) followed by a rapid clearance phase, resulting in lower brain-to-blood ratios as those reported for IMP ...

1997-02-01

95

Synthesis and tissue distribution of substituted ["1"2"5I]iodophenylamine derivatives: Possible brain imaging agents  

International Nuclear Information System (INIS)

The synthesis and brain uptake in mice of the radioidinated derivatives of N,N-dimethyl-N'-(idodimethoxyphenyl)-1,3-propanediamine, as well as the N-substituted derivatives of (iodoalkylphenyl)isopropyl, iodoalkylphenylethylamine and 3,4-(methylenedioxy)phenyl-amphetamine (MDA) are described. These compounds contain structural features of both IMP and HIPDM, the cerebral perfusion agents currently in clinical use. The radiolabeled analogs were obtained via the ["1"2"5I]I exchange method, or by ["1"2"5I]NaI treatment of the iodo-free precursor in the presence of an oxidant. Following intravenous injection in mice, all compounds showed important radioactivity concentrations in the lungs and kidneys. The N-substituted (iodoalkylphenyl)isopropyl and iodoalkylphenyl-ethylamine derivatives displayed a high initial brain uptake (>10%IDg"-"1) followed by a rapid clearance phase, resulting in lower brain-to-blood ratios as those reported for IMP and HIPDM. In contrast, ...

1997-02-01

96

Study on development of high performance evaporator for automotive air conditioner  

Energy Technology Data Exchange (ETDEWEB)

The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribboned channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermo viewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of 2,116 kg/cm{sup 2}, (2) mass fluxes of 40 to 70 kg/m{sup 2} s, (3) heat fluxes of 4,500 to 7,300 W/m{sup 2}, (4) inlet quality of 0.1 to 0.7. The results indicated that the ...

1995-02-01

97

Pulmonary clearance of soluble and insoluble forms of manganese  

Energy Technology Data Exchange (ETDEWEB)

Manganese is an essential metal of toxicologic concern primarily because of exposure via inhalation. Environmental forms of Mn exist mainly as insoluble oxides, yet much of the research information available relates to the soluble salts. In the present study, adult male Sprague-Dawley rats were intratracheally instilled with either soluble MnCl/sub 2/ or insoluble Mn/sub 3/O/sub 4/ labeled with /sup 54/Mn. Lungs and other major organs were sampled over a span of 3 mo after dosing with the respective chemicals, which were equivalent to 8 ..mu..Ci and 1 ..mu..mol of manganese in 0.2 ml of buffer. There was rapid clearance of Mn from the lungs in the case of both chemicals; the chloride cleared at an initial rate of nearly four times that of the oxide. Despite this early difference, the amount of /sup 54/Mn remaining in the lungs after 2 wk was similar for both compounds. The level of /sup 54/Mn in the liver, kidney, spleen, and testes peaked at the 3-d sampling point ...

1986-01-01

98

Intestinal circulation during inhalation anesthesia  

Energy Technology Data Exchange (ETDEWEB)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of /sub 86/Rb and 9-microns spheres labeled with /sup 141/Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. ...

1985-04-01

99

Intestinal circulation during inhalation anesthesia  

International Nuclear Information System (INIS)

This study was designed to evaluate the influence of inhalational agents on the intestinal circulation in an isolated loop preparation. Sixty dogs were studied, using three intestinal segments from each dog. Selected intestinal segments were pumped with aortic blood at a constant pressure of 100 mmHg. A mixture of _8_6Rb and 9-microns spheres labeled with "1"4"1Ce was injected into the arterial cannula supplying the intestinal loop, while mesenteric venous blood was collected for activity counting. A very strong and significant correlation was found between rubidium clearance and microsphere entrapment (r = 0.97, P less than 0.0001). Nitrous oxide anesthesia was accompanied by a higher vascular resistance (VR), lower flow (F), rubidium clearance (Cl-Rb), and microspheres entrapment (Cl-Sph) than pentobarbital anesthesia, indicating that the vascular bed in the intestinal segment was constricted and flow (total and nutritive) decreased. ...

100

I-131 labelled peanut lectin renal kinetics in cis-platin induced tubular toxicity in dogs  

International Nuclear Information System (INIS)

Quantitative I-131 labelled Peanut lectin (I-131-PNA) renal clearance was determined in dogs before and after a 5 day single cycle cis-platinum chemotherapy regimen (0.5mg/Kg/day). Results were statistically compared with E.R.P.F. (I-131-Hippuran), G.F.R. (Tc-99m-DTPA), and serum biochemistry and correlated with histopathology. I-131-PNA clearance was significantly reduced in all dogs 5 days after cessation of cis-platinum treatment (mean #DELTA#S% = 71.3%) and similar reductions in the gamma camera derived renogram peak were demonstrated (mean #DELTA#S% = 65.8%). E.R.P.F. was noted to drop by a minor degree (mean #DELTA#S% = 20.9%) post treatment. G.F.R. was diminished (mean #DELTA#S% = 46.6%) and serum creatinine elevated (mean #DELTA#S% = 42.7%) in all dogs compared to their pretreatment values. Histopathology demonstrated variable degrees of tubular toxicity ranging from mild to severe. The degree of change of the I-131-PNA values was ...

1985-06-02

101

Anatomic variations on PNS CT  

Energy Technology Data Exchange (ETDEWEB)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and ...

1994-09-15

102

Anatomic variations on PNS CT  

International Nuclear Information System (INIS)

To illustrate frequently encountered anatomic variations on PNS computed tomography(CT) and to assess their clinical significance. CT findings of 1523 patients, who underwent PNS CT with no history of sinus surgery, were reviewed, and prevalence of each anatomic variation and its relationship with mucociliary clearance pathway was evaluated. Two categories of anatomic variations were encountered. The first group included variations of the turbinates, such as concha bullosa(28.6%), paradoxical middle turbinate(31.5%), of the uncinate process, such as medially bent or folded(36.3%), laterally bent(3.7%) or uncinate bulla(0.5%), of the ethmoidal sinus, such as Haller's cell(28.2%), large agger nasi cell(9.6%) or large ethmoidal bulla(23.5%) and nasal septal deviation(24.1%), which might cause obstruction of mucociliary clearance pathway and thus give rise to secondary obstructive sinusitis. The second group included Onodi cell(1.4%) and medial ...

1994-09-01

104

Dead-time calibrator  

International Nuclear Information System (INIS)

... interval analyzers counting techniques discriminators electronic circuits

106

The Pinch Technique and its Applications to Non-Abelian Gauge Theories  

CERN Document Server

Describes the Pinch Technique for constructing Green's functions for elementary particle theorists and graduate students.

2010-01-01

107

Potential benefits of using commercial simulators to test equipment control systems  

Energy Technology Data Exchange (ETDEWEB)

Motivation is given for a technique to more thoroughly test semiconductor equipment control systems. A description is given of a simulator-based control system testing technique. Potential benefits that could be realized by using this technique in the semiconductor industry as well as benefits documented by using this technique in other industries are described. Specific requirements for using the technique in the semiconductor industry are outlined. A summary of a survey of nine commercial simulation systems is given. Finally, the outcome of the survey is compared with the requirements for using the technique.

1997-09-01

108

Utilization of Tc-99m-TBI as a myocardial perfusion agent in exercise studies: Comparison with Tl-201 thallous chloride and examination of its biodistribution in humans  

Energy Technology Data Exchange (ETDEWEB)

Twenty-four patients were studied with both /sup 201/Tl-thallus chloride and /sup 99m/Tc-TBI scintigraphy following exercise. Comparison of the two agents in detecting segmental myocardial ischemia and scar was made in 18 patients with evidence of coronary artery disease on /sup 201/Tl-thallous chloride scintigraphy. Agreement between the two studies was observed in 77% (125 of 162) of left ventricular segments, suggesting that /sup 99m/Tc-TBI can be used as a myocardial perfusion agent. Limitations were related to early high background activity from lungs and liver. The high lung activity and early myocardial redistribution within the 1st hour contributed to the failure of /sup 99m/Tc-TBI to detect 16 segmental defects seen in the immediate post-exercise thallous chloride scan. Persistently high liver activity additionally affected accurate interpretation in the left ventricular segments close to the diaphragm. Improvement in the accuracy of /sup 99m/Tc-TBI stress studies might be ...

1986-10-01

109

Usefulness of myocardial imaging by [sup 123]I-MIBG in assessment of diabetic neuropathy  

Energy Technology Data Exchange (ETDEWEB)

In diabetic patients with autonomic neuropathy, it is suggested that there is a reduced uptake of [sup 123]I-metaiodobenzylguanidine (MIBG) in the heart. We compared the difference of myocardial [sup 123]I-MIBG accumulation between 4 diabetic patients with triopathy and 6 patients without it. In all 10 patients, coronary angiography and [sup 201]Tl imaging (rest and 4 hours later) were performed. [sup 123]I-MIBG (111 MBq) was administered intravenously and its imaging was recorded on 15 minutes and 4 hours after injection. In all 4 cases with triopathy, [sup 123]I-MIBG imaging showed defect in apical and inferior region. In 2 out of 6 cases without triopathy, rapid clearance was noticed in apical and inferior region. There was no significant stenosis in right coronary artery and no defect in initial and delayed [sup 201]Tl images in all cases. We concluded that diabetic autonomic neuropathy in the heart was prominent in apical and inferior region and [sup ...

1993-10-01

110

Tribo-characteristics of self-lubricating ball bearings for the LE-7 liquid hydrogen rocket-turbopump  

Energy Technology Data Exchange (ETDEWEB)

The tribo characteristics of self-lubricating 40-mm-bore ball bearings with a retainer of glass cloth-polytetrafluoroethylene (PTFE) laminate, which has elliptical pockets with a large pocket clearance, were tested under thrust loads at speeds up to 50,000 rpm, 2 million DN, in liquid hydrogen (LH2) and in liquid nitrogen (LN2). During testing, the bearing torque, outer-race temperature, and electric resistance between the inner and outer races were monitored to verify the formation and rupture of a PTFE transfer film. Testing showed that the bearings having the elliptical retainer pockets were superior to the conventional bearings with circular pockets. It was determined that, at the maximum inner race spinning velocity of about 5 m/s, a PTFE transfer film could sustain the maximum Hertz stress, up to about 2000 N/sq mm, in LH2, without severe film rupture resulting in bearing seizure. In LN2, the critical load capacity of PTFE transfer film with bearing seizure ...

1993-07-01

111

The chemistry of technetium(V) complexes containing tetradentate amine oxime ligands  

International Nuclear Information System (INIS)

Technetium-99m was previously shown to form a stable, neutral and lipopholic complex with propylene amine oxime, PnAO. This Tc-99m-PnAO complex was shown to efficiently extracted by normal brain. However, it is not sufficiently retained in the brain to image its cerebral distribution using convertional SPECT (single-photon emission computerized tomography) instrumentation. A number of derivatives of PnAO have been synthesized and their technetium-99m complexes have been biologically evaluated. A number of these have been shown to have high brain uptake without exhibiting the rapid cerebral clearance that was observed with Tc-99m-PnAO. To better understand the chemistry of these potential brain imaging agents, a number of technetium-99 complexes of derivatives of PnAO have been synthesized and characterized. Substituents on the tetradentate amine oxime backbone were varied to probe the effect(s) of these structural changes on the properties of the resultant Tc(V) ...

112

Safety and Environmental Aspects of Inertial Fusion Energy: An Overview of Recent Activities and Developments in the United States  

International Nuclear Information System (INIS)

During the past 2 yr, significant progress has been made in several areas related to the safety and environmental (S and E) aspects of inertial fusion energy (IFE). An updated methodology has been developed, and accident analyses have been performed for two IFE conceptual power plants and a target fabrication facility. Parallel to the consequence analyses of different accident scenarios, ongoing studies of accident initiating events are being used to support safety assessment and create a basic framework of types of events to consider in future risk characterization of new plant designs. Target designers/fabrication specialists have been provided with ranking information related to the S and E characteristics of candidate target materials. We have revisited waste management options for IFE, introducing the concept of clearance versus the traditional shallow land burial. A brief summary of results in each of these activities is given, and plans for future work are ...

2003-05-01

113

Radioiodinated peanut lecitin: A potential radiopharmaceutical for immunodetection of carcinoma expressing the T antigen  

International Nuclear Information System (INIS)

The Thomsen-Friedenreich (T) antigen, #betta#-D-Gal-(1->3)-#alpha#-D-GalNAc, is exposed in reactive form on many human adenocarcinomata, but not on corresponding benign tissues. Peanut lectin (PNA) has a strong binding affinity for the T antigen and reportedly binds preferentially to certain malignant tissues. We investigated the potential of radio-labelled PNA as a tumour localising agent in an animal model system using a mouse lymphoma (RI) shown to bind fluorescein-labelled PNA in vitro. The radio-iodinated lectin showed good tumour localisation and rapid blood clearance. Clear images of tumours were obtained, in serial scintigraphic imaging, by 24 and 48 h. No blood background subtraction was necessary. Biodistribution studies revealed tumour to blood ratios in mice were 6:1 (at 24 h) and 17:1 (at 48 h), and tumour to muscle ratios were 34:1 (at 24 h) and 40:1 (at 48 h). Rapid in vivo breakdown of _1_2_5I-PNA led to some localisation of free iodide in the ...

1983-01-01

114

Pharmacokinetics of multiple doses of valsartan in patients with heart failure.  

Science.gov (United States)

Angiotensin II has adverse actions in heart failure including vasoconstriction, aldosterone secretion, and activation of the sympathetic nervous system. Valsartan, a potent specific angiotensin II type 1 receptor blocker, may produce beneficial effects in heart failure. The purpose of this study was to evaluate the steady-state pharmacokinetics of valsartan 40, 80, and 160 mg each given every 12 h for 7 days in heart failure patients. Eighteen patients with chronic stable heart failure and left ventricular ejection fractions power model, showed that doubling the dose increased the AUC and Cmax 1.8 times. The pharmacokinetics of valsartan are predictable in heart failure patients within the dose range of 40-160 mg BID. Age did not appear to have influenced the valsartan clearance in heart failure patients. The pharmacokinetic values were higher in heart failure patients than in healthy volunteers. All doses were generally safe and well tolerated.(max) (max) ...

2002-11-01

115

Noninvasive analysis of skin iron and zinc levels in beta-thalassemia major and intermedia  

Energy Technology Data Exchange (ETDEWEB)

Diagnostic x-ray spectrometry, a method based on x-ray fluorescence analysis, was used for noninvasive determination of iron and zinc in two distinct skin areas, representing predominantly dermal and epidermal tissues, in 56 patients with beta-thalassemia major and intermedia. The mean iron levels in the skin of patients with beta-thalassemia major and intermedia were elevated by greater than 200% and greater than 50%, respectively, compared with control values. The zinc levels of both skin areas examined were within the normal range. The data indicate that the rate and number of blood transfusions, which correlated well with serum ferritin levels (r . 0.8), are not the only factors that determine the amount of iron deposition in the skin (r less than 0.6). Other sources of iron intake contribute to the total iron load in the tissues, particularly in patients who are not given multiple transfusions. The noninvasive quantitation of skin levels may reflect the extent of iron deposition ...

1985-01-01

116

Murine respiratory mycoplasmosis (MRM) in C57BL/6N and C3H/HeN mice: strain differences in early host responses and exacerbation by nitrogen dioxide  

Energy Technology Data Exchange (ETDEWEB)

The studies reported here used genetic differences in susceptibility of C57BL/6N and C3H/HeN mice and exacerbation of the disease by nitrogen dioxide (NO/sub 2/) as tools in assessing the role of early host responses in the pathogenesis of MRM. The two strains did not differ in susceptibility to infection, but C3H/HeN mice were more susceptible to and had increased severity of lung lesions 14 days after intranasal inoculation as determined by 50% biological endpoints and morphometric analysis of tissues. Exposure to NO/sub 2/ for 4 hours prior to exposure to infectious aerosols exacerbated murine respiratory mycoplasmosis (MRM) by 7 days after exposure in both mouse strains. NO/sub 2/ appeared to affect host lung defense mechanisms responsible for limiting mycoplasmal growth in the lungs. The NO/sub 2/ exposure concentration required for this effect varied with the genetic background of the host, the dose of mycoplasmas administered, and the endpoint measured. Pulmonary ...

1987-01-01

117

Loss of PINK1 function decreases PP2A activity and promotes autophagy in dopaminergic cells and a murine model  

British Library Electronic Table of Contents (United Kingdom)

Parkinson's disease (PD) is the most common neurodegenerative movement disorder. Mutations in PTEN-induced kinase 1 (PINK1) are a frequent cause of recessive PD. Autophagy, a pathway for clearance of protein aggregates or impaired organelles, is a newly identified mechanism for PD development. However, it is still unclear what molecules regulate autophagy in PINK1-silenced cells. Here we report that autophagosome formation is promoted in the early phase in response to PINK1 gene silencing by lentivirus transfer vectors expressed in mouse striatum. Reduced PP2A activity and increased phosphorylation of PP2A at Y307 (inactive form of PP2A) were observed in PINK1-knockdown dopaminergic cells and striatum tissues. Treatment with C2-ceramide (an agonist of PP2A) reduced autophagy levels in PINK...

2011-01-01

118

Heat transfer augmentation due to surface radiative exchange effect of internal fins in an annulus  

International Nuclear Information System (INIS)

Heat transfer augmentation due to surface radiation in an annulus with fins was investigated both theoretically and experimentally for fully developed laminar flow. The system considered in the present study was an array of axially internal and straight fins attached to the outer tube wall. Analytical solutions were given for 4, 8, 16, 24, 32 fins and for the ratios of the fin height to the passage clearance, 0, 0.2, 0.4, 0.5, 0.6, 0.8. The experiments were performed with air as the working fluid for radius ratio of 1.45, 16 fins and for Reynolds numbers ranging from 500 to 2000. The numerically predicted results of the convective/radiative heat transfer for the present case were in good agreement with the experimental data. It was found that the heat transfer augmentation coefficient attained a maximum value of 1.45 for 32 fins and for a dimensionless fin height of 0.65.

1987-08-01

119

Four-inch pipe whip test under BWR LOCA conditions effect of overhang length  

Energy Technology Data Exchange (ETDEWEB)

Pipe whip tests or jet discharge tests have been performed at the Japan Atomic Energy Research Institute, which simulate the instantaneous guillotine break of primary coolant piping in nuclear power plants. This paper describes the results of the 4-inch pipe whip tests(RUN 5407, 5501, 5504, 5603), under the BWR LOCA conditions, which were performed from 1979 to 1981. The test pressure was 6.8 MPa and test temperature 285/sup 0/C. In these tests, clearance was kept constant at the value of 100 mm and overhang lengths were 250, 400, 550 and 1,000 mm, respectively. The main purpose of these tests is to investigate the effect of overhang length on pipe whip behavior. From the tests results, the pipe movement is effectively limited by the restraints if the overhang length is 250 mm or 400 mm. The deformation of the test pipe and restraints becomes large with increasing overhang length. It is clarified that the test pipe collapses at the setting point of the restraints ...

1983-03-01

120

Evaluation of the hepatobiliary function with "9"9Tc"m EHIDA imaging during total parenteral nutrition  

International Nuclear Information System (INIS)

Fourteen surgical patients with non-hepatobiliary diseases were studied with "9"9Tc"m EHIDA imaging to evaluate the effect of total parenteral nutrition (TPN) on the hepatobiliary function. The duration of TPN ranged from 6 to 56 days; for 10 of the 14 patients it was between 6 to 10 days. The results showed that: (1) 11 of 14 patients had abnormal scintigraphic features. The most prominent findings were delayed liver excretion and prolonged blood clearance time. This fact suggests that not only the rate of excretion of the bile from the liver is decreased but the uptake ability of the hepatocyte is also impaired. (2) The effect of TPN on liver function is reversible. The authors conclude that in order to prevent irreversible damage of hepatobiliary function caused by TPN, the duration of TPN should not be too long and oral intake of nutrients should be resumed as soon as possible. (author). 9 refs, 3 figs, 3 tabs.

1988-08-15

121

Effects of the. cap alpha. -adrenoceptor antagonists phentolamine, phenoxybenzamine, and Idazoxan on sympathetic blood flow control in the periodontal ligament of the cat  

Energy Technology Data Exchange (ETDEWEB)

Blood flow changes in the periodontal ligament (PDL) were measured indirectly by monitoring the local clearance of /sup 125/I/sup -/ during electric sympathetic nerve stimulation or close intra-arterial infusions of either noradrenaline (NA) or adrenaline (ADR) before and after administration of phentolamine (PA), phenoxybenzamine (PBZ) or Idazoxan (RX). At the doses used in the present study, PA was the only antagonist that significantly reduced the blood flow decrease seen on activation of sympathetic fibers, although PBZ also reduced this response. Idazoxan, however, did not induce the consistent effect on blood flow decreases seen on sympathetic activation. All three ..cap alpha..-adrenoceptor antagonists almost abolished the effects of exogenously administered NA and ADR. The results suggest the presence of functional post-junctional adrenoceptors of both the ..cap alpha.. 1 and ..cap alpha.. 2 subtypes in the sympathetic regulation of the blood flow in the ...

1988-01-01

122

Effect of vasopressin on ependymal and capillary permeability to tritiated water in cat  

Energy Technology Data Exchange (ETDEWEB)

Ependymal cells line the cerebral ventricles forming the interface that separates the cerebrospinal (CSF) and interstitial fluids (ISF). Extracellular molecules move between ependymal cells, whereas lipid soluble molecules pass both between and through cells. We measured the transfer of tritiated water (TOH) from CSF to blood across the ependymal and capillary interfaces by ventriculocisternal (VC) steady-state tissue clearance. Adult cats anesthetized with pentobarbital sodium underwent VC perfusion with the extracellular marker (/sup 14/C)sucrose and TOH added to the artificial CSF. Brain tissue was analyzed for depth of penetration of the isotopes into periventricular gray matter. We found that TOH distribution space was lower than expected from water content measurements, whereas sucrose space was normal. Using VC steady-state equations we calculated an ependymal permeability that was similar to the permeability of the cerebral capillary. When arginine ...

1986-09-01

123

Effect of rib height and pitch of the thermal performance of a passage disturbed by detached solid ribs  

Energy Technology Data Exchange (ETDEWEB)

Laser holographic interferometry and pressure measurements are presented for the effects of rib-to-duct height ratio (H/2B), rib pitch-to-height ratio (Pi/H), and Reynolds number (Re) on the spatially periodic-fully developed turbulent heat transfer and friction in a rectangular duct of width-to-height ratio of 4:1 with an array of ribs detached from one wall at a clearance to rib-height ratio of 0.38. The ranges of H/2B, Pi/H, and Re examined were 0.13 to 0.26, 7 to 13, and 5 {times} 10{sup 3} to 5 {times} 10{sup 4}, respectively. The difference in the H/2B dependence of the thermal performance between the detached and attached solid-rib array is documented H/2B = 0.17 and Pi/H = 10 are found to provide the best thermal performance for the range of parameters tested. Compact heat transfer and friction correlations are developed. Additionally, it is found that heat transfer augmentation with a detached solid-rib array is superior to with a detached perforated-rib ...

1998-07-01

124

Diagnosing mechanical changes: A test of the machine condition monitoring concept  

Energy Technology Data Exchange (ETDEWEB)

BC Hydro recently conducted a demonstration test of a bearing condition monitor. The test, at the 529-MW Kootenay Canal project, proved the ability of the monitor to detect machine condition faults. The capability to detect changing conditions during normal operation of hydroelectric machines gives hydro plant owners the opportunity to anticipate needed maintenance and ultimately to reduce the number of equipment failures. BC Hydro intends to install bearing condition monitors, as well as windings monitors, brushgear monitors, environmental monitors, and other selected systems in as many as 46 of its hydro generators. BC Hydro analyzed forced outages between 1985 and 1989 in its hydro system to identify which parts of a generating unit resulted in the highest number of hours of outage. From there, the utility has formulated a concept for a machine condition monitoring system. To keep the system cost effective, it will be developed in modules. In this way, users can pick and choose from ...

1993-05-01

125

Composite electrode substrate for fuel cell requiring no separator plate and its production method; Separeta ban wo fuyo tosuru nenryo denchiyo fukugo denkyoku kiban oyobi sono seizoho  

Energy Technology Data Exchange (ETDEWEB)

This invention relates to the production method of composite electrode substrate for fuel cell. An impermeable material is used for edge sealant. The sealant is put in the clearance between two electrodes consisting of porous carbon material via thermoplastic resin sheet, and heated while being pressed. This production method increases the adherence between the porous carbon bodies and reduces the contact resistivity at the joint interface. Consequently, it becomes possible to produce the composite electrode for fuel cell without separator, resulting in simplification of assembly work, weight reduction, and downsizing. The preferable porous carbon body is made from shrinkage-treated fiber. After sheet forming, the thermosetting resin is impregnated, and then it is burnt to carbonization. Or mixed sheet of rayon and acrylic fiber is laminated to be heated and pressed without impregnating the resin. The pressed resin is then burnt to carbonization. The preferable ...

