This paper describes the problems and solutions in using 18 MeV linear accelerator, with minimum 6 MeVelectron capability, for total skin irradiation for mycosis fungoides. The 6 MeVelectron energy...Full Text Available
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeVelectron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mevelectrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is ...
This study investigated dose to bone tissue in electron beam therapy. Measurements were made using films and thermoluminescent dosimeters in a polystyrene phantom containing bone inhomogeneity for 15-MeV, 12-MeV, and 9-MeVelectron beams. An increase in dose of approximately 18%, 12%, and 11%, for the three electron energies respectively, relative to the dose in polystyrene, was found for bone material having an electron density (relative to water) of 1.73. Measurements were also made using films for 15- and 9-Mevelectrons in a phantom with a mandibular bone and teeth. A dose enhancement in bone of approximately 10% and 7%, respectively, for the two energies was found in the phantom where the electron density of bone was about 1.60. These results suggest that injury to bone is ...
The performance and characteristics of a medical linear accelerator ''NELAC-1018'' for the electron beam therapy were discussed. Measurement of deep dose distribution revealed that the 80% range was 1.9 cm by 6 MeV, 2.8 cm by 9 MeV, 3.9 cm by 12 MeV, 4.9 cm by 15 MeV and 5.5 cm by 18 MeV. Iso-dose distribution with each tubus and cone showed a favorable flatness by any of the energies. The degree of flatness was extremely favorable, being +-1.7% or less.
By W. Wayne Scott. Langley Research Center. SUMMARY. Thin- and thick-target bremsstrahlung spectra are presented for electron energies up to 7.0 MeV. ...
Ion acceleration has now been demonstrated with the IFA-2 collective ion accelerator system. The IFA-2 system is described, photoionization experiments are summarized, and ion results are presented. Using a 1 MeVelectron beam and a 30 cm acceleration length, IFA-2 has produced 5 MeV H/sup +/, 10 MeV D/sup +/, and 20 MeV He/sup + +/. This means that accelerating fields of 33 MV/m over 30 cm have been achieved with a controlled collective accelerator for the first time.
The spectral energy-dependence of the radiation-induced ESR signal has been studied in ovine cortical bone. Crushed bone samples were irradiated using photon beams with effective energies in the range from 0.06 to 6 MeV, and electron beams with mean energies in the range from 2 to 10 MeV. The photon and electron data were normalized to a dose to bone of 50 Gy and the results are reported as response relative to the ESR signal for photon irradiation at 1.25 MeV ("6"0Co). The photon irradiation results show that the ESR response is greatest at low energies with a relative value of 1.2 at 0.06 MeV. The relative response decreases, as the energy increases, to approximately 0.85 in the region of 2 to 3 MeV. These variations in the relative ESR responses are significantly less than the ESR energy-dependent responses reported in the literature for ...
A variable-dispersion electron spectrometer is being installed for use by the Stanford Superconducting Accelerator in conjunction with its Free Electron Laser program. The system has been designed to operate with electron beam energies from 20 MeV to 200 MeV, with a maximum energy resolution of 0.01% FWHM. The maximum energy acceptance is approximately #+-# 5%, as determined by the bending magnet aperture. Resolution is controlled by adjusting the focal conditions at the entrance to a 90 degree bending magnet, while the dispersion is controlled by changing the magnitude and polarity of the field in a quadrupole magnet which immediately follows the bending magnet. 4 refs., 5 figs.
The electron scattering form factor for excitation of the 1/sup +/ state of /sup 88/Sr at 3.486 MeV has been calculated in the quasiparticle random phase approximation (QRPA). The disagreement between the data and restricted shell-model calculations can be explained in terms of the pairing correlations introduced by the QRPA; no ..delta..-h admixtures are required.
The electron scattering form factor for excitation of the 1"+ state of "8"8Sr at 3.486 MeV has been calculated in the quasiparticle random phase approximation (QRPA). The disagreement between the data and restricted shell-model calculations can be explained in terms of the pairing correlations introduced by the QRPA; no #DELTA#-h admixtures are required. (orig.).
The influence of MeVelectrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.
The influence of MeVelectrons irradiation on the gate oxide layers of hydrogenated polysilicon thin film transistors (TFTs) was investigated by measuring gate leakage currents and threshold voltages. The experimental data revealed a decrease of oxide trap density and increase of positive oxide charge. Improvement in the interface roughness and in the oxide quality near the bottom interface was observed.
The proposal made in this paper refers to a free electron laser FEL with small-period electromagnet undulator in SASE regime and a FEL transverse optical klystron in the amplifier regime. The relativistic electron beam source for this FEL is the 7 MeVelectron linac of the National Institute for Laser, Plasma and Physics Radiation (NILPRP) in Bucharest. The paper presents the main features of the design and performance of both FELs and discusses the improvements which must be made to the accelerator in order to use it as a free electron source concerning the injection system of electrons and formation of accelerated electron beam. The findings show that this FEL can be employed as a coherent radiation source in the IR range. (author)
Minority-carrier lifetime damage coefficients for 1 MeVelectron, 3 MeV proton, and 6 MeV alpha particle irradiation of n-type (4.5{times}10{sup 15} and 1.3{times}10{sup 17}cm{sup {minus}3}) and p-type (2.5{times}10{sup 17}cm{sup {minus}3}) InP have been measured using time-resolved photoluminescence. These values are relatively insensitive to carrier type and show a slight increase with increasing carrier concentration. Evidence of comparable electron and hole capture lifetimes is found for the dominant recombination defect. The effect of 3 MeV proton and 6 MeV alpha particles relative to 1 MeVelectrons is an increase in the lifetime damage coefficient by factors of about 10{sup 4} and 10{sup 5}, respectively. {copyright} {ital 1997 American Institute of Physics.}
The salient features of the near-infrared free-electron laser (FEL) that is under construction at the new Darmstadt superconducting 130-MeVelectron accelerator are discussed. Special attention is given to the layout and the parameters of the accelerator, the layout of the planned FEL experiment, the characteristics of the electron gun, the subharmonic chopper-buncher system, and the hybrid undulator system of the Darmstadt FEL. A comparison of the planned Darmstadt FEL with conventional lasers, with respect to the pulse and wavelength region, is presented. 15 refs.
Using the slow electrons spectrometer one can get information on the surface structure, its element composition, chemical bonds, adsorption phenomena, electron state density and surface oscillation. We have developed the methods and created the apparatus that makes it possible to investigate the electron backscattering by solid surface. We have studied the electron scattering by the polycrystalline and monocrystalline. GaAs surface in the energy range of 0 to 9 eV. The FWHM of electron energy distribution function was 70 meV. (author).
Studies of destruction of very-high-n (100electron model suggests that, for ultralow electron energies (#approx#80 #mu#eV--1.4 meV), the cross section #sigma#(var-epsilon) for rotationally inelastic scattering of electrons by a polar target varies approximately as 1/var-epsilon, where var-epsilon is the electron energy.
Black pepper, white pepper, red pepper, ginger and turmeric were irradiated with 10 MeVelectrons from a linear accelerator to a dose of 100 kGy and radioactivity was measured in order to estimate induced radioactivity in the irradiated foods. Induced radioactivity could not be detected significantly by #gamma#-ray spectrometry in the irradiated samples except for spiked samples which contain some photonuclear target nuclides in the list of photonuclear reactions which could produce radioactivity below 10 MeV. From the amount of observed radioactivities of short-lived photonuclear products in the spiked samples and calculation of H_5_0 according to ICRP Publication 30, it was concluded that the induced radioactivity and its biological effects in the 10 MeVelectron-irradiated natural samples were negligible in comparison with natural radioactivity from "4"0K contained in the ...
The neutron transition multipole moment, M/sub n/, for (0"+#->#2"+, 1.84 MeV) transition is inferred by measuring the (#alpha#,#alpha#') angular distribution at E/sub #alpha#/ = 50 MeV and comparing it with a microscopic distorted-wave Born approximation calculation. Proton transition densities are taken from electron scattering data. M/sub n//M/sub p/ is found to be substantially less than N/Z in agreement with the (p,p') result.
A free-electron laser (FEL) user facility is discussed. The FEL, which will be operated as an oscillator, will be driven by the electron beam of the racetrack microtron (RTM) that is nearing completion. Variation of the electron kinetic energy from 17 MeV to 185 MeV will permit the FEL wavelength to be tuned from 200 nm to 10 #mu#m. Performance will be enhanced by the high brightness, low energy spread, and continuous pulse nature of the RTM electron beam. The authors are designing a new injector to increase the peak current of the RTM. A 3.6-m undulator is under construction, and the 9-m optical cavity is under design. The FEL will emit a continuous train of 3-ps pulses at 66 MHz with an average power of 10--200 W, depending on the wavelength, and a peak power of up to several hundred kW. An experimental area is being prepared with up to five stations for ...
The construction and the development of a UV free electron laser have been started under the cooperation of Nihon U, KEK, PNC, ETL and Tohaku U. The project requires a 100MeV S-band electron linear accelerator to expand the oscillation of FEL using fundamental mode to the UV region. The injection system consists of a thermionic RF-gun with a LaB cathode and an {alpha} magnet for magnetic bunching. We are studying to reduce the back-bombardment electrons to realize the macropulse length of 20{mu}sec. Electron beams, up to the energy of 100MeV, are injected into the optical oscillators. Changing the accelerating energy and/or undulator parameters, this system will cover the range from infrared to ultraviolet for the applications in various fields.
A technique capable of measuring the electron energy fluence spectra in a scattering medium was designed. These measurements were performed by setting a bremsstrahlung conversion target on the surface of a phantom, at an intermediate depth, and at a depth equal to electron mean range. The bremsstrahlung produced by the deceleration of electrons in the target was passed through an air channel in the phantom and passed forward by a pinhole collimator into a Na(Tl) detector. The measured pulse height data were unfolded to correct for the distortion of the spectrometer system by using the FORIST unfolding code. The unfolded bremsstrahlung spectra represent the electron energy fluence spectra convolution with the bremsstrahlung produced in the target. To generate the electron energy fluence spectra, the unfolded bremsstrahlung spectra were deconvoluted by using the MAZE2 unfolding code. ...
A 10.6-micron wavelength free-electron laser (FEL) amplifier has been operated using a 45-MeV, 600-A electron beam from the Advanced Test Accelerator (ATA) and a 15.36-meter long electromagnetic wiggler. The peak small signal power gain was 27 dB(500). Gain guiding was observed to confine the amplified laser beam.
Characterization of the electron beam's properties will be a major task after the upgrade of the Los Alamos Free-Electron Laser (FEL) Facility with a photoelectric injector (PEI) and increased acceleration capability to 40 MeV. Adjustments to the previous diagnostics package that address the lower beam emittance, higher energy, and wakefield source reduction issues will be discussed. 6 refs., 8 figs., 1 tab.
A description of the FEL experiment underway at the 10 kA, 5 MeV Experimental Test Accelerator (ETA) is described. The facility has been designed to investigate the high-gain operation of an FEL.
The description and results of the study on the free-electron laser (FEL) on 100 #mu#m, representing the first line of the FIAN multipurpose radiation complex, are presented. The electron beam with the energy of 6-8 MeV, once accelerated in a racetrack microtron and extracted into the FEL injection tract, is used for exciting this FEL. The system of the electron beam transport, injection and diagnostics are described. Additional works on increasing the beam emittance up to 0.4 A for one energy spread percent are carried out. The obtained electron beam parameters assure generation of the far infrared radiation in the FEL
A study was made on the effect of 3.5 MeVelectron irradiation on the properties of light-emissive structure based on GaAlAs. It is shown that a considerable decrease in the emitted light intensity as a result of electron irradiation not accompanied by changes in recombination- and electric properties of the mentioned structures. It is established by the electron-microscopy and Auger-spectroscopy meazurements that electron irradiation causes the occurrence of regions of free aluminium clusters on the external surface of the structure n-layer. The number and the sizes of the regions depend on the electron doze. It was assumed that the mentioned regions can play a role of attenuation filter for the light emitted by the structure.
A high-power microwave Free Electron Laser (FEL) experiment has been performed to study the inherent electron beam bunching that occurs in the FEL interaction. An induction linac delivered a 1 kA, 2.2 MeVelectron beam to a FEL amplifier. In the process of amplifying the input signal of frequency 35 GHz to power levels of the order of 10 MW, the electron beam was bunched by the ponderomotive force. In this paper we describe the FEL experiment and the optical technique that was used to observe the bunches. Their properties as functions of the basic FEL parameters are discussed. copyright 1996 American Institute of Physics.
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antinuclei with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, $15^{th}$ 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. In this work we describe the scientific objectives and the performance of PAMELA in its first two years of operation. Data on protons of trapped, secondary and galactic nature - as well as measurements of the December $13^{th}$ 2006 Solar Particle Event - are also provided.
In electron beam therapy, tissue overdose due to electrons backscattered from lead has been profusely studied. To quantify this dose enhancement effect, an electron backscatter factor (EBF) wasdefined as the ratio of dose at the tissue-inhomogeneity interface with and without the scatterer present. The dependence of the EBF on energy at the scatterer surface is not well known for energies lower than 3 MeV which is the most frequent clinical situation. In this work, we have done Monte Carlo calculations with the GEANT code to study EBF in lead at this energy range. The applicability of this code and the developed procedure for dose estimation has been experimentally verified. The dependence of the EBF on the beam energy incident on the scatterer has been studied for different nominal beam energies incident at the phantom's surface. The results show a trend of increase of EBF with the beam energy ...
The form factor for excitation of the 1/sup +/ state at 3.48 MeV in /sup 88/Sr by inelastic electron scattering has been measured for momentum transfers q = 0.24-0.62 fm/sup -1/. Neither its magnitude nor shape can be described employing the best available nuclear wave functions. We demonstrate with a schematic model that the observed reduction of the form factor may be understood by taking into account a renormalization of the M1-operator due to virtual ..delta..-hole excitations.
The form factor for excitation of the 1"+ state at 3.48 MeV in "8"8Sr by inelastic electron scattering has been measured for momentum transfers q = 0.24-0.62 fm"-"1. Neither its magnitude nor shape can be described employing the best available nuclear wave functions. We demonstrate with a schematic model that the observed reduction of the form factor may be understood by taking into account a renormalization of the M1-operator due to virtual #DELTA#-hole excitations. (orig.).
Initial design parameters and early operational results of a 50 MeV high brightness electron linear accelerator are described. The system utilizes a radio frequency electron gun operating at a frequency of 2.856 GHz and a nominal output energy of 4.5 MeV followed by two, 2#pi#/3 mode, disc loaded, traveling wave accelerating sections. The gun cathode is photo excited with short (6 psec) laser pulses giving design peak currents of a few hundred amperes. The system will be utilized to carry out infra-red FEL studies and investigation of new high gradient accelerating structures.
The lifetime of the circulating electron beam in the Naval Research Laboratory modified betatron has been increased by more than 2 orders of magnitude with the addition of strong focusing windings to the device. The injected beam consistently spirals from the injector to the minor axis and is trapped. The #approx#0.5-kA trapped electron ring has been accelerated above 10 MeV from the injection energy of 0.5 to 0.6 MeV. The beam acceleration has been confirmed not only by the x-ray attenuation technique but also with the detection of photoneutrons.
Paper presents conceptual design of free electron laser (FEL) complex for industrial applications. The FEL complex consists of three. FEL oscillators with the optical output spanning the infrared (IR) and ultraviolet (UV) wave-lengths (#lambda# = 0.3...20 #mu#m) and with the average output power 10 - 20 kW. The driving beam for the FELs is produced by a superconducting accelerator. The electron beam is transported to the FELs via three beam lines (125 MeV and 2 x 250 MeV). Peculiar feature of the proposed complex is a high efficiency of the. FEL oscillators, up to 20 %. This becomes possible due to the use of quasi-continuous electron beam and the use of the time-dependent undulator tapering.
Excessive irradiation due to unexpected leakage was found on a patient receiving electron beam therapy. The cause of this leakage was analyzed and the amount of leakage was measured for different electron beam energies. The highest leakage occurred with a 6 x 6 cm cone using a 12 MeVelectron beam. The leakage dose measured along the side of the cone could be as great as 40%. Until the cones are modified or redesigned, it is advised that all patient setups be carefully reviewed to assure that no significant patient areas are in the side scatter region.
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal {alpha}-Al{sub 2}O{sub 3} samples irradiated with triple ion beams (0.25 MeV H{sup +}, 0.6 MeV He{sup +} and 2.4 MeV O{sup 2+}; `Triple (A)`), (0.33 MeV H{sup +}, 0.45 MeV He{sup +} and 1.3 MeV O{sup +}; `Triple (B)`) and three consecutive single ion beams (0.3 MeV H{sup +} ion followed by 0.6 MeV He{sup +} and then 0.8 MeV O{sup +} ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 {mu}m in depth causing a swelling of 0.1% at the peak, ...
The radiation-induced microstructural changes have been studied by cross-sectional transmission electron microscopy for single-crystal #alpha#-Al_2O_3 samples irradiated with triple ion beams (0.25 MeV H"+, 0.6 MeV He"+ and 2.4 MeV O"2"+; 'Triple (A)'), (0.33 MeV H"+, 0.45 MeV He"+ and 1.3 MeV O"+; 'Triple (B)') and three consecutive single ion beams (0.3 MeV H"+ ion followed by 0.6 MeV He"+ and then 0.8 MeV O"+ ions) at 650 C to doses in the range 0.1-8.4 dpa at the damage peak. In the specimen irradiated with Triple (A), having the same average projected range to a total peak dose of 3.7 dpa, cavities with an average diameter of 13 nm were formed between 1.2 and 1.75 #mu#m in depth causing a swelling of 0.1% at the peak, which is larger than those of the specimens irradiated ...
