This paper aims at the study of the transfer and accumulation of "1"0"6Ru from marine foods to man through the grazing food chain and evaluation of the radiation exposure to man. As a model, accumulation and excretion of "1"0"6Ru in mice orally administered by the meat of prawn (Penaeus japonicus) which accumulated the radionuclide from the sea water, were examined and compared with those in mice administered by non-radioactive prawn meat mixed with the contaminant in inorganic chemical forms (the control diet); on the latter experiment, the previous evaluation method of the radiation exposure was based. Higher concentrations of "1"0"6Ru in tissues and organs of mice were observed in the former diet than in the latter because of the higher absorption rate of "1"0"6Ru from the gastrointestinal tract (17.4 +- 4.4%, the control diet: 0.7 +- 0.7%) and smaller excretion. As the results of this experiment, the critical organs for men by ingestion of such a meat should be considered as ...
Feasibility of using fixed bed column of conventional ion exchangers/sorbent and chemical precipitation based processes have been examined for the effective removal of the very low levels of 106Ru activity from NH4NO3 effluent generated during wet processing of rejected sintered depleted uranium fuel pellets. Based on the results, a simple process involving precipitation of cobalt sulphide along with ferric hydroxide was selected and further optimization of process variables was carried out. The optimized process has been found to be highly efficient in reducing 106Ru activity down to extremely low levels.
Ruthenium-106 administered to newborn rats and swine was incorporated into the epithelium of the lower small intestine and retained there for a few weeks after gavage; the stomach and small bowel of guinea pigs incorporated "1"0"6Ru but did not retain it.
ContextMusic and surgery.ObjectiveTo determine the effect of live classical piano music on vital signs of patients undergoing ophthalmic surgery.DesignRetrospective...Full Text Available
PURPOSE: To determine the frequency of ophthalmic abnormalities in patients with cutaneous T-cell lymphoma (mycosis fungoides and Sézary syndrome) and T-cell lymphoma involving the skin and...Full Text Available
Two dogs were given 3.0 mCi/kg body weight of "1"0"6Ru-"1"0"6Rh and two were given 4.0 mCi/kg. At 5 days after treatment, one dog from each dose level was colectomized. The dog given the larger dose but not surgically treated was killed in extremis due to acute lower bowel injury at 18 days. The other dog, given 3.0 mCi/kg but not surgically treated, was killed in a moribund condition at 145 days after dosing. The rectum had perforated. The colectomized dogs recovered from intestinal injury and showed no radiation damage at the termination of the study.
Removal of radioactive ions was studied from low and medium level radioactive waste solutions by electrodialysis using ion exchange membranes. The test solutions contained "1"3"7Cs"+, "1"0"6Ru"3"+ or fission products (F.P.) as active ions and NaCl, Na_2SO_4 or Ca(NO_3)_2 as inactive coexisting salts. The decontamination factor of the active ions was in the order: "1"3"7Cs"+ (greater than 99%) > "9"0Sr"2"+ > F.P. > "1"0"6Ru"3"+. The dialysis time required to attain the saturation was the shortest for monovalent cations K"+, Cs"+ and Na"+, intermediate for divalent cation Sr"2"+, and the longest for trivalent cation Ru"3"+. The ratio of the decontamination factor of an active ion eta sub( a) to the desalination factor of an inactive ion eta sub( b) was nearly equal to unity for "2"4Na, "4"2K, "1"3"7Cs and "9"0Sr. On the other hand, the apparent selective permeability of an active ion (A"+) against Na"+ ion, T sub(Na"+) sup( a) was higher than unity for all the active ions ...
... Secondly, the electrode- tissue interface may have ... stimulation of the optic nerve in a ... Ocular Electronic Vision Prosthesis, Australasian Ophthalmic ...
At the Tokai Research Establishment of Japan Atomic Energy Research Institute, the radioactive solid waste incineration unit with a capacity of 100 kg/h was installed in 1979, since then the unit has been routinly operated. An off-gas cleaning system of the unit consists mainly of a primary and secondary ceramic filters, a heat resistant HEPA filter and a scrubber. A series of hot test was carried out to examine the docontamination performance for radionuclides in the off-gas cleaning system. In the test, simulated wastes contaminated with a known quantity of radionuclides were burned in the unit, and radioactive concentrations in the off-gas were measured. And then, the following data were obtained: a retention factor of radionuclides in a furnace and a decontamination factor for radionuclides in each of off-gas cleaning components. And also overall decontamination factors, defined as the ratio of radioactivities input to the furnace to radioactivities passed through outlet of the ...
A algorithm was developed to determine the characteristic parameters of PWR spent fuel, such as burnup, cooling time and initial enrichment of {sup 235}U by use of gamma-ray activity ratios of {sup 134}Cs/{sup 137}Cs, {sup 154}Eu/{sup 137}Cs and {sup 106}Ru/{sup 137}Cs from the high resolution gamma-ray spectroscopy and ORIGEN-S calculations. For the verification of the method developed, gamma-ray measurements of Kori-1 and Kori-2 nuclear fuel rods were carried out using HPGe gamma ray scanning system. As a results, it is revealed that the measured values are in a good agreement with the operator declared values within the about {+-} 5% errors. Besides, the under-water burnup measuring device has been designed to measure the gamma-ray from the PWR spent fuel assembly. This device will be set up in the pool of Post-Irradiation Examination Facility(PIEF), and used in determination of the average burnup, cooling time and initial enrichment of the ...