1996-04-12

126

Analysis of high turbulence combustion in a direct-injection diesel engine with high squish combustion chamber; CFD ni yoru ko squish nenshoshitsunai koranryu diesel nensho no kaiseki  

Energy Technology Data Exchange (ETDEWEB)

Simultaneous reduction of NO{sub x} and particulate emissions in a direct-injection diesel engine has been realized experimentally with a high squish combustion chamber. The purpose of this study is to investigate the effects of high squish combustion chamber on combustion process in detail. Engine CFD code FREC was used for the analysis. The results show the followings. (1) Compared with standard toroidal chamber, high squish chamber generates high turbulence due to strong squish and large expansion flow is caused in the cavity. (2) Rich and high-turbulence combustion, which forms ring area in the cavity under squish lip, continues during the combustion. (3) The high squish combustion chamber keeps fuel long in the cavity and less hid spreads out to the cold clearance volume. (4) For the condition of retarded injection timing, the effect of high squish is mainly observed at initial combustion and high swirl is more effective at diffusion combustion. (author)

1999-08-25

127

In vitro and in vivo analysis of pegulated Avidin  

Energy Technology Data Exchange (ETDEWEB)

Full text: In 1995, we demonstrated the use of pretargetting three steps method and biotinylated tetracycline using radiolabelled {sup 99m}Tc-DTPA-biocytinamide for the detection of tumour cells in (C57B1/6 x BALB/C) F1 mice with E-3 thymoma. The three steps were (1) IP injection of biotinylated-tetracycline conjugate (1:1) ratio, (2) 96 hours later Avidin/Streptavidin was injected, and (3) 24 hours after (2), {sup 99m}Tc-biocytinamide -cDTPA was injected. Mice were sacrificed 16/24 h after (3) by cervical dislocation. Biodistribution of radioactivity tumour to blood, liver, bone were T:B1= 15.0, T:Li= 5.08, T:Bo=15.0. The percentage of injected dose per g was T= 3.15% and B1= 0.21%. To prolong circulation of Avidin and therefore its uptake into tumour, Avidin was covalently bound to polyethylene-glycol (PEG20 KD) at the molar ratio of PEG:Avidin 100:1 and 400:1. The pegulated Avidin was then cleared from the circulation using Dextran-70-Biotin. The distribution and binding were ...

1997-09-01

128

Camouflage and Deception Techniques for Urban Warfare.  

Science.gov (United States)

A discussion of historical techniques and future programs dealing with camouflage in urban warfare. The report emphasizes current capabilities in camouflage and deception and concludes that camouflage and deception techniques when used properly can provid...

1980-01-01

129

Bibliography on augmentation of convective heat and mass transfer  

International Nuclear Information System (INIS)

Heat transfer augmentation has developed into a major specialty area in heat transfer research and development. A bibliography of world literature on augmentation is presented. The literature is classified into passive augmentation techniques, which require no external power, and active techniques, which do require external power. The fourteen techniques are grouped in terms of their application to the various modes of heat transfer. Mass transfer is included for completeness. Key words are included with each citation for technique/mode identification. The total number of publications cited is 1,967, including 75 surveys of various techniques and 42 papers on performance evaluation of passive techniques. Patents are not included as they will be the subject of a future topical report.

1979-01-01

130

SQUID Eddy Current Technique Applying Conformable Eddy ...  

Science.gov (United States)

... Accession Number : ADD344580. Title : SQUID Eddy Current Technique Applying Conformable Eddy Current Probes,. Corporate Author : ...

131

An evaluation of planning techniques for stereotactic body radiation therapy in lung tumors  

UK PubMed Central (United Kingdom)

PurposeTo evaluate four planning techniques for stereotactic body radiation therapy (SBRT) in lung tumors.Methods...Full Text Available

2008-04-01

132

A High Throughput Combinatorial Library Technique for Identifying Formalin-Sensitive Epitopes  

UK PubMed Central (United Kingdom)

We present a technique for identifying the amino acids responsible for a loss of immunoreactivity in response to treating an antigen with a chemical modifier. This is of particular interest...Full Text Available

2006-12-20

134

Techniques and tools for condition monitoring and life prediction of fluid power controls used in fuel handling systems of PHWRs  

International Nuclear Information System (INIS)

Various diagnostics techniques for condition monitoring and life prediction of fluid power components and system are discussed. Though some of the techniques are very promising but may not be accepted because of increase in the instrumentation, it is planned to implement these techniques on various circuits of Fluid Power Lab for further improving and developing these for direct implementation in various fluid power circuits of power reactors. (author). 6 figs.

136

Researches on gear fault diagnostic techniques  

Science.gov (United States)

Attention is given to recent research on gear fault diagnostic techniques. A mathematic model for vibration signals of defective gears is presented. Novel methods of gear fault diagnosis, such as zoom complex envelope analysis, wideband demodulation techniques, bispectrum analysis, correlation spectrum analysis, and maximum entropy spectrum analysis, are demonstrated. The wide-band demodulation technique is found to exhibit a high SNR. Bispectrum and correlation spectrum are excellent for some mechanical fault forms.

1992-10-01

138

Practical application of a simplified vitamin B_1_2 radioassay  

International Nuclear Information System (INIS)

... blood serum patients radioimmunoassay sampling tracer techniques isotope

143

Environmental assessment of coal waste mounds in Japan using remote sensing techniques  

Energy Technology Data Exchange (ETDEWEB)

Focuses on the application of remote sensing techniques to the study of coal waste mounds. The situation at the coal waste mounds in Fukuoka, Japan is cited. Guidelines on film parameters, photographic keys and tasks required to inventory, monitor and manage coal waste mounds in Japan are addressed. Application of photogrammetry, remote sensing, aerial photography and satellite imagery techniques in monitoring spoil banks is reviewed. Applicability of the techniques is discussed. 24 refs.

1993-01-01

146

Biology-inspired Architecture for Situation Management  

Science.gov (United States)

Situation Management is a rapidly developing science combining new techniques for data collection

2006-01-01

151

Feynman diagrams and a combination of the integration by parts and the integration by fractional expansion techniques  

International Nuclear Information System (INIS)

In this paper, we show how to improve and extend the integration by fractional expansion technique (IBFE) by applying it to certain families of scalar massive Feynman diagrams. The strategy is based on combining this method together with the integration by parts technique. In particular, we want to calculate certain Feynman diagrams which have a triangle loop as a subgraph. The main idea is to use the integration by parts technique in this subgraph in order to simplify the topology of the original diagram in which it is immersed, using then, in a second step, the IBFE technique. The result we have obtained, after the application of both techniques, represents a simplification in the complexity of the solution, compared with having used only the IBFE technique.

2010-01-15

152

The use of different techniques for determination of pitting corrosion potential of austenitic stainless steel  

International Nuclear Information System (INIS)

Three different techniques for pitting corrosion potential measurement on austenitic stainless steel (Fe18Cr10Ni) were compared: conventional polarization method, a new Avesta electrochemical corrosion measurement cell and a scratch technique. Special attention was paid to the effects of crevice corrosion during pitting corrosion potential measurement and to their elimination. Development of a rapid test technique for reliable pitting corrosion potential determination was aimed at and resulted from comparison of the different techniques.

1991-07-01

153

In vitro and in vivo evaluation of novel ligands for radioimmunotherapy  

Energy Technology Data Exchange (ETDEWEB)

Novel ligands cis-2,6-bis[N,N-bis(carboxymethyl)aminomethyl]-1-piperidineacetic acid (PIP-DTPA), cis-[(1R,11S)-6,9,15-Tris-carboxymethyl-3,6,9,15-tetraazabicyclo[9.3.1] pentadec-3-yl]-acetic acid (PIP-DOTA), cis-{l_brace}2,7-bis-[bis-carboxymethyl-amino)-methyl]-azepan-1-yl{r_brace}-acetic acid (AZEP-DTPA), [2-(4,7-bis-carboxymethyl-[1,4,7]triazacyclononan-1-yl-ethyl] -2-carbonylmethyl-amino]-tetraacetic acid (NETA) and [{l_brace}4-carboxymethyl-7-[2-(carboxymethylamino)-ethyl]-perhydro-1,4,7-triazonin-1-yl{r_brace}-acetic acid (NPTA) are investigated as potential chelators of {sup 177}Lu, {sup 9}Y, {sup 212}Pb and {sup 213}Bi for radioimmunotherapy (RIT). The new ligands are radiolabeled with {sup 177}Lu, {sup 86/88/9}Y, {sup 203}Pb and {sup 205/6}Bi, and in vitro stability and in vivo stability of the radiolabeled complexes are assessed in human serum and athymic mice, respectively. In vitro studies indicate that all radiolabeled complexes with the exception of {sup 9}Y-AZEP-DTPA are ...

2006-05-15

154

A common framework for aspect mining based on crosscutting concern sorts  

CERN Document Server

The increasing number of aspect mining techniques proposed in literature calls for a methodological way of comparing and combining them in order to assess, and improve on, their quality. This paper addresses this situation by proposing a common framework based on crosscutting concern sorts which allows for consistent assessment, comparison and combination of aspect mining techniques. The framework identifies a set of requirements that ensure homogeneity in formulating the mining goals, presenting the results and assessing their quality. We demonstrate feasibility of the approach by retrofitting an existing aspect mining technique to the framework, and by using it to design and implement two new mining techniques. We apply the three techniques to a known aspect mining benchmark and show how they can be consistently assessed and combined to increase the quality of the results. The ...

2006-01-01

155

A Study on TOFD Inspection Using Phased Array Ultrasonic Technique  

Energy Technology Data Exchange (ETDEWEB)

The techniques in order to measure the depth of defect in weldment and structure accurately have been developed. Many researches have made efforts to develop the methods for the accurate depth sizing of defect. TOFD is known as the most accurate method of various methods for measuring depth sizing. However, there is a possibility to miss defects because of the limitation of beam coverage for the ultrasound incident angle. In this study, the results for detectability and depth sizing using phased array ultrasonic technique for thick body were compared with those of conventional TOFD technique. It was experimentally confirmed that the phased array ultrasonic TOFD technique gives good detectability and accurate depth measurement for the various types of defects. The phased array ultrasonic TOFD technique developed in this study will contribute to increase the inspection reliability in ...

2005-08-15

156

Synthesis characterization and biological evaluation of a novel mixed ligand "9"9"mTc complex as potential brain imaging agent  

International Nuclear Information System (INIS)

One approach in the design of neutral oxotechnetium complexes is based on the simultaneous substitution of a tridentate dianionic ligand and a monodentate monoanionic coligand on a [Tc(V)O]"+"3 precursor. Following this ''mixed ligand'' concept, a novel "9"9"mTc complex with N,N-bis(2-mercaptoethyl)-N'N'-diethylethylenediamine as ligand and 1-octanethiol as coligand is prepared and evaluated as potential brain radiopharmaceutical. Preparation of the complex at tracer level was accomplished by using "9"9"mTc-glucoheptonate as precursor. The substitution was optimized and a coligand/ligand ratio of 5 was selected. Under this conditions the labeling yield was over 80% and a major product (with radiochemical purity > 80%) was isolated by HPLC methods and used for biological evaluation. Chemical characterization at carrier level was developed using the corresponding rhenium complex as structural model. The Re complex was also prepared by substitution method and isolated as a crystalline ...

1998-08-01

157

Preparation of a high specific activity I-125 labeled styryl dye for leukocyte membrane labeling  

International Nuclear Information System (INIS)

The purpose of this work was to develop a high specific activity radioiodinated cell membrane probe for tracking lymphocytes in-vivo to replace the nucleus localizing, cytotoxic lipophilic chelates (In-111 oxine and Tc-99m HMPAO) currently used. Alkylation of parent dye 4-[2-[-N,N-didecylamino]phenyl]ethenyl pyridine with E-1-tributylstannyl-3-tosylpropene (prepared form E-1-tributylstannyl-1-propene-3-ol), gave a tributyltin precursor 1. Radiolabeled 3-[4-[2-[4-(N,N-didecylamino)phenyl]ethenyl]pyridino] E-[I-125]-1-iodopropene (2), was prepared from 1 using peracetic acid in acetonitrile/water. Labeling yields and specific activities achieved were 26% (#approx#2170 Ci/mmol), 40% (1220 Ci/mmol), and 55% (200 Ci/mmol) for nca, 0.4, and 2 nanomole carrier iodide runs respectively. Canine mixed leukocytes (0.5-1.0 x 10"8 cells) were labeled with 2 (67% and 42% yields for 200 Ci/mol and 1220 Ci/mmol preparations) and showed blood clearance similar to In 111 oxine. ...

1994-08-21

158

Novel bifunctional natriuretic peptides as potential therapeutics.  

Science.gov (United States)

Synthetic atrial natriuretic peptide (carperitide) and B-type natriuretic peptide (BNP; nesiritide) are used to treat congestive heart failure. However, despite beneficial cardiac unloading properties, reductions in renal perfusion pressures limit their clinical effectiveness. Recently, CD-NP, a chimeric peptide composed of C-type natriuretic peptide (CNP) fused to the C-terminal tail of Dendroaspis natriuretic peptide (DNP), was shown to be more glomerular filtration rate-enhancing than BNP in dogs. However, the molecular basis for the increased responsiveness was not determined. Here, we show that the DNP tail has a striking effect on CNP, converting it from a non-agonist to a partial agonist of natriuretic peptide receptor (NPR)-A while maintaining the ability to activate NPR-B. This effect is specific for human receptors because CD-NP was only a slightly better activator of rat NPR-A due to the promiscuous nature of CNP in this species. Interesting, the DNP tail alone had no effect ...

2008-10-21

159

Natriuretic peptides in vascular physiology and pathology.  

Science.gov (United States)

Four major natriuretic peptides have been isolated: atrial natriuretic peptide (ANP), brain natriuretic peptide (BNP), C-type natriuretic peptide (CNP), and Dendroaspis-type natriuretic peptide (DNP). Natriuretic peptides play an important role in the regulation of cardiovascular homeostasis maintaining blood pressure and extracellular fluid volume. The classical endocrine effects of natriuretic peptides to modulate fluid and electrolyte balance and vascular smooth muscle tone are complemented by autocrine and paracrine actions that include regulation of coronary blood flow and, therefore, myocardial perfusion; modulation of proliferative responses during myocardial and vascular remodeling; and cytoprotective anti-ischemic effects. The actions of natriuretic peptides are mediated by the specific binding of these peptides to three cell surface receptors: type A natriuretic peptide receptor (NPR-A), type B natriuretic peptide receptor (NPR-B), and type C natriuretic peptide receptor ...

2008-01-01

160

Mucociliary transport and upper airway disease  

International Nuclear Information System (INIS)

Mucociliary transport so critical in nasal, paranasal sinus, and middle ear physiology is impaired in chronic sinsusitis and otitis media by factors such as increased mucus viscoelasticity, decreased ciliary area, and primary or secondary ciliary immotility. We reviewed the pathophysiology of primary ciliary dyskinesia, otitis media with effusion, chronic sinusitis, and allergic rhinitis in terms of mucociliary transport. Subjects with primary ciliary dyskinesia may experience recurrent middle ear infection, chronic airway infection, predominantly lower-lobe bronchiectasis, male sterility, or situs inversus. Primary ciliary dyskinesia is sometimes difficult to diagnose in cases without situs inversus. Nasal nitric oxide concentration in such patients decreases, although why is unclear. Mutations may involve dynein arm intermediate chain 1 (DNAI1) or dynein arm heavy chain 5 (DNAH5). Mucociliary clearance decreases more in those with otitis media with effusion than ...

2010-05-01

161

Manufacture of IRDye800CW-coupled Fe3O4 nanoparticles and their applications in cell labeling and in vivo imaging  

Science.gov (United States)

BackgroundIn recent years, near-infrared fluorescence (NIRF)-labeled iron nanoparticles have been synthesized and applied in a number of applications, including the labeling of human cells for monitoring the engraftment process, imaging tumors, sensoring the in vivo molecular environment surrounding nanoparticles and tracing their in vivo biodistribution. These studies demonstrate that NIRF-labeled iron nanoparticles provide an efficient probe for cell labeling. Furthermore, the in vivo imaging studies show excellent performance of the NIR fluorophores. However, there is a limited selection of NIRF-labeled iron nanoparticles with an optimal wavelength for imaging around 800 nm, where tissue autofluorescence is minimal. Therefore, it is necessary to develop additional alternative NIRF-labeled iron nanoparticles for application in this area.ResultsThis study manufactured 12-nm DMSA-coated Fe3O4 nanoparticles labeled with a near-infrared fluorophore, IRDye800CW (excitation/emission, ...

2010-10-29

162

Ionising radiation effects on food packaging  

International Nuclear Information System (INIS)

The main aim of any food irradiation treatment is to guarantee the best safe quality of the products, reducing the spreading risk ("cross-contamination") for several food-associated diseases. Actually, over 40 countries provide clearances for the treatment of about 45 different types of foodstuffs. EU has to homogenise the situation within the associated States. With the European directive 1999/2/EC Italy, as other EU countries, already has brought into force their regulations to comply. The current Italian regulation on irradiation treatment of foodstuffs is referred since 1996 as follows: a) potatoes, onions and garlic; b) spices, herbs and condiments microbial. The new (April 2001) Italian law allows the possibility to ask for special permission of treatment for other foodstuff which is possible to treat in other E.U. countries. Large majority of foods are submitted to irradiation treatment after they have been packaged. In Dutch cases the study of radiation ...

2001-10-22

163

Experimental studies of 6-inch pipe whip tests under BWR LOCA conditions  

International Nuclear Information System (INIS)

Series of pipe rupture tests have been performed at the Japan Atomic Energy Research Institute to demonstrate the safety of the primary coolant circuits in the event of pipe rupture in nuclear power plants. The pipe whip tests have been conducted to study the dynamic response of the pipe and restraints. The results of the pipe whip tests using test pipes of 4-inch in diameter under the BWR LOCA conditions (285"0C, 6.8 MPa) were reported in the previous paper F8/5 of the 6th SMiRT. The present paper describes the results of the pipe whip tests using test pipes of 6-inch in diameter. The test pipe was made of Type 304 stainless steel and was 165.2 mm in outer diameter and 11.0 mm in thickness, and was fixed at the pipe support so that the length of the test section was 3000 mm. The restraints were made of Type 304 stainless steel and were 16.0 mm in diameter, and were set on the restraint support with the clearance of 100 mm. The overhang length was 300 mm or 700 mm ...

164

Evaluation of critical heat flux of tight lattice core with subchannel analysis code NASCA  

International Nuclear Information System (INIS)

Reduced-Moderation Water reactor (RMWR) is a light water breeder reactor developed by Japan Atomic Energy Research Institute (JAERI). The RMWR comprises tight lattice fuel assemblies with gap clearance of around 1.0 mm to reduce water volume ratio to achieve a high conversion ratio. It is important to estimate the thermal hydraulic safety margin of the tight lattice core of the RMWR. In the present study, the boiling transition (BT) prediction performance of the subchannel analysis code NASCA developed for the current BWR cores was assessed for series of tight lattice critical heat flux (CHF) experiments performed in JAERI. The test section was a 7-rod bundle with rod diameter of 12.3 mm, rod gap of 1.0 mm and heated length of 1.8m. Axial power distribution was flat. With a simple subchannel model, the code overestimates the critical power in the high mass velocity region, although the predicted critical powers in the low mass velocity region were in good agreement ...

2003-04-20

165

Enzyme induction in neonates after fetal exposure to antiepileptic drugs  

Energy Technology Data Exchange (ETDEWEB)

The /sup 13/C-AP breath test is shown to be a convenient, noninvasive method to monitor velocity and capacity of P450-dependent AP N-demethylation in infancy and childhood. According to /sup 13/C-AP breath tests, neonates have a very low capacity to eliminate /sup 13/CO/sub 2/, which is only 15 to 21% of the activity in adults. During the first year of life AP N-demethylation increases to reach its maximum at about 2 years; afterwards a slight decrease occurs. In 25 neonates exposed prenatally to different antiepileptic drugs /sup 13/C-AP breath test was efficiently used to prove that cytochrome AP N-demethylation was considerably stimulated. After primidone/phenobarbitone, especially in combination with phenytoin, /sup 13/C elimination reaches and even surpasses the range for older children. Valproate exposure during fetal life is not consistently followed by a significant increase in AP N-demethylation. The enzyme induction demonstrated by /sup 13/C-AP breath test was often ...

1983-01-01

166

Distributions of "1"3"7Cs, "2"0"1T1, "2"0"3Hg, "2"0"3Pb and "5"7Co in a rat hepatoma model. Comparison with "6"7Ga  

International Nuclear Information System (INIS)

The distribution of carrier-free "2"0"3Pb-acetate, "2"0"3HgCl_2, "5"7Cocl_2, "1"3"7CsCl and "2"0"1TlCl was investigated in rats bearing thigh-implanted Morris 7777 hepatomas. Viable and nonviable tumor tissue was collected in order to determine the relative affinities of the radiopharmaceutical for these tissues. The animals were sacrificed at 4, 24, 48, 72 and 96 hrs following intravenous injection. Washout of the radioisotope from the viable tumor tissue was rapid, the maximum concentration being reached on or before 4 hrs following injection. In contrast, residual activity within the nonviable tumor tissue decreased much more slowly and in some cases even increased with time. Viable tumor-to-muscle and nonvialbe tumor-to-muscle ratios for "2"0"3Pb, "2"0"3Hg and "5"7Co were comparable to the analogous ratios reported for "6"7Ga. However, none of these isotopes approached "6"7Ga as a potential tumor imaging agent because the large ratios were the result of low muscle uptake rather ...

167

Development of a new radiolabel (lead-203) and new chelating agents for labeling monoclonal anntibodies for imaging  

International Nuclear Information System (INIS)

High liver uptake and slow body clearance presently limit the usefulness of "1"1"1In labeled antibodies for tumor imaging. We have investigated "2"0"3Pb as an alternate and better antibody label. The DTPA and cyclohexyl EDTA (CDTA) conjugates of an anticolon carcinoma antibody, 17-1A were labeled (bicyclic anhydride method) with "2"0"3Pb and "1"1"1In with 60 and 90% labeling yields, respectively. The biodistribution of "2"0"3Pb-17-1A conjugates was compared with the corresponding "1"1"1In-labeled preparations and with "2"0"3Pb-DTPA, "2"0"3Pb-nitrate and nonrelevant antibody controls in normal and human tumor (SW948) xenografted nude mice at 24, and 96 hr. Lead-203-labeled CDTA and DTPA antibody conjugates gave similar in vivo distributions. Even though the lead bound to these chelate-antibody conjugates was more labile in serum and in vivo, compared to indium, it cleared much faster from the liver and the whole body. A new series of chelating agents based on the ...

1988-05-22

168

Decreased duration of pentobarbital-induced narcosis in immature and adult female rats prenatally exposed to cimetidine  

Energy Technology Data Exchange (ETDEWEB)

The effect of prenatal cimetidine exposure (PreCM) on the duration of pentobarbital-induced narcosis (DPN) was assessed in immature (14- and 28-day old) and adult (50-60-day old) male and female rats. PreCM exposure was accomplished by treating mothers with cimetidine (CM) (20 mg/kg, ip) daily for the last two days of gestation and then (0.01% in drinking water) throughout lactation. Pregnant mothers of untreated offspring (Con) received saline. PreCM decreased DPN to 505 +/- 33 min (from 611 +/- 23 min in Con) and 393 +/- 190 min (from 686 +/- 44 min in Con) in 14-day old male and female rats, respectively. Similarly, PreCM decreased DPN to 88 +/- 15 min (from 134 +/- 3 min in Con) and 102 +/- 19 min (from 171 +/- 44 min in Con) in 28-day old male and female rats, respectively. At 21 days, PreCM did not alter DPN in either sex. At 50-60 days, however, it decreased DPN to 144 +/- 41 min (from 238 +/- 7 min in Con) in females but had no effect in males; PreCM also increased the plasma ...

1986-03-01

169

Damages of mountings in HP- and MP-turbines; Schaeden an Vierzacken-Schaufelfuessen in HD- und MD-Turbinen  

Energy Technology Data Exchange (ETDEWEB)

Investigation of an HP-blade damage in 1996 and an MP-blade damage in 1007 at the mounting showed that fretting and creep fatigue had caused the damage. Break-down occurred when creep-related cracks developed between radial bridge to the upper blade tooth and weight relief boreholes. After disassembly of the HP-blades the lower blade tooth was found to be cracked after fretting (some cracks along the whole length of the tooth). The lower teeth of MP-bladedes showed merely superficial cracks (depth about 0.4mm). The massive cracks of the lower blade tooth were caused by instationary clearance changes combined with hard blade underground.(orig.) [German] Das Ergebnis der Untersuchung nach einem HD-Schaufelschaden 1996 sowie einem MD-Schaufelschaden 1997 an der Vierzackenfussbefestigung ergab Zeitstanderschoepfung und Fretting als auszuloesende Schadensmechanismen. Die Havarien wurden durch zeitstandbedingte Brueche zwischen Radienuebergang zum oberen Schaufelzacken ...

1998-07-01

170

Biokinetic and dosimetric studies of {sup 188}Re-hyaluronic acid: a new radiopharmaceutical for treatment of hepatocellular carcinoma  

Energy Technology Data Exchange (ETDEWEB)

Hepatocellular carcinoma (HCC) is the most common primary liver cancer and has very limited therapeutic options. Recently, it has been found that hyaluronic acid (HA) shows selective binding to CD44 receptors expressed in most cancer histotypes. Since the trend in cancer treatment is the use of targeted radionuclide therapy, the aim of this research was to label HA with rhenium-188 and to evaluate its potential use as a hepatocarcinoma therapeutic radiopharmaceutical. Methods: {sup 188}Re-HA was prepared by a direct labelling method to produce a ReO(O-COO){sub 2}-type coordination complex. {sup 188}Re-HA protein binding and its stability in saline, phosphate buffer, human serum and cysteine solutions were determined. Biokinetic and dosimetric data were estimated in healthy mice (n=60) using the Medical Internal Radiation Dose methodology and mouse model beta-absorbed fractions. To evaluate liver toxicity, alanine aminotranferase (AST) and aspartate aminotranferase (ALT) levels in mice ...