Radiotherapy can be very significant as the treatment for ocular lesions, eyes need to be preserved as properly as possible on their functions and cosmetics. The application of conventional X ray therapy has been gradually abandoned as conventional X ray therapy ceased to be accepted as the general treatment for malignant tumors. Consequently the necessity of electron beam therapy has been rising even as the substituted method for conventional X ray therapy. The department of radiology of Gunma University was obliged to establish a new therapy for ocular lesions, and has been trying electron beam therapy since 1973. It is concluded that electron beam therapy is not at all inferior to conventional X ray therapy as reported above. Basic therapeutic methods for ocular lesions are the following: 1) For epidermoid carcinoma, 600 rads at a time, 3600 - 4200 rads in total is applied by 8 MeV ...
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
The inverse Compton scattering between positron bunches and the Free Electron Laser (FEL) of the SuperAco storage ring generates a collimated and tunable gamma-ray beam. The use of the FEL instead of a conventional laser, automatically provides the transverse alignment and synchronisation of the electron and optical beams. The Super-ACO FEL is operated in the 300-430 nm range at 800 MeV with a high repetition rate (8 MHz) and an average transmitted power of 300 mW at 350 nm. High energy gamma rays of 35 MeV are produced with a rate of 1.5 10 7 photons/second and good monocromaticity (about 10%). Applications of the SuperAco FEL installation for diamond irradiation and biological studies are envisaged. (author)
Coherent Smith-Purcell radiation, emitted from short-bunched electrons passing by a lamellar-type grating of aluminum, has been observed in the millimeter wave region. The energy of the electrons is either 42 MeV when they are accelerated by an L-band linear accelerator or 150 MeV accelerated by an S-band one. The intensity of the radiation is proportional to the square of the beam current. The radiation is linearly polarized, and the electric vector of the radiation is in the plane defined by the observing point and the beam trajectory. The intensity decreases with the beam height, i.e. the distance of the beam from the surface of the grating, in accordance with the modified Bessel function of zeroth order. copyright 1996 American Institute of Physics.
Studies of Rydberg-atom destruction in collisions with the polar targets CH_3I and CH_2Br_2 for values of principal quantum number n in the range 100--400 are reported. Analysis of the data using the essentially-free-electron model suggests that, for ultralow electron energies (#approx#80 #mu#eV to 1 meV), the cross section #sigma#(var-epsilon) for rotationally inelastic scattering of electrons by a polar target varies approximately as 1/var-epsilon, where var-epsilon is the electron energy. The Born approximation does not predict such behavior at very low collision energies, and possible reasons for this discrepancy are discussed.
Free electron laser (FEL) facilities as the FELI FEL Facility are proposed, for which a 150-MeV linac type injector for a Saga synchrotron light source (SLS) is employed in FEL mode. The linac has two operating modes; short macropulse mode a 1 #mu#s at 150 MeV for injection to a 1 - 1.3-GeV third generation type storage ring and long macropulse mode of 12 #mu#s at 100 MeV for four FEL Facilities. The macropulse beam consists of a train of several ps, 0.6 nC microbunches (peak current 100 A) repeating at 89.25 MHz. We are aiming to supply high power level photon beams covering an attractive wavelength range from 0.05 nm (25 keV) to 200 #mu#m (0.006 eV) for scientific researches, bio-medical and industrial applications, using the Saga third generation type SLS with a superconducting wiggler and the proposed four FEL Facilities. (author)
We have measured the K-shell ionization probability across the 6.06-MeV resonance in /sup 88/Sr(p,p/sub 0/) where the resonance width is large compared to the energy transferred to the electron. The results are found to agree quantitatively with the theory developed by Blair and Anholt. The effect of the time delay on the ionization probability, introduced by the nuclear scattering at the resonance energy, is discussed.
The differential cross section for excitation of the 1/sup +/ state at Esub(x)=3.486 MeV in /sup 88/Sr by inealstic electron scattering has been measured for values of the momentum transfer q between 0.22 and 2.57 fm/sup -1/. Both nuclear core polarization and ..delta..-hole polarization seem to be necessary to describe the observed reduction of the B(M1) value and data at low q and the behaviour of the cross section at intermediate values of q. 42 references.
The form factor for excitation of 1/sup +/ state at 3.846 MeV in /sup 88/Sr by inelastic electron scattering has been measured for q=0.22-2.57 fm/sup -1/. Both nuclear core polarization and ..delta..-hole polarization seem to be necessary to describe the observed reduction of the B(M1)-value and data at low q and the peculiar shape of the form factor at intermediate values of q.
The differential cross section for excitation of the 1"+ state at Esub(x)=3.486 MeV in "8"8Sr by inealstic electron scattering has been measured for values of the momentum transfer q between 0.22 and 2.57 fm"-"1. Both nuclear core polarization and #DELTA#-hole polarization seem to be necessary to describe the observed reduction of the B(M1) value and data at low q and the behaviour of the cross section at intermediate values of q. (orig.).
The neutron transition multipole moment, M/sub n/, for (0/sup +/..-->..2/sup +/, 1.84 MeV) transition is inferred by measuring the (..cap alpha..,..cap alpha..') angular distribution at E/sub ..cap alpha../ = 50 MeV and comparing it with a microscopic distorted-wave Born approximation calculation. Proton transition densities are taken from electron scattering data. M/sub n//M/sub p/ is found to be substantially less than N/Z in agreement with the (p,p') result.
We have mapped and studied the effects of MeV alpha-particle bombardment in polyvinylidene chloride (PVDC) and polyethylene (PE). We used 3.5 and 5.0 MeV alpha-particle incident beams and stacked polymer films to separate the contributing effects of the electronic ({var_epsilon}{sub e}) and nuclear ({var_epsilon}{sub n}) stopping powers. The electrical conductance and change in the chemical structures were measured by direct resistivity measurement, Raman microprobe, RBS and FTIR. The results indicate significant differences in the ({var_epsilon}{sub e}) and ({var_epsilon}{sub n}) effects at higher alpha-particle bombardment fluences. {copyright} {ital 1997 American Institute of Physics.}
A prototype electron applicator system providing circular and rectangular fields for use in intraoperative electron beam therapy with a Varian Clinac 18 linear accelerator has been fabricated. The dosimetric properties of this system for a variety of electron-beam energies, applicator sizes, and x-ray collimator settings was documented. Significant findings include: (a) surface dose values are in excess of 90% for electron energies of 12 MeV and above; (b) for the 18-MeV beam, the deepest depth where the central axis dose is 90% of its maximum value is in excess of 50 mm for circular applicators whose diameters are in excess of 5 cm; and (c) the treatment time to deliver 1000 rads ''given dose'' (at a given dose rate of 300 MU/min) is on the order of 3--4 min. Cross-field behavior is acceptable for the intended application and x-ray contamination is less than 4% ...
The paper discusses some of the assumptions and methods employed for the control of ionizing radiation in the specifications for the civil construction of a planned free electron laser facility based on a 200 MeV, 5 mA superconducting recirculation electron accelerator. Consideration is given firstly to the way in which the underlying building configuration and siting aspects were optimized on the basis of the early assumptions of beam loss and radiation goals. The various design requirements for radiation protection are then considered, and how they were folded into an aesthetically pleasing and functional building. copyright 1997 American Institute of Physics.
Forty-three patients with basal and squamous cell carcinomata arising on the pinna were treated radically using a 10 MeVelectron beam. The technique and dosage are described and discussed. Primary cancer control with retention of the pinna was achieved in 34 patients. Salvage pinnectomy was performed in four patients for recurrence and one patient for radiation necrosis. Two patients with large primary tumours failed to resolve and died of their disease. The advantages for the patient of the policy of primary radical electron beam therapy are discussed.
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus minus} 0.2%), and drive laser phase stability (< 2 ps (rms)). 10 refs.
The ongoing upgrade of the Los Alamos Free-Electron Laser (FEL) Facility involves the addition of a photoelectric injector (PEI) and acceleration capability to about 40 MeV. The electron-beam and high-speed diagnostics provide key measurements of charge, beam position and profile, divergence emittance, energy (centroid, spread, slew, and extraction efficiency), micropulse duration, and phase stability. Preliminary results on the facility include optical transition radiation interferometer measurements of divergence (1 to 2 mrad), FEL extraction efficiency (0.6 {plus_minus} 0.2%), and drive laser phase stability (< 2 ps [rms]). 10 refs.
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO{sub 2} layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide ...
The influence of high energy electron (23 MeV) irradiation on the electrical characteristics of p-channel polysilicon thin film transistors (PSTFTs) was studied. The channel 220 nm thick LPCVD (low pressure chemical vapor deposition) deposited polysilicon layer was phosphorus doped by ion implantation. A 45 nm thick, thermally grown, SiO_2 layer served as gate dielectric. A self-alignment technology for boron doping of the source and drain regions was used. 200 nm thick polysilicon film was deposited as a gate electrode. The obtained p-channel PSTFTs were irradiated with different high energy electron doses. Leakage currents through the gate oxide and transfer characteristics of the transistors were measured. A software model describing the field enhancement and the non-uniform current distribution at textured polysilicon/oxide interface was developed. In order to assess the irradiation-stimulated changes of gate oxide ...
The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeVelectron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well.
Portal localization images for high-energy electron beam therapy are necessary to confirm the treatment field by comparing them with a simulation image obtained before treatment or portal verification images after treatment. In this study, portal localization images were acquired using the computed radiography (CR) system and bremsstrahlung X-rays generated in the electron beam irradiations. All images obtained with phantom and the irradiations of in the electron energy of 8, 10, 12 and 15 MeV were feasible for clinical use. The CR system used in this study included general diagnostic imaging cassette and storage phosphor plate, but none of other special devices. The system can usually supply portal localization images, which maintains the quality assurance of high-energy electron beam therapy. (author)
We present the design, analysis, and results of the high brightness electron beam experiments currently under investigation at Sandia National Laboratories. The anticipated beam parameters are the following: energy 12 MeV, current 35 endash 40 kA, rms radius 0.5 mm, and pulse duration 40 ns full width at half-maximum. The accelerator is SABRE, a pulsed linear inductive voltage adder modified to higher impedance, and the electron source is a magnetically immersed foilless electron diode. 20 endash 30 T solenoidal magnets are required to insulate the diode and contain the beam to its extremely small-sized (1 mm) envelope. These experiments are designed to push the technology to produce the highest possible electron current in a submillimeter radius beam. Design, numerical simulations, and experimental results are presented. copyright 1997 American Institute of Physics.
The galvanomagnetic properties of single-crystal samples of the Bi{sub 0.93}Sb{sub 0.07} semiconductor alloy with the electron density n = 1.6 x 10{sup 17} cm{sup -3} in magnetic fields up to 14 T at T = 1.6 K have been investigated. The resistivity {rho} and Hall coefficient R have been measured as functions of the magnetic field directed along the binary axis of a crystal for a current flowing through a sample along the bisector axis; i.e., the components {rho}{sub 22} and R{sub 32,1} have been measured. The strong anisotropy of the electron spectrum of the samples makes it possible to separately observe quantum oscillations of the magnetoresistance {rho}{sub 22}(H) for H -parallel C{sub 2} in low magnetic fields for two equivalent ellipsoids with small extremal cross sections (secondary ellipsoids) and in high magnetic fields for electrons of the ellipsoid with a large extremal cross section (main ellipsoid). An increase ...
Modifications of the structure and mechanical properties in LiF crystals irradiated with MeV-energy Au ions have been studied using nanoindentation, atomic force microscopy and optical spectroscopy. The nanostructuring of crystals under a high-fluence irradiation (above 1013 ions/cm2)?was?observed. Nanoindentation tests show a strong ion-induced increase of hardness (up?to 150?200%), which is related to the high volume concentration of complex color centers, defect aggregates, dislocation loops and grain boundaries acting as strong barriers for dislocations. From the?depth profiling of the hardness and energy loss it follows that both nuclear and electronic stopping mechanisms of MeV Au ions contribute to the creation of damage and hardening. Whereas the electronic stopping is dominating i...
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological characterization then used at another site.
Since 1979, scientists and engineers at the Los Alamos National Laboratory have designed, constructed, and operated a radio-frequency (RF) linac free-electron laser (FEL) at wavelengths from 9 to 45 /mu/m. Coupled with success of other research centers investigating wavelengths from the visible to far-infrared, Los Alamos is now proposing a vacuum-ultraviolet and soft x-ray (referred to henceforth as extreme ultraviolet, (XUV)) FEL oscillator/Self-Amplified Spontaneous Emission amplifier with beam energies ranging from 100 MeV to 1 GeV. This paper will focus on the first milestone of the proposed Los Alamos XUV project, i.e., a 250-MeV linac with approximately 50 mA of average current, producing photons with wavelengths below 1000 /angstrom/. 3 refs., 3 figs.
In the case of total skin electron therapy without the beam guide, the electron beam is scattered just outside the gantry exit, dose uniformity in the field is broken, and dose is spread outside the light field. The aims of this study were to measure the mean energy of the off-axis incident electron beam without the beam guide and to establish a reference for the clinical situation. For the measurement, a 4 MeVelectron beam was selected among several energies from the linear accelerator. A scintillating fiber beam energy monitor measured the mean energy of the incident electron beam. This energy monitor is a small, light-weight piece of equipment composed of a wedge absorber, scintillation fiber, and photodiode. We found the relationship between electron energy and the indicated value of the energy monitor by means of the estimation of ...
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range (protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of $10^{-8}$). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15 2006 in a $350\\times 600 km$ orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is ...
PAMELA is a satellite borne experiment designed to study with great accuracy cosmic rays of galactic, solar, and trapped nature in a wide energy range protons: 80 MeV-700 GeV, electrons 50 MeV-400 GeV). Main objective is the study of the antimatter component: antiprotons (80 MeV-190 GeV), positrons (50 MeV-270 GeV) and search for antimatter with a precision of the order of 10^-8). The experiment, housed on board the Russian Resurs-DK1 satellite, was launched on June, 15, 2006 in a 350*600 km orbit with an inclination of 70 degrees. The detector is composed of a series of scintillator counters arranged at the extremities of a permanent magnet spectrometer to provide charge, Time-of-Flight and rigidity information. Lepton/hadron identification is performed by a Silicon-Tungsten calorimeter and a Neutron detector placed at the bottom of the device. An Anticounter system is used offline ...
Simulations and experiments have been carried out to explore using a plastic scintillator as a dosimetry probe in the vicinity of a pulsed bremsstrahlung source in the range 4 to 20 MeV. Taking advantage of the tissue-equivalent properties of this detector in conjunction with the use of a fast digital signal processor near real-time dosimetry was shown to be possible. The importance of accounting for a broad energy electron beam in bremsstrahlung production, and photon scattering and build-up, in correctly interpreting dosimetry results at long stand-off distances is highlighted by comparing real world experiments with ideal geometry simulations. Close agreement was found between absorbed energy calculations based upon spectroscopic techniques and calculations based upon signal integration, showing a ratio between 10 MeV absorbed dose to 12 MeV absorbed dose of 0.66 at a distance of 91.4 m from the ...
Dipole and quadrupole excitations in the semimagic N{sup .} = 50 nucleus {sup 88}Sr were investigated at the superconducting electron linear accelerator ELBE with bremsstrahlung produced at electron energies of 9.0, 13.2, and 16.0 MeV. About 160 {gamma} transitions were identified up to 12 MeV. By using polarized photons linear polarizations of about 50 {gamma} transitions were measured. In the energy range of 6 - 12 MeV there is only one M1 transition while all other transitions have E1 character. Statistical methods were applied in order to filter out inelastic transitions and to correct the intensities of the ground-state transitions for their branching ratios. The photoabsorption cross section obtained in this way provides information about the extension of the Giant Dipole Resonance towards energies below the neutron-separation energy. The experimental results are compared with ...
The studies using phantoms confirmed that the reduction of electron beam energy and minimization of X-ray contamination could be achieved when electron beam was interposed by an acrylic plate placed 20 cm anterior to a patient. Four patients of mycosis fungoides were treated with 8 MeVelectron beam of a linear accelerator at UOEH Hospital from October 1981 to December 1986. Two of them were treated with this technique by placing 2 cm thick acrylic plate anterior to the patients and satisfactory results were obtained. Cutaneous lesions subsided remarkably with the dosage of 2000 cGy given in 2 months. Leucopenia due to bone marrow suppression was mild and the patients tolerated the treatment well. (author).
At Los Alamos, we are building a free-electron laser (FEL) for industrial, medical, and research applications. This FEL, which will incorporate many of the new technologies developed over the last decade, will be compact in size, robust, and user-friendly. Electrons produced by a photocathode will be accelerated to 20 MeV by a high-brightness accelerator and transported using permanent-magnet quadrupoles and dipoles. They will form an electron beam with an excellent instantaneous beam quality of 10 {pi} mm mrad in transverse emittance and 0.3% in energy spread at a peak current up to 300 A. Including operation at higher harmonics, the laser wavelength extends form 3.7 {mu}m to 0.4 {mu}m. In this paper, we will describe the project and the programs to date. 10 refs., 10 figs., 1 tab.
Dislocation priming measurements were performed in the kHz range in ASARCO copper. The samples and irradiation facilities are constructed so as to allow successive irradiation of samples both with electrons and gamma rays. The gamma rays were produced by stopping 2.8-MeVelectrons in a gold target. The change of the type of irradiation could be achieved without any handling of the sample. Thus it is possible to detect rather small differences between the two types of irradiation. Recovery experiments at 400 deg K after 75 deg K irradiation and pinning rates during irradiation at 400 deg K and 75 deg K were made. (GE)
The exafs method is proposed as a more informative, universal one to investigate the radiation defects in solids. The successful results as obtained by the author using the synchrotron radiation source are reported for the first time. The measurements were carried out in GaAsP crystals irradiated with 50 MeVelectrons.