PurposeTo report the clinical, ophthalmic, and genetic characteristics for lattice corneal dystrophy type I (LCDI) in a Chilean family.MethodsSix...Full Text Available
The NCRP Wound Model, which describes the retention of selected radionuclides at the site of a contaminated wound and their uptake into the transfer compartment, has been combined with the ICRP element-specific systemic models for those radionuclides to derive dose coefficients for intakes via contaminated wounds. These coefficients can be used to generate derived regulatory guidance (i.e., the activity in a wound that would result in an effective dose of 20 or 50 mSv, or in some cases, a organ-equivalent dose of 500 mSv) and clinical decision guidance (i.e., activity levels that would indicate the need for consideration of medical intervention to remove activity from the wound site, administration of decorporation therapy or both). Data are provided for 38 radionuclides commonly encountered in various activities such as nuclear weapons, fuel fabrication or recycling, waste disposal, medicine, research, and nuclear power. These include 3H, 14C, 32P, 35S, 59Fe, 57,58,60Co, 85,89,90Sr, ...
A series of separation experiment was performed in order to study a multi-functional spent fuel reprocessing process based on ion-exchange technique. The tertiary pyridine-type anion-exchange resin was used in this experiment and the mixed oxide fuel highly irradiated in the experimental fast reactor ''JOYO'' was used as a reference spent fuel. As the result, "1"0"6Ru + "1"2"5Sb, "1"3"7Cs + "1"5"5Eu + "1"4"4Ce, plutonium, americium and curium could be separated from the irradiated fuel by only three steps of ion-exchange. The decontamination factor of "1"3"7Cs and trivalent lanthanides ("1"5"5Eu, "1"4"4Ce) in the final americium product exceeded 3.9 x 10"4 and 1.0 x 10"5, respectively. The decontamination factor for the mutual separation of "2"4"3Cm and "2"4"1Am was larger than 2.2 x 10"3 for the americium product and, moreover, the content of "1"3"7Cs, trivalent lanthanides and "2"4"3Cm included in "2"4"1Am product did not exceed 2 ppm. These results prove that the proposed simplified ...
Purpose To investigate the influence of timolol maleate 0.5% gel-forming solution and brinzolamide 1% ophthalmic suspension on contrast sensitivity, ocular higher-order aberration (HOA), and corneal surface light scattering. Design Prospective, comparative study. Participants Forty normal volunteers were enrolled in this study. Methods We evaluated contrast sensitivity, ocular HOA, and corneal light scattering before and 2, 5, 10, and 15 minutes after instillation of antiglaucoma eyedrops. Contrast sensitivity function was assessed with the CSV-1000RN chart (Vector Vision Co., Greenville, OH). Higher-order aberration was measured for a 4-mm pupil using the Hartmann-Shack aberrometer (KR-9000PW; Topcon, Tokyo, Japan). Corneal surface light scattering was quantitatively evaluated by using th...
An analyzer-based X-ray phase-contrast imaging (ABI) setup has been mounted at the Brazilian Synchrotron Light Laboratory (LNLS) for multiple imaging radiography (MIR) purposes. The algorithm employed for treating the MIR data collected at LNLS is described, and its reliability in extracting the distinct types of contrast that can be obtained with MIR is demonstrated by analyzing a test sample (thin polyamide wire). As a practical application, the possibility of studying ophthalmic tissues, corneal sequestra in this case, via MIR is investigated.
In recent years, several groups, including the physician assistant, health information management, ophthalmic medical technician/technologist, and athletic training review committees, have left the Commission on Accreditation of Allied Health Education Programs (CAAHEP) system to form their own, profession-specific accrediting bodies. Their motivation was typically a desire for greater professional visibility and autonomy. Combined, these professions represented one third of the CAAHEP's programs. This article reviews the history of allied health and examines current attempts to bring cohesion and identity to this increasingly fractured segment of the U.S. health care system. PMID:18444439
Background:- Discrepancies exist in optometric education, practice and regulation across the Asia-Pacific region and the competence of optometric practitioners in adopting new lens technologies may vary widely. Over the past 10-years, a continuing professional development program, Varilux Academy Asia-Pacific (VAAP), was implemented and conducted in countries across the Asia-Pacific region to improve practitioners' understanding of optometric fitting principles, with special emphasis on progressive addition lenses (PAL). The aim was to demonstrate the effectiveness of VAAP and to compare the competence of practitioners across the Asia-Pacific region in new lens fitting technologies. Methods:- From 2002 to 2008, all VAAP participants from 12 countries across Asia-Pacific were invited to com...