2009-08-15

171

A case of wound intake of plutonium isotopes and 241Am in a human: application and improvement of the NCRP wound model.  

Science.gov (United States)

Plutonium isotopes (239Pu and 238Pu, and 241Am) with a total activity of 269 kBq were accidentally deposited in a puncture wound of the right index finger of a nuclear worker at the Mayak Production Association. Tissues surrounding the wound site contaminated with radionuclides were excised 4.5 h after the injury. Residual contamination within the wound amounted to 0.05% of the initial contamination. The 10-d therapy with CaNa3-diethylene triamine pentaacetate acid (CaNa3-DTPA) was performed in parallel with in vivo measurements of the wound site and daily urine bioassays. The wound intake of radionuclides was consistent with two forms of radioactive materials detected within the wound site, i.e., soluble compounds and a large fragment, which was completely removed by excision. On day 9 after the injury, the clearance rate from the wound site was 1.8 times higher than the rate predicted by the National Council on Radiation Protection and Measurements (NCRP) model ...

2010-10-01

172

The Experimental Determination of the Thermodynamic and Hydrodynamic Mechanism of Augmented Flow Boiling in Tubes.  

Science.gov (United States)

Experimental results are presented for a new and unique heat transfer augmentation technique in tubes. The technique consists of inserting a porous mesh structure into the flow passage of the tube. Due to the increased degree of turbulence, both the singl...

1970-01-01

173

The Effect of Different Timber Harvesting Techniques on Plethadontid Salamander Populations.  

Science.gov (United States)

This investigation will explore the effect that current timber extraction techniques have on plethadontid salamander populations in ... group selection, and two-age harvest. Broad scale timber extraction can d...

174

Robust principal axes determination for point-based shapes using least median of squares  

UK PubMed Central (United Kingdom)

A robust technique for determining the principal axes of a 3D shape represented by a point set, possibly with noise, is presented. We use techniques from robust statistics to guide the classical...Full Text Available

2009-04-01

175

Regulation of ROMK1 Channels by Protein-tyrosine Kinase and -tyrosine Phosphatase*  

UK PubMed Central (United Kingdom)

We have used the two-electrode voltage clamp technique and the patch clamp technique to investigate the regulation of ROMK1 channels by protein-tyrosine phosphatase (PTP) and protein-tyrosine...Full Text Available

2001-03-09

177

Optimal scheduling of power systems with pumped hydropower storage plants adopting nonlinear programming techniques  

Energy Technology Data Exchange (ETDEWEB)

The paper is concerned with the economic operation of power systems comprising pumped storage and thermal plants. In power systems, pumped storage plants may receive the energy required for pumping water either from the system in which they are integrated or from a neighbouring system. Therefore, two mathematical formulations of the problem are presented depending on the source of energy during pumping. In both cases, the problem is reduced to a non linear optimization problem. Two numerical techniques are suggested for the solution of this optimization problem, namely the Lagrangian Multipliers technique and the Rosen Gradient Projection technique. Numerical examples are presented to demonstrate the techniques. Although the Lagrangian Multipliers technique has the advantage of being a well known technique, however, computer wise, the Rosen Gradient Projection ...

1980-12-01

178

Novel Technique for Aerodynamic Force Measurement in Shock Tubes.  

Science.gov (United States)

For aerodynamic force measurement in the ISL shock tunnel, the authors have developed a novel measurement technique. Its key feature is a mounting support, which releases the test model and tightens it again after a free flight duration of 10 to 15 millis...

1989-01-01

179

Name techniques in Canada: current trends in utilization rates and recommendations for their inclusion at the Canadian Memorial Chiropractic College  

UK PubMed Central (United Kingdom)

Since its establishment in 1945, the Canadian Memorial Chiropractic College (CMCC) has predominately adhered to a Diversified model of chiropractic technique in the core curriculum; however, many students...Full Text Available

2000-09-01

180

Mapping strain exerted on blood vessel walls using deuterium double-quantum-filtered MRI  

UK PubMed Central (United Kingdom)

A technique is described for displaying distinct tissue layers of large blood vessel walls as well as measuring their mechanical strain. The technique is based on deuterium double-quantum-filtered (DQF)...Full Text Available

1998-04-14

181

Localizing potentially active post-transcriptional regulations in the Ewing's sarcoma gene regulatory network  

UK PubMed Central (United Kingdom)

BackgroundA wide range of techniques is now available for analyzing regulatory networks. Nonetheless, most of these techniques fail to interpret large-scale transcriptional data...Full Text Available

182

Indications, technique and results of caudal epidural injection for lumbar disc retropulsion.  

UK PubMed Central (United Kingdom)

The indications, contra-indications and technique of caudal epidural injections in the treatment of low back pain and sciatica are described. Of 201 patients treated by epidural injection, about 56%...Full Text Available

1977-01-01

183

In situ nanoindentation in a transmission electron microscope  

Science.gov (United States)

This dissertation presents the development of the novel mechanical testing technique of in situ nanoindentation in a transmission electron microscope (TEM). This technique makes it possible to simultaneously observe and quantify the mechanical behavior of nano-scale volumes of solids.

2002-12-02

184

Experimental Study of a Method of Mechanical Augmentation of Convective Heat Transfer Coefficients in Air.  

Science.gov (United States)

Scraped-surface heat transfer augmentation is proposed as a possible technique for use in improved air-cooling designs. Although it has been in common use with liquids, the technique has apparently never been used with gases. An experimental investigation...

1974-01-01

185

Digital versus conventional templating techniques in preoperative planning for total hip arthroplasty  

UK PubMed Central (United Kingdom)

BackgroundThe purpose of our investigation was to compare a digital templating system to conventional templating techniques when preoperatively planning for total hip arthroplasty.MethodsWe...Full Text Available

2009-02-01

186

Assessment of a bone biopsy technique for measuring tiludronate in horses: A preliminary study  

UK PubMed Central (United Kingdom)

This study assessed the feasibility of measuring tiludronate in horses using a minimally invasive bone biopsy technique. Eight horses were treated with intravenous (IV) tiludronate [1 mg/kg bodyweight...Full Text Available

2011-04-01

187

Adaptive Image Processing A Computational Intelligence Perspective  

CERN Document Server

Adaptive image processing is one of the most important techniques in visual information processing, especially in early vision such as image restoration, filtering, enhancement, and segmentation. This work focuses on applications of advanced CI techniques in image processing applications

2009-01-01

188

A trace gas technique for measuring clothing microclimate air exchange rates  

UK PubMed Central (United Kingdom)

Crockford, G. W., Crowder, M., and Prestidge, S. P. (1972).Brit. J. industr. Med.,29, 378-386. A trace gas technique for measuring clothing microclimate...Full Text Available

1972-10-01

189

A Comparison of Hand-Assisted and Pure Laparoscopic Techniques in Live Donor Nephrectomy  

UK PubMed Central (United Kingdom)

PURPOSETo compare hand-assisted laparoscopic donor nephrectomy and pure laparoscopic live donor nephrectomy techniques in live donor nephrectomy.METHODSIn...Full Text Available

2008-12-01

190

War and Escalation in South Asia  

Science.gov (United States)

... TTP tactics, techniques, and procedures UCP Unified ... be sold or transferred to Pakistan, pursuant to ... substantial amounts of those funds being spent ...

2011-05-13

191

Untitled - NASA Technical Reports Server  

Science.gov (United States)

the techniques employed at present, some of which, like magnetic forming and hotdrape forming, are in experimental stages. Published October 1965. ...

192

The application of advanced techniques for complex focused-ion-beam device modification  

Energy Technology Data Exchange (ETDEWEB)

Advanced techniques for focused-ion-beam (FIB) device modification have been developed for complex, multistep modifications to circuitry on planar chip technology. Applying gas-assisted etching (GAE) techniques for high-aspect-ratio milling and the selective milling of both conductive and insulating films enhances process latitude. Localized ion-beam-induced deposition of an insulating film provides reconstructive capability in previously modified areas. The application of both techniques for complex device modification on VSLI devices fabricated with CMOS process technology is reviewed. (UK).

1996-12-31

193

The Modification of Polymer Surfaces and the Fabrication of ...  

Science.gov (United States)

... spatially defined fashion. Many surface modification techniques require a sequential chemical treatment of the surface.6 ...

1993-06-10

195

Spectroscopy, colorimetry, and biological chemistry in the nineteenth century.  

UK PubMed Central (United Kingdom)

The development of colorimetry and spectroscopy in the nineteenth century is described. An account is given of the application of their techniques to biological chemistry during that period.

1981-03-01

197

SELECTED LISTING OF ECHNOLOGY UTILIZATION PUBLICATIONS  

Science.gov (United States)

as magnetic forming and hot-drape forming. Details about the 25 techniques discussed incorporate the most recent improvements and ...

198

Report on Progress toward Security and Stability in ...  

Science.gov (United States)

... in tactics, techniques, and procedures (TTP), such as ... flow across the Afghanistan-Pakistan border, specifically ... The funds from the NATO ANA Trust ...

2009-10-01

200

Radiation dose in computerized tomography  

International Nuclear Information System (INIS)

Dosimetric studies in 80 patients examined with the tomographic device 'Somatom' are reported. The gonad doses are compared to those of conventional radiographic techniques.

201

ON-LINE MONITORING OF FLUE GAS DESULFURIZATION ...  

Science.gov (United States)

... Title : ON-LINE MONITORING OF FLUE GAS DESULFURIZATION SCRUBBER CORROSION WITH ELECTROCHEMICAL TECHNIQUES. ...

1986-11-01

202

Nuclear structure physics at high resolution  

Energy Technology Data Exchange (ETDEWEB)

Techniques for studying nuclear structure are reviewed. Examples are given of charge density determinations by electron and proton inelastic scattering. (AIP)

1985-04-01

203

Nondestructive Technique Survey for Assessing Integrity of Composite Firing Vessel  

Energy Technology Data Exchange (ETDEWEB)

The repeated use and limited lifetime of a composite tiring vessel compel a need to survey techniques for monitoring the structural integrity of the vessel in order to determine when it should be retired. Various nondestructive techniques were researched and evaluated based on their applicability to the vessel. The methods were visual inspection, liquid penetrant testing, magnetic particle testing, surface mounted strain gauges, thermal inspection, acoustic emission, ultrasonic testing, radiography, eddy current testing, and embedded fiber optic sensors. It was determined that embedded fiber optic sensor is the most promising technique due to their ability to be embedded within layers of composites and their immunity to electromagnetic interference.

2000-08-01

204

NASA Cost Estimating Handbook  

Science.gov (United States)

May 25, 2007 ... The NASA Cost Estimating Handbook brings the fundamental concepts and techniques of cost estimating to NASA personnel in a way that ...

205

Meteorologial Techniques  

Science.gov (United States)

... 2-93 An Atmospheric Particle Emits Electromagnetic ... atmospheric water vapor produces a hydrometeor. ... subject to wind movement (either blowing ...

2003-06-13

206

Machine condition monitoring using neural networks and the likelihood function  

Energy Technology Data Exchange (ETDEWEB)

A model-based technique incorporating neural networks has been developed for process monitoring. The technique is intended for processes where the uncertainty in the reference model is larger than desired but where process measurements providing additional information about the behavior of the system are available. This data is used to reduce the uncertainty of the model. The technique has been implemented in a real-time system for monitoring operational changes of mechanical equipment for use in predictive maintenance applications. Tests on a peristaltic pump were conducted and demonstrate the advantages of the proposed technique.

1997-09-01

207

Intraband Absorptoin of Far-Infrared Light by Electrons in ...  

Science.gov (United States)

... significant change of spontaneous radiation intensity. It is very sensitive technique allowing the observation of small changes of light absorption. ...

1999-06-18

208

HTSC devices fabricated by selective epitaxial growth  

International Nuclear Information System (INIS)

The use of a selective epitaxial growth technique for fabricating YBCO thin-film microstructures is described. No film post-deposition processing is required; hence damage to the structure is minimized. The technique is compatible with a passivation process to protect the structure without exposure to air. The microbridges, Josephson junctions and rf SQUIDs protected by an amorphous YBCO passivation have long lifetime even after severe accelerated aging tests. Rf SQUIDs fabricated by this technique show a significant reduction of low-frequency noise when operating in weak magnetic fields compared with SQUIDs fabricated by the conventional ion beam etching technique. (author)

1999-04-01

209

Femtosecond Photonics: Fundamental Phenomena and ...  

Science.gov (United States)

... concentrated on the construction of switches using fiber ... been chosen for a switch realized in ... of these techniques using acousto-optic modulators or ...

1992-02-10

210

Elemental and stable isotopic approaches for studying the organic and inorganic carbon components in natural samples  

Energy Technology Data Exchange (ETDEWEB)

The carbon cycle is an important part of major biogeochemical cycles. Many techniques may be used to characterize carbon amounts and sources in the environment. Here we first review the most popular techniques for the determination of organic and inorganic carbon concentrations. Decarbonatation techniques are also reviewed in details since it is often an important part of organic carbon analysis. The second part of this paper addresses the use of carbon stable isotopes to characterize organic carbon sources and processes in the environment. An overview of general stable isotopes background and terminology is given as well as the most popular analytical techniques.

2009-01-01

211

Dual-field rotational (DFR) technique for total-skin electron-beam therapy (TSEBT)  

Energy Technology Data Exchange (ETDEWEB)

Comparison of dosimetry measured in a noncylindrical Rando-Alderson phantom by two-field, four-field, and six-field total-skin electron-beam therapy (TSEBT) techniques with our dual-field rotational (DFR) technique reveals a superior dosimetry for the latter. Our technique of dual-field rotational DFR-TSEBT is described in detail, and its advantages and indications for the primary management of cutaneous T-cell lymphoma (CTCL) and Kaposi's sarcoma (KS) are discussed.

1987-08-01

212

Characterization of nuclear fuels by ICP mass-spectrometric techniques  

British Library Electronic Table of Contents (United Kingdom)

Isotopic analyses of radioactive materials such as irradiated nuclear fuel are of major importance for the optimization of the nuclear fuel cycle and for safeguard aspects. Among the mass-spectrometric techniques available, inductively coupled plasma mass spectrometry (ICP-MS) and thermal ionization mass spectrometry are the most frequently applied methods for nuclear applications. Because of the low detection limits, the ability to analyze the isotopic composition of the elements and the applicability of the techniques for measuring stable as well as radioactive nuclides with similar sensitivity, both mass-spectrometric techniques are an excellent amendment to classical radioactivity counting methods. The paper describes selected applications of multicollector ICP-MS in combination with c...

2008-01-01

213

Anesthesia Technique and Outcomes of Endovascular Aneurysm Repair  

British Library Electronic Table of Contents (United Kingdom)

Anesthetic techniques vary widely in the endovascular repair of abdominal aortic aneurysms (EVAR). Previous studies have demonstrated the feasibility of using local anesthesia. However, the ideal anesthetic technique has not been determined. This study examines whether anesthesic technique influences the outcomes of EVAR. Data regarding demographics, risk factors, procedural characteristics, recovery characteristics, treatment complications, acute ( 0.05, ANOVA). From these results we concluded that EVAR with local anesthesia is a safe and efficacious method that may reduce recovery times and postoperative medical morbidity compared to use of genera1 or spinal/epidural anesthesia.

2005-01-01

215

Absorption-Electrochemical Surface Decontamination  

International Science & Technology Center (ISTC)

Development of a Comprehensive Decontamination Database and an Absorption-Electrochemical Metal Surface Decontamination Technique Combining Chemical and Electrochemical Process

217

The research on new production technique of yellow cake  

International Nuclear Information System (INIS)

As a new production technique of yellow cake, resorption with loaded resin-elution with acid ammonium nitrate-precipitation in two steps is studied. The results show that the produced yellow cake by the new production technique has better performance of settlement, filtration and dehydration. Each index of yellow cake accords with the first grade level issued by CNNC without washing, uranium and water content are 70% and 25%, respectively

2001-11-01

218

Remote measurement of methane in coal mines: a review  

Energy Technology Data Exchange (ETDEWEB)

The authors identify a need for a device which can remotely measure methane in coal mines. Similar techniques which have been used to measure atmospheric pollutants are discussed. These techniques include adsorption, Raman scattering and fluorescence. While differential adsorption and Raman scattering techniques have potential there are a number of problems to be resolved before they could be applied effectively. It is felt that an area which may provide suitable technology sometime in the future is in the field of laser sources. 6 refs., 4 tabs.

1987-02-01

219

New techniques of power transformers monitoring and diagnostic; Novas tecnicas de monitoramento e diagnostico de transformadores de potencia  

Energy Technology Data Exchange (ETDEWEB)

This article describes the techniques for monitoring electric power transformers applied by the Light to select and recover critical unities. The plan involved 20 and 40 MV A equipment and, as a reflex of the technique application, presented a substantial failure reduction.

2003-04-01

220

Lidar techniques for search and rescue  

Energy Technology Data Exchange (ETDEWEB)

Four techniques for using LIDAR in Search and Rescue Operations will be discussed. The topic will include laser retroreflection, laser-induced fluorescence in the visible, laser-induced fluorescence during daylight hours, and laser-induced fluorescence in the uv. These techniques use high-repetition rate lasers at a variety of frequencies to induce either fluorescence in dye markers or retroreflection from plastic corner cubes on life preservers and other emergency markers.

1985-01-01

221

Detection of drugs and explosives using neutron computerized tomography and artificial intelligence techniques  

International Nuclear Information System (INIS)

In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.

2010-06-01

222

An interface - marker technique applied to the study of metal silicide growth  

International Nuclear Information System (INIS)

An interface-marker technique has been used to investigate the relative rates of diffusion of Si and of metal atoms during the growth of metal silicide films. The technique enables recognition of a reference plane in thin film diffusion using Rutherford backscattering, while minimizing any perturbation of the diffusion process. Examples are drawn from studies of the growth of silicides of W, Mo, Ta, Nb, Pd and Pt. (orig.).

223

Active RF filter for high voltage transmission lines  

Energy Technology Data Exchange (ETDEWEB)

A new technique is described in this paper for a general active radio frequency (RF) filter trap that can be used for suppressing noise or interference on high voltage (HV) transmission lines. The technique exploits the Miller effect of an RF amplifier in conjunction with a special sensing circuit, and is potentially far more economical to implement than conventional techniques that use passive HV filter components.

1993-07-01

224

Somatic radiation risk in different mammography techniques  

International Nuclear Information System (INIS)

By measuring organ doses with TLD at an Alderson-Rando-phantom it was tested to evaluate the somatic risk for mammographies. Similarly as the genetic risk can be expressed by the genetic significant dose, the somatic risk can be expressed by the somatic significant dose index. The measurement results of the mammography show a large deviation of almost one power of ten with dependence of the chosen technique. In conventional xeroradiography and recording technique with foilless film the somatic radiation risk is the highest. By using amplifying foils in combination with high-sensitive films it is relatively small. Unfortunately the magnitude of the somatic risk in the different mammography techniques is in the ratio reciprocal to the corresponding image quality. At the time being the most favourable technique is mammography with a soft rastering method, although the xeromammography with additional high ...

1981-01-01

225

On-line size and shape measurement techniques for hot steel rolling process; Netsukanatsuen kankyo ni taeru onrain sunpou{center_dot}keijo sokutei gijutsu  

Energy Technology Data Exchange (ETDEWEB)

Recent Kawasaki Steel's development on size and shape measurement techniques for hot steel rolling processes is reviewed. First, a precision enhancement technique for a laser distance meter is described, then its rugged structure necessary for measurement in such tough environment as hot rolling processes is described in detail. A plate length meters and an inter-stand sensors for a hot strip mill are shown as developed size measurement techniques. Furthermore, plate shape meters and laser profile gauges for H-beams are depicted as specific examples of shape measurement techniques. (author)

1999-12-01

226

Novel Techniques and Their Wide Applications to Health Foods, Medical and Agricultural Biotechnology in Relation to Policy Making on Genetically Modified Crops and Foods  

CERN Document Server

Selected applications of novel techniques in Agricultural Biotechnology, Health Food formulations and Medical Biotechnology are being reviewed with the aim of unraveling future developments and policy changes that are likely to open new markets for Biotechnology and prevent the shrinking or closing of existing ones. Amongst the selected novel techniques with applications in both Agricultural and Medical Biotechnology are: immobilized bacterial cells and enzymes, microencapsulation and liposome production, genetic manipulation of microorganisms, development of novel vaccines from plants, epigenomics of mammalian cells and organisms, and biocomputational tools for molecular modeling related to disease and Bioinformatics. Both fundamental and applied aspects of the emerging new techniques are being discussed in relation to their anticipated, marked impact on future markets and present policy changes that are needed for success ...

2004-01-01

227

New anti-jamming technique for GPS and GALILEO receivers using adaptive FADP filter  

British Library Electronic Table of Contents (United Kingdom)

Anti-jamming techniques to improve Global Positioning System (GPS) receivers robustness have been mainly developed in military applications. None of civilian techniques can procure sufficient robustness against occasional or intentional jammers for civil GPS or GALILEO navigation receivers. The amplitude domain processing (ADP) filtering is a technique based upon Capon works and Neyman-Pearson theory. Several experiments concerning the ADP filtering have been considered at the 3DETSNAV division of LACIME laboratory at Ecole de technologie superieure (ETS), which have proved that the technique is reliable in order to eradicate powerful interference present in the spread spectrum signal. However, the results show that the ADP filter has a real limitation when submitted to multiple interferen...

2006-01-01

228

Fluid temperature measurement technique by using Raman scattering  

Energy Technology Data Exchange (ETDEWEB)

Temperature measurement technique by using Raman scattering was developed for the liquid water at temperature of 20 - 90 degree C and atmospheric pressure. Strong relationship between Raman scattering characteristics and liquid temperature change was observed. Various kinds of measurement techniques, such as Peak Intensity, Peak Wavelength, FWHM (Full Width at Half Maximum), PMCR ( Polymer Monomer Concentration RAte), TSIR (Temperature Sensitive Intensity Ratio), IDIA (Integral Difference Intensity Area) were tested. TSIR has the highest accuracy in mean error or 0.1 deg C and standard deviation of 0.1248 deg C. This report is one of the results in developing process of Raman temperature measurement technique. Next research step is to develop Raman temperature measurement technique at the high temperature and high pressure conditions in single or two phase flows. (author). 13 refs., 3 tabs., 38 figs.

1999-06-01

229

Feasibility of using Gaspils and other methods of remotely measuring methane in coal mines and preparation of a conceptual design for a suitable instrument (UP-M-513) final report  

Energy Technology Data Exchange (ETDEWEB)

The use of differential absorption and Raman scattering techniques for the remote sensing of methane in underground coal mines is examined. An analysis of the differential absorption technique showed that non-range resolved systems were incapable of achieving the desired concentration and range specifications and therefore were unsuitable for use in underground coal mines. The Raman scattering technique proved quite successful and a conceptual design which uses the technique is presented. The availability of suitable UV source is critical to the success of the technique however, and to date there is nothing which meets size and portability requirements for a system of this type. Recommendations for further study are included. 19 refs.

1986-04-01

230

Cost minimization analysis for combinations of sampling techniques in bronchoscopy of endobronchial lesions  

British Library Electronic Table of Contents (United Kingdom)

SummaryBackground The choice of sampling techniques in bronchoscopy with sampling from a visible lesion will depend on the expected diagnostic yields and the costs of the sampling techniques. Aims The aim of this study was to determine the most economical combination of sampling techniques when approaching endobronchial visible lesions. Methods A cost minimization analysis was performed. All bronchoscopies from 2003 and 2004 at Haukeland university hospital, Bergen, Norway, were reviewed retrospectively for diagnostic yields. 162 patients with endobronchial disease were included. Potential sampling techniques used were biopsy, brushing, endobronchial needle aspiration (EBNA) and washings. Costs were estimated based on registration of equipment costs and personnel costs. Sensitivity analyse...

2009-01-01

231

Applications of the phased array technique; Anwendungsmoeglichkeiten der Gruppenstrahlertechnik  

Energy Technology Data Exchange (ETDEWEB)

The application of the phased array technique was limited to heavy and thick wall components as present in the nuclear industry. With the improvement of the equipment and probes other application areas are now open for the phased array technique, e.g. the inspection of the turbine blade root, weld inspection in a wall thickness range between 12 and 40 mm, inspection of aircraft components, inspection of spot welds or inspection of concretes. The aim of the use of phased array techniques has not been changed related to the first applications, i.e. the adaptation of the sound beam to the geometry by steering the angel of incidence or the skewing angle as well as the focussing of sound fields. Due to the fact, that the new applications of the phased array techniques in some cases don't leave the laboratories for the time being, the examples of this contribution will focus applications with ...

1999-07-01

232

Innovative coke-oven repair techniques  

Energy Technology Data Exchange (ETDEWEB)

Certain innovative coke-oven repair techniques are reviewed that represent an engineered approach to a successful rehabilitation of all types of coke-oven batteries. These techniques have been developed during the last 10 years and experience gained on a number of repair projects has shown that these techniques operate as a cohesive and comprehensive method of end flue and through-wall repairs to gain additional years of operating life to coke-oven batteries. Extended operations approaching 10 to 15 additional years of service at lower costs than a pad-up rebuild and, while meeting the environmental emission regulations, are attainable using the techniques of: Proper tie-in joint preparation; Improved bricking up methodology; Preheating refractory during bricking up; Installation of spring-loaded bracing system; and installation of flexible coke-oven doors. Repair methods that do not incorporate the ...