Chemical effects on the intensity ratio of LX-ray of molybdenum compounds irradiated by 11-keV electrons and by 3-MeV protons were studied using an x-ray crystal spectrometer. It was found that the intensity ratios of L_#gamma#_1/L_#beta#_1 markedly decrease with the increase of ionicity of molybdenum compounds, except for the case of metallic molybdenum. (author).
The MiniBooNE Collaboration reports first results of a search for {upsilon}{sub e} appearance in a {upsilon}{sub {mu}} beam. With two largely independent analyses, we observe no significant excess of events above background for reconstructed neutrino energies above 475 MeV. The data are consistent with no oscillations within a two neutrino appearance-only oscillation model.
Cross sections for some electro- and photoinduced spallation reactions on {sup 27}Al and {sup 51}V are measured in the energy region 130 MeV to 580 MeV with the activation method. Comparisons are made with calculations based on the Dalitz formalism for virtual photon spectra, and Monte Carlo calculations based on a cascade evaporation model, respectively. By use of Bremsstrahlung with end-point energies from threshold to 750 MeV, the yields for photo- production of{pi}{sup -}leading to ground and isomeric states in {sup 197}Hg are measured with the activation method. The activity from the Hg-isotopes were measured after a chemical separation of Hg from the target material. The yields and isomeric ratios are compared with impulse approximation calculations. For the photoproduction of {sup 195m}Hg and {sup 192}Hg from {sup 197}Au, the yields were measured. The experimental mean cross sections are compared with data from other ...
We have studied L x-rays from 64 MeV iodine projectile in collision with various gas targets, Z_2 #18, do not arise from selective M subshell vacancy population, has been conclusively established by the observations by Datz et al (1971) and by Saha et al (1996) that the measured intensity ratio of the Ll and L#alpha# lines, which arise because of transitions from different M subshells into the same L, subshell, does not show any periodic behaviour with Z, but stays rather constant. Differences in the measured L#beta#_1/L#alpha# intensity ratio of iodine with 7"+ and 24"+ charge states impinging on Kr target established the minor role of the electrons in the N shell of the projectile in the x-ray production mechanism. (author)
Photoluminescence spectroscopy measurements were carried out for silicon 50{mu}m BSFR space solar cells irradiated with 1MeVelectrons with a fluence exceeding 1 x 10{sup 16} e/cm{sup 2} and 10MeV protons with a fluence exceeding 1 x 10{sup 13} p/cm{sup 2}. The results were compared with the previous result performed in a relative low fluence region, and the radiation-induced defects which cause anomalous degradation of the cell performance in such large fluence regions were discussed. As far as we know, this is the first report which presents the PL measurement results at 4.2K of the large fluence radiation irradiated silicon solar cells. (author)
By method of transmission electron microscopy and measuring of microhardness the peculiarities of influence of radiation defect clusters on molybdenum radiation hardening along range path of protons with 30 MeV initial energy are studied. Decrease effect of hardening growth value and even its absence depending on irradiation dose in the range of 10-20 MeV proton energies in presence of high density of radiation defect dispersed clusters is revealed. It is shown experimentally that this effect is connected with accumulation of hydrogen up to not very high concentrations (not more than 5x10"-"4 at.%) at the expense of elastic and inelastic proton scattering. 5 refs.; 5 figs.
Increasing frequency of skin cancer, mycosis fungoides, Kaposi sarcoma etc, it need to treatment dose planning for total skin electron beam (TSEB) therapy. Appropriate treatment planning for TSEB therapy is needed to give homogeneous dose distribution throughout the entire skin surface. The energy of 6 MeVelectron from the 18 MeV medical linear accelerator was adapted for superficial total skin electron beam therapy. The energy of the electron beam was reduced to 4.2 MeV by a 0.5cmx90cmx180cm acryl screen placed in a feet front of the patient. Six dual field beam was adapted for total skin irradiation to encompass the entire body surface from head to toe simultaneously. The patients were treated behind the acryl screen plate acted as a beam scatterer and contained a parallel-plate shallow ion chamber for dosimetry and beam monitoring. ...
We have observed a threshold in the electron photodetachment cross section of {sup 88}Sr{sup {minus}} ions at a photon energy {ital h}{nu}=1.820 eV and assign it to a {ital p}-wave transition from the 5{ital s}{sup 2}5{ital p}{sup 2}{ital P} ground state in Sr{sup {minus}} to the 5{ital s}5{ital p}{sup 3}{ital P} state in neutral Sr. The measurement was made with a new technique combining the tunable laser photodetachment threshold method with accelerator mass spectrometry. We determine for the first time the electron affinity of Sr to be 48{plus_minus}6 meV, much smaller than predicted in recent calculations. The {sup 2}{ital P}{sub 1/2}-{sup 2}{ital P}{sub 3/2} fine splitting of the Sr{sup {minus}} ground state is estimated to be 26{plus_minus}8 meV.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatial position and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kicks are reported as a function of charge.
A model for the simulation of the time dependent behavior and the analysis of the equilibrium of the coupled system of storage ring and Free Electron Laser (FEL) is presented. The analysis comprises both amplifier and oscillator FEL. Bunch lengthening and energy widening due to wake forces are taken into account in a self-consistent way. The method is based on a mapping algorithm for means and correlations of the electron distribution function, pioneered by K. Hirata. The evolution of the laser field in the oscillator FEL is described by K. Hirata. The evolution of the laser field in the oscillator FEL is described by supermodes. The model is used to simulate an FEL in a small 500 MeV storage ring with 100 m circumference. Typical values for the output power, spatial, and spectral characteristics of the emitted radiation are presented.
The advance in laser-plasma acceleration techniques pushes the regime of the resulting accelerated particles to higher energies and intensities. In particular the upcoming experiments with the FLAME laser at LNF will enter the GeV regime with almost 1nC of electrons. From the current status of understanding of the acceleration mechanism, relatively large angular and energy spreads are expected. There is therefore the need to develop a device capable to measure the energy of electrons over three orders of magnitude (few MeV to few GeV) under still unknown angular divergences. Within the PlasmonX experiment at LNF a spectrometer is being constructed to perform these measurements. It is made of an electro-magnet and a screen made of scintillating fibers for the measurement of the trajectories of the particles. The large range of operation, the huge number of particles and the need to focus the divergence present unprecedented ...
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 [mu]s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
Time-resolved characterizations of electron beams using optical transition radiation (OTR) as a prompt conversion mechanism have recently been extended on the Los Alamos Free-electron Laser (FEL) facility 40-MeV linac. Two key timescales for rf-linac driven FELs are the micropulse (10 ps) and the macropulse (5 {mu}s to 1 ms). In the past we have used gated, intensified cameras to select a single or few micropulses (25 to 400 ns gate width) out of the pulse train to evaluate submacropulse effects. Recently, we have obtained some of the first measurements of micropulse bunch length (7 to 10 ps) and submacropulse spatialposition and profile using OTR and a Hamamatsu streak camera. Additionally, micropulse elongation effects and head-to-tail transverse kick effects are reported as a function of charge.
A beam of 3.6 MeVelectrons has been used to study the generation of radiation in far infra-red (FIR) by the Smith-Purcell mechanism. The dependence of wavelength on angle of emission, over angles from 56 deg to 150 deg and wavelengths from 350 #mu#m to 1860 #mu#m, is in excellent agreement with the Smith-Purcell dispersion relation. Comparison of the yield with that from a 5000 K source suggests that the spontaneous Smith-Purcell effect offers an easily tunable alternative to the synchrotron as a coherent FIR source, and could form the basis of a cheap, compact Free Electron Laser (FEL). (author) 6 refs.; 5 figs.
The Fermilab Linac Upgrade is planned to increase the energy of the H- linac from 200 to 400 MeV. This is intended to reduce the incoherent space-charge tuneshift at injection into the 8 GeV Booster which can limit either the brightness or the total intensity of the beam. The Linac Upgrade will be achieved by replacing the last four 201.25 MHz drift-tube tanks which accelerate the beam from 116 to 200 MeV, with seven 805 MHz side-coupled cavity modules operating at an average axial field of abut 7.5 MV/m. This will allow acceleration to 400 MeV in the existing Linac enclosure. Each accelerator module will be driven with a klystron-based rf power supply. A prototype rf modulator has been built and tested at Fermilab, and a prototype 12 MW klystron is being fabricated by Litton Electron Devices. Fabrication of production accelerator modules is in progress. 8 figs., 4 tabs.
Technique, allowing to investigate straggling zone (full braking) from high-energy charged particles in detail, is described. Experimental results on investigation of efective structure, created in polycrystalline molybdenum (99.97%) within 29 MeV alpha-particles straggling zone for fluences from 3.8x10"1"9 up to 3.7x10"2"1 #alpha#/m"2 by methods of microhardness (H_#mu#, X-ray structural analysis (#DELTA#a/a) and transparent electron microscopy (TEM), are presented. It is determined, that for doses from 3.8x10"2"0 #alpha#/m"2 and higher, at #approx#6 MeV energy, molybdenum ''softening'' is observed, H_#mu# curve within straggling zone is well described by alloyage calculated profile. #DELTA#a/a measurements within straggling zone are well described by damage profile. TEM-investigations have shown the developed defective structure even within molybdenum ''softening'' range.
The results of investigation into a new series of Z-even nuclei - precursors of delayed protons (PDP) -"6"5Ge, "8"9Se, "9"3Kr, "8"1Zr, and "8"5Mo are presented. PDP were obtained by irradiation of targets in the following reactions: Zn(He, 2n) "6"5Ge, 22 MeV; "4"0Ca("3"2S, 2 pn) "1"9Se, 100 MeV; "6"0Ni ("1"60, 3 n), "7"3Kr, 75 MeV; "5"2Cr ("3"2S, 3n)"8"1Zr, 110 MeV; "5"6Fe("3"2S, 3n)"8"5Mo, 120 MeV. The targets (self-sustaining foils of thickness approximately 1.2 mg/cm"2) were placed at an angle of 15 deg to the direction of the ion beam. Upon irradiation targets were moved downwards into a measuring position. The spectra of protons, X and gamma-rays, and also the spectra of p - x, p-#gamma#, x - #gamma# coincidences accompanying the decay of "6"5Ge, "6"9Se,"7"3Kr and "8"1Zr, and "8"5Mo were measured. The measured half-lives are equal, to 31.5+-1.9, 27.3+-0.5, 28.5+-1.1, 6.3+-0.5, ...
Potassium atoms in selected high-lying np Rydberg states (80 #<=# n #<=# 400) are being used as a tool to examine electron-polar molecule collisions at ultra-low energies (#approx#80 #mu#eV - 1 meV). This energy regime has not been investigated previously and is of interest because the corresponding electron de Broglie wavelength is large, #approx#1300 - 330 Angstrom, and because the collision time is comparable to the period of molecular rotation. A variety of target molecules has been studied, including simple rotors such as HF, and more complex species such as NH_3, CH_3I, CH_2Br_2 and C_6H_5NO_2. These targets encompass a range of dipole moments and rotational behavior, but analysis of the data shows that in each case the cross section #sigma#(#epsilon#) for rotationally-inelastic electron-polar molecule scattering varies approximately as 1/#epsilon# where #epsilon# is the ...
A high power Free-Electron Laser (FEL) has lased at a wavelength of 22 #mu#m at the Japan Atomic Energy Research Institute (JAERI). The maximum power on a macro-pulse average is 1.7 kW, and it corresponds to an FEL energy of 160 #mu#J/micro-pulse. Extraction efficiency from the electron beam to the FEL radiation was measured to be 5.3% by an energy analyzer, when the maximum FEL power was coupled out. The rms wavelength spread was measured to be 4.6% at the same time. The extraction efficiency, in general, has a maximum value near the zero detuning length of an optical cavity, where (in contrast) the single-pass gain becomes smallest. A high peak current and a long macro-pulse duration are therefore indispensable for realizing high efficiency. The electron beam energy is 16.5 MeV, and the average current is 5.3 mA at a micro-pulse repetition rate of 10.4 MHz. The macro-pulse duration is 500 #mu#s (5000 ...
The KAERI compact far-infrared (FIR) free-electron laser (FEL) has been operated successfully in the wavelength range of 97-150 #mu#m. It is the first demonstration of FEL lasing by using a magnetron-based classical microtron. We developed a high precision undulator consisting of 80 periods, with each period being 25 mm. The field strength of the undulator can be changed from 4.5 to 6.8 kG with an amplitude deviation of only 0.05% in r.m.s value. The kinetic energy of the electron beam is 6.5 MeV. The average current and pulse duration of the electron beam macropulses are 45 mA and 5.5 #mu#s, respectively. The measured power of the FEL with the electron beam parameters was more than 50 W for a FIR macropulse having a duration of 4 #mu#s. The spectral width of the FEL was measured to be 0.5% of the central wavelength. The FEL system, aside from the racks for the controlling units, is ...
The peak flux relationship between hard X-rays and microwaves from solar flares is studied using about 400 events simultaneously recorded with the hard X-ray burst spectrometer on the SMM satellite and the Nobeyama 17 GHz radiometer. The data indicate that the hard X-ray and microwave peak fluxes correlate best for X-ray energies of less than about 80 keV for impulsive flares and greater than about 360 keV for extended flares. By postulating that electrons responsible for microwave emission at 17 GHz are those emitting hard X-rays at these photon energies, it is concluded that: (1) in impulsive flares, microwaves at about 20 GHz are emitted mainly by electrons of less than about 200 keV from a layer through which the electrons stream down into the thick-target hard X-ray source; and (2) in extended flares, microwaves are emitted mainly by MeVelectrons trapped in a coronal loop or ...
International standards and guidelines for calibrating high-dose dosimetry systems to be used in industrial radiation processing recommend that dose-rate effects on dosimeters be evaluated under conditions of use. This is important when the irradiation relies on high-current electron accelerators, which usually provide very high dose-rates. However, most dosimeter calibration facilities use low-intensity gamma radiation or low-current electron accelerators, which deliver comparatively low dose-rates. Because of issues of thermal conductivity and response, portable calorimeters cannot be practically used with high-current accelerators, where product conveyor speeds under an electron beam can exceed several meters per second and the calorimeter is not suitable for use with product handling systems. As an alternative, Monte Carlo calculations can give theoretical estimates of the absorbed dose in materials with flat or complex ...
An optical klystron is built in the 800 MeVelectron storage ring at University of Science and Technology of China for harmonic super-radiation generation. In single bunch operation mode the repetition rate of the spontaneous radiation pulses is about 4.533 MHz, and the repetition rate of the seed laser pulses is about 3 Hz, while the radiation pulse duration is 300 ps. For measuring harmonic radiation a high on/off ratio ICCD is used as an optical switch to reject spontaneous radiation pulses of high repetition rate
Recent results of the experiments at GOL-3 facility are presented. Plasma with a density of 1014...1016 cm-3 is confined in a 12-meter-long solenoid, which comprises 55 corrugation cells with mirror ratio Bmax/B min=4.8/3.2 T. The plasma is heated up to 2...4 keV temperature by a high power relativistic electron beam (?1 MeV, ? 330 kA, ?8?s, ?120 kJ) injected through one of the ends. Mechanism of experimentally observed fast ion heating, issued of plasma stability and confinement are discussed.
In future experiments the readout electronics for pixel detectors is required to be resistant to a very high radiation level. In this paper we report on irradiation tests performed on several preFPIX2 prototype pixel readout chips for the BTeV experiment exposed to a 200 MeV proton beam. The prototype chips have been implemented in commercial 0.25 {micro}m CMOS processes following radiation tolerant design rules. The results show that this ASIC design tolerates a large total radiation dose, and that radiation induced Single Event Effects occur at a manageable level.
Compositions (oligomers with suitable properties and Al, Fe, Cu, Ta, W powders) were hardured by the flux of accelerated electrons at 10 mA beam current and 1.5 MeV energy. Dielectric and mechanical properties of metal-filled polymeric compositions as well as their radioply sicl properties in SHF-range are studied. It is shown that the produced compositions belong tot he absorbing protective materials in which the protection effect is mainly achieved through the absorption losses. 6 refs.; 3 tabs.
This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeVelectron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.
Ion-photon and ion-Auger-electron coincidence measurements have been performed to study the impact parameter dependence of Xe M-shell excitation in 1.05 MeV Xe/sup 3 +/-Xe collisions. The experimental results are found to be consistent with the prediction of the molecular orbital model of atomic collisions. The average fluorescence yield for the Xe M shell is found to be strongly dependent on the impact parameter. This is ascribed to the production of highly charged Xe ions in close collisions.
We have obtained optically clear samples of LuAP:Ce from the Institute of Physical Research, Ashtarak, Armenia, measuring up to 5x5x40 mm{sup 3}. The photo electron yield for a number of theses samples was measured with a Philips XP2020Q photomultiplier tube, and 556 photo electrons per MeV was obtained for the best samples. This is comparable to what is obtained from BGO crystals under the same condition, but a factor of 5 less than what is obtained with an LSO sample of similar dimensions. The light in LuAP:Ce increases with cerium concentration between 0.13 and 0.47%.
Measurements of {gamma}-ray, {gamma}{gamma}-coincidence and internal conversion electron spectra from the {sup 106}Cd({alpha},n{gamma}){sup 109}Sn reaction were carried out at 15-20 MeV {alpha}-particle bombarding energies with Ge(HP) {gamma}-ray and superconducting magnetic lens plus Si(Li) electron spectrometers. The energies, relative intensities, internal conversion coefficients and coincidence relations of the {sup 109}Sn transitions were determined, and a more complete, consistent level scheme has been deduced. Spin and parity values have been determined from the internal conversion coefficients, the bombarding-energy dependence of the side-feeding intensities of the states and the available {gamma}-ray angular distribution data. The level scheme was interpreted in the framework of the quasi-particle shell model.
