WorldWideScience
 
 
1

Redetermination of several half-lives  

International Nuclear Information System (INIS)

The half-lives of "4"1Ar, "8"0"mBr, "9"4"mNb, "1"0"1Mo, "1"0"1Tc, "1"0"9Pd, "1"0"9"mPd, "1"2"2Sb, "1"2"2"mSb, "1"2"3"mSn, "1"5"2"mEu and "2"3"9Np have been measured more accurately compared to previous measurements. All of these half-lives and 39 others published earlier will be cited by M.S. Antony in the forthcoming project 'Chart of the nuclides - Strasbourg, 1990' due to appear early 1991. (author) 34 refs.; 4 figs.; 2 tabs.

2

Purification of radioactive decontamination liquids from NPP Paks with reactive adsorption and ion-exchange process  

International Nuclear Information System (INIS)

In nuclear power plant Paks, Hungary, alkaline oxidative (NaOH, KMnO_4, H_2O) and acidic reductive (citric- and oxalic acid, water) liquids are using for the decontamination of primary circuit equipment (main liquid circulating pumps, steam generators, pipelines etc). The above mentioned decontamination liquids are containing "1"1"0"mAg, "9"5Nb, "5"4Mn, "5"8 Co, "6"0Co, "5"1 Cr, "1"2"4 Sb radioisotopes, summarized radioactivity is between 10"3-8x10"4 kBq/dm"3 liquid. The decontamination liquid can be cleaned with reactive adsorption (active carbon) and ion-exchange process at elevated temperature (333-368 K) in multilayered columns. After purification the summarized radioactivity for "5"4Mn, "6"0Co, and "1"1"0"mAg are in the outlet liquid below 1 kBq/dm"3. Decontamination factor DF#approx =#10"3-10"4, volumetric reduction factor VRF#approx =#50-500.

1999-11-04

3

Safe detection of Co-60. New perspectives in contamination and clearance measurements  

International Nuclear Information System (INIS)

Consistent application of a newly developed coincidence technique to determine activation products in the operation and demolition of nuclear facilities results in very new perspectives in contamination monitoring and clearance measurement of plant components. In particular, it is possible to avoid the critical spread of point-source Co-60 contamination, the so-called hot particles. The CCM (Cobalt Coincidence Measurement) technique includes the coincident detection of prompt-prompt gamma cascades with "6"0Co and other activation products ("1"1"0"mAg, "1"2"4Sb, "2"2Na) with low mass-specific limits for unrestricted clearance. Special features of the technique are the short measurement times, excellent signal-to-noise ratio, and focusing in space achieved. Compared to conventional integral gamma-measurements, the signal-to-background ratio can be improved by 1-2 orders of magnitude. The method can be employed especially where conventional integral or spectroscopic methods suffer from ...

4

ZZ MCB-JEF2.2, MCB Continuous-Energy Neutron Cross Section Libraries for Temperatures from 300 to 1800 K  

International Nuclear Information System (INIS)

1 - Description of program or function: MCB-JEF2.2 is a continuous-energy cross section libraries in ACE Format suitable for the MCB-1C and MCNP codes. Libraries for various materials were generated at six different Temperatures, and cover the energy range up to 20 MeV. Format: ACE. Number of groups: Continuous energy. Nuclides: H-1, H-2, H-3, He-3, He-4, Li-6, Li-7, Be-9, B-10, B-11, C-nat., N-14, N-15, O-16, O-17, Na-23, F-19, Mg-nat., Al-27, Si-nat., P-31, S-32, S-33, S-34, S-36, Cl-nat, K-nat, Ca-nat., Ti-nat, V-nat, Cr-50, Cr-52, Cr-53, Cr-54, Mn-55, Fe-54, Fe-56, Fe-57, Fe-58, Co-59, Ni-58, Ni-59, Ni-60, Ni-61, Ni-62, Ni-64, Cu-nat, Ga-nat, Ge-72, Ge-73, Ge-74, Ge-76, As-75, Se-74, Se-76, Se-77, Se-78, Se-80, Se-82, Br-79, Br-81, Kr-78, Kr-80, Kr-82, Kr-83, Kr-84, Kr-85, Kr-86, Rb-85, Rb-86, Rb-87, Sr-84, Sr-86, Sr-87, Sr-88, Sr-89, Sr-90, Y-89, Y-90, Y-91, Zr-nat, Zr-90, Zr-91, Zr-92, Zr-93, Zr-94, Zr-95, Zr-96, Nb-93, Nb-94, Nb-95, Mo-nat, Mo-92, Mo-94, Mo-95, Mo-96, Mo-97, ...