1995-10-01

233

Fluid flow visualization with neutron radiography. [Using collimated beam of neutrons  

Energy Technology Data Exchange (ETDEWEB)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1991-01-01

234

Fluid flow visualization with neutron radiography  

International Nuclear Information System (INIS)

A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in various flow configurations. Imaging ...

1764-01-01

235

In vitro and in vivo study of {sup 99m}Tc-MIBI encapsulated in PEG-liposomes: a promising radiotracer for tumour imaging  

Energy Technology Data Exchange (ETDEWEB)

Encapsulation of technetium-99m sestamibi ({sup 99m}Tc-MIBI) in polyethyleneglycol-liposomes ({sup 99m}Tc-MIBI-PEG-liposomes) could extend the duration of its circulation in blood and alter its biodistribution, enabling its concentration in tumours to be increased. An original method to encapsulate {sup 99m}Tc-MIBI in PEG-liposomes is described. The {sup 99m}Tc-MIBI-PEG-liposomes were compared with free {sup 99m}Tc-MIBI with respect to (a) tumour availability (b) ability to distinguish between chemotherapy-sensitive and -resistant cells and (c) uptake ratio in tumour imaging. PEG-liposomal systems composed of distearoylphosphatidylcholine/cholesterol/PEG{sub 2000}-distearoyl phosphatidylethanolamine and lissamine-rhodamine B-labelled liposomes were used. The encapsulation of {sup 99m}Tc-MIBI in liposomes was achieved using the K{sup +} diffusion potential method. We compared the uptake of free versus encapsulated {sup 99m}Tc-MIBI by sensitive and resistant erythroleukaemia (K562) and ...

2003-04-01

236

Incorporating organizational factors into Probabilistic Risk Assessment (PRA) of complex socio-technical systems: A hybrid technique formalization  

Energy Technology Data Exchange (ETDEWEB)

This paper is a result of a research with the primary purpose of extending Probabilistic Risk Assessment (PRA) modeling frameworks to include the effects of organizational factors as the deeper, more fundamental causes of accidents and incidents. There have been significant improvements in the sophistication of quantitative methods of safety and risk assessment, but the progress on techniques most suitable for organizational safety risk frameworks has been limited. The focus of this paper is on the choice of 'representational schemes' and 'techniques.' A methodology for selecting appropriate candidate techniques and their integration in the form of a 'hybrid' approach is proposed. Then an example is given through an integration of System Dynamics (SD), Bayesian Belief Network (BBN), Event Sequence Diagram (ESD), and Fault Tree (FT) in order to demonstrate the feasibility ...

2009-05-15

237

Distortion-invariant color pattern recognition using multiple phase-shifted-reference-based joint transform correlation incorporating synthetic discriminant function  

Science.gov (United States)

This paper proposes a new pattern recognition system employing optical joint transform correlation (JTC) technique which offers a great number of advantages over similar digital techniques, including very fast operation, simple architecture and capability of updating the reference image in real time. The proposed JTC technique incorporates a synthetic discriminant function (SDF) of the target image estimated from different training images to make the pattern recognition performance invariant to noise and distortion. It then involves four different phase-shifted versions of the same target SDF reference image, which are individually joint transform correlated with the given input scene. When the correlation signals are combined, it produces a single cross-correlation peak corresponding to each potential target present in the given input scene. The proposed technique also includes a fringe-adjusted filter ...

2011-04-01

238

Dating techniques in fault investigations  

International Nuclear Information System (INIS)

Determining the time of most recent fault movement is an important part of assessing a possible site for a nuclear power plant. The purpose of this paper is not to present research information but to provide a practical guide to some of the dating techniques available to the engineering geologist working on nuclear power plant siting. Emphasis is placed on the practical aspects, such as usable minerals, conditions necessary for them to yield correct dates, degree of accuracy, sample collection, sample size, and sample packaging. In this paper, the usual geologic field techniques are taken for granted (such as those used in stratigraphy, paleontology, and structural analysis) for assessing fault history. Laboratory techniques used in conjunction with or supplemental to field methods are discussed. The specific radiometric methods discussed are "1"4C(carbon-14), fission track, K-Ar (potassium-argon), thermoluminescense, Rb-Sr ...

239

Accelerated stability test techniques for middle distillate fuels  

Energy Technology Data Exchange (ETDEWEB)

Improved test techniques are needed for evaluating the inherent stability of middle distillate fuels both in surveillance and in procurement activities. A project was initiated to define and evaluate the contributing conditions leading to the formation of deleterious products in accelerated aging tests of middle distillate fuels and to relate these results to an experimental definition of more repeatable/reliable middle distillate fuel stability test technique(s). A literature search was conducted to provide a list of stability test techniques and their interpretations which could be used in a correlative middle distillate fuel stability test program. For this program, seven accelerated stability tests were chosen and evaluated using a set of six test fuels. The test techniques were selected to represent a wide variety of test conditions, including temperature, aging time, and oxygen availability. These ...

1981-01-01

240

The use of Radioactive labeling in hemoglobin identification  

International Nuclear Information System (INIS)

The basic approach to radioactive labeling techniques in hemoglobin identification consists of mixing 14C labeled normal carrier globin with 3H labeled unknown globin and carrying out the subsequent separations and purifications looking at the distribution of 3H and 14C radioactivity. This technique was devised to ascertain the amino acid substitution in Hb Indianapolis and was instrumental in solving the structure of Hb Vicksburg. It was also useful in determining the purity of gamma-chains from cultures of human and baboon erythroid progenitors. Another use of this technique would be in identifying aberrant peaks of radioactivity in chain separation chromatograms, such as ''pre-peaks''.

241

The crack of harden cement paste observed with multi-technique  

British Library Electronic Table of Contents (United Kingdom)

The shrinkage of the cement paste with low water-cement ratio at different relative humidity was observed and analyzed with ESEM and deformation map technique. The crack morphology was observed with different magnification with SEM and FESEM, and the formation of the crack was observed with AFM between two C-S-H nano particles. The observation by multi technique at multi scale indicated that the shrinkage was increase with the decrease of the humidity due to the increase of the pressure of the capillary pressure, the morphology of the crack in smaller scale was similar to that in the bigger scale, the smaller crack distributed in the latticework of the bigger ones, and the crack propagated along the gap between two nano particles of C-S-H with weaker bonding.

2010-01-01

242

State-of-the-art technique for power system stabilizer tuning  

Energy Technology Data Exchange (ETDEWEB)

Power System Stabilizers (PSS) have broad application throughout the world. PSS application requires careful tuning which is usually accomplished in the field with the generator and power system in an abnormal condition. Recently developed equipment which combines fast Fourier transform capability with digital computer technique provides a means of PSS tuning which is faster and more accurate than was previously obtainable. This paper describes a PSS tuning test conducted using the new technique. The advantages will be apparent to the reader. The described test is very poignant as evidenced by two unexpected occurrences of instability.

1983-03-01

243

Remote on-board coal quality sensing techniques in coal cutting and handling systems  

Energy Technology Data Exchange (ETDEWEB)

A review of the literature was undertaken to determine the potential for development of instrumentation for on-board remote sensing of coal quality. This review report acts as an inventory of commercially available techniques being tested or under development, particularly in the areas of the cutting horizon measurement methods associated with longwall mining equipment and coal/waste monitoring techniques in coal handling systems. While technology is available which can discriminate rocks from coal on a conveyor belt, the literature indicates that this hardware has yet to be adapted to continuous surface mining machines. 23 refs., 18 figs.

1987-09-01

244

Proceedings of the third annual better reclamation with trees conference  

Energy Technology Data Exchange (ETDEWEB)

The twenty-three papers presented at this conference discussed requirements of land reclamation under the Federal surface mining regulations, evaluation techniques for assessing reclaimed land, spoil bank chemistry and its change with time, establishment techniques (vegetative propagation, containerized seedlings, nurse vegetation, nitrogen-fixing tree species, direct seeding, and general cultivation techniques), and results from early land reclamation trials. Twenty-two papers have been abstracted separately. 291 references, 16 figures, 80 tables.

1983-01-01

245

Leachability of neutron irradiated fly ash  

Science.gov (United States)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-11-01

246

Leachability of neutron irradiated fly ash  

International Nuclear Information System (INIS)

Leachability of neutron irradiated fly ash is investigated as a method for studying element leaching properties of this material with various leaching media. Quantitative aspects of radiation damage are shown to be minor. Therefore, the technique should be applicable for this purpose. It is further shown that this technique affords significant advantages over the conventional post-leaching analysis with respect to utilization of natural solutions for the investigation of fly ash leachability. However, for a few elements such as Pb, Bi, V, and Al, the various nuclear parameters involved invalidate applicability of the present technique.

1977-01-01

247

Interpretation of EXAFS data from laser shock compressed plasmas  

Energy Technology Data Exchange (ETDEWEB)

Measurements on laser shock compressed aluminium using the EXAFS (Extended X-ray Absorption Fine Structure) technique on the Al K-edge are described. Two methods of analysis of this data were used for the determination of density: the standard EXAFS technique using Fourier transforms and curve fitting, and a method based on a bandstructure calculation of the absorption spectra as a function of compression. These two techniques give results which are in fairly good agreement with each other and also with a hydrodynamic simulation of the experiment. The ion correlation parameter is estimated and shows that two-sided laser irradiation of aluminium foils produces a dense plasma which is strongly coupled. (author).

1989-01-01

248

Interim explosives detection alternatives  

Energy Technology Data Exchange (ETDEWEB)

There is a general concern with insiders smuggling bomb quantities of explosives into sensitive facilities such as nuclear facilities. At this time, there is no single explosives detection device that is suitable for monitoring personnel and their packages for explosives in an operational facility environment. However, there are techniques combining available commercial technologies with procedures and threat analysis that can significantly increase the insiders risk and reduce the population of adversaries. This paper describes the available applicable explosives detection technologies and discusses the techniques that could be implemented on an interim basis. It is important that these techniques be considered, so that some interim level of security against the explosives threat can be established until more sophisticated equipment that is under development becomes available.

1991-01-01

249

Gases in insulating oil - analysis of dissolved gases using a portable chromatograph  

Energy Technology Data Exchange (ETDEWEB)

New technological advances make it possible to perform on site gas-in-oil analysis quickly and efficiently. Gas-in-oil analysis is crucial in assessing the status of oil-filled electrical equipment. The new technique is used for extracting and measuring gases dissolved in electrical insulating oil. On-site sampling requires the use of a specially designed 100 ml capacity syringe. Extraction of the dissolved gases is made with a precise ratio of oil to air. A comparison was made between the analysis of the on-site and the laboratory techniques. Results showed that the detection limits of the on-site technique were comparable to those obtained by laboratory methods.

1996-07-01

250

Direct dark matter identification with a hybrid detection technique  

CERN Document Server

In the quest to understand the ultimate nature of WIMPs, we propose the use of a hybrid detection technique: cylinders filled with liquefied noble gasses, acting as targets, are immersed inside a tank of Gd-doped ultra-pure water that provides an active and efficient veto against neutrons. The evaluation of the background rejection capabilities and physics potential of this instrument have been carried out through a full GEANT4 simulation, assuming the detector will be located at the Canfranc underground laboratory (in the Spanish Pyrenees). Our results compare very favourably with existing or planned experiments in the field. This technique is scalable and will allow to reach target masses of few tonnes in the next future.

2008-01-01

251

Design of a Fractional Order PID Controller Using Particle Swarm Optimization Technique  

CERN Document Server

Particle Swarm Optimization technique offers optimal or suboptimal solution to multidimensional rough objective functions. In this paper, this optimization technique is used for designing fractional order PID controllers that give better performance than their integer order counterparts. Controller synthesis is based on required peak overshoot and rise time specifications. The characteristic equation is minimized to obtain an optimum set of controller parameters. Results show that this design method can effectively tune the parameters of the fractional order controller.

2008-01-01

252

An application of the analysis of variance of measures repeated in an experiment with heavy metals  

International Nuclear Information System (INIS)

A revision of some basic concepts related to the analysis of variance of repeated measures is presented within an ecological context topics such as the types of experiments in which the technique is applicable, the hypotheses of interest, and its preference over other traditional techniques such as regression and conventional analysis of variance, are discussed. As an example, the technique was successfully applied to an experiment carried out at Cienaga Grande de Santa Marta, Colombia, in which the concentration of cadmium #mu#g/g in leaves of the black mangrove Avicennia germinans was measured in several monitoring stations and throughout several sampling intervals representing seasons.

1997-11-01

253

A new technique for production of yellow cake with double precipitation  

International Nuclear Information System (INIS)

The author presents a new technique for production of yellow cake with double precipitation, thus solving a series of problems for precipitating uranium with traditional double precipitation. The new technique can not only remove ferric ions and sulfate radicals but also make solid-liquid separation easy, utilize effectively the sulfuric acid produced in ferric ions precipitation process, and increase uranium concentration of leaching liquor. To take it as producing yellow cake will save investment, simplify operation, and cut down the consumption of raw materials and energies. It is more competitive than ion-exchange or solvent extraction in the process of extracting-purifying and preparing yellow cake.

1997-01-01

254

Use of neural network techniques to identify cosmic ray electrons and positrons during the 1993 balloon flight of the NMSU/Wizard-TS93 instrument  

Energy Technology Data Exchange (ETDEWEB)

The detectors used in the TS93 balloon flight produced a large volume of information for each cosmic ray trigger. Some of the data was visual in nature, other portions contained energy deposition and timing information. The data sets are amenable to conventional analysis techniques but there is no assurance that conventional techniques make full use of subtle correlations and relations amongst the detector responses. With the advent of neural network technologies, particularly adept at classification of complex phenomena, it would seem appropriate to explore the utility of neural network techniques to classify particles observed with the instruments. In this paper neural network based methodology for signal/background discrimination in a cosmic ray space experiment is discussed. Results are presented for electron and positron classification in the TS93 flight data set and will be compared to conventional analyses.

1995-09-01

257

The concept of power correction techniques and its use in the reactor regulation and protection systems in Indian PHWRs  

International Nuclear Information System (INIS)

Reactor Power Measurement is an essential part of the Reactor Power Control Loop in PHWRs. None of the available power measuring sensor offers characteristics which allow their direct use in the Reactor Power Control Loop. Thermal power, which is considered as relatively accurate, suffers from measurement delays and is used only as reference. Neutronic power sensors like Ion Chambers and Self Powered Neutron Detectors (SPNDs) which sense instantaneous power suffer from inaccuracies. A technique is required which makes use of both types-reference power and instantaneous power to extract real power information from the signals. This paper describes techniques to calibrate (correct) neutronic power that with the thermal reference power signals. The paper also brings out limitation of the calibration technique. (author)

2010-02-01

258

The Financial War on Terrorism: Grading US Strategy for ...  

Science.gov (United States)

... that operated in Pakistan, Dubai, and throughout the Middle East ... identifies 'funds' as one of eight major terrorist ... techniques, and procedures (TTP). ...

2006-04-15

259

The Effects of Long Term Storage on Special Purpose Lead ...  

Science.gov (United States)

... Special Purpse Lead Azide Lot #I3A-4-62 ... Standard X-ray techniques are not sufficiently sensitive ... the National Bureau of Standards, and examined ...

1972-10-01

260

The 2011 AusGO/AAO Observational Techniques Workshop  

Science.gov (United States)

Applying for AAO scheduled time Applying for AAT service time Applying for Gemini Time Travel and Accommodation AAT Schedule UKST Schedule Instrument capabilities and...

2011-10-15

261

TOPIC O4 Navigation - NASA's SBIR & STTR Programs  

Science.gov (United States)

Applications of cutting-edge estimation techniques, such as, but not limited to, sigma-point and particle filters, to spaceflight navigation problems. ...

262

TIPS Creation in a Patient with Situs Inversus Totalis  

International Nuclear Information System (INIS)

We describe the successful creation of a transjugular intrahepatic portosystemic shunt (TIPS) in a patient with complete situs inversus using a simple modification of the standard TIPS technique.

2002-10-01

265

Structure and morphology changes during nylon 66 fiber deformation via synchrotron x-ray scattering techniques  

Energy Technology Data Exchange (ETDEWEB)

Morphological and structural changes of nylon 66 were evaluated during a continuous heat-draw process. Results are discussed.

1996-12-31

266

Separation of oligo-RNA by reverse-phase HPLC.  

UK PubMed Central (United Kingdom)

A rapid and highly reproducible chromatographic technique has been developed for analysis and purification of complex mixtures of oligoribonucleotides. The method utilizes a column of microparticulate...Full Text Available

1979-10-25

267

STUDY OF METEOR WIND MEASUREMENT TECHNIQUES. ...  

Science.gov (United States)

... of a secondary standard (VCO) locally available. ... phase of the local secondary standards to the 10-min average of the phase of ... I3a - - \\.-e-~--. ...

1970-02-01

268

Review of passive heat transfer augmentation techniques  

Energy Technology Data Exchange (ETDEWEB)

Heat transfer augmentation techniques (passive, active or a combination of passive and active methods) are commonly used in areas such as process industries, heating and cooling in evaporators, thermal power plants, air- conditioning equipment, refrigerators, radiators for space vehicles, automobiles, etc. Passive techniques, where inserts are used in the flow passage to augment the heat transfer rate, are advantageous compared with active techniques, because the insert manufacturing process is simple and these techniques can be easily employed in an existing heat exchanger. In design of compact heat exchangers, passive techniques of heat transfer augmentation can play an important role if a proper passive insert configuration can be selected according to the heat exchanger working condition (both flow and heat transfer conditions). In the past decade, several studies on the passive ...

2004-12-01

269

Relationship of Optical Coating on Thermal Radiation ...  

Science.gov (United States)

drical Enclosures Using a Numerical Ray Tracing Technique. NASA. TM-I02527, 1990 . Buckley, H.: Radiation from the Interior of a Reflecting Cylinder. Philos. ...

270

Radionuclide X-ray fluorescence analysis. 2: Detection of the X-ray fluorescence radiation excited by radionuclide radiation  

Science.gov (United States)

This investigation describes the technique for the detection of the X-ray fluorescent radiation

1972-01-01

271

Quantitative morphology and water distribution of bronchial biopsy samples.  

UK PubMed Central (United Kingdom)

BACKGROUND: An approach to the study of the pharmacokinetics of drugs in the lung is to measure their concentrations in bronchial biopsy specimens. The main criticism of this technique is that bronchial...Full Text Available

1992-07-01

272

Quantitation of Antibiotics by High-Pressure Liquid Chromatography: Cephalothin  

UK PubMed Central (United Kingdom)

A technique for quantitative determination of cephalothin and desacetylcephalothin in serum using a method based on high-pressure liquid chromatography is described. Both compounds were quantitatively...Full Text Available

1978-02-01

274

Preconcentration and decontamination in radioanalysis  

International Nuclear Information System (INIS)

The scope of radioanalysis can be enlarged substantially by preconcentration. The minimal concentration factor required depends on the concentration to be determined, the limit of determination of the analytical technique and the maximal acceptable sample-weight. Simultaneously, the preconcentration step may cause a decontamination. In post-irradiation chemistry this is usually the crucial parameter. The present paper proposes the classification of (pre-) concentration techniques by the relation between the concentration-factor X and the decontamination-factor Y. In addition, three other criteria here are used to judge the applicability in combination with the analytical technique chosen. They stem from the minimal representative and the maximal acceptable sample-weights and the maximal acceptable dose-rate. The features of a particular combination of (pre-) concentration and analytical technique can be ...

275

Potassium Transport in Corn Roots 1  

UK PubMed Central (United Kingdom)

The relative transport capabilities of the cells of the root periphery and cortex were investigated using a variety of experimental techniques. Brief (30 seconds to 1 minute) exposures with the penetrating...Full Text Available

1983-10-01

276

Periodic perturbations producing phase-locked fluctuations in visual perception  

UK PubMed Central (United Kingdom)

This paper describes a novel psychophysical and analytical technique, called periodic perturbation, for creating and characterizing perceptual waves associated with transitions in visibility...Full Text Available

277

PRIOR CAMPAIGNS - NASA - Microgravity University - Reduced Gravity ...  

Science.gov (United States)

The goal of this experiment is to evaluate the usefulness of existing normal gravity two-phase flow heat transfer augmentation techniques under microgravity ...

278

Optical Spectroscopy for Noninvasive Monitoring of Stem Cell Differentiation  

UK PubMed Central (United Kingdom)

There is a requirement for a noninvasive technique to monitor stem cell differentiation. Several candidates based on optical spectroscopy are discussed in this review: Fourier transform infrared (FTIR)...Full Text Available

2010-01-01

279

Optical Diffraction Studies of Muscle Fibers  

UK PubMed Central (United Kingdom)

A new technique to monitor light diffraction patterns electrically is applied to frog semitendinosus muscle fibers at various levels of stretch. The intensity of the diffraction lines, sarcomere length...Full Text Available

1973-09-01

280

New equipment recharges Oldham batteries  

Energy Technology Data Exchange (ETDEWEB)

The battery manufacturing industry has not been immune to the impact of new technologies. How one company is adapting production techniques to meet the demand for better products is discussed.

1982-09-24

281

New and old Sn isomers produced in heavy-ion collisions  

International Nuclear Information System (INIS)

The energy level schemes of tin isotopes produced in the heavy ion reactions are presented. The using of #gamma# spectroscopy technique is also described. 4 refs, 12 figs.

1991-12-01

282

NASA TECH BRIEF - NASA Technical Report Server (NTRS)  

Science.gov (United States)

(NaMBT) inhibitor in ethylene glycol-water solutions. The improved method must be faster and more accur- ate than wet chemical techniques. ...

283

Molecular spectroscopy and planetary atmospheres  

Energy Technology Data Exchange (ETDEWEB)

With the improvements accomplished during the past 15 years in detection techniques and instrumentation and with the opening of space exploration, molecular spectroscopy has become a very efficient way to probe planetary atmospheres.

1984-01-01

284

Minimally Invasive Orthopedic Surgery: Arthroscopy  

UK PubMed Central (United Kingdom)

Arthroscopy, a minimally invasive alternative to standard open surgical techniques and now the most commonly performed orthopedic surgical procedure, was one of the greatest advances in orthopedic surgery...Full Text Available

2000-07-01

285

Medulloblastoma: Are We Overtreating?  

UK PubMed Central (United Kingdom)

Modern advances in the concept and the techniques of megavoltage radiation therapy have revolutionized the treatment of medulloblastoma. Five-year survivals of 50 to 70 percent are achieved by craniospinalaxis...Full Text Available

1985-02-01

286

Medical problems affecting musicians.  

UK PubMed Central (United Kingdom)

The physical demands of performing on musical instruments can cause pain, sensory loss, and lack of coordination. Five cases illustrate common problems. Knowledge of the interaction between the technique...Full Text Available

1995-12-01

287

Measuring and Reporting Fuel Economy of Plug-In Hybrid Electric Vehicles  

Energy Technology Data Exchange (ETDEWEB)

This paper reviews techniques used to characterize plug-in hybrid electric vehicle fuel economy, discussing their merits, limitations, and best uses.

2006-11-01

288

Luminescence dating  

International Nuclear Information System (INIS)

The luminescence techniques have evolved over the last 40 years to a powerful dating instrument in archaeology and geoscience. Depending on how the luminescence is stimulated, one distinguishes the phenomena of thermoluminescence (TL), optically stimulated luminescence (OSL) and infrared stimulated luminescence (IRSL). Each of these phenomena has its specific potential for dating various archaeological materals in the time range from medieval back to palaeolithic periods, or, speaking in geological terms, for dating of Holocene and late Pleistocene objects. The OSL and IRSL techniques are sometimes treated together as 'optical dating'. The luminescence techniques differ from other major dating techniques, such as 14C, essentially by their applicability to inorganic materials, their wide age-range from about 100 years to more than 100,000 years and the kind of datable events which are the last exposure ...

289

Jupiter Solar Mission Alternative Feasibility Study  

Science.gov (United States)

Because of its direct energy conversion techniques, AMTEC is the front runner today. However, because these systems are now only in the preliminary design ...

290

Ionospheric Modeling and Propagation Analysis.  

Science.gov (United States)

... these features and yields results which are two orders of magnitude faster than those available using conventional numerical ray tracing techniques ...

1980-04-01

291

Indirect resin composites  

UK PubMed Central (United Kingdom)

Aesthetic dentistry continues to evolve through innovations in bonding agents, restorative materials, and conservative preparation techniques. The use of direct composite restoration in posterior teeth...Full Text Available

2010-10-01

292

In-situ micro-FTIR study of thermal changes of organics in Tagish ...  

Science.gov (United States)

FT-IR spectroscopic studies of major organic matter in carbonaceous chondrites using microscopic technique and comparison with terrestrial kerogen. ...

293

High Peak Power, High PRF Laser System.  

Science.gov (United States)

... A technique of the prior art uses an acousto-optic Q-switch which can ... Another approach uses electro-optic Q-switches in a pseudo cavity dumping ...

1980-10-27

294

Health and environmental chemistry: Analytical techniques, data management, and quality assurance. Volume 1, Manual  

Energy Technology Data Exchange (ETDEWEB)

Analytical procedures are described for the determination of organic compounds, metals and radioisotopes in environmental materials, human tissues, urine, feces, and waste water.

1993-11-01

295

Gravity Gradiometer Survey and Real Time Techniques for ...  

Science.gov (United States)

... 4 II. INERTIAL NAVIGATION ERROR EQUATIONS ..... 5 ... 4- Page 20. Chapter II INERTIAL NAVIGATION ERROR EQUATIONS ...