In the rf-driven free-electron laser (FEL) at the Los Alamos National Laboratory, there are two pulsed-power rf modulators as sources for two tandem, side-coupled 20-MeV linear accelerators. The rf power used to control the cavity fields is supplied by two 5.5-MW modulating anode klystrons operating at a center frequency of 1300.2 MHz. The modulation of the 125 kV klystron is achieved by using a triode switch tube that provides a pulse width up to 300 ..mu..s and a pulse repetition rate up to 10 Hz. This paper describes the present configuration of these two duplicate systems and presents plans for meeting the requirements of future rf FEL experiments at Los Alamos. 12 refs., 5 figs.
An add-on multileaf collimator for electrons (eMLC) has been developed that provides computer-controlled beam collimation and isocentric dose delivery. The design parameters result from the design study by Gauer et al (2006 Phys. Med. Biol. 51 5987-6003) and were configured such that a compact and light-weight eMLC with motorized leaves can be industrially manufactured and stably mounted on a conventional linear accelerator. In the present study, the efficiency of an initial computer-controlled prototype was examined according to the design goals and the performance of energy- and intensity-modulated treatment techniques. This study concentrates on the attachment and gantry stability as well as the dosimetric characteristics of central-axis and off-axis dose, field size dependence, collimator scatter, field abutment, radiation leakage and the setting of the accelerator jaws. To provide isocentric irradiation, the eMLC can be placed either 16 or 28 cm above the ...
An electron moving over the surface of a diffraction grating will transfer a part of its kinetic energy to radiation via a velocity synchronous coupling with a slow space harmonic component of the field. Since the phase velocity of a slow space harmonic is less than the speed of light, the slow components decay exponentially, or evanesce, with distance above the grating and the evanescence scale is determined by the product of the relative velocity, #beta#, the relative energy, #gamma#, and the wavelength #lambda#. Thus, in the relativistic regime, good electron - grating coupling can be maintained at beam heights that are greater than the emitted wavelength. In order to explore this regime a series of experiments have been carried out with moderately energetic beams and an experiment with the 70-MeV beam at the Accelerator Test Facility is in the planning stage. The work has two basic goals: the first is to explore the ...
A prototype for a quasi-cw, and high-average power free electron laser (FEL) driven by a 15 MeV superconducting rf linac has been developed, and constructed at Tokai, JAERI since 1989. Cryogenic and accelerating fields' performances of four JAERI superconducting accelerator modules have been realized without any serious problem in the FEL accelerator vault and experimental hall. Since modification and related maintenance of the cryogenic refrigerator system for the driver were completed in the middle of October 1995, the system has run with no trouble, and the driver has been continuously run very successfully up to now. The optical resonator system and related electron beam transport system have been modified to realize larger acceptance than the old for both of the undulator radiation and energetic electron beam in 1995 Japanese fiscal year. In the modification, an alignment and distance measurement ...
Portal verification images were generated from the photon contamination in electron beams produced by a linear accelerator during treatment of patients receiving high-energy electron radiation therapy (8-14 MeV). An experimental storage phosphor system was used to record the images and display them on laser-printed film. Images were obtained from four or more treatment fractions from 21 cases of head and neck cancer. Precision in field placement was estimated by determining the position of a selected anatomic landmark relative to the center of the field for each series of images. The average standard deviation in the field-position measurements was 3.8 mm. Several procedural problems were also detected and corrected after review of the verification images. The results indicate that the emphasis placed on monitoring and control of field-positioning error in high-energy electron treatments should be ...
We propose to investigate the spontaneous emission of radiation arising out of the interaction of a relativistic electron beam with a metallic grating (the Smith-Purcell effect). The work will concentrate, primarily, in the 50-120 #mu#m part of the infrared spectrum and will be an extension of the work begun by the Oxford-Dartmouth-Essex collaboration; one of the early objectives of the project will be to develop a quantitative understanding of the power spectrum of the emitted radiation over a wide range of emission angles. In particular, the limits of relativistic peaking of forward directed emission will be investigated. The electron beam will be produced by laser irradiation of a metallic cathode in the terminal of a small Van de Graff accelerator located in the Technische Universitaet, Muenchen. Beam energies will be in the range of 2 - 4 MeV. Initial tests on photoproduction of electrons have ...
The effect of irradiation on the tensile properties of oil palm empty fruit bunch (OPEFB) fiber reinforced poly(vinyl chloride)/epoxidized natural rubber (PVC/ENR) blends were studied. The composites were prepared by mixing the fiber and the PVC/ENR blend using HAAKE Rheomixer at 150 deg. C. The composites were then irradiated by using a 3.0 MeVelectron beam machine at doses ranging from 0 to 100 kGy in air and room temperature. The tensile strength, Young's modulus, elongation at break and gel fraction of the composites were measured. Comparative studies were also made by using poly(methyl acrylate) grafted OPEFB fiber in the similar blend system. An increase in tensile strength, Young's modulus and gel fraction, with a concurrent reduction in the elongation at break (Eb) of the PVC/ENR/OPEFB composites were observed upon electron beam irradiation. Studies revealed that grafting of the OPEFB fiber with ...
The design and analysis of a high brightness electron beam experiment under construction at Sandia National Laboratory is presented. The beam energy is 12 MeV, the current 35 endash 40 kA, the rms radius 0.5 mm, and the pulse duration FWHM 40 ns. The accelerator is SABRE [J. Corley, J. A. Alexander, P. J. Pankuch, C. E. Heath, D. L. Johnson, J. J. Ramirez, and G. J. Denison, in Proceedings of the Eighth International IEEE Pulsed Power Conference, San Diego, California, 1991 (IEEE, New York, 1991), p. 920], a pulsed inductive voltage adder, and the electron source is a magnetically immersed foilless diode. This experiment has as its goal to stretch the technology to the edge and produce the highest possible electron current in a submillimiter radius beam. copyright 1996 American Institute of Physics.
The use of linear accelerators in radiotherapy is of great importance in Medicine, and according to international recommendations the electron beam dosimetry has to be performed using plane-parallel ionization chambers, previously calibrated in standard gamma radiation fields at accredited laboratories. In this work, calibration methods of plane-parallel ionization chambers used in dosimetry procedures of high energy electron beams of clinical accelerators were presented, tested and intercompared. The experiments were carried out using gamma radiation beams of {sup 60} Co at the Calibration Laboratory of Clinical Dosemeters at IPEN and electron beams od 4 to 16 MeV at the Radiotherapy Department of Hospital Israelita Albert Einstein, Sao Paulo. A method was chosen to be established at IPEN. Proposals of the calibration procedure, calibration certificate and data sheets are presented. (author)
The current primary standards at NPL for the measurement of absorbed dose to water in high energy photon and electron beams are graphite calorimeters. However, the quantity of interest in radiation dosimetry is absorbed dose to water. Therefore, a new absorbed dose to water standard based on water calorimetry has been developed for use in high energy photon and electron beams. The calorimeter operates at 4 deg C, with temperature control being provided by liquid cooling. The sealed glass inner vessel of the calorimeter was designed to minimise the effect of non-water materials on the measurement of absorbed dose. The temperature sensing thermistor probes were designed and constructed so that glass is the only material in contact with high purity water inside the vessel. Initial measurements of absorbed dose to water made in 6, 10, and 19 MV photons, and 16 MeVelectrons agreed, within the measurement ...
An extensive series of pulse height measurements have been performed in partially depleted Si surface barrier detectors, using various heavy ions (Li, B, C, O, Al and Cl), at energies between 5 and 70 MeV. After correcting for the small energy loss of the incident ions in traversing the gold surface barrier layer of the detector and for the residual nuclear stopping, the resulting pulse heights per MeV for the various heavy ions were found to be up to 2.5% larger than for the {sup 241}Am (5.486 MeV) alpha particle. This increase, although significant, is smaller than had been anticipated from an extrapolation of the earlier study of H, He and Li pulse heights by Lennard et al.. A new method of analysis of pulse height data, which significantly reduces the uncertainties associated with the dead layer energy loss and nuclear stopping corrections, was used in order to determine directly the variation of the average energy for ...
The term Smith-Purcell free electron laser can be employed generally to describe any coherent radiation source in which a diffraction grating is used to couple an electron beam with the electromagnetic field. To date, most practical developments of this concept have focused on devices which operate in the millimeter spectral regime. In this paper construction of a Smith-Purcell free-electron laser operating in the far-infrared (FIR) region using a novel resonator cavity design and the electron beam from a low energy (0.5-5 MeV) radio-frequency accelerator will be discussed. A tunable source in this region would have many applications and since the beam energy is low, the small size and low overall cost of such a device would make it a laboratory instrument. Current projects which are progressing towards developing a FIR source are the programs at Stanford and CREOL. Both of these ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
During the last decade, new radiopharmaceutical have been introduced for brain imaging. The marked differences of these tracers in tissue specificity within the brain and their increasing use for diagnostic studies support the need for a more anthropomorphic model of the human brain and head. Brain and head models developed in the past have been only simplistic representations of this anatomic region. For example, the brain within the phantom of MIRD Pamphlet No. 5 Revised is modeled simply as a single ellipsoid of tissue With no differentiation of its internal structures. To address this need, the MIRD Committee established a Task Group in 1992 to construct a more detailed brain model to include the cerebral cortex, the white matter, the cerebellum, the thalamus, the caudate nucleus, the lentiform nucleus, the cerebral spinal fluid, the lateral ventricles, and the third ventricle. This brain model has been included within a slightly modified version of the head model developed by ...
The importance of cellular dosimetry in both diagnostic and therapeutic nuclear medicine is becoming increasingly recognized. Experimental range-energy relations for electrons and alpha particles, along with derived geometric reduction factors, are used to calculate cellular absorbed fractions for these radiations. The resulting absorbed fractions are employed to calculate cellular S-values for several radionuclides. Cellular absorbed fractions for monoenergetic electron sources with energies ranging from 0.1 keV to 1 MeV, distributed uniformly in the source region, are calculated for several target {l_arrow} source combinations including cell{l_arrow}cell, cell{l_arrow}cell surface, nucleus{l_arrow}nucleus, nucleus {l_arrow}cytoplasm and nucleus {l_arrow}cell surface. Similar data are also provided for monoenergetic alpha particle sources with energies ranging from 3 to 10 MeV. S-values are also ...
A family of industrial irradiators is being developed by AECL to cover an electron-beam energy range from 5 to 18 MeV at beam powers between 20 and 250 kW. The IMPELA family of irradiators is designed for push button, reliable operation. The major irradiator components are modular, allowing for later upgrades to meet increased demands in either electron or X-ray mode. Interface between the control system, irradiator availability and dose quality assurance is in conformance with the most demanding specifications. The IMPELA irradiators use a klystron-driven, standing-wave, L-band accelerator structure with direct injection from a rugged, triode electron gun. Direct control of the accelerating field during the beam pulse ensures constant output beam energy, independent of beam power. The first member of the family, the IMPELA 10/50 (10 MeV, 50 kW), is in the final stages of assembly ...
Simulation irradiation experiments were carried out to investigate the formation processes and contribution to hardening of radiation-induced features in low alloy steels. Medium Cu (0.12 and 0.16%) and low Cu (0.03%) A533B steels were irradiated with 3 MeV Ni ions and 5 MeVelectrons, and in KUR at 290degC. Irradiated steels were examined by three-dimensional atom probe, positron annihilation, high-resolution transmission electron microscopy and hardness measurements. Electron irradiation caused almost the same hardening as KUR irradiation in medium Cu steels under almost the same dose rate and dose conditions, whereas the formation of larger, denser and more Cu enriched clusters and smaller accumulation of single vacancies were confirmed for KUR irradiation. This indicated that cascade damage provides additional cluster nucleation sites to compensate for lower free point defect ...
M-shell X-rays of the rare-earth elements {sub 60}Nd, {sub 64}Gd, {sub 67}Ho and {sub 71}Lu were measured for lithium ion bombardment in the energy range 1.0-6.0 MeV. The M-shell X-rays with energies of 0.978-1.631 keV were detected with a LINK analytical detector. The efficiency of the detector was determined by using the known atomic-field bremsstrahlung cross-sections from low energy electron beams and K-shell X-ray measurements with light projectiles. The measured cross-sections are compared to the predictions of the first Born approximation and the ECPSSR (energy loss and Coulomb deflection effects, perturbed stationary state approximation with relativistic correction) theories. The best theoretical description of the present data is given by the ECPSSR theory, even though the discrepancy between data and theory is increasing at higher projectile energies.
The inelastic energy losses for single collisions of Xe"+ ions with Xe targets have been measured for incident ion energies from 0.3 to 1.2 MeV and for scattering angles from 3"0 to 20"0. The energy losses were found to range from 1 to 11 keV with distinct steps at distances of closest approach of 0.22 and 0.12 A. By comparing these data with earlier ionization data by the same authors these steps are shown to be caused by M-shell excitation. Other excitations observed in the ionization data may be attributed to N-shell excitation. The distances of closest approach at which these excitations occur agree well with calculations by Eichler and Wille and co-workers, giving further evidence of the usefulness of Fano and Lichten's one-electron molecular model and these calculations.
Differential cross sections of elastic scattering of 104 MeV #alpha# particles from "2"0"4,"2"0"6,"2"0"8Pb have been measured with high angular accuracy. The analyses are based on a folding model treating the proton and neutron distributions independently. The proton distributions were taken from precise electron scattering results. The neutron distributions were parametrized by a modified Gaussian the parametrers of which were varied in order to fit the experimental cross sections. The resulting rms radii of the neutron distributions exceed the rms radii of the proton distributions by #DELTA#r=0.22 +- 0.09 fm for "2"0"4Pb, #DELTA#r = 0.19 +- 0.09 fm for "2"0"6Pb, and #DELTA#r = 0.30 +- 0.07 fm for "2"0"8Pb.
It is proposed to extract, independently of any nuclear model, the "4"0Ca matter density from an analysis of the elastic scattering of "1"6"6 MeV alpha particles. The scattering is described using an optical potential whose real part is evaluated by folding the matter density with a nucleon-alpha interaction. Following the procedure proposed by Sick (Nucl. Phys. A; 218: 509 (1974)) and Phys. Lett.; 44B; 62 (1975)) for the analysis of electron scattering data, the density is represented by a sum of gaussians whose amplitudes are deduced in fitting, via a chi"2 minimization, the experimental cross section data. This method determines the envelope of densities for different parameters of gaussians: width, spacing. The envelope of the moments of these densities are presented and the root-mean-square radius is extracted. It is concluded that only the nuclear surface is well studied by the alpha particle scattering. (author).
We have developed a Bragg curve counter (BCC) equipped with an active cathode to extend the energy acceptance to lower energies than for a conventional BCC to measure differential cross-sections of fragment production reactions induced by tens of MeV protons. The signal from the active cathode providing the timing signal of fragment incidence and the time difference signal between the cathode and anode gives information on the fragment range in the BCC on the basis of electron drift time. Utilization of the range information made possible identification of fragments less than 0.5 MeV/u that is lower than the identification threshold of a conventional BCC technique. After investigations on fundamental properties of a newly constructed BCC using heavy ion beams and alpha-particles, this method was applied successfully to a fragment production measurement for 70 MeV proton-induced reactions on carbon. With this technique, the ...
For the study of radiation biology and its application to radiotherapy, the double differential cross section of electron emission from water vapor induced by 6.0 MeV alpha particle beam is measured. The energy spectra of electrons ranging 7- 10000 eV are detected by the electrostatic analyzer and micro channel plate. The measurements are made at angles between 20 and 160 degrees. With use of this data set, the radial dose distribution in water is calculated by using KURBUC code. It is the Monte Carlo type code of the electron transport process, where the track of the electron is simulated through each individual interactions including elastic scattering, ionization cross section and total excitation cross section in case that electrons with certain energy are put in the liquid-density water. In order to understand the effect of radiation when the particle flux ...
Measurements were carried out for calibration and performance testing of a set of 10 electronic personal dosimeters (EPDs) at the Secondary Standard Dosimetry Laboratory of Sudan. Calibrations were carried out at three X-ray beam qualities described in ISO standard 4037 in addition to 137Cs and 60Co gamma ray beams. The experimental was performed with EPDs mounted on ICRU Slab phantom. X-ray and ?-ray beams were characterized in terms of air kerma free-in-air which were converted to the known delivered personal dose equivalent, Hp(10) using appropriate the air kerma to personal dose equivalent conversion coefficients. Dosimeters tested showed excellent energy and angular response and relative error of indication within the recommended limit for photon energies from 65 keV to 1.25 MeV. The study showed encouraging results for using electronic dosimeters in personal dosimetry.
Between 1984 and 1988, seven women with breast cancer were treated with intraoperative electron beam therapy (IOEBT). All patients were Caucasian. Patient age ranged from 37 to 62 (median 53) years. Histopathology was infiltrating duct carcinoma (6/7) or medullary carcinoma (1/7). Four tumors were staged T1 N0 MO, one T1 N1 MO, one T2 N1 MO, and one lesion was recurrent. At the time of primary lumpectomy or axillary node dissection, a dose of 10 or 15 Gy IOEBT was administered to the tumor bed with 6 or 9 MeVelectrons through the lumpectomy wound. All patients received 45 or 50 Gy over five to six weeks with 6 MV photons to the breast and, in four patients, to the regional nodes. Three patients received adjuvant chemotherapy and tamoxifen. No post-operative complications were observed. All patients are alive as of August, 1989, with no evidence of recurrent disease. Excellent cosmesis is the rule. Clinical and technical ...
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessivecurrent in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeVelectrons taking K1 is greatly enhanced for the approximate square-wave magnetic profile: the ratio of the power emitted at f=5 by the square-wave undulator to that of the ...