We compared the efficacy of timolol maleate ophthalmic gel-forming solution 0.5% QD with that of levobunolol hydrochloride 0.5% BID, as measured by change in intraocular pressure (IOP), effect on heart rate, and ocular tolerability. The study had a positive-controlled, double-masked, randomized, multicenter, 12-week, two-period (6 weeks each), crossover design. One hundred fifty-two patients with open-angle glaucoma or ocular hypertension were randomized to receive either timolol maleate gel-forming solution QD or levobunolol BID for 6 weeks, followed by a crossover to the alternate treatment. IOP and heart rate were measured at morning trough and peak during weeks 3, 6, 9, and 12. Timolol maleate gel-forming solution QD was comparable to levobunolol BID in reducing IOP at peak and trough. Although the effects on peak heart rate were similar between the two medications, the effect on trough heart rate of timolol maleate gel-forming solution QD was significantly ...
Objective: To analyze the early response of uveal melanomas in patients treated with ruthenium-106 brachytherapy. Materials And Methods: In the period between April 2002 and July 2003, 20 patients diagnosed with uveal melanoma were submitted to ruthenium-106 brachytherapy. The calculated dose delivered at the apex of the tumor ranged between 55 Gy and 100 Gy. Patients with lesions greater than 5 mm were submitted to transpupillary thermotherapy concomitantly with ophthalmic plaque insertion. Results: As regards the lesions site, 75% of the lesions were located in the choroid, 15% in the iris, and the remainder 10% in the ciliary body. In a median 19-month-follow-up, the progression-free survival for brachytherapy was 69%, and 87% for associated brachytherapy and transpupillary thermotherapy. A significant tumor height reduction was observed after treatment. No patient was submitted to enucleation. Conclusion: Our preliminary results show that ruthenium-106 ...
PurposeTo evaluate the efficacy of photorefractive keratectomy (PRK) for residual refractive error after penetrating keratoplasty (PKP) for keratoconus. SettingPrivate ophthalmic clinic. DesignCase series. MethodConsecutive patients who had PRK augmented with topical mitomycin-C (MMC) after PKP for keratoconus were retrospectively reviewed. Patients were divided into a a low cylinder group (refractive cylinder 6.00 D). Visual acuity, refraction, and keratometry were analyzed preoperatively and 1, 3, 6, and 12 months postoperatively. ResultsThe study comprised 47 eyes (41 patients). The spherical equivalent (SE) decreased from -4.24 D +- 3.23 (SD) preoperatively to -0.71 +- 1.03 D 12 months postoperatively in the low cylinder group and from -4.19 +- 3.54 D to -2.45 +- 3.42 D, respectively, ...
Clinical circumstances often demand flexibility in electrodiagnostic procedures. We present a clinical case that required alteration of our routine full-field electroretinography technique. The patient presented with reports of allergy to Xylocaine (lidocaine) and refused the use of any type of topical anesthetic drops. This conflicted with our routine ERG method that combines the use of the Henkes Lovac hard contact lens and the topical anesthetic Alcaine (proparacaine hydrochloride). We acquired a successful electroretinogram without topical anesthesia by using a "piggy-back" system involving the interposition of a soft hydrophilic contact lens between the cornea and the recording hard lens. The procedure yielded excellent ERG recordings and was well tolerated. This non-routine technique was also compared to our standard ERG technique using a normal volunteer. It appears that this proposed "piggy-back" technique is a useful alternative to routine ERG procedure in cases of ...
Citation information: Rosenfield M. Computer vision syndrome: a review of ocular causes and potential treatments. Ophthalmic Physiol Opt 2011, 31, 502-515. doi: 10.1111/j.1475-1313.2011.00834.x ABSTRACT: Computer vision syndrome (CVS) is the combination of eye and vision problems associated with the use of computers. In modern western society the use of computers for both vocational and avocational activities is almost universal. However, CVS may have a significant impact not only on visual comfort but also occupational productivity since between 64% and 90% of computer users experience visual symptoms which may include eyestrain, headaches, ocular discomfort, dry eye, diplopia and blurred vision either at near or when looking into the distance after prolonged computer use. This paper reviews the principal ocular causes for this condition, namely oculomotor anomalies and dry eye. Accommodation and vergence responses to electronic screens appear to be similar to ...
Absorption of the excimer laser radiations of 193-nm argon fluorine and 308-nm xenon chloride in balanced salt solution, sodium hyaluronate, and human cadaver eyes was measured. The absorption of these materials as considerably different for the two wavelengths; we found that 308-nm light experienced much less absorption than the 193-nm light. The extinction coefficient (k) for 308 nm was k = 0.19/cm for balanced salt solution and k = 0.22/cm for sodium hyaluronate. In contrast to this, the extinction coefficient for 193 nm was k = 140/cm for balanced salt solution and k = 540/cm for sodium hyaluronate. Two 1-day-old human phakic cadaver eyes showed complete absorption with both wavelengths. Using aphakic eyes, incomplete absorption was noted at the posterior pole with 308 nm and complete absorption was noted with 193 nm. The extinction in the anterior part of aphakic eyes (the first 6 mm) was 4.2/cm for 308 nm, meaning that the intensity of the light is reduced by a factor of 10 after ...