1981-12-01

296

Genetics, Genomics, and Molecular Biology  

Science.gov (United States)

Genetics, Genomics, and Molecular Biology USGS scientists develop and integrate new genetic and molecular techniques into systematic analyses to describe individuals and populations of fish .....

297

GERT" GRAPHICAL EVALUATION AND REVIEW TECHNIQUE  

Science.gov (United States)

of a stochastic network can be a. PERT-type network. After the terminal countdown, ...... pictorial representation of a single channel queueing system ...

298

Fixation Techniques for Split Anterior Tibialis Transfer in Spastic Equinovarus Feet  

British Library Electronic Table of Contents (United Kingdom)

Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of equinovarus in 47 patients with hemiplegic traumatic brain injury and specifically studied differences in outcomes with two tendon fixation techniques. Seventeen patients constituting Group I underwent fixation with one technique and 30 constituting Group II had another technique. Patients in both groups had appropriate procedures based on dynamic electromyography and gait analyses. Both groups were demographically comparable. All 47 feet were corrected to plantigrade position. Thirty-six of 47 patients became brace-free at final followup. There was a notable decrease in the use of ambulatory a...

2008-01-01

299

Fast-Burning Rate/High Slope Propellant Technology ...  

Science.gov (United States)

... technique aBF n-Butyiferrocene P-33 Thermal carbon black PAP Porous Amnmonium Perchlorate Plastinox 711 Antioxidant ...

1971-04-01

300

Factors Influencing the Effectiveness of Swimming Pool Bactericides  

UK PubMed Central (United Kingdom)

Techniques for culturing, harvesting, and testing bacteria to evaluate bactericidal chemicals for swimming pools are described. Concentrations of 25, 50, and 100 mg of the chlorine stabilizer cyanuric...Full Text Available

1967-05-01

301

Exploding Foil Techniques  

Science.gov (United States)

... was obtained from NASA on a loan basis. This unit was built for use in magnetic forming 'I3 Page 13. IA I u U OI 7 - 4 ,o u ...

1970-04-01

302

Development of New Ground Inspection Techniques for the ...  

Science.gov (United States)

Integration of Eddy Current probes with MAUS scanning system has been demonstrated to produce scan rates of 36 sqft/hour. System will be designed to ...

303

Decade of Achievement - Educational Leadership in Mathematics, Science and Engineering  

Science.gov (United States)

... education. It has fostered development of materials and techniques with the success of all, rather ... with Foundation staff to produce exemplary materials and models to help the nation attain its ...

304

Computed tomography of head in Clinic Pediatrics  

Energy Technology Data Exchange (ETDEWEB)

138 unselected head tomographies of children by computer are reported and analysed. The major aspect stressed by the authors is the excellent precision of this radiological technique.

1982-02-01

305

Coke Making in the Beehive Oven.  

Science.gov (United States)

Documents an early American industrial process of making blast furnace coke using techniques and equipment from the 19th century. Photographed at Bretz, WV.

1994-01-01

306

Clinical spectrum  

Energy Technology Data Exchange (ETDEWEB)

A tunable diode laser is used to obtain infrared spectra of carbon dioxide in biological materials. The spectral resolution is sufficient to readily distinguish differing isotopic species. The technique may prove useful in clinical tests.

1987-11-01

307

Bicarbonate kinetics and predicted energy expenditure in critically ill children2  

UK PubMed Central (United Kingdom)

Background:To determine nutrient requirements by the carbon oxidation techniques, it is necessary to know the fraction of carbon dioxide produced during the oxidative...Full Text Available

2008-08-01

308

Automated NDT for large diameter tubular products  

International Nuclear Information System (INIS)

Ultrasonic and eddy-current techniques are used to automatically examine large diameter tubular products during their production for defective areas and out-of-tolerance conditions.

1976-09-06

310

Analysis of the archaeological pieces with the PIXE technique; Analisis de piezas arqueologicas con la tecnica PIXE  

Energy Technology Data Exchange (ETDEWEB)

The handling of physical-nuclear techniques for the analysis of archaeological pieces it was carried out by first time in 1956 by the doctors Oppenheimer and Dodsom (in the United States); who wrote about the wide utilities of the neutron activation analysis (NAA), this technique requires of a nuclear reactor that could be considered like one a factory of thermal neutrons necessary to carry out this analysis. The first experiments in that were applied the NAA were on ceramic coming from the Mediterranean, in those that the relationships of the elements of sodium and manganese were determined to know their elementary composition and to identify the origin of their manufacture. Later on other study techniques were applied in archaeological materials, as the X-ray fluorescence, Moessbauer spectroscopy, scanning electron microscopy, PIXE analysis (particle induced x-ray emission), among other, this last is the matter that we ...

2005-07-01

311

An Evaluation of a Technique for Using the Combat Training ...  

Science.gov (United States)

... proficiency, most Army personnel must shoot to the same standards required of ... Wild- flecken was to provide this standard range, but its scores ... I3a I] ...

1979-05-01

312

Adaptive Management of Liver Cancer Radiotherapy  

British Library Electronic Table of Contents (United Kingdom)

Adaptive radiation therapy for liver cancer has the potential to reduce normal tissue complications and enable dose escalation, allowing the potential for tumor control in this challenging site. Using adaptive techniques to tailor treatment margins to reflect patient-specific breathing motions and image-guidance techniques can reduce the high dose delivered to surrounding normal tissues while ensuring that the prescription dose is delivered to the tumor. Several treatment planning and delivery techniques have been developed for use in the liver, including a margin to encompass the full breathing motion, mean position techniques, which evaluate the probability of tumor location during breathing, breath hold, gating, and tracking. Patient selection, clinical workflow, and quality assurance m...

2010-01-01

314

AGARD Flight Test Techniques Series. Volume 1. Calibration ...  

Science.gov (United States)

... of "position error" in the AGARD Multilingual Aeronautical ... when it cones into the aircraft flow field it ... on actual bank angle and separation, may be - ...

1983-09-01

315

A new adaptive power system stabilizer using a Lyapunov design technique  

Energy Technology Data Exchange (ETDEWEB)

A technique for designing an adaptive power system stabilizer is presented which improves the dynamic stability of power systems by effectively increasing the damping torque of the synchronous generator in the system. The proposed adaptive stabilizer is optimal in the sense of minimizing a specified performance condition. A characteristic feature of using a Lyapunov techniques is that it leads to stable adaptation loops. The dynamic responses following a step disturbance by digital simulations are obtained by means of three types of stabilizers: the conventional power system stabilizer, a frequency-response-based optimal adaptive stabilizer and the proposed Lyapunov stabilizer. Simulation results on a typical single-machine/infinite-bus system illustrate the superiority of the proposed technique. (author).

1990-04-01

316

A Preliminary Study on Dressing Patterns and Incidence of Candidiasis  

UK PubMed Central (United Kingdom)

The incidence of candidiasis in two groups of voluntary participants wearing tight and loose fitted dresses was investigated by both microscopic and cultural techniques for a period of two months....Full Text Available

1982-02-01

317

/ /tLc - NASA Technical Reports Server  

Science.gov (United States)

Inertial navigation error propagation. Hypersonic entry guidance techniques. Ablation effects on hypersonic aero-. Primary navigation and guidance ...

318

 

UK PubMed Central (United Kingdom)

Enteropathogenic E. coli were sought routinely by the fluorescent antibody technique, using monovalent and polyvalent conjugates (rhodamine sulfonyl· chloride, fluorescein and rhodamine isothiocyanate)....Full Text Available

1962-11-03

319

Wind ripple analysis  

Science.gov (United States)

Efficient and economical utilization of wind power will require the ability to measure and ultimately predict the effects fluctuations in the incident wind will have on a wind turbine. In order to quantitatively assesss these effects, experimental techniques have been developed which allow analysis of full-scale performance of wind turbines with particular emphasis on the effects caused by turbulence in the incident wind. Examples of these techniques are presented using data from the DOE/Sandia Vertical Axis Wind Turbine (VAWT) program.

1981-01-01

320

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

Energy Technology Data Exchange (ETDEWEB)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-11-01

321

Visualization of liquid metal two-phase flow by a real time neutron radiography system  

International Nuclear Information System (INIS)

In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).

1995-01-01

322

Use of ceramic porous membranes in molten carbonate fuel cells  

Energy Technology Data Exchange (ETDEWEB)

The diffusion of alkali vapours in the anode compartment of a DIR-MCFC produces the deactivation of the internal reforming catalyst. Sets of ceramic porous membranes purposed to limit the diffusion have been manufactured by different techniques and the influence of the preparation technique and of the preparative variables on the morphological characteristics of the membranes structures has been studied.

1996-12-31

323

Thermal performance of solar air collectors with a passive heat transfer augmentation technique  

Energy Technology Data Exchange (ETDEWEB)

One of the main disadvantages of solar air collectors in practical applications is their relatively low efficiency. In this experimental investigation, the shape and arrangement of absorber surfaces of the collectors were reorganized to provide better heat transfer surfaces suitable for the passive heat transfer augmentation techniques. The performance of such solar air collectors with staggered absorber sheets was tested. The experimental results show that it is possible to provide 10 to 25% enhancement in the efficiency compared to the conventional solar air collectors. (authors)

2000-07-01

324

The proton microprobe: Applications in the biomedical field  

Energy Technology Data Exchange (ETDEWEB)

This book explores the development, present, and future applications of proton microprobes in the micrometer range. Among the topics discussed: the use of proton beams for analytical purposes; techniques of focusing or collimating ion beams; improving and measuring beam spots; the analytical capabilities of the nuclear microprobe in comparison to other micro techniques; and applications and results by several internationally known microprobe laboratories.

1986-01-01

325

Technique for preliminary analysis and sizing of photovoltaic - thermal (PV-T) systems and associated components  

Energy Technology Data Exchange (ETDEWEB)

Design considerations of a combined photovoltaic-thermal (PV-T) system for a particular site and application must include thermal and electrical tradeoffs. A simplified technique for determining preliminary design and economic analyses would minimize costly computer simulation and indicate feasibility. To that end, nomographs that size an array to meet a specific annual load and determine the subsequent cost savings have been developed, and are presented in this paper.

1983-06-01

326

Synchronized Observations of Bubble Growth and Microlayer Evaporation in Horizontal Pool Boiling  

International Nuclear Information System (INIS)

The present study is aiming at the visualization of the boiling structures for various pool boiling and flow boiling conditions by applying multiple visualization techniques simultaneously. The bubble growth rate and microlayer behavior were simultaneously visualized for an isolated boiling regime of a water by using a shadow graph and a total reflection technique, respectively

2010-10-01

327

Surface-plasmon voltammetry using a gold grating  

Energy Technology Data Exchange (ETDEWEB)

Using a sensitive optical wavelength modulation technique the surface-plasmon excited on a gold grating surface immersed in sulfuric acid is studied at the same time as cyclic voltammetry is undertaken. Because of the optical sensitivity of the modulation technique significant optical effects are observed at potentials well below those at which any gross oxidation effects occur.

2010-09-29

328

Surface probe measurements in ISX-B and EBT-S  

Energy Technology Data Exchange (ETDEWEB)

Surface deposition probe techniques have been shown to be an effective means of determining the characteristics of the plasma edge region of magnetic confinement devices. Experimental results on ISX-B and EBT-S have led to a consistent picture of the edge plasma and the dominant impurity introduction mechanisms. This picture is supported by numerous other measurements and emphasizes the importance of concentrating several techniques on the complex problems of plasma fusion.

1982-12-01

329

Stress measurement and bolt tensioning by ultrasonic methods  

International Nuclear Information System (INIS)

In the past decade, a new technique has been developed for measuring tensile stresses in solids. This ultrasonic technique has been used thus far primarily for measuring fastener tension. The precision of measurement is routinely to 2-3% and, with special care, to approx. 1%. The method is insensitive to the frictional losses which plague tensioning by torque wrench. Though the approach is relatively new, it promises a wide range of applicability.

1980-01-01

330

Solar astrophysics  

Energy Technology Data Exchange (ETDEWEB)

This book comprises an up-to-date description of the astrophysical characteristics of the sun, including modern techniques used in solar research. Provides an historical background of solar research and techniques and covers the necessary astrophysics for solar studies, energy generation in the interior, the convection zone, the non- thermally heated layers, and solar wind are described in detail. Also considers the sun in relation to other stars, including information on its variable outputs of light, charged particles, and fields.

1990-01-01

331

Rev. 3 (15.01.2003)  

Wastenet

such as public utilities, waste disposal sites, large energy dependent facilities including factories, institutions ( ...provides immediate identification of PCB wastes, informs company officials of any special handling or disposal techniques ...provides immediate identification of PCB wastes, informs company officials of any special handling or disposal techniques

332

Remote sensing techniques in environmental monitoring  

Energy Technology Data Exchange (ETDEWEB)

This paper provides a review of current air and spaceborne remote sensing techniques which can be used in land use planning and resource management. Emphasis is placed on the development of geographic information systems (GS). It is expected remote sensing will become the preferred tool for data acquisition, while GIS will be used to manage and distribute georeferenced land information.

1990-06-01

333

Reconnaissance technique for radon risk classification of foundation soils  

Energy Technology Data Exchange (ETDEWEB)

Infiltration of radon from the ground is usually the primary source of indoor radon pollution. A uniform method for radon risk classification of foundation soils based on soil-gas radon concentration measurements and on the determination of soil porosity, permeability and structure was proposed in 1990. Results of assessment of some areas in Czechoslovakia, containing more than 5000 radon concentration measurements, demonstrate the utility of the technique and confirm the link between geology and radon potential of the soil. (author)

1992-07-01

334

Radionuclide demonstration of ventriculoatrial shunt-cutaneous fistula with cerebrospinal fluid leak  

International Nuclear Information System (INIS)

Radionuclide techniques have commonly been used to assess ventriculovenous shunt function, cerebrospinal fluid dynamics, and for the diagnosis of cerebrospinal fluid leaks. All of these techniques were utilized in this unusual case of retrograde migration of a ventriculoatrial catheter into the neck, with cutaneous fistulization and CSF leak. (orig.).

335

Process in Plasma Research at IPJ and IPPLM, POLAND  

International Nuclear Information System (INIS)

The most important results of theoretical and experimental studies of plasmas, which have been achieved at the IPJ in Swierk and IPPLM in Warsaw recently, are presented. Studies of physical phenomena in PF discharges, development of diagnostic techniques and research on new plasma technologies, as performed at IPJ, have been summarized. Studies of dense magnetized plasmas, investigation of physics and applications of laser-produced plasmas; and research on the development of advanced diagnostic techniques for the EUROATOM fusion program, as performed at IPPLM, are also described.

2006-01-01

336

Plasmids for the cloning and expression of full-length double-stranded cDNAs under control of the SV40 early or late gene promoter.  

UK PubMed Central (United Kingdom)

Okayama and Berg (1) have recently described a technique for the high efficiency cloning of full-length dscDNAs. We have constructed eukaryotic expression vectors compatible both with this technique...Full Text Available

1983-10-25

337

On new methods for standardization of samples in activation analysis of biological materials  

International Nuclear Information System (INIS)

New standardization techniques of samples in multielement instrumental neutron-activation analysis (INAA) of biological materials (BM) are considered. New methodical developments of sample preparation techniques, BM tableting, creation of comparison standards and standardization of packing material are suggested. Correlated data on concentration of different elements in standard specimens-comparison standards are presented for mass INAA, that is: for phenol-formaldehyde resin-base and human blood-base synthetic standards. 7 refs.; 3 tabs.

1988-06-26

338

New development of external-PIXE system using a differential pumping technique  

International Nuclear Information System (INIS)

A new external-PIXE system utilizing a differential pumping technique, which can completely protect the accelerator and vacuum pumps when the exit foil breaks down, has been developed. Applications to analyses of liquid and heavily-outgassing samples were successfully achieved. Also, experiments for evaluating the efficiency of the system were performed and results will be presented. (author)

1999-09-01

339

New concept in transmission line reclosure using high-frequency fault transients  

Energy Technology Data Exchange (ETDEWEB)

The authors present a new concept: 'adaptive optimal reclosure' under transmission line faults by integrating the adaptive and optimal reclosure techniques. Simulation studies prove that the proposed technique is able to first detect the persistence time of fault path arc and then capture the optimal reclosure time, thereby enhancing system stability. (author)

1997-07-01

340

Needs and opportunities for monitoring corrosion  

International Nuclear Information System (INIS)

Various electrochemical techniques are available to continuously monitor corrosion in conditions simulating those on the secondary side of PWR steam generators. This paper reviews those electrochemical techniques which are potentially useful to measure denting in tube-support crevices in situ. Attention is also given to corollary needs for monitoring the water chemistry which leads to corrosive attack. Finally some suggestions are offered for corrosion monitoring in autoclaves, model boilers and operating steam generators.

1985-03-01

341

Morphology of electrodeposited Ni/Cu multilayer: Specular and diffuse neutron reflectometry study  

Energy Technology Data Exchange (ETDEWEB)

Structural studies of Ni/Cu multilayers grown by electro-deposition technique under different electro-chemical conditions have been carried out using specular and off-specular neutron reflectometry techniques at room temperature. The specular reflectivity measurements give values of layer thickness, density and interface roughness for these two films. The Off-specular reflectivity measurements indicate different interface morphology of the two films.

2006-11-15

342

Micromachining using focused ion beams  

Energy Technology Data Exchange (ETDEWEB)

Focused ion beam (FIB) systems prove to be useful precision micromachining tools for a wide variety of applications. This micromachining technique includes scanning ion microscopy (SIM), micromachining by physical sputtering, and the ion-beam induced surface chemistry for etching and deposition. This technique is applied to image and modify IC's, to micromechanical applications, to modify the tip shape of tungsten emitters, and to prepare cross sections of selected regions for inspection in a transmission electron microscope (TEM). (orig.)

1994-11-16

343

Hal; a block level hardware logic simulator  

Energy Technology Data Exchange (ETDEWEB)

A special purpose hardware machine, which simulates up to one half-million gates and 2m byte RAM ICS at a 5 millisecond clock speed is described. This is accomplished with a hardware logic (HAL) simulator. This performance is achieved with 32 distributed special parallel processors, which utilize block oriented simulation technique. The technique promises a good cost hardware logic simulator. 7 references.

1983-01-01

344

Further means for reducing radiation dose during exposure of the pelvis in infants  

International Nuclear Information System (INIS)

A simple dose-saving procedure for the diagnosis of congenital hip dysplasia employing a diaphragm in nearfocus position is presented. Doses to the skin and the gonads were measured with a phantom for the new and other techniques. With optimal techniques the skin dose is smaller than 2 mR and the gonadal doses lie around 0.1 mR for both male and female patients. An estimate of the dose burden from undesired radiation is appended. (orig.).

345

Experimental regulation of advanced solar central receivers. Final report  

Energy Technology Data Exchange (ETDEWEB)

An investigation of natural convection losses from cavity-type solar central receivers is described and results are given. The approach followed was that of a fundamental experimental study in a simple cavity subject to well controlled boundary conditions. The Laser Doppler Velocimeter proved to be a useful technique to measure the velocity profiles associated with natural convection. Visualization techniques provided an understanding of the general behavior of the flow, particularly in three dimensional experiments. Experiments on systems of high Rayleigh numbers are described. (LEW)

1981-06-01

346

Evaluation of phased array UT conditions using ultrasonic visualization technique  

International Nuclear Information System (INIS)

Phased array provides many advantages over conventional ultrasonic testing method, but phased array has also limitations. This paper describes typical results of the experimental sound field analysis generated from the array probe. A photo-elastic ultrasonic visualization technique was applied in this study. The sound fields of shear wave generated from the array probe was equivalent to that from the fixed angle probe. (author)

2008-07-01

347

Evaluation of biliary disease by scintigraphy  

Energy Technology Data Exchange (ETDEWEB)

The value of biliary scintigraphy was studied in 180 patients with suspected biliary tract disease. Most of the patients were investigated additionally by conventional techniques such as cholecystography, cholangiography and ultrasonography. It is concluded that biliary scintigraphy is a simple and safe technique for visualization of the biliary tract. It is particularly useful in the evaluation of acute cholecystitis, in patients with iodine sensitivity obstructive from nonobstructive jaundice.

1981-01-01

348

Environmental effects and energy efficiency in building design - a green building approach. Pt. 1. Energy efficiency techniques  

Energy Technology Data Exchange (ETDEWEB)

A research report describes the energy efficiency techniques to be employed in designing a building which is ``green``. Topics covered include building fabric performance, ventilation and infiltration, passive solar design, heating systems and controls, hot and cold water provision, lighting and electrical appliances. (UK)

1993-12-31

349

Differential optical absorption techniques for diagnostics of coal gasification. Technical progress report, October, November, December 1982  

Energy Technology Data Exchange (ETDEWEB)

The application of differential optical absorption (DOA) techniques for the in-situ determination of the chemical composition of coal gasification process streams is investigated. Absorption spectra of relevant molecular species and the temperature and pressure effects on DOA-determined spectral characteristics of these species will be determined and cataloged. A system will be configured, assembled, and tested.

1983-04-01

350

Development of techniques for joining of high-sensitivity solar cells. Final report; Entwicklung von Verbindungstechniken fuer hoch empfindliche Solarzellen. Abschlussbericht  

Energy Technology Data Exchange (ETDEWEB)

The report investigates a number of joining techniques, i.e. isothermal solidification, ultrasonic welding, thermocompression, and glueing. (HW) [Deutsch] In diesem Vorhaben wurden verschiedene Verbindungstechniken untersucht: Isotherme Erstarrung; Ultraschall-Schweissen; Thermokompression; Leitkleben. (HW)

1992-09-01

351

Development of heavy-ion irradiation technique for single-event in semiconductor devices  

Energy Technology Data Exchange (ETDEWEB)

Heavy-ion irradiation technique has been developed for the evaluation of single-event effects on semiconductor devices. For the uniform irradiation of high energy heavy ions to device samples, we have designed and installed a magnetic beam-scanning system in a JAERI cyclotron beam course. It was found that scanned area was approximately 4 x 2 centimeters and that the deviation of ion fluence from the average value was less than 7%. (author)

1997-03-01

352

Determination of cesium and selenium in cultivated mushrooms using radionuclide X-ray fluorescence technique  

International Nuclear Information System (INIS)

Cesium and selenium intake of cultivated mushrooms (Agaricus bisporus), with these elements previously added to culture medium, has been examined from the viewpoint of health- and environmental protection. The process of measuring has been carried out by the radionuclide X-ray fluorescence technique. Treatments of the elementary substance with Se salt appears to influence the Se content of the mushrooms to a significant extent. Cs intake is of considerable importance, as this element is accumulated by mushrooms. (author)

2000-09-01

353

Computer tomographic ventriculography  

Energy Technology Data Exchange (ETDEWEB)

A method for elucidating complex abnormalities of CSF circulation by using a positive contrast medium (metrizamide) and computer tomography is described. The technique for the method, the results and their clinical significance is demonstrated. The value of this method is compared with traditional ventriculography and with computer tomography without the use of contrast medium. It is shown that the technique represents an important extension of the scope of computer tomography.

1982-04-01

354

Computer modeling in the design and evaluation of electric and hybrid vehicles  

Energy Technology Data Exchange (ETDEWEB)

This demonstration project uses modern simulation techniques to illustrate the important technologies and design variables that an auto-designer would consider in production a high efficiency, low emissions vehicle. Simulation and modeling techniques use the idea of capturing the relationships between real components of the systems with mathematical equations. These equations are then solved on a computer to simulate the behavior or performance of the system under various conditions. In the current demonstration project, we focus on many variations of a hydrogen-powered vehicle.

1996-08-16

355

Computed tomography - old ideas and new technology  

International Nuclear Information System (INIS)

Several recently introduced 'new' techniques in computed tomography - iterative reconstruction, gated cardiac CT, multiple-source, and dual-energy CT - actually date back to the early days of CT. We review the historic origins and evolution of these techniques, which may provide some insight into the latest innovations in commercial CT systems. (orig.)

2011-03-01

356

Compton scatter tomography and its inversion using a few projections  

Energy Technology Data Exchange (ETDEWEB)

Compton scatter tomography utilizes the electronic collimation characteristics available through the Compton scattering angle-energy correlation to obtain tomographic images. In this work we present particular aspects of the technique, which are relevant to the inverse radiation transport problem of reducing marginal projection data to radial two-phase flow regime maps. The results indicate a viable technique for the tomographic imaging of tow-phase flow using practical source strengths and reasonably few detectors.

1988-01-01

357

CT colonography: techniques of visualization and findings; CT Kolonographie: Techniken der Visualisierung und Befundung  

Energy Technology Data Exchange (ETDEWEB)

Evaluation and interpretation of CT colonography is based on both 2D and 3D techniques. The 2D techniques are popular mainly because the time needed for evaluation is short. The 3D techniques allow better definition than the 2D techniques, especially of polyps close to folds or at the base of a fold. The evaluation strategies generally accepted so far (primarily 2D, with 3D for problem cases, or vice versa) demand knowledge of both 2D and 3D techniques. Newer 3D visualization techniques help make it possible to acquire more complete and faster recording particularly of areas that are not easily accessible to endoscopic examination. These user-friendly developments are thus well suited to improving the detection and the security of detection of polyps. It must be remembered that experience and the knowledge of associated artifacts and the limitations they can ...

2008-02-15

358

Applications of Auger spectroscopy and ESCA to the study of thin films formed on metals  

International Nuclear Information System (INIS)

Various examples of applications of these two techniques are described. A part of them are related to the analysis of adsorbed layers formed during gaz-metal interactions. The others are concerned with the analysis of passive films formed during dry and wet corrosion. Problems related to the calibration of these techniques are discussed.