We have calculated the on-axis spectrum of spontaneous radiation emitted by an electron moving along a planar undulator that has a magnetic profile along the axis that approximates a square wave. (This could be obtained in practice by driving a ferromagnetic undulator into saturation by excessive current in the windings.) We find considerable enhancement of the harmonic radiation spectrum. We compare the harmonic power emitted by an electron moving through an undulator having a sine-wave field profile with the radiation emitted from an undulator having a square-wave profile; the latter is approximated by the first three Fourier components of the undulator magnetic field profile along the axial direction. Examples are computed for 40MeVelectrons taking K < 1, for spontaneous radiation emitted along the axis of the system. The emission at harmonics f > 1 is greatly enhanced for the approximate ...
In partnership with the US Navy, high-technology corporations, and research universities, Jefferson Lab is building a superconducting radio-frequency (SRF) accelerator-driven free-electron laser (FEL) and is outfitting an FEL user facility. This first fourth-generation light source - a 1 kW, 3 #mu#m infrared (IR) laser - is the first step in a program to develop high-average-power SRF-based IR and ultraviolet (UV) FELs for multiple manufacturing applications as well as for defense-related applied research and basic scientific research. This initial FEL will be driven by a 42 MeV, 5 m A recirculating SRF linac similar to the much larger SRF linac in Jefferson Lab's 4 GeV, 200 #mu#A Continuous Electron Beam Accelerator Facility (CEBAF). The FEL is expected to demonstrate 75% energy recovery. Its linac will be cooled by the existing CEBAF cryogenic system. At Jefferson Lab, an infrastructure of facilities and people already ...
The authors have designed and constructed four types of electron-beam diodes for the new 4-MV RLA injector: a non-immersed foilless diode, a magnetically immersed foilless diode, a foil diode and an ion-focused foilless diode, They are tailored to fit the new injector cavity. The design goals were to produce high quality 10-kA to 20-kA electron beams with a #beta# perpendicular smaller than 0.2 and a beam radius of the order of 2 cm. These beams will be matched to the RLA IFR channel so #beta# perpendicular must be equal to or smaller than the square root of the ratio of the beam current versus Alfven current for f_e = 1. A reentrant anode geometry was selected for the injector cavity design, because it offers substantial savings on the required amount of feromagnetic cores. The inner radius of the outside shell, now only 30 cm, would have been twice as large (60 cm) if a coaxial non-reentrant geometry had been adopted. The shape of the anode ...
Total skin electron beam therapy (TSEB) was used in the treatment of 33 patients with lymphoma and 13 patients with leukemia involving extensive segments of the skin surface. Twenty-two of 23 had lesions as a primary manifestation of lymphoma (primary cutaneous lymphoma-PCL) and 11 developed cutaneous lesions following disseminated nodal lymphoma (secondary cutaneous lymphoma-SCL). A once weekly fractionation scheme was employed to irradiate the entire skin surface with 3.5 to 4 MeVelectron beam from a 6 MeV linear accelerator. During each weekly session, 400 rad were delivered to the entire skin and a complete course consisted of 4-6 consecutive weekly sessions. The majority of patients have been previously treated elsewhere for various periods and all patients have been at risk for a median of 12 months, range from 12-117 months following TSEB. Striking predominance of the diffuse pattern (76%) was ...
The spectral characteristics of the Cherenkov radiation have been evaluated and converted to equivalent retinal irradiance from external sources. On the basis of the conversion, electron fluxes have been estimated for 2-sec recovery times from flashblindness. The electrons are assumed to have energies greater than 6 MeV and to be delivered in one or more bursts of 1 microsecond each over 1 sec. It is important to note that very little data exists on recovery times as short as 2 sec for either photopic and scotopic conditions. This situation is a direct result of the lack of definition of the critical tasks and their sensitivity to an interruption of background adaptation. The Cherenkov radiation produced within the eye by relativistic electrons can be compared to light from external sources by the relationships: 1 rad approx. = 4.6 scotopic td-sec and 1 rad approx. = 0.55 photopic td sec. Based on these ...
During the previous 9 months the major part of the Fusion-FEM has been constructed. The 2 MV Insulated Core Transformer, the electron gun, the accelerator, the focusing lenses and the undulator have been tested on-site. In the present - temporary - set-up, the electron beam line consists of a 12 A, 80 keV thermionic electron gun, a 2 MeV dc accelerator, beam transport optics, the undulator and a collector. The gun is mounted in the high voltage terminal, which is now at -2 MV, and the undulator and mm-wave system am at ground potential outside the SF{sub 6}-filled pressure tank. This so-called inverse set-up allows easy access to the larger part of the beam line, the undulator and the mm-wave system, which is important in the conditioning phase. The decelerator and depressed collector am not yet installed. The design of the electron beam line has been optimised using the GPS ...
Defect cluster formation in 14-MeV neutron irradiated polycrystalline copper has been observed by transmission electron microscopy (TEM) and correlated with the increase in yield stress. The measurements indicate that the radiation hardening component of the yield strength in polycrystals is not directly additive to the unirradiated yield strength. A transitional behavior was observed for radiation hardening at low fluences, which produces an anomalous variation of the defect cluster barrier strength with fluence. The behavior is attributed to the effect of grain boundaries on slip band transmission. An upper limit for the room temperature barrier strength of defect clusters in neutron-irradiated copper was determined to be #alpha#=0.23. (orig.).
Stage III and stage IV recovery have been investigated resistometrically following 6.1 MeV alpha-particle irradiation at 4.2 K. The activation energy associated with stage III shows a gradual increase from 0.35 +- 0.02 eV to 0.39 +- 0.02 eV. Stage IV (155 to 180 K) is associated with an activation energy of 0.46 +- 0.03 eV. The present results are compared with those obtained after electron and neutron irradiation. The stage III recovery kinetics are interpreted in terms of the Goesele-Seeger theory for interstitial migration in highly anisotropic hexagonal metals. Stage IV is ascribed to monovacancy migration. (author).
Making use of a lead slowing-down spectrometer coupled to a 46 MeVelectron linear accelerator and a back-to-back type double fission chamber, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, for which the evaluated and the experimental data were broadened by the energy resolution function of the spectrometer. (author)
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeVelectron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40 % full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer.
Making use of a back-to-back type double fission chamber and a lead slowing-down spectrometer driven by a 46 MeVelectron linear accelerator, the fission cross sections of Am-241, Am-242m and Am-243 have been measured relative to that of U-235 from 0.1 eV to 10 keV with the energy resolution of about 40% full width at half maximum. Each of the measured result has been compared with (1) the evaluated nuclear data in ENDF/B-VI and JENDL-3.2, and (2) the existing experimental data, whose evaluated and measured data were broadened by the energy resolution function of the spectrometer. (author)
Nano indentation analysis and transmission electron microscopy observation were performed to investigate a microstructural evolution and its influence on the hardening behavior in Fe-Cr alloys after an irradiation with 8 MeV Fe4+ ions at room temperature. Nano indentation analysis shows that an irradiation induced hardening is generated more considerably in the Fe-15Cr alloy than in the Fe-5Cr alloy by the ion irradiation. TEM observation reveals a significant population of the a0 dislocation loops in the Fe-15Cr alloy and an agglomeration of the 1/2a0 dislocation loops in the Fe-5Cr alloy. The results indicate that the a0 dislocation loops will act as stronger obstacles to a dislocation motion than 1/2a0 dislocation loops.
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al_xGa_1_-_xInP_2; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. copyright 1996 The American Physical Society.
Pulse radiolysis studies of the formation kinetics and the yields of various phenylcarbenium ions from several different solutes in 1,2-dichloroethane solution have been carried out. The results indicate that there are two kinetically distinguishable cationic species of the solvent which react selectively with the different solutes to form the phenylcarbenium ions. It is suggested that one is a cation radical (yield 0.68 molecule/100 eV) and the other a carbocation (yield 0.20 molecule/100 eV). Rate constants for their separate reactions with selected aromatic compounds and with ammonia have been determined. Molar extinction coefficients have been estimated for benzyl cation, diphenyl cation radical, and anthracene cation radical. 6 figures, 1 table.
Pd/n-Si and Pd/n-GaAs devices have been irradiated from high energy ({approx}100 MeV) heavy ions of Au{sup 7+} (gold) and Si{sup 7+} (silicon) to study the irradiation effects in these junction devices on semiconductor substrates. The devices have been characterized from I-V and C-V studies for electronic flow characterization. It has been found that the devices become high resistive on the irradiation and the substrates change the conductivity type from n- to p- on the irradiation of fluence of {approx}10{sup 12}-10{sup 13} ions/cm{sup 2}. The change in conductivity type has been understood as a result of creation of deep acceptors on the irradiation.
Bent specimens of A533B steel (0.16wt% Cu) were irradiated at 290degreeC to 1dpa with 6.4MeV Fe3+ ions. Calculated tensile stresses at the irradiated surface were set to 0, 250, 500 and 750MPa. The specimens were subjected to hardness measurements, transmission electron microscopy (TEM) observations and three-dimensional atom probe (3DAP) analysis. The radiation-induced hardening decreased with increasing stress to 500MPa which was near the yield strength. TEM and 3DAP results showed that well-defined dislocation loops and solute clusters were formed. The diameter of dislocation loops increased and the number density decreased when the stress was applied, whereas the diameter and number density of solute clusters decreased. The hardening was mainly attributed to solute cluster formation. A...
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd/sub 2/Si and NiSi/sub 2/ layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd/sub 2/Si layers was found to saturate at doses between 3 x 10/sup 14/ and 1 x 10/sup 17/ ions/cm/sup 2/, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi/sub 2/ layers became amorphous at doses higher than 3 x 10/sup 15/ ions/cm/sup 2/. These results were confirmed by the reflection electron diffraction analyses.
Channeling effect measurements have been employed to investigate radiation damage produced by 100-keV Ar ions in preferred oriented polycrystalline metal-silicide layers, such as Pd_2Si and NiSi_2 layers formed on single-crystalline Si. For room-temperature implantation, an amount of the damage in Pd_2Si layers was found to saturate at doses between 3 x 10"1"4 and 1 x 10"1"7 ions/cm"2, where the minimum aligned yield of 1.5-MeV He ions was nearly 40% of the random one. On the contrary, it was observed that the NiSi_2 layers became amorphous at doses higher than 3 x 10"1"5 ions/cm"2. These results were confirmed by the reflection electron diffraction analyses.
Abstract We suggest a simple scheme for automatically determining the width parameter of smearing methods of the Brillouin zone integration in electronic structure calculation. The scheme retains one free parameter that at any time can be eliminated by choosing a denser k-space mesh until the desired accuracy is obtained. The tests are carried out in the context of Methfessel-Paxton smearing. This adaptive Gaussian smearing (AGS) is easily implemented, variational with respect to partial occupancies and free from spurious occupancies that are negative or larger than one. Its convergence properties are similar to those obtained with the modified tetrahedron method for energy resolution of -0.1 meV. 2010 Wiley Periodicals, Inc. Int J Quantum Chem, 2011
The swelling behavior which results from simulated fusion environment irradiation of Fe-10% Cr has been characterized with transmission electron microscopy. Specimens were bombarded at 850 K with: a ''triple-beam'' of He"+, D_2"+, and 4 MeV Fe"+"+ ions to 0.3, 1, 3, 10, 30, and 100 dpa (displacement per atom); a ''dual-beam'' of He"+ and 4 MeV Fe"+"+ ions to 30 and 100 dpa; and a ''single-beam'' of 4 MeV Fe"+"+ ions to 30 dpa. The helium and hydrogen injection rates were approx. =10 appm He/dpa and approx. =40 appm D/dpa. Cavities were observed for damage levels of 3 dpa and greater. The swelling was <0.1% for damage levels <30 dpa, but at 100 dpa, there was an increase in the swelling to 2.5% for the ''triple-beam'' irradiation and 1.2% for the ''dual-beam'' irradiation. The swelling rates between 30 and 100 dpa correlate well with calculated values assuming a steady-state swelling-rate regime ...
This report of progress and future objectives timetable is based on an included schematic of goals and objectives and the project abstract which is included as Appendix 1. Five matters are summarized in the order of (1) novel methods of calcified bone confocal microscopy and reconstruction image analysis of decalcified beagle and human cortical bone serial sections, (2) macroscopic cross-correlation of beagle and human cortical and cancellous bone fractions with CT analysis, (3) guidance to the most radiobiologically important skeletal regions of interest with the just completed {sup 90}Sr bone tumor map from life time beagle studies, (4) deposition patterns of radioactive agents that participate in apatite crystal nucleation processes in bone and leave radiation-excited electrons trapped in bone mineral, and (5) the budget period timetable. The discovery that beta particles from {sup 166}Ho (T{sub {1/2}} =26 hr, {beta}{sub max} = 1.8 MeV) ...
The principal paradigm for gamma-ray bursts (GRBs) suggests that the prompt transient gamma-ray signal arises from multiple shocks internal to the relativistic expansion. This paper explores how GRB prompt emission spectra can constrain electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The array of possible high-energy power-law indices in accelerated populations is highlighted, focusing on how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. When encompassing the MeV-band spectral break, fits to BATSE/EGRET burst data indicate that the preponderance of electrons responsible for the prompt emission reside in an intrinsically non-thermal population. This differs markedly from typical populations generated in acceleration simulations; potential resolutions of this conflict such as the action ...
This work is a retrospective study of 86 patients with squamous cell (51) and basal cell (35) carcinoma of the face. The median age was 67 years. The staging is as following: 31 cases T{sub 1} and T{sub 2}, 55 patients T{sub 3} and T{sub 4}. All patients were considered NO. Electron beam was used in all cases and energy ranged from 5 to 15 MeV depending on the thickness of the tumor. The total tumor dose was 60-70 Gy delivered in 6 weeks. In 7 cases of very old patients the authors have used concentrated irradiation: 3 patients received 21 Gy in one fraction and 4 patients 48 Gy in 8 fractions. 96.8% patients T{sub 1} i T{sub 2} are NED contrary to 56.4% T{sub 3} i T{sub 4}. Cosmetic results were considered as good in 52, fairly good in 7 and bad in 2 patients.
The purpose of this study is to determine the suitability of producing agro-fiber reinforced plastic composite (agro-FRPC) from rubber wood fiber blended in polypropylene matrix. The effects of varying fiber dimension and fiber content on the physical and mechanical properties of the composite were evaluated to provide an insight into the fiber matrix adhesion. The effects of reactive additives on the physical and mechanical properties of the composite were evaluated which provides the insight on the reinforcement of the composite. Rubber wood fiber used in this study is currently being used in the manufacturing of medium density fiber (MDF) board. Two sizes of rubber wood fiber were used i.e. 0.5-1.0 mm and 1.0-2.0 mm. Homopolymer polypropylene of MFI 14.0 was used as a matrix. The irradiation work was carried out using electron beam accelerator, 3.0 MeV, 3.0 mA. Various types of reactive additives (RA) with mono-functional, di-functional, ...
The industrial radiation processing using low energy electron beam (EB) accelerators lower than 300 keV offers high speed, safe technologies for the chemical conversion of thin layer coatings. Because of the nonselective mode of initiating chain reaction polymerization involving free radicals in synthetic coating layers and suitable substrates, the EB curing of the coatings on woods and papers has particular advantage. Hungary decided to start an up-to-date EB line to process cement-bound (CB) wood chipboards with pigmented acrylic coatings. The CB wood chipboards contain more than 60 % of portland cement and up to 40 % of wood particles. They are produced as large boads of 6 - 16 mm thickness. In their fireproof character and other aspects, they are similar to asbestos-cement boards without containing carcinagenic asbestos, and are stable against moisture and atmospheric influences. EB-cured acrylate coating improved further those properties, and makes them ...
The National Bureau of Standards' (NBS) CW racetrack microtron (RTM) will be utilized as a driver for a free electron laser (FEL) oscillator. The NBS RTM possesses many exceptional properties of value for the FEL: i) CW operation, ii) energy from 20-185 MeV, iii) small energy spread and emittance, iv) excellent energy stability, and v) high average power. The 1-D FEL gain formula predicts that the FEL would oscillate at the fundamental approximately from 0.25 #mu#m to 10 #mu#m when up-grading the peak current to #>=# 2 A. In this paper, the authors present 3-D self-consistent numerical results including several realistic effects, such as emittance, betatron oscillations, diffraction and refraction. The results indicate that the design value of the transverse emittance is small enough that it does not degrade the FEL performance for intermediate to long wavelengths, and only slightly degrades the performance at the shortest wavelength under ...
The Linac Coherent Light Source (LCLS) is an x-ray free-electron laser (FEL) project based on the SLAC linac. The LCLS Photoinjector beamline has been designed to deliver 10-ps long electron bunches of 1 nC with a normalized projected transverse emittance smaller than 1.2 mm-mrad at 135 MeV. Tolerances and regulation requirements are tight for this tuning. Half of the total emittance at the end of the injector comes from the ''cathode emittance'' which is 0.7 mm-mrad for our nominal 1nC tuning. As the ''cathode emittance'' scales linearly with laser spot radius, the emittance will be dramatically reduced for smaller radius, but this is only possible at lower charge. In particular, for a 0.2 nC charge, we believe we can achieve an emittance closer to 0.4 mm-mrad. This working point will be easier to tune and the beam quality should be much easier to ...
These experiments were performed on the Isocele separator, on-line with the Orsay synchrocyclotron; thulium isotopes were produced by bombarding natural erbium targets with 150nA beam of 157MeV protons. Two Ge(Li) detectors, with resolution of 2.3 and 2.5keV at 1332keV used for #gamma#-ray measurements; conversion electron spectra were measured using a Si(Li) detector. #gamma# spectra, #gamma#-#gamma# coincidence and conversion electron measurements were sufficient to build the flow energy level schemes of the transitional "1"5"8Er and "1"5"6Er nuclei. On both nuclei several quasi rotational bands have been identified. These results are compared with other even erbium isotopes and with the neighboring N=88 and 90 isotones. Comparisons with predictions issued from some classical models are also performed: "1"5"8Er appears as a deformed nucleus very similar to "1"6"0Er and "1"6"2Er; on the other hand "1"5"6Er seems to be a ...
Free-electron laser (FEL) experiments have been conducted with the 38-MeV L-band electron linac at the Institute of Scientific and Industrial Research, Osaka University. It is a 1.3 GHz RF linac with a thermoionic gun, and equipped with two 12th and one 6th sub-harmonic prebunchers for producing the high-intensity single-bunch beam with a charge up to 67 nC/bunch. For oscillation experiments of FEL, the gun is replaced with that with a smaller cathode area in order to reduce the emittance of the beam. The normalized emittance has been measured to be 200 {pi} mm-mrad. The linac is operated in the long-pulse mode and one of the 12th sub-harmonic bunchers and the 6th sub-harmonic buncher are operated, so that the time duration of the macropulse is 4 {mu}s and the spacing between micropulses is 9.2 ns. The length of the micropulse is 30-40 ps and the charge in each micropulse is 2 nC. The electron beam from ...
Electron beams as a source of directed energy are under study at the Lawrence Livermore National Laboratory (LLNL). An intense 10-kA, 50-MeV, 50-ns full-width half-maximum, pulsed electron beam is generated by the prototype Advanced Test Accelerator (ATA) at the Laboratory's Site 300. Whenever the electron beam is stopped in materials, intense radiation is generated. Estimates based on available data in the literature show that for materials such as lead, photon radiation (x ray, gamma, bremsstrahlung) levels can be as large as 10"4 roentgens per pulse at 1 m in the zero-degree direction (i.e., the electron-beam direction). Neutrons, which are emitted isotropically, are produced at a level of 10"1"3 n/m"2 per pulse. Depending upon the number of pulses and the shielding geometry, the accumulated dose is potentially lethal to personnel and potentially damaging to instrumentation that ...
Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2"+_1 level in "8"8Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.
Si and Si/P ion implantation doping of In{sub 0.5}Ga{sub 0.5}P and In{sub 0.5}Al{sub 0.5}P has been studied for several Si and P doses at energies of 90 and 100 keV, respectively. For single Si implants in InGaP a maximum Hall sheet electron concentration of 1.33{times}10{sup 13} cm{sup {minus}2} is achieved for a Si dose of 5{times}10{sup 13} cm{sup {minus}2}. When an optimum dose (2.5{times}10{sup 13} cm{sup {minus}2}) P coimplant is performed this electron concentration is increased by 65{percent}. The same dose Si implants in InAlP show a maximum effective activation of 3.9{percent} with no P coimplantation and 5.2{percent} with a P-implant dose 1.5 times the silicon dose. The apparent donor ionization energies are estimated from variable temperature Hall measurements to be 2{endash}5 meV for InGaP and {approximately}80 meV for InAlP. The deeper level in InAlP is attributed to the DX level found in ...
The effects of extended source-to-surface distance (SSD) on the electron beam dose profiles were evaluated for various electron beam energies - 6, 9, 12, 15 and 20 MeV - and the accuracy of various output correction methods was analysed on a Mitsubishi linear accelerator using a radiation field analyser (RFA). The dose fall-off region of the central axis depth-dose curves was nearly independent for SSDs up to 120 cm where as in the build-up region, a marginal reduction of surface dose was observed, particularly for lower energies and for smaller field sizes. Effective SSDs and virtual source distances were evaluated for field sizes ranging from 5x5 to 15x15 cm"2 for various energies. Curve fitting was done with the measured outputs with various equations and coefficients were evaluated. The accuracy of the derived output correction factors by effective SSD, virtual source distance and curve-fit methods was assessed by ...
A magnetic measuring technique, which sorts out defects according to a distribution function n, was used to study the influence of electron irradiation on 50-50 NiFe. The distribution function is determined in terms of the maximum force f/subm/ that a defect can exert on a forward moving domain wall, or equivalently, the range z_0, which is the distance the mean position of the wall may move past the defect before the wall snaps free from the pinning action of the defect. The range and maximum force are related by a spring constant k, viz., f/subm/=kz_0. The quantity n (z_0) dz_0 gives the number of defects per unit volume having a range between z_0 and z_0+dz_0. Distribution functions were determined before and after electron irradiation. The irradiation was for 100 min with 18-MeVelectrons with a dose of 1.1times10"1"7 e/cm"2. Following irradiation, there was a substantial decrease in the number of ...
A unique beam of pulsed electrons has been developed using the 19-MeV, 700-kA Hermes-III accelerator. The extended planar-anode diode is used to extract at large radius an annular electron beam from the accelerator and inject the resulting beam at small angle into a low-pressure gas cell, where the beam is rapidly charge neutralized and almost current neutralized. Under these conditions, the beam propagates nearly ballistically to a focus downstream of injection, where objects can be placed for irradiation and study. For a focal length of 78 cm, measurements with a segmented calorimeter show that this configuration can deliver an energy deposition of 200 J/g [20 Mrad] over a useful area of 70 cm{sup 2} and a 4-cm depth in graphite in 25 ns. Increasing the injection angle by reducing the AK gap permits higher doses over smaller areas to be achieved. Such beams are of interest for the study of material property changes from ...
A next generation e"+-e"- linear collider in the TeV range can be converted into a #gamma#-#gamma# collider by converting it to e"--e"- operation and then generating #gamma#-rays via Compton backscattering with optical beams. This provides unique access to some areas of fundamental physics as well as highly desirable redundancy to the collisions. The required optical beam (with a wavelength of about 1 micron) must have very high peak power, (about 1 TW) as well as average power (about 10 kW). To achieve a 1 : 1 conversion from an electron to #gamma#-quantum, each micropulse must contain about one Joule and must be about one picosecond long, the micropulse peak power being about one Terawatt. To match the electron beam pulse structure, a macropulse consists of a sequence of about one hundred micropulses separated by about one nanosecond, and the macropulses am repeated at a rate of about 100 Hz. Thus, the time average power is about 10 kW ...
A 20-MeV proton accelerator is developed by Proton Engineering Frontier Project (PEFP) at Korea Atomic Energy Research Institute (KAERI). The 20MeV accelerator consists of 50keV proton injector, 3MeV RFQ (Radio frequency Quadrupole), 20MeV DTL (Drift Tube Linac) and 20MeV beam line. The beam profile was measured at the end of the 20MeV beam line with wire scanner. Moreover the beam emittance was calculated from the quad scan method using beam line quadrupole magnets. In this paper, the beam profile measurement results are presented and the emittance measurement from the quad scan method is discussed
Characterization of high temperature superconducting film and bulk samples has been carried out using 2 MeV [alpha]-particle Rutherford backscattering, 2.4 MeV proton elastic scattering, 2.4 MeV proton-induced x-ray emission, 9 MeV proton induced [gamma]-ray emission and 100 MeV iodine elastic recoil detection analysis techniques. The objective was to compare different ion beam based techniques for: (i) compositional analysis; and (ii) consistency of the results obtained for samples prepared using similar preparation methodology. (author).
In radiation processing of food, the product often has to be prepackaged to prevent microbial recontamination during and after irradiation. The packaging material is exposed to radiation during radiation processing and radiation stability is a key consideration in the selection of packaging materials. The effects of ionizing radiation on many food packaging materials at the dose levels recommended for food precessing can be minimized by selecting appropriate radiation resistant materials. It is important to select materials in which chemicals formed as a result of the radiation treatment do not migrate and interact with the food, affecting its organoleptic and toxicological aspects. It is also important to select materials in which the physical properties are not altered to the extent they cannot resist damage during commercial production, shipment and storage. Radiation treatment of food may be classified broadly into two categories: 1. Processes requiring doses less than 10 kGy; 2. ...
M-shell x-ray production cross sections for selected heavy elements, namely, _7_2Hf, _7_3Ta, _7_4W, _7_5Re, _7_6Os, _7_7Ir, _7_8Pt, _7_9Au, _8_3Bi, and _9_0Th, were measured for protons of energy 0.6--4.0 MeV. The experimental results are compared with the predictions of the first Born and semiclassical approximations for M-shell ionization; these data are also compared with the theory that accounts for the projectile's energy loss and Coulomb deflection as well as for the target's M-shell electron perturbed stationary state and relativistic nature (ECPSSR). Generally, fair agreement between the data and the ECPSSR theory is found. Some systematical discrepancies observed for the lightest elements (Hf, Ta, and W) are explained as possible ambiguities in the M-shell Coster-Kronig factors and fluorescence yields, which were used to convert theoretical M-subshell ionization cross sections to the total M-x-ray production cross sections. The ...
K and L-shell x-ray production cross sections were measured using #alpha#-particle beams of 14.00 to 34.16 MeV. The K-shell measurements ranged from Z = 20 to Z = 50 and included Ca, Sc, Ti, V, Fe, Ni, Cu, Zn, Ga, Br, Rb, Sr, Y, Mo, Ag, In, and Sn while the L-shell measurements ranged from Z = 55 to Z = 92 and included Cs, Ba, Ce, Gd, Tm, Lu, Au, Pb, Th, and U. Thin metallic foils were used for the measurements and corrections for self-attenuation were negligible. A liquid nitrogen cooled Si(Li) detector and associated pulsed optical electronics were used in detecting x-rays. Absolute cross sections with an uncertainty of +-10 percent are presented for the elements measured. Also smoothed cross sections are presented which were generated by a three term polynomial fit of the experimental data points. By use of available fluorescence yields the K-shell data were converted to ionization cross sections and compared to various theoretical models. ...
The transmutation of minor actinides in-reactor is one solution currently being studied for the long time management of nuclear waste. In the heterogeneous concept the radionuclides are incorporating in an inert ceramic matrix. The support material must be insensitive to radiation damage. Fission product damage is the main radiation damage source during the transmutation process and therefore it is of the utmost importance to study their effects. We irradiated spinels MgAl_2O_4 (matrix of reference) and ZnAl_2O_4 by fast ions (by example: (86)Kr of approximately 400 MeV) simulating the fission products. Under these conditions, the damage is primarily due to the electronic energy losses (Se). One of the structural features of spinel AB_2O_4 is that the two cations (A(2+) and B(3+)) can exchange their site. This phenomenon is quantified by the inversion parameter. We highlight by XRD in grazing incidence that the structural changes observed in ...
We have investigated the generation and propagation of misfit dislocations in strained In/sub y/Ga/sub 1-//sub y/As/GaAs multiquantum wells grown by molecular-beam epitaxy, with cross-sectional transmission electron microscopy. The samples are of excellent optical quality, with multiquantum wells having well widths of 100 A, being characterized by excitonic linewidths and Stokes shifts of 1.5--2.5 and 1--2 meV, respectively. We have examined the growth of 2-..mu..m-thick multiquantum-well samples grown either directly on GaAs, or with an intermediate composition buffer layer, and for the cases of small (y = 0.07) and large (y = 0.16) misfits. It is seen that for the case of quantum wells with small misfit, grown directly on GaAs, metastable growth can be achieved. This is confirmed by low-temperature absorption measurements and from transmission electron microscopy experiments performed both before and after post-growth ...
Two children with cutaneous lymphoma and leukemia who were treated with total skin electron beam therapy (TSEB) are described here. Patient 1. A 7-year-old boy was admitted because of a mass over the bilateral parotis and anemia. The white blood cell count on admission was 5,000/ul. Bone marrow examination revealed 70 per cent monoblasts (M5a type by FAB classification). Complete remission was obtained following the regimen of daunomycin, cytosine arabinoside, 6-mercaptopurine and prednisolone. He was again admitted because of a skin nodule on the left thigh 19 months after initial diagnosis. A biopsy of the skin nodule demonstrated monoblastic infiltration. He received 20 Grays (Gy) to the left thigh and this led to resolution of the skin nodule. At that time, other skin nodules appeared on the right upper and lower extremities. He was treated with TSEB. Daily doses of 1 Gy were given twice a week with a 4 MeVelectron ...
This work presents a study of the {sup 1}P{sup 0} excited states of He that can be reached by absorption of a single photon carrying an energy close to the double ionization threshold (DIT) (79 eV). Above the DIT, these states are the double continuum states; below, they are the double excited states. These two types of states are tightly coupled to the single continuum states with or without excitation of the residual ion He{sup +}, owing to their degeneracy in energy. In a one-photon process, these states can only be formed owing to the electronic correlations in the system which must be well described to obtain quantitative good results. Our study is a part of the work which aims at a united description of all these doubly excited, ionized-excited, and double continuum states. We use the Hyperspherical R-Matrix with Semiclassical Outgoing Waves (HRM-SOW) method, initially dedicated to double photoionization studies. We extend it to extract information on the ...
Doping of molecular organic materials is important for the functionality of organic electronic devices as e.g solar cells. We investigated the doping behaviour of the acceptor molecules Cl{sub 2}-DCNQI and F{sub 16}CuPc incorporated into a CuPc matrix. In-situ XPS/UPS measurements were performed on coevaporated films. Doping by Cl{sub 2}-DCNQI was not successful. The molecule lost its chlorine atoms during thermal evaporation. For pristine F{sub 16}CuPc layers we observe a strong broadening of the photoemission features with increasing deposition rate indicating different domains probably of different molecular structure of differing electric interface potential. F{sub 16}CuPc incorporated into CuPc shows sharp photoemission features. With increasing F{sub 16}CuPc content Fermi level shifts are observed in both phases. In CuPc the maximum shift is about 0.45 eV towards the HOMO level indicating p-doping. Simultaneously the Fermi level in F{sub 16}CuPc shifts 0.15 ...
It is widely accepted that the prompt transient signal in the 10 keV - 10 GeV band from gamma-ray bursts (GRBs) arises from multiple shocks internal to the ultra-relativistic expansion. The detailed understanding of the dissipation and accompanying acceleration at these shocks is a currently topical subject. This paper explores the relationship between GRB prompt emission spectra and the electron (or ion) acceleration properties at the relativistic shocks that pertain to GRB models. The focus is on the array of possible high-energy power-law indices in accelerated populations, highlighting how spectra above 1 MeV can probe the field obliquity in GRB internal shocks, and the character of hydromagnetic turbulence in their environs. It is emphasized that diffusive shock acceleration theory generates no canonical spectrum at relativistic MHD discontinuities. This diversity is commensurate with the significant range of spectral indices discerned in ...
Primordial black holes are unique probes of cosmology, general relativity, quantum gravity and non standard particle physics. They can be considered as the ultimate particle accelerator in their last (explosive) moments since they are supposed to reach, very briefly, the Planck temperature. Upper limits on the primordial black hole number density of mass $M_{\\star} = 5 10^{14}$ g, the Hawking mass (born in the big-bang terminating their life presently), is determined comparing their predicted cumulative $\\gamma$-ray emission, galaxy-wise, to the one observed by the EGRET satellite, once corrected for non thermal $\\gamma$-ray background emission induced by cosmic ray protons and electrons interacting with light and matter in the Milky Way. A model with free gas emissivities is used to map the Galaxy in the 100 MeV photon range, where the peak of the primordial black hole emission is expected. The best gas emissivities and additional model ...
The Micro-strip Metal Foil Detectors (MMFD) designed and used for the Beam Profile Monitoring (BPM) are discussed. The results obtained for the MMFDs produced by different technologies are presented. The MMFD deposited onto the 20 {mu}m thick Si-wafer has been used for the BPM of the 32 MeV alpha-particle beam at the MPIfK (Heidelberg) Tandem generator. Another MMFD with totally removed Si-wafer at the working area has been applied for the on-line X-ray BPM at the HASYLAB (DESY). One may conclude that the developed technology of the micro-strip metal detector manufacturing allows to provide non-destructive measurement of X-ray intensity distribution over area of up to 50 mm{sup 2} with an accuracy of 10-20 {mu}m with a possibility of its improvement by a factor 5. A sub-micron position resolution is expected by applying electron lithography for the strip pattern production.
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 ..mu..g of /SUP 242m/ Am, one deposit of 168 ..mu..g /sup 235/U, and a ''weightless'' deposit of /sup 252/Cf, which served as a monitor of chamber performance. The fission of /sup 235/U, served as the cross-section standard for energies above 101 keV while /sup 6/Li(n,..cap alpha..), normalized to /sup 235/U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was ...
The fission cross section of /SUP 242m/ Am has been measured from 0.005 eV to 20 MeV using time-of-flight techniques at the Oak Ridge Electron Linear Accelerator. A hemispherical plate fission ionization chamber with five pairs of plates contained three deposits totaling 507 #mu#g of /SUP 242m/ Am, one deposit of 168 #mu#g "2"3"5U, and a ''weightless'' deposit of "2"5"2Cf, which served as a monitor of chamber performance. The fission of "2"3"5U, served as the cross-section standard for energies above 101 keV while "6Li(n,#alpha#), normalized to "2"3"5U fission in the 7.8- to 11.0-eV interval, served as a shape standard below 101 keV. Approximately 360 h of data were obtained at a flight path distance of 9.1 m, primarily with 40-ns bursts. Particular attention was paid to correction of backgrounds, especially inscattered-neutron-induced events. The fission resonance integral was found to be 1800 + or - 65 b.
Buried silicon carbide (SiC) microstructures with lateral dimensions in the #mu#m range were formed by high-dose projection of 1.5 MeV C"2"+ ions in Si(100) at different doses and temperatures and subsequent annealing for 10 h at 1250 deg. C. Sections of individual SiC microstructures were prepared for cross-sectional transmission electron microscopy (TEM) analysis using a focused ion beam (FIB). Besides the possibility to select an individual microstructure, the FIB technique has the advantage of producing specimen foils of uniform thickness. Therefore, it was possible to map the carbon concentration of microstructures by energy filtered TEM (EFTEM) using the C_K absorption edge without the need of any sample thickness correction. Local overstoichiometric (>50%) carbon concentrations are shown to be correlated to the formation of an amorphous phase in the SiC and to significant swelling visible at the Si wafer surface 2 #mu#m above.