1979-05-23

359

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

Energy Technology Data Exchange (ETDEWEB)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.)

1993-10-01

360

Analytical peak fitting for gamma-ray spectrum analysis with Ge detectors  

International Nuclear Information System (INIS)

A comparison of maximum likelihood (or chi-square) and Bayesian peak fitting techniques shows that the latter can reduce peak intensity uncertainties by a factor of up to ten in the case of closely separated doublets, leading to greatly improved doublet resolution. The need for laboratories to demonstrate the reliability of their chosen peak fitting techniques and measures of peak intensity is also demonstrated. (orig.).

361

Analysis of microstructure of materials using a combination of a focused ion beam and transmission electron microscopy  

Energy Technology Data Exchange (ETDEWEB)

Recent development in application of a focused ion beam (FIB) technique to preparation of thin foil specimens for transmission electron microscopy (TEM) observation has been reviewed. Combined technique of FIB/TEM enables one to analyze those microstructures which have been almost impossible or very difficult to analyze so far. (author)

2002-03-01

362

A multi-micro-computer based dual-rate self-tuning power system stabilizer  

Energy Technology Data Exchange (ETDEWEB)

A dual-rate self-tuning control technique, in which the system identification and control calculation are performed separately, is proposed in this paper. This greatly increases the control rate. A self-tuning power system stabilizer (DSPSS) making use of this technique is developed and implemented using multi-micro-computers. Simulation and experimental results with DSPSS show that the increase in the control rate can considerably improve the system performance.

1987-09-01

363

Vacuum ultraviolet radiometry of xenon positive column discharges  

Energy Technology Data Exchange (ETDEWEB)

In order to judge the potential fluorescent lamp applications of various low-pressure positive column discharges it is necessary to measure the absolute power emitted in the ultraviolet region of the spectrum. For rare-gas discharges the principle emission occurs in the vacuum ultraviolet so that it is difficult to measure the radiant emittance (power per unit area) of the resonance radiation by standard methods. Two independent techniques are discussed for measuring the radiant emittance of positive column discharges in the vacuum ultraviolet. These techniques are used to study xenon positive column discharges at the resonance wavelength of 147 nm. The first method relies on the measurement of the resonance level density by absorption techniques. The effective decay rate of the resonance level is then determined by the simulation of resonance radiation transport. These two quantities are combined to yield the radiant ...

1995-10-01

364

Solid oxide fuel cell simulation and design optimization with numerical adjoint techniques  

Science.gov (United States)

This dissertation reports on the application of numerical optimization techniques as applied to fuel cell simulation and design. Due to the "multi-physics" inherent in a fuel cell, which results in a highly coupled and non-linear behavior, an experimental program to analyze and improve the performance of fuel cells is extremely difficult. This program applies new optimization techniques with computational methods from the field of aerospace engineering to the fuel cell design problem. After an overview of fuel cell history, importance, and classification, a mathematical model of solid oxide fuel cells (SOFC) is presented. The governing equations are discretized and solved with computational fluid dynamics (CFD) techniques including unstructured meshes, non-linear solution methods, numerical derivatives with complex variables, and sensitivity analysis with adjoint methods. Following the validation of the fuel cell model in ...

2008-01-01

365

Site characterization and petroleum hydrocarbon plume mapping  

Energy Technology Data Exchange (ETDEWEB)

This paper presents a case study of site characterization and hydrocarbon contamination plume mapping/delineation in a gas processing plant in southern Mexico. The paper describes innovative and cost-effective use of passive (non-intrusive) and active (intrusive) techniques, including the use of compound-specific analytical methods for site characterization. The techniques used, on a demonstrative basis, include geophysical, geochemical, and borehole drilling. Geochemical techniques used to delineate the horizontal extent of hydrocarbon contamination at the site include soil gas surveys. The borehole drilling technique used to assess the vertical extent of contamination and confirm geophysical and geochemical data combines conventional hollow-stem auguring with direct push-probe using Geoprobe. Compound-specific analytical methods, such as hydrocarbon fingerprinting and a modified method for gasoline ...

1996-12-31

366

Modification of the sheet resistance of ink jet printed polymer conducting films by changing the plastic substrate  

Energy Technology Data Exchange (ETDEWEB)

The ink jet printing technology is a relatively novel technique in development of organic electronic devices. The technique consists of working out depositions of organic layers by a piezo-based ink jet printer. In this work polymer conducting films deposited by ink jet printing technique on different plastic substrates has been demonstrated. The poly(3,4-ethylenedioxythiofene)/poly(4-styrenesulfonate) [PEDOT/PSS] and glycerol-modified PEDOT/PSS [G-PEDOT/PSS] were used like conducting inks to be applied on polyester and polyethylene terephthalate (PET) substrates. By means of the change of substrate associated to the deposition number or type of polymer ink used for printing of the conducting films, the sheet resistance can be modified. Such a behavior suggests that plastic substrate fulfills an important role for the changing of sheet resistance of the PEDOT/PSS and G-PEDOT/PSS films made by ink jet printing ...

2005-09-25

367

Irradiating the groin nodes without breaking a leg: A comparison of techniques for groin node irradiation  

International Nuclear Information System (INIS)

The purpose of this study was to determine the optimal technique for delivering postoperative radiotherapy for vulvar cancer and other tumors requiring treatment of the inguinal nodes. This project compared tumor coverage and normal tissue sparing for the 5 main radiotherapy techniques that are used to treat vulvar cancer. The intensity-modulated radiation therapy (IMRT) plan was undesirable because it resulted in an excessive dose to portions of the central pelvic structures. The photon thunderbird with skin match was unacceptable because it underdosed a portion of the groin region. The electron thunderbird was ideal for thin patients but was not applicable for most patients because of excessive dose to the skin and subcutaneous tissues. The photon through-and-through and the photon thunderbird with deep match were acceptable in most situations. In thin patients, where the depth of the inguinal vessels is less than 3 cm, the electron ...

368

Full Spin and Spatial Symmetry Adapted Technique for Correlated Electronic Hamiltonians: Application to an Icosahedral Cluster  

CERN Document Server

While dealing with molecular systems, it is highly advantageous to work with a basis set which has definite total spin and also belongs to a definite irreducible representation of its symmetry (point) group. But unfortunately, there hadn't been any general simple technique to deal with the problem, especially when molecule possesses non-Abelian point group symmetry. In a previous paper \\cite{sahoo}, we presented a general technique which is a hybrid method based on Valence Bond basis and the basis of z-component of the total spin. The technique is applicable to all types of point groups and is easy to implement on computer. We illustrated the power of the method by applying it to a molecular magnetic system. Here we extend the method to electronic systems and demonstrate this extended technique by applying it to a model icosahedral half-filled electronic system (12 sites). Reasons we took this model ...

2010-01-01

369

Focused ion beam techniques for fabricating geometrically-complex components and devices.  

Energy Technology Data Exchange (ETDEWEB)

We have researched several new focused ion beam (FIB) micro-fabrication techniques that offer control of feature shape and the ability to accurately define features onto nonplanar substrates. These FIB-based processes are considered useful for prototyping, reverse engineering, and small-lot manufacturing. Ion beam-based techniques have been developed for defining features in miniature, nonplanar substrates. We demonstrate helices in cylindrical substrates having diameters from 100 {micro}m to 3 mm. Ion beam lathe processes sputter-define 10-{micro}m wide features in cylindrical substrates and tubes. For larger substrates, we combine focused ion beam milling with ultra-precision lathe turning techniques to accurately define 25-100 {micro}m features over many meters of path length. In several cases, we combine the feature defining capability of focused ion beam bombardment with additive techniques such as ...

2004-03-01

370

Calorimetric measurements of emittance of pipe surfaces: influence of enclosure diameter, test pipe length, and an argon atmosphere  

Energy Technology Data Exchange (ETDEWEB)

Additional results using a calorimetric technique for measuring the total hemispherical emittance of pipe surfaces from 400 to 600 K are described. Two different Pyrex pipe enclosures were used, one of 15 cm i.d. and the other of 30 cm i.d. An error analysis showed that the larger diameter Pyrex pipe should have a smaller error, but the difference was negligible for the 4.4-cm test pipe diameter used. Measurements on a short length of a previously-measured pipe agreed with earlier measurements, but only over the temperature range of the measurements. While the technique normally uses a vacuum to minimize nonradiative heat transfer, measurements were done succesfully with an argon atmosphere in a closed system. A nickel-plated pipe, measured first in a vacuum and then in an argon atmosphere, allowed calculation of an effective convective heat-transfer coefficient for use with test pipes of unknown emittances. Measurements done with an atmosphere ...

1981-10-01

371

Boat sampling technique for assessment of ageing of components  

International Nuclear Information System (INIS)

Boat sampling technique (BST) is a surface sampling technique, which has been developed for obtaining, in-situ, metal samples from the surface of an operating component without affecting its operating service life. The BST is non-destructive in nature and the sample is obtained without plastic deformation or without thermal degradation of the parent material. The shape and size of the sample depends upon the shape of the cutter and the surface geometry of the parent material. Miniature test specimens are generated from the sample and the specimens are subjected to various tests, viz. Metallurgical Evaluation, Metallographic Evaluation, Micro-hardness Evaluation, sensitisation test, small punch test etc. to confirm the integrity and assessment of safe operating life of the component. This paper highlights design objective of boat sampling technique, description of sampling module, sampling cutter and its performance ...

2006-11-01

372

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence ...

1992-01-01

373

Application of grazing incidence x-ray diffraction to polymer blends  

Energy Technology Data Exchange (ETDEWEB)

The physical properties of polymer blends consisting of one or more crystallizable components are affected by the microstructure of these materials. In particular, the degree of crystallinity can be influenced by processing parameters, and the crystallinity, as well as the phase distribution, may vary as a function of depth through an injection molded part Conventional x-ray diffraction techniques can provide information regarding both phase composition and degree of crystallinity, but, because of the relative transparency of these materials to wavelengths generally available in the laboratory, these techniques provide information representative of only the bulk. By employing parallel beam optics at varying grazing incidence angles, the x-ray sampling depth can be varied without loss of resolution. This technique can be used to vary the effective analysis depth from the top several hundred angstroms for low razing incidence ...

1992-10-01

374

Aerodynamic force measurement on a large-scale model in a short duration test facility  

International Nuclear Information System (INIS)

A force measurement technique has been developed for large-scale aerodynamic models with a short test time. The technique is based on direct acceleration measurements, with miniature accelerometers mounted on a test model suspended by wires. Measuring acceleration at two different locations, the technique can eliminate oscillations from natural vibration of the model. The technique was used for drag force measurements on a 3 m long supersonic combustor model in the HIEST free-piston driven shock tunnel. A time resolution of 350 #mu#s is guaranteed during measurements, whose resolution is enough for ms order test time in HIEST. To evaluate measurement reliability and accuracy, measured values were compared with results from a three-dimensional Navier-Stokes numerical simulation. The difference between measured values and numerical simulation values was less than 5%. We conclude that this measurement ...

2005-03-01

375

Guidelines for the use of structural reliability and risk based techniques to justify the operation of onshore pipelines at design factors greater than 0.72; Directives concernant l'emploi des techniques de risque/fiabilite structurels afin de justifier l'exploitation de gazoducs terrestres a des coefficients de securite superieurs a 0,72  

Energy Technology Data Exchange (ETDEWEB)

Structural reliability and risk based techniques have recently been used to demonstrate safe operation of high-pressure pipelines at design factors greater than 0.72. In particular several pipelines are now operating on the Transco National Transmission System, in the UK, at design factors of 0.78 owing to the use of the techniques. The overall structural reliability and risk based approach for justifying safe operation of pipelines at these stress levels is thus now established. However, in order to establish cost effective and viable widespread use of the technique, formal guidelines are necessary which will allow analyses to be performed with minimal requirements for regulator liaison meetings, external audits and extensive reporting. Structured and comprehensive guidelines, which have recently been constructed based on extensive analytical consideration of the underlying issues, are presented in this paper. The ...

2000-07-01

376

Effect of inhaled beclomethasone dipropionate on isocapnic hyperventilation with cold air in asthmatics, measured with forced oscillation technique.  

Science.gov (United States)

Isocapnic hyperventilation with cold air (IHCA) is a reliable technique for assessing indirect bronchial hyperresponsiveness in patients with asthma. Impedance measurement of the respiratory system by the forced pseudorandom noise oscillation technique is a sensitive technique to assess changes in bronchial tone after IHCA. The aim of this study was to evaluate the effect of 6 weeks of treatment with beclomethasone dipropionate, 1,000 microg x day-1, on IHCA in asthmatic patients, measured with both forced oscillation technique and flow-volume recordings. Forty patients with mild asthma were included in this double-blind, placebo-controlled parallel-group study. Stratification on the basis of sex was performed to overcome differences in airway diameter. At entry and every 2 weeks during the treatment period, IHCA was performed and patient diaries were evaluated. Characteristic changes in forced ...

1997-03-01

377

Thermoelectrically cooled water trap  

Energy Technology Data Exchange (ETDEWEB)

A water trap system based on a thermoelectric cooling device is employed to remove a major fraction of the water from air samples, prior to analysis of these samples for chemical composition, by a variety of analytical techniques where water vapor interferes with the measurement process. These analytical techniques include infrared spectroscopy, mass spectrometry, ion mobility spectrometry and gas chromatography. The thermoelectric system for trapping water present in air samples can substantially improve detection sensitivity in these analytical techniques when it is necessary to measure trace analytes with concentrations in the ppm (parts per million) or ppb (parts per billion) partial pressure range. The thermoelectric trap design is compact and amenable to use in a portable gas monitoring instrumentation.

2006-02-21

378

Theory of edge radiation  

CERN Document Server

We formulate a complete theory of Edge Radiation based on a novel method relying on Fourier Optics techniques. Similar types of radiation like Transition Undulator Radiation are addressed in the framework of the same formalism. Special attention is payed in discussing the validity of approximations upon which the theory is built. Our study makes consistent use of both similarity techniques and comparisons with numerical results from simulation. We discuss both near and far zone. Physical understanding of many asymptotes is discussed. Based on the solution of the field equation with a tensor Green's function technique, we also discuss an analytical model to describe the presence of a vacuum chamber. In particular, explicit calculations for a circular vacuum chamber are reported. Finally, we consider the use of Edge Radiation as a tool for electron beam diagnostics. We discuss Coherent Edge Radiation, Extraction of Edge ...

2008-01-01

379

The development of technology on chicken yard design and its environment control  

Energy Technology Data Exchange (ETDEWEB)

The objective of this study is development of technology on chicken yard design and its environment control. For this objective, the micro processor interface techniques and related programming techniques have been surveyed, and the chicken yard environment monitoring system has been developed that equipped with micro computer and signal measurement module. Software has also been developed that operated the system and analyzes measured data. By using micro computer and signal input/output module, the system can have various functions, such as monitoring, alarm, and data analysis function. Three dimensional graphic modeling of a chicken yard is performed using graphic package in this study. Application of three dimensional modeling technique make it easy to design chicken yard. 9 figs. (Author)

1996-04-01

380

The application of the neutron time-of-flight technique for real-time diffraction studies  

Energy Technology Data Exchange (ETDEWEB)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

381

The application of the neutron time-of-flight technique for real-time diffraction studies  

International Nuclear Information System (INIS)

Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).

1991-12-01

382

The RooStats Project  

CERN Document Server

RooStats is a project to create advanced statistical tools required for the analysis of LHC data, with emphasis on discoveries, confidence intervals, and combined measurements. The idea is to provide the major statistical techniques as a set of C++ classes with coherent interfaces, which can be used on arbitrary model and datasets in a common way. The classes are built on top of RooFit, which provides a very convenient functionality for modeling the probability density functions or the likelihood functions, required as inputs for any statistical technique. Furthermore, RooFit provides the functionality for easily creating models, for analysis combination and for digital publication of the likelihood function and the data. We will present in detail the design and the implementation of the different statistical methods of RooStats. These include various classes for interval estimation and for hypothesis test depending on different statistical ...

2010-01-01

383

Technical evaluation report for the demonstration of radio frequency soil decontamination at Site S-1  

Energy Technology Data Exchange (ETDEWEB)

The Air Force`s Armstrong Laboratory at Tyndall Air Force Base, Florida, has supported the research and development of Radio Frequency Soil Decontamination. Radio frequency soil decontamination is essentially a heat-assisted soil vapor extraction process. Site S-1 at Kelly Air Force Base, San Antonio, Texas, was selected for the demonstration of two patented techniques. The site is a former sump that collected spills and surface run-off from a waste petroleum, oils, and lubricants and solvent storage and transfer area. In 1993, a technique developed by the IIT Research Institute using an array of electrodes placed in the soil was demonstrated. In 1994, a technique developed by KAI Technologies, Inc. using a single applicator placed in a vertical borehole was demonstrated. Approximately 120 tons of soil were heated during each demonstration to a temperature of about 150 degrees Celsius.

1995-04-01

384

Standardisation of "2"1"0Pb by Cerenkov counting  

International Nuclear Information System (INIS)

A standard of "2"1"0Pb in solution was produced at the National Physical Laboratory by a novel technique combining Cerenkov counting with the established liquid scintillation efficiency tracing technique known as the CIEMAT/NIST method. Coincidence counting was applied in order to validate the measurements and the activity concentrations of the solution determined with each technique are shown to be in agreement. Radiochemical separation of the "2"1"0Pb from its daughters was also necessary and the scheme for the separation is described. After performing this two-stage standardisation, the uncertainty was successfully lowered to 0.66% (k=1). This uncertainty is approximately a factor of four lower than previously achieved at NPL by the classical method of standardisation of radionuclides, i.e. coincidence counting.

2011-05-01

385

SCC mitigation method for BWR materials by TiO2 technique  

International Nuclear Information System (INIS)

TiO2 addition into boiling water reactor (BWR) primary system is being developed as a method to mitigate stress corrosion cracking (SCC) of the BWR structural materials. This technique aims for electrochemical corrosion potential (ECP) decrease of reactor materials by photo-excitation reaction under Cherenkov irradiation. ECP measurement tests have been conducted in the test loop in BWR to investigate the feasibility of the SCC mitigation method with TiO2. The test results showed that the ECP of TiO2 deposited materials was decreased to 2 technique was confirmed to be feasible as a SCC mitigation method for BWR structural materials without hydrogen injection. (author)

2008-10-13

386

Radiotherapy for nonfunctioning pituitary adenomas: from conventional to modern stereotactic radiation techniques  

British Library Electronic Table of Contents (United Kingdom)

The initial management of nonfunctioning pituitary macroadenomas (NFAs) is usually surgery; however, a significant proportion of NFAs may require further treatment. Radiotherapy is currently used in patients with residual tumour and achieves excellent long-term control, but there are concerns about potential late toxicity. Stereotactic radiotherapy, both in the form of radiosurgery or fractionated stereotactic radiotherapy, has been developed as a more accurate technique of irradiation with more precise tumour localization and consequently a reduction in the volume of normal tissue, particularly the brain, irradiated to high radiation doses. A review of the literature suggests that new radiation techniques offer safe and effective treatment for recurrent or residual pituitary adenomas; how...

2007-01-01

387

Quantitative measurement of elements in a composite, using multienergy gamma-rays  

International Nuclear Information System (INIS)

This study is an attempt to measure the quantities of elements in a composite by irradiating that composite with #gamma#-rays of various energies and detecting the transmitted radiation through the composite. A previous knowledge of the number of the elements and their attenuation coefficients is required. The quantities are calculated by solving the matrix of a linear system of equations. A computer program was developed to select the best combinations of the available energies. Five criteria were established to determine these energy combinations: (i) the determinant of the attenuation coefficient matrix; (ii) the condition number, (iii) the number of times the solution of the matrix leads to acceptable results; (iv) the indicator, (a new concept); (v) the standard deviations of the results. The intended application of this technique in medicine is to measure the bone mineral content of the skeleton. An examination of the error propagation, the application of ...

388

Picosecond pulse-conductivity technique applied to study excess-electron reactions in hydrocarbon mixtures  

Energy Technology Data Exchange (ETDEWEB)

To measure electron reactions on a picosecond timescale the investigators developed a picosecond pulse-conductivity technique, which makes use of the electron fine-structure pulses of our LINAC (pulse width 25 vs FWHM) to produce excess electrons and now detects changes in sample conductance under optimum conditions with an instrumental response of 18 ps. This resolution is in agreement with a theoretical estimate. This technique has been successfully applied to study excess electron reactions in solvents covering a mobility range from 0.24 to 100 cm/sup 2/V/sup -1/s/sup -1/; extension to lower mobility liquids seem possible.

1983-01-01

389

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

International Nuclear Information System (INIS)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

390

Onset of nucleate boiling and onset of fully developed subcooled boiling using pressure transducers signals spectral analysis  

Energy Technology Data Exchange (ETDEWEB)

The experimental technique used for detection of subcooled boiling through analysis of the fluctuation contained in pressure transducer signals is presented. This work was partly conducted at the Institut fuer Kerntechnik und zertoerungsfreie Pruefverfahren von Hannover (IKPH, Germany) in a thermal-hydraulic circuit with one electrically heated rod with annular geometry test section. Piezo resistive pressure sensors are used for onset of nucleate boiling (ONB) and onset of fully developed boiling (OFDB) detection using spectral analysis/ signal correlation techniques. Experimental results are interpreted by phenomenological analysis of these two points and compared with existing correlation. The results allow to conclude that this technique is adequate for the detection and monitoring of the ONB and OFDB. (author)

2001-12-01

391

Numerical analysis of melting/solidification phenomena using a moving boundary problem analysis method X-FEM  

International Nuclear Information System (INIS)

A numerical analysis method for melting/solidification phenomena has been developed to evaluate a feasibility of several candidate techniques in the nuclear fuel cycle. Our method is based on the eXtended Finite Element Method (X-FEM) which has been used for moving boundary problems. Key technique of the X-FEM is to incorporate signed distance function into finite element interpolation to represent a discontinuous gradient of the temperature at a moving solid-liquid interface. Construction of the finite element equation, the technique of quadrature and the method to solve the equation are reported here. The numerical solutions of the one-dimensional Stefan problem, solidification in a two-dimensional square corner and melting of pure gallium are compared to the exact solutions or to the experimental data. Through these analyses, validity of the newly developed numerical analysis method has been demonstrated. (author)

2008-06-01

392

Nitriding using cathodic cage technique of austenitic stainless steel AISI 316 with addition of CH{sub 4}  

Energy Technology Data Exchange (ETDEWEB)

Samples of austenitic stainless steel AISI 316 were nitrided using the cathodic cage technique with the addition of methane in the nitriding atmosphere. The aim was to study the influence of this technique in reducing the precipitation of chromium nitrite and in improving the wear resistance. The results show that there was a significant improvement in such properties when compared to the results of ionic plasma nitriding. Formation of a double layer, one more internal composed of carbon and another with high nitrogen content, was confirmed by Scanning Electron Microscopy (SEM). The microhardness profile of the layer showed an increase in hardness values and a larger uniformity, while X-ray analysis showed less chromium nitriding precipitation when compared with results obtained for samples treated using ionic plasma nitriding.

2008-07-25

393

N-Body Code with Adaptive Mesh Refinement  

CERN Document Server

We have developed a simulation code with the techniques which enhance both spatial and time resolution of the PM method for which the spatial resolution is restricted by the spacing of structured mesh. The adaptive mesh refinement (AMR) technique subdivides the cells which satisfy the refinement criterion recursively. The hierarchical meshes are maintained by the special data structure and are modified in accordance with the change of particle distribution. In general, as the resolution of the simulation increases, its time step must be shortened and more computational time is required to complete the simulation. Since the AMR enhances the spatial resolution locally, we reduce the time step locally also, instead of shortening it globally. For this purpose we used a technique of hierarchical time steps (HTS) which changes the time step, from particle to particle, depending on the size of the cell in which particles reside. ...

2001-01-01

394

Mississippi exploration field trials using microbial, radiometrics, free soil gas, and other techniques  

Energy Technology Data Exchange (ETDEWEB)

The Mississippi Office of Geology has conducted field trials using the surface exploration techniques of geomicrobial, radiometrics, and free soil gas. The objective of these trials is to determine if Mississippi oil and gas fields have surface hydrocarbon expression resulting from vertical microseepage migration. Six fields have been surveyed ranging in depth from 3,330 ft to 18,500 ft. The fields differ in trapping styles and hydrocarbon type. The results so far indicate that these fields do have a surface expression and that geomicrobial analysis as well as radiometrics and free soil gas can detect hydrocarbon microseepage from pressurized reservoirs. All three exploration techniques located the reservoirs independent of depth, hydrocarbon type, or trapping style.

1995-12-31

395

Methods for proving the equivalency of detonator performance  

Energy Technology Data Exchange (ETDEWEB)

One of the challenges facing engineers is developing newer, safer detonators that are equivalent to devices currently in use. There is no clear consensus on an exact method for drawing equivalence of detonators. This paper summarizes our current efforts to develop diagnostics addressing various aspects of detonator design to better quantify and prove equivalency. We consider various optical techniques to quantify the output pressure and output wave shape. The development of a unique interpretation of streak camera breakouts, known as the apparent center of initiation, will be discussed as a metric for detonation wave shape. Specific examples apply these techniques to the comparison of a new laser-driven detonator with an existing exploding bridgewire (EBW) detonator. Successes and short-comings of the techniques will be discussed.