Efficient, low-temperature conversion of infrared light into visible light (red, orange, green) is reported at single heterojunctions and undoped quantum wells of GaAs and ordered Al{sub {ital x}}Ga{sub 1{minus}{ital x}}InP{sub 2}; an increase in photon energy of 700 meV is obtained. The signal originates from the high-band-gap layers and disappears only if the excitation energy is tuned below the GaAs band gap. The intensity of the up-converted photoluminescence (PL) is found to decrease significantly slower with increasing temperature than that of the regular PL and it remains observable up to 200 K. Interface-induced cold Auger processes along with the presence of trapped states for both electrons and holes in these ordered alloys account for this nonlinear mechanism. A colinear double-beam experiment confirms this. {copyright} {ital 1996 The American Physical Society.}
Ten different alloys of zirconium have been tested with regard to the effect of irradiation on their mechanical properties and their sensitivity to environmentally induced failure. Two different environments were used: iodine vapour and liquid cesium with an addition of 2% cadmium. The neutron dose was 10"2"1n/cm"2 (E>1MeV) and the irradiation temperature was about 300 degrees C. All alloy additions increased the irradiation hardening. Especially notable was the large effect of titanium and tin on irradiation hardening. A limited amount of transmission electron microscopy was carried out in order to find an explanation to the effects. The testing in different environments showed that there is no clear correlation between environmental sensitivity and yield stress. For materials of similar yield stress an alloyed material tends to be more sensitive to environmental cracking than a material which only contains oxygen as an impurity. There also ...
High aspect ratio sub-#mu#m periodic structures fabricated by focused ion beam (FIB) lithography have been characterised by Rutherford backscattering spectrometry (RBS) using the macrochannelling technique. The technique overcomes the limitations of complementary techniques such as scanning electron microscopy (SEM) and atomic force microscopy (AFM), which can provide images with sub-#mu#m resolution of just the surface features and not of the deep sub-surface structures, without destructive cross sectioning of the sample. Here RBS macrochannelling with a 2 MeV He"+ ion beam is used to analyse a diffraction grating fabricated by FIB milling an array of 100 nm wide trenches in a 300 nm thick Ag film on a Si substrate. Using the surface structure imaged by SEM and AFM as a starting point, a numerical model for the RBS spectrum from the grating is fitted to the experimental spectrum as a function of the sub-surface structure. This process allows ...
The paper describes a concept of extracting fusion power from D-{sup 3}He fueled IEC (Inertia Electrostatic Configuration) devices. The fusion system consists of a series of fusion modules and direct energy converters at an end or at both ends. This system of multiple units is linear and is connected by a magnetic field. A pair of coils anti-parallel to the magnetic field yields a field-null domain at the center of each unit as required for IEC operation. A stabilizing coil installed between the coil pairs eliminates the strong attractive force between the anti-parallel coils. Accessible regions for charged particle trajectories are essentially isolated from the coil structure. Thus, charged particles are directed along magnetic field lines to the direct energy converter without appreciable losses. A direct energy converter unit designed to be compatible to this unique system is also described. It basically consists of a separator and a traveling wave converter. A separator separates ...
The giant resonance regions of {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb were investigated using 240 MeV {alpha} particle scattering at small angles including 0 deg. E1 strengths corresponding to 91{+-}11%, 89{+-}10%, 105{+-}12% and 95{+-}13% of the isoscalar E1 energy-weighted sum rule were identified between 18{<=}E{sub x}{<=}31 MeV, 16{<=}E{sub x}{<=}30 MeV, 15{<=}E{sub x}{<=}27 MeV and 15{<=}E{sub x}{<=}25 MeV with centroid energies of 24.8{+-}0.4 MeV, 22.5{+-}0.3 MeV, 21.6{+-}0.3 MeV and 19.3{+-}0.3 MeV and rms widths of 3.2{+-}0.2 MeV, 3.5{+-}0.2 MeV, 3.2{+-}0.2 MeV and 2.5{+-}0.2 MeV for {sup 90}Zr, {sup 116}Sn, {sup 144}Sm and {sup 208}Pb, ...
The giant resonance regions of "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb were investigated using 240 MeV #alpha# particle scattering at small angles including 0 deg. E1 strengths corresponding to 91#+-#11%, 89#+-#10%, 105#+-#12% and 95#+-#13% of the isoscalar E1 energy-weighted sum rule were identified between 18#<=#E_x#<=#31 MeV, 16#<=#E_x#<=#30 MeV, 15#<=#E_x#<=#27 MeV and 15#<=#E_x#<=#25 MeV with centroid energies of 24.8#+-#0.4 MeV, 22.5#+-#0.3 MeV, 21.6#+-#0.3 MeV and 19.3#+-#0.3 MeV and rms widths of 3.2#+-#0.2 MeV, 3.5#+-#0.2 MeV, 3.2#+-#0.2 MeV and 2.5#+-#0.2 MeV for "9"0Zr, "1"1"6Sn, "1"4"4Sm and "2"0"8Pb, respectively. Parameters obtained for the isoscalar giant monopole resonance, ...
The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1 MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.
as for direct energy conversion in specialized direct electrical energy conversion plants. Figure 1. An energetic (~163KeV) proton and a 11boron nucleus fuse ...
Optimization of radiation shielding for a medium energy accelerator with 60 MeV alpha ions is carried out using the cost-benefit approach. Cost optimum shield thicknesses are estimated for different operating conditions of the accelerator. (author). 5 refs, 1 tab.
The MTX explored the plasma heating effects of 140 GHz microwaves from both Gyrotrons and from the IMP FEL wiggler. The Gyrotron was long pulse length (0.5 seconds maximum) and the FEL produced short-pulse length, high-peak power, single and burst modes of 140 GHZ microwaves. Full-power operations of the IMP FEL wiggler were commenced in April of 1992 and continued into October of 1992. The Experimental Test Accelerator H (ETA-II) provided a 50-nanosecond, 6-MeV, 2--3 kAmp electron beam that was introduced co-linear into the IMP FEL with a 140 GHz Gyrotron master oscillator (MO). The FEL was able to amplify the MO signal from approximately 7 kW to peaks consistently in the range of 1--2 GW. This microwave pulse was transmitted into the MTX and allowed the exploration of the linear and non-linear effects of short pulse, intense power in the MTX plasma. Single pulses were used to explore and gain operating experience in the parameter space of the ...
In earlier works, the inelastic mean free path (IMFP) of electrons was determined by elastic peak electron spectroscopy (EPES) using Ni and Ag reference standard samples, but fully neglecting surface excitation. Surface excitation that is characterized by the surface excitation parameter (SEP), and may affect considerably the elastic peak for the sample and the reference material. The SEP parameters of selected conducting polymers (polythiophenes, polyaniline and polyethylene) were determined by EPES using Si and Ge reference samples. Experiments were made with a hemispherical analyzer of energy resolution 100-200 meV in the E = 0.2-2.0 keV energy range. The composition of the sample surfaces was determined by in situ XPS, their surface roughness by AFM. The experimental SEP parameter data of eight polymer samples were determined by our new procedure, using the formulae of Chen and Werner et al. in the E = 0.2-2.0 keV ...
Jlab experiment E01-011, carried out in 2005 in JLab Hall C, is the second generation of the hypernuclear spectroscopy experiments by the (e,e{prime}K{sup +}) reaction. The (e,e{prime}K{sup +}) reaction is complimentary to the associated production reactions (K{sup -},{pi}{sup -}), ({pi}{sup +},K{sup +}) since, due to a larger momentum transfer to a hyperon, excitations of both spin-non-flip and spin-flip states are possible. The experiment uses high quality and continuous primary electron beam to produce neutron rich hypernuclei on various targets by the electroproduction. The experimental setup consists of splitter magnet, high resolution kaon spectrometer (HKS) and electron spectrometer (Enge) implemented in new configuration, the so called 'Tilt Method'. Production data was taken on multiple targets: CH{sub 2}, {sup 6}Li, {sup 7}Li, {sup 9}Be, {sup 10}B, {sup 12}C and {sup 28}Si. In present study the analysis of CH{sub 2}, ...
Using bremsstrahlung, the resonance fluorescence yield has been measured for the 1.836-MeV 2/sup +//sub 1/ level in /sup 88/Sr. The observed yield corresponds to a level width GAMMA = 2.94 +- 0.15 meV.
Tensor polarization of "6Li(2.18 MeV, 3"+) nucleus at inelastic scattering of #alpha# particles for #THETA#_l_a_b=45 deg angle is measured. The results are described by the calculations in terms of Born approximation of distorted waves with internucleonic interaction realistic potential.
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.
The reactions of alpha particles on natural abundance chromium have been studied between 40 and 110 MeV, in order to produce "5"2Fe for medical use. The yield of the reaction "5"2Cr(#alpha#,4n)"5"2Fe for Esub(#alpha#) = 85 #-># 53 MeV is only 30 #mu#Ci/#mu#Ah. (orig.).
The diffusion of Sb and B markers has been studied in vacancy supersaturations produced by MeV Si implantation in float zone (FZ) silicon and bonded etch-back silicon-on-insulator (BESOI) substrates. MeV Si implantation produces a vacancy supersaturated near-surface region and an interstitial-rich region at the projected ion range. Transient enhanced diffusion (TED) of Sb in the near surface layer was observed as a result of a 2 MeV Si{sup +}, 1 {times} 10{sup 16}/cm{sup 2}, implant. A 4{times} larger TED of Sb was observed in BESOI than in FZ silicon, demonstrating that the vacancy supersaturation persists longer in BESOI than in FZ. B markers in samples with MeV Si implant showed a factor of 10{times} smaller diffusion relative to markers without the MeV Si{sup +} implant. This data demonstrates that a 2 MeV Si{sup +} implant injects vacancies into the near ...
This paper describes activation measurements of the neutrons from fusion plasmas. We are primarily interested in two narrow bands of neutron energies around 2.5 and 14 MeV. The d-d reaction has two branches with nearly equal probability, one generating a 0.8 MeV {sup 3}He nucleus and a 2.45 MeV neutron, the other a 1 MeV triton and a 3 MeV proton. The d-t fusion generates a 3.5 MeV alpha particle and a 14 MeV neutron. The triton burnup can be defined as the ratio of triton removal rate to triton generation rate. The burnup depends on how well the tritons are confined in the plasma during their slowing down to energies that make d-t fusion probable. It is important to study the tritons as they have similar kinematics to the 3.5 MeV alpha particles in a d-t plasma. Threshold reactions make a distinction between 2.5 and 14 ...
We have measured the K-shell ionization probability Psub(K) across the isobaric analog resonances in the elastic channel of the reactions /sup 88/Sr(p, p/sub 0/)/sup 88/Sr at 5.06 MeV and /sup 86/Sr(p, p/sub 0/)/sup 86/Sr at 6.02 MeV. The dependence of Psub(K) on the beam energy for two scattering angles 90/sup 0/ and 155/sup 0/ is analysed in the framework of the theory developed by Anholt et al. taking into account the effect of compound-nucleus scattering. A compound elastic cross section (dsigma/d..cap omega..)sub(CE)=40+-10 mb/se at the peak of the resonance is deduced in the reaction /sup 88/Sr+p at 5.06 MeV, while the experimental results agree with a negligible value of (dsigma/d..cap omega..)sub(CE) for the resonance in /sup 86/Sr+p at 6.02 MeV.
We have measured the K-shell ionization probability Psub(K) across the isobaric analog resonances in the elastic channel of the reactions "8"8Sr(p, p_0)"8"8Sr at 5.06 MeV and "8"6Sr(p, p_0)"8"6Sr at 6.02 MeV. The dependence of Psub(K) on the beam energy for two scattering angles 90"0 and 155"0 is analysed in the framework of the theory developed by Anholt et al. taking into account the effect of compound-nucleus scattering. A compound elastic cross section (dsigma/d#OMEGA#)sub(CE)=40+-10 mb/se at the peak of the resonance is deduced in the reaction "8"8Sr+p at 5.06 MeV, while the experimental results agree with a negligible value of (dsigma/d#OMEGA#)sub(CE) for the resonance in "8"6Sr+p at 6.02 MeV. (orig.).
Austenitic 316LN alloy was ion-irradiated using the unique Triple Ion Beam Facility (TIF) at ORNL to investigate radiation damage effects relevant to spallation neutron sources. The TIF was used to simulate significant features of GeV proton irradiation effects in spallation neutron source target materials by producing displacement damage while simultaneously injecting helium and hydrogen at appropriately high gas/dpa ratios. Irradiations were carried out at 80, 200, and 350 C using 3.5 MeV Fe{sup ++}, 360 keV He{sup +}, and 180 keV H{sup +} to accumulate 50 dpa by Fe, 10,000 appm of He, and 50,000 appm of H. Irradiations were also carried out at 200 C in single and dual ion beam modes. The specific ion energies were chosen to maximize the damage and the gas accumulation at a depth of {approximately} 1 {micro}m. Variations in microstructure and hardness of irradiated specimens were studied using transmission electron microscopy (TEM) and a ...
The existing theoretical and experimental basis for predicting the levels of resonant static error field at different components m,n that stop plasma rotation and produce a locked mode is reviewed. For ITER ohmic discharges, the slow rotation of the very large plasma is predicted to incur a locked mode (and subsequent disastrous large magnetic islands) at a simultaneous weighted error field ({Sigma}{sub 1}{sup 3}w{sub m1}B{sup 2}{sub rm1}){sup {1/2}}/B{sub T} {ge} 1.9 x 10{sup -5}. Here the weights w{sub m1} are empirically determined from measurements on DIII-D to be w{sub 11} = 0. 2, w{sub 21} = 1.0, and w{sub 31} = 0. 8 and point out the relative importance of different error field components. This could be greatly obviated by application of counter injected neutral beams (which adds fluid flow to the natural ohmic electron drift). The addition of 5 MW of 1 MeV beams at 45{degrees} injection would increase the error field limit by a factor ...
11-MeV neutrons were elastically and inelastically scattered from eight single-closed-shell nuclei: three proton-vibrational nuclei with N = 50 ("8"8Sr, "9"0Zr, "9"2Mo) and five even-even neutron-vibrational nuclei ("1"1"6"-"1"2"4Sn) with Z = 50. Detection methods involving electronic discrimination against #gamma# rays, and time-of-flight techniques were used to measure the energy of the scattered neutrons. Data were taken from 15"0 to 150"0 in 5"0 intervals. Measured differential cross sections were normalized to the zero-degree neutron flux and corrected. An optical model (OM) analysis was used to fit the elastic data with the code GENOA, and potential parameters were obtained for each nucleus. The observed low-lying electric quadrupole (2"+) and octupole (3"-) states were collective in nature; the macroscopic or collective model for inelastic scattering was used to generate the differential cross-section angular distributions with the ...
Post-irradiation annealing was used to help identify the role of radiation-induced segregation (RIS) in irradiation-assisted stress corrosion cracking (IASCC) by preferentially removing dislocation loop damage from proton-irradiated austenitic stainless steels while leaving the RIS of major and minor alloying elements largely unchanged. The goal of this study is to better understand the underlying mechanisms of IASCC. Simulations of post-irradiation annealing of RIS and dislocation loop microstructure predicted that dislocation loops would be removed preferentially over RIS due to both thermodynamic and kinetic considerations. To verify the simulation predictions, a series of post-irradiation annealing experiments were performed. Both a high purity 304L (HP-304L) and a commercial purity 304 (CP-304) stainless steel alloy were irradiated with 3.2 MeV protons at 360 deg. C to doses of 1.0 and 2.5 dpa. Following irradiation, post-irradiation anneals were performed at ...
A detailed investigation of the damage formation and evolution in ion-implanted crystalline Si is presented. Deep-level transient spectroscopy has been used to monitor room temperature migration of point defect complexes and evolution from simple point-like defect complexes to defect clusters and even extended defects. Si samples were implanted with Si or He ions with energies of 145 keV-3MeV, to fluences in the range 5x10[sup 8]-5x10[sup 13]cm[sup -2]. The effects of thermal annealing, in the range 100-680 C and 10 min-15h, were also explored. A systematic comparison of defect complexes formation and evolution in ion-implanted or electron-irradiated Si samples with a different impurity content were used to assess the role of impurities (C and O), extra implanted ion and defect clustering on the nature and thermal stability of residual damage. In particular, an interstitial excess directly resulting from the extra implanted ion is shown to ...
The proton beam has a unique advantage over the electron and photon beams in that it can give very high radiation dose to the tumor volume, while effectively sparing the neighboring healthy tissue and organs. For the clinical application of the proton beam, it is very important to confirm the location of the proton beam in the patient, preferentially during the treatment. It has been suggested that the range of the proton beam in the patient can be determined by measuring prompt gammas from the proton beam passage. Recently, a prototype prompt-gamma scanning system has been constructed and tested using experimental and therapeutic proton beams. The measurement results for the proton beams of 70 . 230 MeV showed that a clear correlation exists between the distribution of the prompt gammas and the proton beam range. The scanning method, however, is not suitable for the upcoming 'spot scanning' technique. The 'spot ...
A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and alpha-particles yield a separate tomographic image of each identified nuclide. The APSTNG also ...
A comprehensive Scanning Tunneling Microscopy (STM) study of submonolayer nucleation and growth of 2D islands in Ag/Ag(100) homoepitaxy for temperature between 295K and 370K is presented. The initial stages of multilayer kinetic roughening is also studied. Analysis of an appropriate model for metal (100) homoepitaxy, produces estimates of 350 meV for the terrace diffusion barrier, 400 meV for the adatom bond energy, and 25 meV for the additional Ehrlich-Schwoebel step-edge barrier.