2009-01-01

396

Low-dose contrast protocol using the test bolus technique for 64-detector computed tomography coronary angiography  

British Library Electronic Table of Contents (United Kingdom)

Purpose We evaluated low-contrast injection protocols for coronary computed tomography angiography (CTA) using a 64-detector scanner and the test bolus technique. Materials and methods We randomly assigned 60 patients undergoing coronary CTA to one of two contrast material (CM) injection protocols. For the lowcontrast dose protocol (Plow), the patients received injections of iohexol-350 [0.7 ml/kg body weight (BW)] during 9 s, and the test-bolus technique was used. Under the conventional protocol (Pconv), they received iohexol-350 (1.0 ml/kg BW) during 15 s, and bolus tracking was used. We compared the protocols for attenuation values in the ascending aorta and coronary arteries and for the amount of CM required. Results There was no significant difference in the mean CT attenuation of the...

2011-01-01

397

Learning and case-based reasoning for faults diagnosis-aiding in nuclear power plants  

International Nuclear Information System (INIS)

The aim of this thesis is the design of a faults diagnosis-aiding system in a nuclear facility of the Cea. Actually the existing system allows the optimization of the production processes in regular operating conditions. Meanwhile during accidental events, the alarms, managed by threshold, are bringing no relevant information. To increase the reliability and the safety, the human operator needs a faults diagnosis-aiding system. The developed system, SECAPI, combines problem solving techniques and automatic learning techniques, that allow the diagnosis and the the simulation of various faults happening on nuclear facilities. Its reasoning principle uses case-based and rules-based techniques. SECAPI owns a learning module which reads out knowledge connected with faults. It can then simulate various faults, using the inductive logical computing. SECAPI has been applied on a radioactive tritium treatment operating channel, at ...

1998-01-01

398

Ion exchange chromatographic separation and MS analysis of isotopes of boron  

International Nuclear Information System (INIS)

Using electrochemical techniques of pH-metry and conductimetry, the choice of a suitable complexing reagent was made amongst ethylene glycol, propylene glycol, dextrose and mannitol for cost-effective separation of isotopes of boron by ion exchange chromatography. Quantitative relationships between pH and concentration; pK_a and concentration of each of these complexing reagents were determined by least square polynomial curve fitting and an attempt was made to determine the formation constants of mannitol-borate complex. The results of experiments carried out for selection; regeneration of a resin; separation factor determinations using batch as well as column techniques and monitoring of band movements using these electrochemical techniques are discussed. (author).

1997-05-18

399

Intermediate Strain-Rate Loading Experiments - Technique and Applications to Ceramics  

Energy Technology Data Exchange (ETDEWEB)

A new test methodology is described which allows access to loading rates that lie between split Hopkinson bar and shock-loading techniques. Gas gun experiments combined with velocity interferometry techniques have been used to experimentally determine the intermediate strain-rate loading behavior of Coors AD995 alumina and Cercom silicon-carbide rods. Graded-density materials have been used as impactors; thereby eliminating the tension states generated by the radial stress components during the loading phase. Results of these experiments demonstrate that the time-dependent stress pulse generated during impact allows an efficient transition from the initial uniaxial strain loading to a uniaxial stress state as the stress pulse propagates through the rod. This allows access to intermediate loading rates over 5 x 10{sup 3}/s to a few times 10{sup 4}/s.

1999-08-16

400

Improving Term Extraction Using Particle Swarm Optimization Techniques  

CERN Document Server

Term extraction is one of the layers in the ontology development process which has the task to extract all the terms contained in the input document automatically. The purpose of this process is to generate list of terms that are relevant to the domain of the input document. In the literature there are many approaches, techniques and algorithms used for term extraction. In this paper we propose a new approach using particle swarm optimization techniques in order to improve the accuracy of term extraction results. We choose five features to represent the term score. The approach has been applied to the domain of religious document. We compare our term extraction method precision with TFIDF, Weirdness, GlossaryExtraction and TermExtractor. The experimental results show that our propose approach achieve better precision than those four algorithm.

2010-01-01

401

High-precision Absolute Distance and Vibration Measurement using Frequency Scanned Interferometry  

CERN Document Server

In this paper, we report high-precision absolute distance and vibration measurements performed simultaneously with frequency scanned interferometry using a pair of single mode optical fibers. Absolute distance was determined by counting the interference fringes produced while scanning the laser frequency. A high-finesse Fabry-Perot interferometer(F-P) was used to determine frequency changes during scanning. Two multi-distance-measurement analysis techniques were developed to improve distance precision and to extract the amplitude and frequency of vibrations. Under laboratory conditions, a precision of 40 nm was demonstrated for an absolute distance of approximately 0.45 meters using the first analysis technique. The second analysis technique has capability to measure vibration frequencies ranging from 0.1 Hz to 100 Hz with minimal amplitude on few nanometers order without a priori knowledge.

2004-01-01

402

Gauging film thickness: A comparison of an x-ray diffraction technique with Rutherford backscattering spectrometry  

Energy Technology Data Exchange (ETDEWEB)

An x-ray diffraction technique for determining thin-film thickness is presented which should prove to be a valuable alternative to the array of spectroscopies (Rutherford backscattering spectrometry, Auger electron spectroscopy, etc.) currently favored for these measurements. Some of the virtues of this x-ray diffraction approach are its nondestructive nature, fast data acquisition rate (enabling in situ observations), thickness resolution better than 5 nm, and conventional equipment requirements. Results are shown for Pd/sub 2/Si thin films grown during isothermal annealing of Pd coatings (100 nm) on Si at 200 /sup 0/C for various amounts of time. A comparison of these x-ray measurements with Rutherford backscattering spectrometry data taken from the same specimens is used to demonstrate the validity of the x-ray technique.

1985-01-15

403

Final report: technical contributions to the development of incipient fault detection/location instrumentation  

Energy Technology Data Exchange (ETDEWEB)

The transmission of electrical energy by use of underground cables is increasing. Fault location techniques have certain limitations; incipient fault detection and location would help reduce the maintenance cost of these lines as well as improve the reliability of service. The report discusses some test results related to RF-probing techniques applied to high-voltage transmission lines. The high-frequency losses and attenuation in high-voltage cables places certain ultimate limitations on RF-probing techniques for incipient fault detection. Time-domain reflectrometry methods were employed to assess the RF-transmission properties of high-voltage cables at frequencies as high as 6 GHz. Fast-Fourier-transform deconvolution was used to obtain loss measurements as a function of frequency. The loss mechanisms were identified. The measurement hardware and methods are discussed as well as analysis approach leading to the ...

1986-04-01

404

Fermion determinants in lattice QCD  

CERN Document Server

The main topic of this thesis concerns efficient algorithms for the calculation of determinants of the kind of matrix typically encountered in lattice QCD. In particular an efficient method for calculating the fermion determinant is described. Such a calculation is useful to illustrate the effects of light dynamical (virtual) quarks. The methods employed in this thesis are stochastic methods, based on the Lanczos algorithm, which is used for the solution of large, sparse matrix problems via a partial tridiagonalisation of the matrix. Here an implementation is explored which requires less exhaustive treatment of the matrix than previous Lanczos methods. This technique exploits the analogy between the Lanczos tridiagonalisation algorithm and Gaussian quadrature in order to calculate the fermion determinant. A technique for determining a number of the eigenvalues of the matrix is also presented. A demonstration is then given of how one can improve ...

2001-01-01

405

Enthalpy and mass flowrate measurements for two-phase geothermal production by Tracer dilution techniques  

Energy Technology Data Exchange (ETDEWEB)

A new technique has been developed for the measurement of steam mass flowrate, water mass flowrate and total enthalpy of two-phase fluids produced from geothermal wells. The method involves precisely metered injection of liquid and vapor phase tracers into the two-phase production pipeline and concurrent sampling of each phase downstream of the injection point. Subsequent chemical analysis of the steam and water samples for tracer content enables the calculation of mass flowrate for each phase given the known mass injection rates of tracer. This technique has now been used extensively at the Coso geothermal project, owned and operated by California Energy Company. Initial validation of the method was performed at the Roosevelt Hot Springs geothermal project on wells producing to individual production separators equipped with orificeplate flowmeters for each phase.

1993-01-28

406

Electron Capture Dissociation Implementation Progress in Fourier Transform Ion Cyclotron Resonance Mass Spectrometry  

British Library Electronic Table of Contents (United Kingdom)

Successful electron capture dissociation (ECD) Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR MS) applications to peptide and protein structural analysis have been enabled by constant progress in implementation of improved electron injection techniques. The rate of ECD product ion formation has been increased to match the liquid chromatography and capillary electrophoresis timescales, and ECD has been combined with infrared multiphoton dissociation in a single experimental configuration to provide simultaneous irradiation, fast switching between the two techniques, and good spatial overlap between ion, photon, and electron beams. Here we begin by describing advantages and disadvantages of the various existing electron injection techniques for ECD in FT-ICR MS. We next ...

2008-01-01

407

Direct detection of Salmonella without pre-enrichment in milk, ice-cream and fruit juice by PCR against hilA gene  

British Library Electronic Table of Contents (United Kingdom)

A novel PCR based assay was devised to specifically detect contamination of any Salmonella serovar in milk, fruit juice and ice-cream without pre-enrichment. This method utilizes primers against hilA gene which is conserved in all Salmonella serovars and absent from the close relatives of Salmonella. An optimized protocol, in terms time and money, is provided for the reduction of PCR contaminants from milk, ice-cream and juice through the use of routine laboratory chemicals. The simplicity, efficiency (time taken 3-4 h) and sensitivity (to about 5-10 CFU/ml) of this technique confers a unique advantage over other previously used time consuming detection techniques. This technique does not involve pre-enrichment of the samples or extensive sample processing, which was a pre-requisite in mos...

2012-01-01

408

Development of in-vessel reflood instrumentation at ORNL  

International Nuclear Information System (INIS)

A program under the sponsorship of the United States Nuclear Regulatory Commission was intiated at the Oak Ridge National Laboratory (ORNL) in late 1977. The program, Advanced Instrumentation for Reflood Studies (AIRS), is charged with developing instrumentation for measurement of in-vessel fluid phenomena in pressurized water reactor reflood facilities. The goal of the ORNL program is to develop techniques and systems for measuring fluid flow in-core, deentrainment in the upper plenum and liquid fallback from the upper plenum into the core. A large portion of the development at ORNL is devoted to the impedance probes for measurement of two-phase flow velocities and void fractions. Film probe development at ORNL is limited to adapting the present techniques to the environment of a reflood facility. As the development progresses on all the measurement techniques, ORNL will fabricate and supply instrument systems to the ...

2004-09-06

409

Design and operation of an apparatus for calorimetric emittance measurements of pipe surfaces  

Energy Technology Data Exchange (ETDEWEB)

A technique for the measurement of the total hemispherical emittance of pipe surfaces is described, and design and operational details are given. The technique is conceptually simple. A long test pipe (e.g., 3.4 m) is mounted concentrically inside a Pyrex glass pipe. The system is evacuated, and the test pipe is heated by means of an electrical resistance heater. Heat transfer from the test pipe to the enclosure is almost solely radiative, allowing an average emittance for the test pipe and the Pyrex pipe and the electrical power input to the heater. By varying the electrical power level, one can measure the test pipe emittance as a function of temperature. By using a simple correction to account for the finite length of the test pipe, one can calculate the results using the simple expression for infinite, concentric cylinders. Results agree with measurements by reflectance techniques and have a nominal relative error of ...

1981-10-01

410

Demonstration experiments of volume measurement technique for large scale input accountancy tank  

International Nuclear Information System (INIS)

Tank calibration experiments have been carried out using a mock-up input accountancy tank with the object of developing a high accuracy solution volume measurement technique for Rokkasho Reprocessing Plant (RRP). The experimental parameters such as temperature, solution density, off gas pressure and so on have been fluctuated in the calibration experiments in order to evaluate the influence on the solution volume measurement. As a result, it was confirmed that the solution volume measurement error of the mock-up tank was within #+-#0.04% (at full volume) using careful data correction technique for measured data. For the high accuracy volume measurement at RRP, it is important to correct data properly taking account of the actual conditions such as uncontrollable ambient temperature that are different from the experiment. (author)

2000-12-07

411

Carbohydrates/nucleosides/RNA-DNA-ligand interactions  

Energy Technology Data Exchange (ETDEWEB)

Carbohydrate and nucleotide structural determination using modern spectroscopic techniques is dependent on our ability to label oligonucleotides and oligosaccharides with stable isotopes. Uniform Carbon 13 and Nitrogen 15 labeling of oligonucleotides is important to present-day efforts, which are focused on determining the structure of relatively small oligosaccharides and oligonucleotides, which form the elements of larger structures. Because of the relatively recent interest in three-dimensional structure, the development of techniques used to label them has lagged behind parallel techniques used to label peptides and proteins. Therefore, this group`s discussion focused primarily on problems faced today in obtaining oligonucleotides labeled uniformly with carbon 13 and nitrogen 15.

1994-12-01

412

Bumper zone at the Aldermac mine tailing site : study of certain remediation techniques; Zones d'epanchement du parc a residus miniers Aldermac : etude de certaines techniques de rehabilitation  

Energy Technology Data Exchange (ETDEWEB)

Acid mine drainage is probably the most important problem facing the mining industry. In this study, the authors evaluated different techniques for the remediation of mine tailings. An in situ characterization of the Aldermac mine tailings was conducted and the results were presented in this poster presentation. The site characterization was performed to determine the extent of the contamination, and sampling of soils was also performed for laboratory experiments in soil covers. The authors described the methodology followed in the laboratory experiments. Chemical analysis of the leaching water was performed to determine its composition in metals. Microbiological analysis was also conducted, as well as the determination of the water saturation index. The authors indicated that they will analyze the results further. tabs., 12 figs.

2000-07-01

413

Blind Adaptive Subcarrier Combining Technique for MC-CDMA Receiver in Mobile Rayleigh Channel  

CERN Document Server

A new subcarrier combining technique is proposed for MC -CDMA receiver in mobile Rayleigh fading channel. It exploits the structure formed by repeating spreading sequences of users on different subcarriers to simultaneously suppress multiple access interference (MAI) and provide implicit channel tracking without any knowledge of the channel amplitudes or training sequences. This is achieved by adaptively weighting each subcarrier in each symbol period by employing a simple gradient descent algorithm to meet the constant modulus (CM) criterion with judicious selection of step-size. Improved BER and user capacity performance are shown with similar complexity in order of O(N) compared with conventional maximum ratio combining and equal gain combining techniques even under high channel Doppler rates.

2011-01-01

414

Bilateral brachial pull-through technique for stenting in a patient with stenosis of the vertebral artery origin: technical case report  

International Nuclear Information System (INIS)

Stenting for stenosis of the proximal vertebral artery (VA) is commonly performed via a femoral approach. However, iliofemoral occlusive disease such as arteriosclerosis obliterans sometimes prevents safe transfemoral access. In certain situations where both femoral access and ipsilateral brachial access are difficult because of a concomitant vascular diseases or particular anatomic setting, a contralateral brachial approach using the brachiobrachial pull-through technique may allow efficient and accurate stenting. A case of VA origin symptomatic stenosis successfully treated with stenting using the new pull-through technique from the contralateral brachial artery to the brachial artery on the affected side is described. (orig.)

2007-10-01

415

Application of probabilistic methods to accident analysis at waste management facilities  

International Nuclear Information System (INIS)

Probabilistic risk assessment is a technique used to systematically analyze complex technical systems, such as nuclear waste management facilities, in order to identify and measure their public health, environmental, and economic risks. Probabilistic techniques have been utilized at the Waste Isolation Pilot Plant (WIPP) near Carlsbad, New Mexico, to evaluate the probability of a catastrophic waste hoist accident. A probability model was developed to represent the hoisting system, and fault trees were constructed to identify potential sequences of events that could result in a hoist accident. Quantification of the fault trees using statistics compiled by the Mine Safety and Health Administration (MSHA) indicated that the annual probability of a catastrophic hoist accident at WIPP is less than one in 60 million. This result allowed classification of a catastrophic hoist accident as ''not credible'' at WIPP per DOE definition. Potential uses of ...

416

Analysis of nonisothermal injection and falloff tests in layered reservoirs  

Energy Technology Data Exchange (ETDEWEB)

The effects of reservoir layering and gravity segregation on nonisothermal injection and falloff tests are investigated. Results show that layering does not affect injection or falloff data if all the layers are permeable and accept fluids from the wellbore. In such cases, the average permeability, skin factor, and distance to the thermal front can be calculated using the techniques developed for homogeneous reservoirs. Special considerations have to be taken for cases where several layers are impermeable or are permeable but do not accept fluids of the well face. In the first case (impermeable layers), knowledge of the total thickness of the permeable layers is required for the existing techniques to be applied successfully. In the second case, the existing techniques cannot be applied, but characteristic responses from injection and falloff test are seen; therefore, this case can be identified easily. 13 refs., 8 figs.

1985-03-01

417

An adaptive synchronous generator stabilizer design by generalized multivariable pole shifting (GMPS) technique  

Energy Technology Data Exchange (ETDEWEB)

A robust adaptive Power System Stabilizer algorithm using a Generalized Multivariable Pole Shifting (GMPS) technique is presented in this paper. The algorithm handles systems with equal or unequal numbers of inputs and outputs, therefore both shaft speed as well as the generator power are used to derive the stabilizing control. The technique also provides a simple scheme of on-line self-searching pole shifting factor to meet the excitation control limits. The application of the proposed stabilizer to a simulated generator excitation control under a wide range of operating and disturbance conditions demonstrates that the new control strategy is superior to conventional Power System Stabilizer (PSS) and the widely accepted Minimum Variance Self-Tuning Controller (MVSTC).

1992-08-01

418

Advances in Modeling of Scanning Charged-Particle-Microscopy Images  

CERN Document Server

Modeling artificial scanning electron microscope (SEM) and scanning ion microscope images has recently become important. This is because of the need to provide repeatable images with a priori determined parameters. Modeled artificial images are highly useful in the evaluation of new imaging and metrological techniques, like image-sharpness calculation, or drift-corrected image composition (DCIC). Originally, the NIST-developed artificial image generator was designed only to produce the SEM images of gold-on-carbon resolution sample for image-sharpness evaluation. Since then, the new improved version of the software was written in C++ programming language and is in the Public Domain. The current version of the software can generate arbitrary samples, any drift function, and many other features. This work describes scanning in charged-particle microscopes, which is applied both in the artificial image generator and the DCIC technique. As an ...

2010-01-01

419

A Study on Feature Selection Techniques in Educational Data Mining  

CERN Document Server

Educational data mining (EDM) is a new growing research area and the essence of data mining concepts are used in the educational field for the purpose of extracting useful information on the behaviors of students in the learning process. In this EDM, feature selection is to be made for the generation of subset of candidate variables. As the feature selection influences the predictive accuracy of any performance model, it is essential to study elaborately the effectiveness of student performance model in connection with feature selection techniques. In this connection, the present study is devoted not only to investigate the most relevant subset features with minimum cardinality for achieving high predictive performance by adopting various filtered feature selection techniques in data mining but also to evaluate the goodness of subsets with different cardinalities and the quality of six filtered feature selection algorithms in terms of F-measure ...

2009-01-01

420

Z-Plasty Made Simple  

UK PubMed Central (United Kingdom)

A Z-plasty is a critical and reliable technique that is useful for scar revisions and correction of free margin distortion. A Z-plasty can help lengthen a contracted scar, change the direction of a...Full Text Available

2010-01-01

421

Wound ballistics: the management of assault rifle injuries.  

Science.gov (United States)

Studies in our wound ballistics laboratory have shown that excellent healing can occur in complicated assault rifle wounds that are free of tension and well drained. A conservative approach to debridement and excision of tissue in uncomplicated extremity wounds may be a valid and resource-saving technique. PMID:2366941

1990-05-01

422

Waterjet Techniques for Composite Material Jet Engine ...  

Science.gov (United States)

Page 1. Page 2. Page 3. Page 4. Page 5. Page 6. Page 7. Page 8. Page 9. Page 10. Page 11. Page 12. Page 13. Page 14. Page 15. Page 16. Page ...

1996-06-01

423

Using support vector machines in the multivariate state estimation technique  

Energy Technology Data Exchange (ETDEWEB)

One approach to validate nuclear power plant (NPP) signals makes use of pattern recognition techniques. This approach often assumes that there is a set of signal prototypes that are continuously compared with the actual sensor signals. These signal prototypes are often computed based on empirical models with little or no knowledge about physical processes. A common problem of all data-based models is their limited ability to make predictions on the basis of available training data. Another problem is related to suboptimal training algorithms. Both of these potential shortcomings with conventional approaches to signal validation and sensor operability validation are successfully resolved by adopting a recently proposed learning paradigm called the support vector machine (SVM). The work presented here is a novel application of SVM for data-based modeling of system state variables in an NPP, integrated with a nonlinear, nonparametric technique ...

1999-07-01

424

Use of solid state nuclear track detectors for radon concentration measurements indoors  

International Nuclear Information System (INIS)

An indoor radioactive survey is being conducted in an Italian district. Preliminary results identified a zone with significant radioactive levels, in which a new specific survey has been planned. In this paper attention is dedicated mainly to radon measurement technique and results.

425

The scattering amplitude for four off-shell tachyons from functional integrals  

International Nuclear Information System (INIS)

We use functional integral techniques to calculate the scattering amplitude for four open off-shell tachyons in Witten's string field theory and show that the residues of the first three poles agree with those obtained using oscillator methods. (orig.).

426

The impact of avoidable mortality on life expectancy at birth in Spain: changes between three periods, from 1987 to 2001  

UK PubMed Central (United Kingdom)

Objective:To evaluate the impact of avoidable mortality on the changes in life expectancy at birth in Spain.Methods:Standard life table techniques...Full Text Available

2008-09-01

427

The CORONIS Trial. International study of caesarean section surgical techniques: a randomised fractional, factorial trial  

UK PubMed Central (United Kingdom)

BackgroundCaesarean section is one of the most commonly performed operations on women throughout the world. Rates have increased in recent years – about 20–25% in...Full Text Available

428

Survival of Genetically Modified and Self-Cloned Strains of Commercial Baker's Yeast in Simulated Natural Environments: Environmental Risk Assessment  

UK PubMed Central (United Kingdom)

Although genetic engineering techniques for baker's yeast might improve the yeast's fermentation characteristics, the lack of scientific data on the survival of such strains in natural environments...Full Text Available

2005-11-01

429

Spectroscopic ellipsometry and polarimetry for materials and systems analysis at the nanometer scale: state-of-the-art, potential, and perspectives  

UK PubMed Central (United Kingdom)

This paper discusses the fundamentals, applications, potential, limitations, and future perspectives of polarized light reflection techniques for the characterization of materials and related systems...Full Text Available

2009-10-01

430

Solution structure of two molecular motor domains: nonclaret disjunctional and kinesin.  

UK PubMed Central (United Kingdom)

The effects of selected ligands on the structure of the truncated heavy-chain chemomechanical motor domains of Drosophila ncd and human kinesin were compared using the technique of transient electric...Full Text Available

1995-04-01

431

Simulation of electron beam therapy employing cone collimation  

Energy Technology Data Exchange (ETDEWEB)

A simple device is described which is used to determine treatment distance and beam direction in electron therapy employing one collimation. A technique for the production of irregular field templates and localization films is given.

1983-07-01

432

Shedding New Light on Early Caries Detection  

UK PubMed Central (United Kingdom)

Dental caries continues to be a common chronic disease among various population groups. Patient care can be improved with detection at the earliest stage. However, current techniques do not...Full Text Available

2008-12-01

433

Scattering amplitude for four off-shell tachyons from functional integrals  

Energy Technology Data Exchange (ETDEWEB)

We use functional integral techniques to calculate the scattering amplitude for four open off-shell tachyons in Witten's string field theory and show that the residues of the first three poles agree with those obtained using oscillator methods.

1988-05-30

434

Risk management in design engineering bids  

Energy Technology Data Exchange (ETDEWEB)

Accurate engineering cost estimates are critical in developing bids for new work, and for effective resource allocation and project control. This study reports on design estimating methods found in the literature, and on the results of two empirical studies of how estimating techniques are used in professional practice and their accuracy. The study found great reliance on a classic {open_quotes}activity analysis{close_quotes} approach to estimating design resources, and significant hazards in commonly used parametric techniques. The study found that project managers expect their estimates to be accurate (with 80% confidence interval) of between -10% to +25%. The study also found that actual bids between engineering firms had a much greater range (-40% to +45%) than can be explained by accuracy. Perhaps most importantly the study found that none of the sampled design firms used probabilistic techniques to optimize their ...

1995-06-01

435

Ring opening reaction dynamics of a photochromic diarylethene derivative dye  

International Nuclear Information System (INIS)

Ring opening dynamics of diarylethene derivative (BTF6) in n-hexane are studied by femtosecond transient absorption and time resolved spontaneous fluorescence techniques. Cyclo-reversion time constant is obtained.

2001-11-01

436

Rapid technique of DNA-DNA in situ hybridisation on formalin fixed tissue sections using microwave irradiation.  

UK PubMed Central (United Kingdom)

The relative sensitivities of different protocols for detecting cytomegalovirus nucleic acid sequences in histological specimens, using a biotinylated cDNA probe, were assessed. Several commonly used...Full Text Available

1987-08-01

437

Rapid isolation and identification of group B streptococci from selective broth medium by slide co-agglutination test.  

UK PubMed Central (United Kingdom)

Direct identification of group B streptococci from a selective broth medium was performed with the Phadebact streptococcus test to determine the feasibility of this technique for early detection of...Full Text Available

1978-10-01

438

Proteomic patterns analysis with multivariate calculations as a promising tool for prompt differentiation of early stage lung tissue with cancer and unchanged tissue material  

UK PubMed Central (United Kingdom)

BackgroundLung cancer diagnosis in tissue material with commonly used histological techniques is sometimes inconvenient and in a number of cases leads to ambiguous conclusions. Frequently...Full Text Available

439

Program Solicitation  

Science.gov (United States)

Technologies for materials, processes, and manufacturing that will provide safe, .... advanced energy conversion techniques, and pulsed inductive and ... duration antimatter storage and transportation, and methods for utilizing ...... EVA systems can be found in the EVA Technology Roadmap of the EVA Project Plan. ...

440

Pressure Probe Technique for Measuring Water Relations of Cells in Higher Plants 1  

UK PubMed Central (United Kingdom)

A new method is described for continuously measuring cell turgor pressure (P), hydraulic conductivity (Lp), and volumetric elastic modulus (ε) in higher plant cells, using a pressure...Full Text Available

1978-02-01

441

PREVENTING TOBACCO USE AMONG YOUNG PEOPLE  

UK PubMed Central (United Kingdom)

Preventing tobacco use in youths may be an easier task than helping adults break the habit of smoking and overcome its ill effects. Using experimental procedures based on social work techniques,...Full Text Available

1986-01-01

442

Osmotically Induced Removal of Water from Fungal Cells as Determined by a Spin Probe Technique 1  

UK PubMed Central (United Kingdom)

Effects of physical environment on plasma membrane semipermeability and osmotic induction of changes in aqueous cytoplasmic volume were studied in vegetative and spore cells of a plant pathogenic fungus,...Full Text Available

1978-11-01

443

Optical diagnostics for turbulent and multiphase flows: Particle image velocimetry and photorefractive optics  

Energy Technology Data Exchange (ETDEWEB)

This report summarizes the work performed under the Sandia Laboratory Directed Research and Development (LDRD) project ``Optical Diagnostics for Turbulent and Multiphase Flows.`` Advanced optical diagnostics have been investigated and developed for flow field measurements, including capabilities for measurement in turbulent, multiphase, and heated flows. Particle Image Velocimetry (PIV) includes several techniques for measurement of instantaneous flow field velocities and associated turbulence quantities. Nonlinear photorefractive optical materials have been investigated for the possibility of measuring turbulence quantities (turbulent spectrum) more directly. The two-dimensional PIV techniques developed under this LDRD were shown to work well, and were compared with more traditional laser Doppler velocimetry (LDV). Three-dimensional PIV techniques were developed and tested, but due to several experimental difficulties were ...

1997-01-01

444

Obtaining a contact lens acquired electroretinogram in the presence of topical anesthetic hypersensitivity.  

Science.gov (United States)

Clinical circumstances often demand flexibility in electrodiagnostic procedures. We present a clinical case that required alteration of our routine full-field electroretinography technique. The patient presented with reports of allergy to Xylocaine (lidocaine) and refused the use of any type of topical anesthetic drops. This conflicted with our routine ERG method that combines the use of the Henkes Lovac hard contact lens and the topical anesthetic Alcaine (proparacaine hydrochloride). We acquired a successful electroretinogram without topical anesthesia by using a "piggy-back" system involving the interposition of a soft hydrophilic contact lens between the cornea and the recording hard lens. The procedure yielded excellent ERG recordings and was well tolerated. This non-routine technique was also compared to our standard ERG technique using a normal volunteer. It appears that this proposed "piggy-back" ...

2007-11-06

445

ON NATIONAL AEROIUWICS AND SPACE ADMINISTRATION TEMPE, ARIZOXA  

Science.gov (United States)

ful application of the network technique, GERT, to the analysis of a terminal ... GERT Networks, Mr. David Gallagher-The Use of GERT in Studying Queueing Problems, ... Smith, R. L., "Stochastic Analysis of Personnel Movement in Formal ...

446

Numerical Weather Prediction Activities Report.  

Science.gov (United States)

This report presents a summary of highlights of the year 1978. It then discusses: Research and development in numerical analysis and prediction systems; Techniques, development and application of new products; Analysis-forecast systems in operation use du...

1978-01-01

447

Network security defence methods in IHEP  

International Nuclear Information System (INIS)

This article is about the network security defence method and technique at IHEP. Including: the experience, research result and application in network outlet security, server security, local network security, network security monitoring and collecting evidence, anti-virus etc

2002-12-01

448

Near-infrared spectroscopy technique to evaluate the effects of red blood cell transfusion on tissue oxygenation  

UK PubMed Central (United Kingdom)

IntroductionThe aim of this study was to evaluate the effects of red blood cell (RBC) transfusions on muscle tissue oxygenation, oxygen metabolism and microvascular reactivity in...Full Text Available

2009-01-01

449

Name of Presentation!  

Wastenet

Up-flow anaerobic attached-growth bioreactors filled with pre-treated coir fibres ...coir-fibre arranged in bottle-brush configuration bounded by a novel plastic binding technique ...-three anaerobic filter reactors in series -coir fibre as the bacteria growth media a sedimentation

450

MudPIT Analysis: Application to Human Heart Tissue  

UK PubMed Central (United Kingdom)

Although two-dimensional polyacrylamide gel electrophoresis (2D-PAGE) has been used as the standard proteomic approach for separating proteins in a complex mixture, this technique has many drawbacks....Full Text Available

2009-01-01

451

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Science.gov (United States)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the ...

1992-08-01

452

Mercury modeling for PWSCC length sizing. [Primary water stress corrosion cracking  

Energy Technology Data Exchange (ETDEWEB)

This report describes the results of EPRI Program S404-28, titled Experimental Modeling of Eddy Current Response'', conducted by the Westinghouse Science and Technology Center (STC). The Westinghouse STC demonstrates that its mercury modeling technique provides an unique bridge between steam generator eddy current field inspection conditions and predictions obtained using recently developed analytical models. The mercury modeling technique was used systematically to explore factors which contribute to primary water stress corrosion cracking (PWSCC) sizing inaccuracy, including probe design, coil excitation frequency, crack length, and crack morphology. Two new proposed techniques for inverting crack lengths from eddy current data are compared with the technique commonly used in field data analysis for PWSCC. The performance of uniform field eddy current probes is compared with the ...

1992-08-01

453

Lung diffusing capacity in a hyperbaric environment: assessment by a rebreathing technique.  

UK PubMed Central (United Kingdom)

A rebreathing method was developed for measuring diffusing lung capacity for carbon monoxide (DLCO) in a hyperbaric environment. Twenty two professional naval divers with normal lung function were included...Full Text Available

1992-04-01

454

Laser-assisted solar-cell metallization processing  

Energy Technology Data Exchange (ETDEWEB)

Laser assisted solar cell metallization processing which is a one step process is examined. The potential advantages of laser disposition techniques for photovoltaic systems are: a high resolution, no photolithography, clean and contamination free, in-situ sintering, and low contact resistance.

1984-03-01

455

Laser-assisted solar cell metallization processing. Quarterly Report, December 1984-February 1985  

Energy Technology Data Exchange (ETDEWEB)

Laser-assisted processing techniques for producing high-quality solar cell metallization patterns are being investigated, developed, and characterized. The tasks comprising these investigations are outlined.

1985-04-01

456

Interaction of the New Ketolide ABT-773 (Cethromycin) with Human Polymorphonuclear Neutrophils and the Phagocytic Cell Line PLB-985 In Vitro  

UK PubMed Central (United Kingdom)

A classical velocity centrifugation technique was used to study the in vitro uptake of the new ketolide ABT-773 by human polymorphonuclear neutrophils (PMNs) and a myelomonoblastic cell line, PLB-985,...Full Text Available

2004-04-01

457

In vivo study of chloroplast volume regulation.  

UK PubMed Central (United Kingdom)

This paper describes a new technique that can be used to study chloroplast volume regulation in vivo. Nuclear magnetic resonance spectroscopy was used to measure relative amounts of chloroplast water...Full Text Available

1992-05-01

458

Improved Susceptibility Disk Assay Method Employing an Agar Overlay Technique  

UK PubMed Central (United Kingdom)

Susceptibility disks impregnated with 35 different antibiotics were assayed by the current Code of Federal Regulations method and by a new method employing an agar overlay. The new...Full Text Available

1978-11-01

459

High-Throughput Screen for Poly-3-Hydroxybutyrate in Escherichia coli and Synechocystis sp. Strain PCC6803  

UK PubMed Central (United Kingdom)

A novel, quantitative method for detecting poly-3-hydroxybutyrate (PHB) amounts in viable cells was developed to allow for high-throughput screening of mutant libraries. The staining technique was demonstrated...Full Text Available

2006-05-01

460

Global Environmental Data for Mapping Infectious Disease Distribution  

UK PubMed Central (United Kingdom)

This contribution documents the satellite data archives, data processing methods and temporal Fourier analysis (TFA) techniques used to create the remotely sensed datasets on the DVD distributed...Full Text Available

2006-01-01

461

Gene expression analysis of interferon ? in laser capture microdissected cervical epithelium  

UK PubMed Central (United Kingdom)

Optimal sample handling techniques for tissue preparation and storage, RNA extraction and quantification, and target gene detection are crucial for reliable gene expression analysis. Methods...Full Text Available

2008-10-01

462

Force-dependent chemical kinetics of disulfide bond reduction observed with single-molecule techniques  

UK PubMed Central (United Kingdom)

The mechanism by which mechanical force regulates the kinetics of a chemical reaction is unknown. Here, we use single-molecule force–clamp spectroscopy and protein engineering to study the effect...Full Text Available

2006-05-09

463

Fixation Techniques for Split Anterior Tibialis Transfer in Spastic Equinovarus Feet  

UK PubMed Central (United Kingdom)

Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of...Full Text Available

2008-10-01

464

Fixation Techniques for Split Anterior Tibialis Transfer in Spastic Equinovarus Feet  

Science.gov (United States)

Equinovarus of the foot is the most common lower extremity deformity following traumatic brain injury. We evaluated outcomes of the split anterior tibialis tendon transfer (SPLATT) for correction of equinovarus in 47 patients with hemiplegic traumatic brain injury and specifically studied differences in outcomes with two tendon fixation techniques. Seventeen patients constituting Group I underwent fixation with one technique and 30 constituting Group II had another technique. Patients in both groups had appropriate procedures based on dynamic electromyography and gait analyses. Both groups were demographically comparable. All 47 feet were corrected to plantigrade position. Thirty-six of 47 patients became brace-free at final followup. There was a notable decrease in the use of ambulatory aids and ambulatory status improved in both groups. There were three fixation-related complications in Group I and none in Group II. ...

2008-01-01

465

Fiscal 1998 industrial science and technology R and D project. Research report on R and D of genome informatics technology (Development of stable oil supply measures using complex biosystem); 1998 nendo genome informatics gijutsu kenkyu kaihtsu seika hokokusho. Fukugo seibutsukei riyo sekiyu antei kyokyu taisaku kaihatsu  

Energy Technology Data Exchange (ETDEWEB)

This report describes the fiscal 1998 result on development of genome informatics technology. As comparative analysis technique of genes, the combination of electrophoresis and PCR was used. For improvement of the throughput and reproducibility of the technique, module- shuffling primers were used, and the multi(96)-arrayed capillary fragment analyzer was devised. The system detecting SNPs rapidly was also developed successfully. As analysis technology of DNA sequence by use of triple- stranded DNA formation, study was made on construction of long cDNA libraries, selective subtraction of specific sequences from libraries, and the basic technology of homologous cloning. Study was also made on each reaction step of IGCR technique for fast analysis, and specifications of a fluorescence transfer monitor. As modeling technique of genetic sequence information, the simulation model was developed for gene ...

1999-03-01

466

Fetal tissue sampling--indications, techniques, complications, and experience with sampling of fetal skin, liver, and muscle.  

UK PubMed Central (United Kingdom)

Invasive prenatal testing has become an important way to evaluate fetuses at increased risk for hereditary disorders. In utero sampling of fetal skin, liver, and muscle may be required to diagnose before-birth...Full Text Available

1993-09-01

467

Experimental Differential Light-Scattering Correction to the Circular Dichroism of Bacteriophage T2  

UK PubMed Central (United Kingdom)

Experimental techniques are presented that can be used to assay and correct for differential light scattering effects in circular dichroism spectra of biological macrostructures. The assay is based...Full Text Available

1973-01-01

468

Evidence for the Regulation of Phytochrome-mediated Processes in Bean Roots by the Neurohumor, Acetylcholine 1  

UK PubMed Central (United Kingdom)

Using pharmacological and chromatographic techniques, it was shown that acetylcholine was present in all organs of both light- and dark-grown mung bean seedings (Phaseolus aureus)....Full Text Available

1970-12-01

469

Environmental and yield aspects of heat provision  

International Nuclear Information System (INIS)

The advantages of district heating as an environmental-friendly and energy-saving technique are reviewed. The role of district heating as part of the Dutch national plan to reduce the emission of acidification and greenhouse gases by respectively 50 and 25 percent is clarified. 12 Tabs. (A.S.).

1994-01-01

470

Electrochemical properties of passive films on 440C stainless steel. Ph. D. Thesis  

Energy Technology Data Exchange (ETDEWEB)

Type 440C stainless steel is a high-C, high-Cr martensitic steel used in applications requiring high hardness and wear resistance in combination with moderate corrosion resistance. Typical applications include precision aerospace bearings and critical components in computer disk drives. The properties of passive films formed on 440C steel were investigated using advanced electrochemical techniques with a view to establishing a method to measure film stability directly in the passivation baths. Electrochemical measurements were sensitive to the passive film properties and were able to quantify the effect of cooling rate on passive film stability. The techniques used included linear polarization, AC impedance, small amplitude cyclic voltammetry, and coulostatic transient measurements. These provided results that exhibited excellent agreement with the AC impedance technique providing the most information about the interfacial ...

1990-10-01

471

Effect of atypical antibiotic resistance on microorganism identification by pattern recognition.  

UK PubMed Central (United Kingdom)

We classified microorganisms from the clinical laboratory by using information provided by the Gram stain and antibiotic sensitivity profiles obtained with the Bauer-Kirby technique. Approximately 4,000...Full Text Available

1978-12-01

472

Edge filter and fringe imaging for laser Doppler wind speed measurement  

Science.gov (United States)

Optical measurement of the Doppler shift of laser backscatter, using a near-IR, visible, or ultraviolet laser, is potentially more robust and field reliable than coherent, heterodyne measurement with an IR laser. The direct measurement of the displacement of Fabry-Perot interference fringes is possible, but entails expensive, technically challenging, imaging detectors. The 'edge technique' permits Doppler shift measurements with relatively simple detectors and detector electronics, and has been implemented with Fabry-Perot etalons and with atomic line filters. Simple analytical models of the fringe imaging and edge detection techniques are presented, permitting ready calculation of the potential performance of either, for various atmospheric conditions and for various lidar hardware configurations. The predictions of the analytical models are confirmed by computer models, which in turn allow more detailed considerations of complicating factors ...

1997-08-01

473

ESTIMATION OF WATER QUALITY CRITERIA VIOLATION FREQUENCIES USING PEARSON PERCENTILES  

Science.gov (United States)

A numerical technique is developed for estimating water quality violation frequencies due to pollutant discharges from urban areas during combined sewer overflow events. The first four moments of in-stream pollutant concentration are found by integrating a pollutant loading - wat...

474

Doppler imaging using spectrally-encoded endoscopy  

UK PubMed Central (United Kingdom)

The capability to image tissue motion such as blood flow through an endoscope could have many applications in medicine. Spectrally encoded endoscopy (SEE) is a recently introduced technique...Full Text Available

2008-09-15

475

Direct filtration for recovery of Schistosoma mansoni cercariae in the field  

UK PubMed Central (United Kingdom)

The recovery of schistosome cercariae from natural waters has been limited by variations in turbidity and in the accuracy of recovery with different techniques. A modification of the Rowan vacuum paper...Full Text Available

1973-01-01

476

Detrended Fluctuation Analysis of Intracranial Pressure Predicts Outcome Following Traumatic Brain Injury  

UK PubMed Central (United Kingdom)

Detrended fluctuation analysis (DFA) is a recently developed technique suitable for describing scaling behavior of variability in physiological signals. The purpose of this study is to explore...Full Text Available

2008-11-01

477

Design of Composite Structures for Reliability and Damage Tolerance.  

Science.gov (United States)

A summary of research conducted during the first year is presented. The research objectives were sought by conducting two tasks: (1) investigation of probabilistic design techniques for reliability-based design of composite sandwich panels, and (2) examin...

1999-01-01

478

Current status and future plan of JMTR Hot Laboratory  

Energy Technology Data Exchange (ETDEWEB)

The newly developed techniques by the Hot Laboratory (JMTR HL) have provided for us the key information on behavior of specimens due to mechanical / physical / chemical / synergistic effects of radiation, stress and water for fission and fusion reactor environment. These techniques are focused on several topics as follows; (1) miniaturized specimen test for the development of fusion reactor materials, (2) slow strain rate tensile testing (SSRT) and crack propagation measuring tests for the study of Irradiation Assisted Stress Corrosion Cracking (IASCC) of core internals of LWR, (3) handling technique on specimens including tritium for the research and development of tritium breeders and neutron multiplier as fusion blanket materials, (4) joining method using the Tungsten Inert Gas (TIG) welding technique for re-assembling of capsule and re-fabrication of specimen and (5) nondestructive evaluation using ...

1999-08-01

479

Concurrent schedule control of human visual target fixations1  

UK PubMed Central (United Kingdom)

Operant conditioning techniques were applied to the study of how target fixations are controlled by the probability of signal occurrence. In a standard vigilance setting, gaze at three illuminable...Full Text Available

1973-11-01

480

Characteristics of fuel oils by thermogravimetry  

Energy Technology Data Exchange (ETDEWEB)

The techniques of thermogravimetry and derivative thermogravimetry (dTG) have been applied to a range of fuel oils and two 'fingerprinting' tests have been developed, one using an inert and the other an oxidizing atmosphere. These tests have been named evaporation profile and burning profile. 4 refs.

1981-12-01

481

Chalk Point Cooling Tower Project: Drift Salinity Experiments.  

Science.gov (United States)

Results of feasibility experiments for determining the mineral content of individual stains on special Sensitized Paper are presented. The stains were formed on the paper by the impaction of laboratory generated salt water droplets. Of the techniques exam...

1979-01-01

482

Cerebral scintigraphy--the phoenix rises again.  

UK PubMed Central (United Kingdom)

This paper reviews the development of cerebral scintigraphy from its early days of planar imaging with simple technetium-99m labelled compounds to the recent revival of the technique in the form of...Full Text Available

1988-01-01

483

Camouflage Dispenser, Helicopter Mounted.  

Science.gov (United States)

New and improved camouflage techniques which will enhance field security are required by Department of Army personnel. The report contains the results of tests, formulations and the operational characteristics of the 73E01-1A dispenser. Various tests (air...

1972-01-01

484

Atmospheric electrodynamics in the U. S. - 1987-1990  

Energy Technology Data Exchange (ETDEWEB)

Atmospheric electrodynamics research is summarized, focusing on three general areas: the ionosphere as a source for middle atmospheric electrodynamics, regional and global scale electrodynamics, and thunderstorms and lightning. New or improved instrumentation techniques which have furthered atmospheric electrodynamics research are also discussed. 93 refs.

1991-01-01

485

Assessment of structural changes of human teeth by low-field nuclear magnetic resonance (NMR)  

UK PubMed Central (United Kingdom)

A technique of low-field pulsed proton nuclear magnetic resonance (NMR) spin relaxation is described for assessment of age-related structural changes (dentin and pulp) of human teeth in...Full Text Available

2010-01-01

486

Assessment of four serological techniques in the immunological diagnosis of farmers' lung disease.  

Science.gov (United States)

Farmers' lung disease (FLD) is a pulmonary disease that results from repeated inhalation of antigens from mouldy hay or straw. The objective of this prospective study was to assess the reliability of four serological techniques in FLD diagnosis. Sera from 15 consecutive patients with FLD, 15 healthy control farmers and 30 urban controls were analysed using four serological techniques [electrosyneresis (ES), Ouchterlony double diffusion (DD), ELISA and Western blot (WB)] with four antigens (Absidia corymbifera, Eurotium amstelodami, Wallemia sebi and Saccharopolyspora rectivirgula). In the authors' region, ES on cellulose acetate with A. corymbifera antigen was the most relevant diagnostic tool for discriminating FLD patients from healthy exposed farmers (sensitivity 87 %, specificity 100 %). DD tests were in accordance with ES, but their discriminatory power was lower. No threshold indicating both good sensitivity and specificity could be ...

2007-10-01

487

Applying Direct Observation to Model Workflow and Assess Adoption  

UK PubMed Central (United Kingdom)

Lack of understanding about workflow can impair health IT system adoption. Observational techniques can provide valuable information about clinical workflow. A pilot study using direct observation was...Full Text Available

2006-01-01

488

Application of spectroscopic techniques for the study of paper documents: A survey  

International Nuclear Information System (INIS)

For many centuries paper was the main material for recording cultural achievements all over the world. Paper is mostly made from cellulose with small amounts of organic and inorganic additives, which allow its identification and characterization and may also contribute to its degradation. Prior to 1850, paper was made entirely from rags, using hemp, flax and cotton fibres. After this period, due to the enormous increase in demand, wood pulp began to be commonly used as raw material, resulting in rapid degradation of paper. Spectroscopic techniques represent one of the most powerful tools to investigate the constituents of paper documents in order to establish its identification and its state of degradation. This review describes the application of selected spectroscopic techniques used for paper characterization and conservation. The spectroscopic techniques that have been used and will be reviewed include: ...

2009-06-01

489

Annealing behavior of radiation damages in metal-silicides  

International Nuclear Information System (INIS)

The annealing behavior of the radiation damage in epitaxial Pd_2Si and NiSi_2 films on Si, due to the implantation of 100 keV Ar ions, is investigated by using the channeling technique with "4He ions. (U.K.).

490

Anion-exchange extraction of cephapirin, cefotaxime, and cefoxitin from serum for liquid chromatography.  

UK PubMed Central (United Kingdom)

An anion-exchange column technique for extraction of antibiotics from serum proteins has been developed for use in the assay of cephapirin, cefotaxime, and cefoxitin by high-pressure liquid chromatography....Full Text Available

1982-04-01

491

An investigation of enzootic Glasser's disease in a specific-pathogen-free grower-finisher facility using restriction endonuclease analysis  

UK PubMed Central (United Kingdom)

Enzootic Glassers's disease was investigated to study the epidemiology of the disease strains on a farm where it presented a problem. Restriction endonuclease fingerprinting (REF) analysis technique...Full Text Available

1993-08-01

492

An improved method for undertaking limiting dilution assays for in vitro cloning of Plasmodium falciparum parasites  

UK PubMed Central (United Kingdom)

BackgroundObtaining single parasite clones is required for many techniques in malaria research. Cloning by limiting dilution using microscopy-based assessment for parasite growth...Full Text Available

493

An evaluation of the pendulum technique of electron beam therapy  

International Nuclear Information System (INIS)

Electron beam therapy of lesions such as cutaneous metastatic carcinoma and reticulum cell sarcoma is performed via multiple portals for a wide irradiation field. However, the dose distribution in border areas is generally uneven, resulting in hot and cold dose areas depending on the intervals of the portals. We performed electron irradiation by the pendulum technique, especially on curved areas, and evaluated the technique in various respects. Pendulum electron beam irradiation is indicated when the length of the cone must be reduced in order to deliver the target volume near the skin surface as well as to avoid the occurrence of hot spots deep in the body. We prepared a 15cm rotating cone by cutting a 30cm fixed irradiation cone. The modification posed no disadvantages in terms of extent and flatness of the beam, or stability during rotation. After determining the relationship between the rotation speed and the dose, the ...

494

Air shifting diffusion; Diffusion d'air par deplacement  

Energy Technology Data Exchange (ETDEWEB)

The technique of air diffusion by shifting presents several advantages in terms of thermal comfort, indoor air quality and energy conservation. This book presents the principle, dimensioning, and implementation of air shifting diffusion systems. (J.S.)

2001-07-01

495

Adapting developing country epidemiological assessment techniques to improve the quality of health needs assessments in developed countries  

UK PubMed Central (United Kingdom)

BackgroundWe were commissioned to carry out three health assessments in urban areas of Dublin in Ireland. We required an epidemiologically robust method that could collect data rapidly...Full Text Available

496

Acetylcholine receptor kinetics. A description from single-channel currents at snake neuromuscular junctions.  

UK PubMed Central (United Kingdom)

Single-channel currents from acetylcholine receptor channels of garter snake neuromuscular junctions were recorded using the patch-clamp technique. Low concentrations of acetylcholine or carbamylcholine...Full Text Available

1982-09-01

498

AEROSPACE MEDICINE AND BIOLOGY - NASA Technical Reports Server  

Science.gov (United States)

Learning curve models have gained widespread acceptance as a technique for analyzing and ...... flight segment in F4 pilots p 163 A91-30966. WILSON, JOHN W . ...

499

A simple manganous chloride and Congo red disc method for differentiating Neisseria gonorrhoeae from Neisseria meningitidis.  

UK PubMed Central (United Kingdom)

Manganous chloride and Congo red incorporated into blotting paper discs have been used to differentiate gonococci from meningococci. The new technique is simple and reliable; the materials for the test...Full Text Available

1978-10-01

500

'TT ( \\\\ b - NASA Technical Report Server (NTRS)  

Science.gov (United States)

Inertial navigation error propagation. 153. 100. --. 8. GN-5. Hypersonic entry guidance techniques. 150. 100. 0.8. 9. FM-13. Ablation effects on hypersonic ...