The "2H(#alpha#,p#alpha#)n reaction was investigated in a kinematically complete experiment with a #alpha#-beam at energy 27.2 MeV.The "5He excited state was observed and its parameters were determinate.Coincidence spectra were fitted by contribution of sequential decay through the "5He ground and excited states.The best agreement with the data was obtained assuming the following "5He excited state parameters: E_a_n=2.8 MeV #GAMMA#=2.5 MeV.
Special beam extraction channel is used at INR linac for isotope production. It starts from 160 MeV measuring and matching area of accelerator. This choice of beam extraction enables to direct to the target of isotope complex a proton beam of wide energy range up to 160 MeV. It is important for production of different types of nuclides. The measuring results of proton beam behavior in this region are presented. Required beam forming in 160 MeV measuring and matching area of accelerator and in beam extraction channel is discussed.
The (p,n) cross section on "8"8Sr was measured for proton energies between 5.75 and 11 MeV. Overall resolution was sufficient to separate the "8"8Y ground state (J/sup #pi#/ = 4"-), the first excited state (J/sup #pi#/ = 5"-) at 0.232 MeV, and the second excited state (J/sup #pi#/ = 1"+) at 0.393 MeV. A Legendre polynomial fit was made to the angular distributions and the resulting integrated cross sections are shown. 1 figure.
Mass distribution in 28.5 MeV alpha particle induced fission of "2"3"2Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of "2"3"5U. (orig.).
Mass distribution in 28.5 MeV alpha particle induced fission of {sup 232}Th has been determined using gamma spectrometric technique. The chain yields of 24 different fission products covering both symmetric and asymmetric mass divisions were determined. The mass distribution was found to be asymmetric with peak positions at mass numbers 96 and 136 respectively while the peak to valley ratio was 3.86. The results are compared with the available literature on 14 MeV neutron induced fission of {sup 235}U. (orig.).
A conical Bragg-curve spectrometer (BCS) has been constructed. The outer case was a molded plastic cone. Printed circuit techniques were used to form an insert with inscribed equipotentials to approximate a 1/r/sup 2/ electric field shape. The charge and energy resolution were measured for elastically scattered beams of 206 MeV /sup 28/Si, 413 and 378 MeV /sup 56/Fe, and 670 MeV /sup 86/Kr ions. Performance of this detector, particularly its charge resolution, is discussed with respect to variation in solid angle.
In a (p,p') study of /sup 88/Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1/sup +/ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1/sup +/ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%.
In a (p,p') study of "8"8Sr at Esub(p) = 201 MeV both a large resonance centered at 9.4 MeV excitation energy and the known 1"+ state at 3.486 MeV are excited. Several discrete states are observed in the resonance. The cross section of the whole resonance is 27% of a simple particle-hole prediction. The strength of the low-lying 1"+ state is only about 15% of that calculated from a wave function including core-polarization contributions, whereas (e,e') scattering finds about 50%. (orig.).
The emission of light charged particles from heavy fragments of uranium fission induced by 153-MeV protons is studied. The probability of their emission is 2.7 x 10{sup - 2} per fission event. It is found that these particles affect the distribution of angles of fragment divergence and the angular distribution of heavy fragments with respect to the primary-proton beam. Experimental results suggest that the preequilibrium emission of particles is correlated with fission. Two mechanisms of interaction between 153-MeV protons and uranium nuclei are considered. 13 refs., 10 figs., 1 tab.
For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10{sup 15} to 1 x 10{sup 16} cm{sup -2}. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.
For the purpose of optimizing the process of co-implantation of MeV Si ions to reduce boron transient enhanced diffusion and boron-enhanced diffusion in Si, multiple MeV implantations and annealing at different temperatures have been performed. A slight improvement on the suppression of B diffusion is observed by adding a low temperature annealing step after the MeV implantation. No differences in B diffusion are observed when the Si doses are increased from 1 x 10"1"5 to 1 x 10"1"6 cm"-"2. This dose independent behavior is speculated to be a quasi-steady state of vacancy cluster evaporation.
We measured differential cross sections and vector analyzing powers for the "4"8Ca(d,n)"4"9Sc reaction at 79 MeV. An overall energy resolution of about 325 keV was achieved, and data were extracted for states up to 3.4 MeV of excitation. Both distorted-wave Born approximation and Johnson-Soper adiabatic approximation calculations were performed; in general, the Johnson-Soper adiabatic approximation calculations provide a better description of the data, and yield reasonable spectroscopic factors.
Neutron-hole states in /sup 87/Sr were studied by means of the /sup 88/Sr("3He,#alpha#)/sup 87/Sr reaction at 36 MeV. Angular distribution measurements were carried out from 3"0 to 41"0 (lab) and analyzed with the zero-range distorted-wave Born approximation method. Spectroscopic factors have been determined for about 50 discrete levels in /sup 87/Sr located below 6 MeV excitation energy and for the three lowest isobaric analog states 2p(3/2, 1f(5/2, and 2p(1/2 observed around 11 MeV. Many l = 1 and l = 3 discrete levels are observed in the 3--6 MeV excitation energy range. In addition, a large part of the 1f-2p strength is found to lie in the higher-lying continuum up to 13 MeV (about 10% and 40% for the l = 1 and 3 contributions, respectively). The distribution of the 1f-2p neutron-hole strength is compared to previous data on neighboring nuclei /sup 89/Zr and /sup 91/Mo. In ...
A nuclear resonance fluorescence experiment on "8"8Sr has been performed with bremsstrahlung of 6.7 MeV endpoint energy. The #gamma#-ray linear polarisation has been measured with a EUROBALL CLUSTER detector used as a Compton polarimeter. The results indicate positive parity for the J=1 state at 4.742 MeV in "8"8Sr, in contrast to the previous interpretation as a 1"- two-phonon (2"+_1 x 3"-_1) state and in conflict with the predictions of the quasiparticle-phonon model. On the basis of such calculations the 1"+ state at 3.486 MeV may be considered as the 1"+_1 one-phonon state and the very strong 1"+_1#->#0"+_1 deexcitation as proton spin-flip 2p_1_/_2#->#2p_3_/_2 transition. (orig.)
The excitation functions of the reactions "9"8Mo(d,p)"9"9Mo and "1"0"0Mo(d,p)"1"0"1Mo have been determined by irradiation of stacked foils with deuterons of energies less than 13 MeV and non-destructive determination of the absolute activity of the Mo radioisotopes by semiconductor #gamma#-ray spectrometry. From the excitation functions, the thick-target yields and the saturation production rates of "9"9Mo and "1"0"1Mo for deuteron energies of 13.0 MeV and 11.7 MeV have been calculated. Implications for the production of "9"9Mo for generators of sup(99m)Tc are discussed. (author).
Elastic scattering of 22 MeV alpha particles by "2"3Na, sup(24-25-26)Mg, "2"7Al and "2"8Si has been measured between 24"0 and 174"0 lab. Partial angular distributions, from 120"0 to 174"0, were also measured at incident energies of 18.4 and 20.7 MeV for "2"4Mg, and 18.9 and 20.5 MeV for "2"8Si. The most striking feature of the data is the large angle behaviour: spin-zero nuclei display more pronounced backward oscillations and the cross section rises more steeply towards 180"0 for 4n nuclei than for the others. (Z.M.).
The real parts of the optical model potentials for 104 MeV alpha-particle and 156 MeV "6Li ion scattering from "4"0,"4"8Ca are calculated in terms of folding model approaches. The validity of different procedures is tested by comparing the differential cross section predictions with experimental data measured with high angular accuracy. It is found that a refined folding potential accounting for density dependence of an effective nucleon-nucleon interaction is appropriate for alpha particle scattering without any parameter adjustment. However, for "6Li ion scattering renormalization of the depth of the real potentials is necessary. (orig.).
This SBIR Phase I developed neutron detectors made from gallium arsenide (GaAs) p-type/ intrinsic/n-type (P-I-N) diodes grown by metalorganic chemical vapor deposition (MOCVD) onto semi-insulating (S1) bulk GaAs wafers. A layer of isotonically enriched boron-10 evaporated onto the front surface serves to convert incoming neutrons into lithium ions and a 1.47 MeV alpha particle which creates electron-hole pairs that are detected by the GaAs diode. Various thicknesses of ''intrinsic'' (I) undoped GaAs were tested, as was use of a back-surface field (BSF) formed from a layer of Al{sub x}Ga{sub 1-x}As. Schottky-barrier diodes formed from the same structures without the p+ GaAs top layer were tested as a comparison. After mesa etching and application of contacts, devices were tested in visible light before application of the boron coating. Internal quantum efficiency (IQE) of the best diode near the GaAs bandedge ...
The method of treatment of uteral cancer by the brake irradiation of 25 MeV betatrone using original devices which promote forming therapeutic figured bunches is presented. The binding of the protective blocks with a special adjusting frame within the aperture of the diaphragm provided for low relative entering dose which is the advantage of high energy irradiation bunch. The use of the forming devices makes it possible to practice individual treatment and decrease the levels of irradiation doses for intact organs and tissues.
The elastic scattering angular distributions of 25 MeV alpha particles scattered from "7"3Ge, "8"9Y, "9"0Zr, "9"1Zr"9"4Zr, "9"3Nb, "4"4Ca and "4"5Sc have been measured experimentally, and fitted using a conventional optical model. (author).
The paper reports the recovery of zinc and cadmium following 6.1 MeV alpha particle irradiation at 4.2 K as studied by means of electrical reistivity measurements. Specimens of 10 #mu#m thick have been used in order to obtain a homogeneous defect distribution over the whole thickness of the specimen. The pre-irradiation resistivity ratios were 700 and 750 for cadmium and zinc, respectively. (Auth.).
Correlations of the Woods-Saxon four-parameter optical potential of scattering of 38 MeV #alpha# particles on sup(68)Zn have been analyzed. A search for discrete sets of potential parameters and functional ratios between different parameters is carried out.
The energy distribution of neutrons generated due to bombardment of 40 MeV alpha particles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons or deuterons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Deuteron irradiation of TiD{sub 2} produced these observations: copious {approx}2.5 MeV neutrons and {approx}3 MeV protons from direct D-D reactions; gamma rays from p,{gamma} and n,{gamma} reactions; {approx}14 MeV protons from the secondary d({sup 3}He, p){alpha} reaction; and a signal between {approx}6-12 MeV that Kasagi et al. has tentatively identified as protons from the fusion of three deuterium nuclei. However, this signal has in it a strong interference signal from either neutrons or gamma rays that directly deposit energy in the detector. This interference spectra was measured by placing a thick absorber in front of the detector that stops up to 20 MeV protons, but not gamma rays or ...
The effect of nuclear scattering on the suprathermal fusion probability of recoiling d-t nuclei under the impact of fusion products, a 14.1-MeV neutron and a 3.5 MeV alpha particle, in thick pellets is investigated with the help of the Boltzmann-Fokker-Planck equation. Although the suprathermal fusion from alpha-particle recoils is quite small, the one originating from neutron recoils is considerable.
The distribution of mass, charge and angular momentum transfer among the products of 54-Fe (255 MeV) ions collisions with the 106 Cd target have been studied. The energy level schemes for 92-Mo, 60-Ni, 96-Ru and 56-Fe are presented. The production yields of different isotopes were also measured. 1 ref., 14 figs.
The objective of the study is to measure the neutron cross sections for the "5"9 Co (n, 2n) "5"8 Co reaction around the 14 MeV energy region. Neutron activation cross section for almost all the nuclei, mostly in the medium energy region e.g., 7 to 20 MeV are reported in literature. Neutron cross section data around 14 MeV is of immense importance for the design of D + T fusion reactors. The accuracy of the cross section data at this energy region is a requirement for correct prediction of reactor parameters e.g., tritium breeding, nuclear heating, induced activity, etc. In order to perform the experiment, the Co-sample sandwiched in Ni foils was irradiated employing the J-25 Neutron Generator at the AERE, Savar, Dhaka. After irradiation, the counting was done by the activation technique using a high resolution Hp Ge gamma ray spectrometer. The gamma ray spectra was analyzed in a Canberra series-40 Multi-channel Analyzer. ...
We measured neutron time-of-flight spectra from 90 MeV protons and 140 MeV alpha particles bombarding thin targets of Al, Ni, Zr, and Bi at laboratory angles between 20_0 and 135_0. The low-energy (5 to 45 MeV) portions of the spectra were measured with 5 cm diameter by 5 cm deep NE-213 counters at 1 m flight paths with n-#betta# pulse-shape discrimination. The high-energy (35 to 150 MeV) portions of the spectra were measured with 12.7 cm diameter by 10.2 cm deep NE-102 counters at flight paths of 2.0 to 5.0 m. The proton-induced measured neutron spectra reveal three distinct energy regions: a low-energy evaporation region, a high-energy region dominated by the quasifree scattering process, and an intermediate-energy region dominated by multistep, preequilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-particle induced neutron spectra show these same ...
A theoretical model is proposed for analyzing elastic scattering of 100-150 MeV #alpha#-particles on intermediate mass nuclei. It is shown that, within the scope of this model accounting for inhomogeneous target-nucleus density, an anomalous growth of differential cross section of elastic scattering in the region of average angles can be explained.
The operation principle, construction and characteristics of the Bragg curve spectroscopy detector (BCS detector) are described. The electric field of the BCS detector is parallel to the particle trajectories. The detector was tested by 8.78 MeV and 6.02 MeV #alpha# particles from a ThC-ThC's source. The energy resolutions are 1.5% and 2.6% respectively for two groups of #alpha# particles, and the charge resolution is 2.7%. Further test experiments with heavy ions will be arranged.
Cell death after irradiation occurs by apoptosis in certain cell populations in tissues. The phenomenon also occurs after high linear energy transfer (LET) irradiation, and the relative biological effectiveness (RBE) is 3 to 4 (with respect to low-LET radiation and apoptosis in intestinal crypts) for neutrons with energies of 14 MeV and up to 600 MeV. It is thought that p53 plays a role in the phenomenon, as radiation-induced apoptosis is not observed in p53-null animals. (orig.).
Toroidicity Alfven Eigenmodes (TAE) in ITER can be driven unstable by two groups of energetic particles, the 3.5 MeV {alpha}-particle fusion products and the tangentially injected 1MeV beam ions. Stability conditions are established using the perturbative NOVA/NOVA-K codes. A quasi-linear diffusion model is then used to assess the induced redistribution of energetic particles.
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si{sup +} ion implants at very high doses ({approx}10{sup 16}cm{sup {minus}2}). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation ({approx}700 at 740{degree}C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of {l_brace}311{r_brace} defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an ...
We measure the transient enhanced diffusion of shallow molecular-beam-epitaxy grown marker layers of Sb and B due to deep MeV Si"+ ion implants at very high doses (#approx#10"1"6cm"-"2). We expect the near-surface region of these implants to be vacancy rich, and we observe transient enhanced diffusion of Sb (the classic vacancy diffuser). The large enhancements imply a significant vacancy supersaturation (#approx#700 at 740 degree C). Double implantation of the high-dose MeV Si followed by a shallow (40 keV) Si implant and annealing produces a greatly reduced number of #left brace#311#right brace# defects compared to a 40 keV implant into virgin Si, again consistent with a vacancy-rich region in the near-surface region of an MeV implant. However, the shallow B marker layers also show transient enhanced diffusion for the same MeV implant under similar annealing conditions, implying that an interstitial ...
The experiments show that the fluence threshold of 316L SS irradiated by 1.8 MeV alpha particle is between (0.8655-1.3457) x 10"1"8 #alpha#/cm"2, and the threshold decreases in the 1.5 MeV and 1.0 MeV alpha particle irradiation. For the solid solution samples irradiated by 1.5 MeV alpha particle, the threshold is below 0.5595 x 10"1"8#alpha#/cm"2, and for the 20% cold-worked sample, the threshold is between (0.8595-0.5063) x 10"1"8 #alpha#/cm"2. In 1.0 MeV alpha particle irradiation, the threshold for the solid solution sample and 20% cold-worked sample is between (0.3073-0.1024) x 10"1"8 #alpha#/cm"2 and (0.4108-0.3063) x 10"1"8 #alpha#/cm"2 respectively. The difference of threshold of the two kinds of samples shows that the 20% cold-working can influence the occurrence of blistering
The experiment on the determination of the tensor polarization of the residual nucleus is described for the reaction "6Li (#alpha#, #alpha#') "6Li. It is based on the unique connection of polarization tensors t_l_m of the residual nucleus for the reaction (#alpha#, #alpha#') and the angular correlation function W (#omega#_1, #omega#_2) for #alpha#'-particle and decay product of this nucleus, where #omega#_1, #omega#_2 are motion directions of #alpha#'-particle and decay product. The angular correlations of #alpha#'-particle and deuteron are measured for the "6Li (#alpha#, #alpha#', d)"4He reaction on the 27.2 MeV #alpha#-particle beam. The recording system consists of six silicon detectors and provides the energy resolution about 0.8 MeV and the angular resolution #+-# 3 deg. The polarization tensors of the residual nucleus "6Li (2.185 MeV, 3"+) are determined as the result of measuring the angular correlations of products ...
Evaluation of nuclear data has been performed for {sup 237}Np, {sup 241}Am, {sup 242g}Am and {sup 242m}Am. Neutron data were obtained at energies from 20 to 250 MeV and combined with JENDL-3.3 data at 20 MeV. Evaluation of the proton data has been done from 1 to 250 MeV. The coupled channel optical model was used to obtain angular distributions for elastic and inelastic scattering and transmission coefficients. Pre-equilibrium exciton model and Hauser-Feshbach statistical model were used to describe neutron and charged particles emission from excited nuclei. These evaluation is the first work for producing full sets of evaluated file up to 250 MeV for {sup 237}Np and Americium isotopes. (author)
Evaluation of nuclear data has been performed for sup 2 sup 3 sup 7 Np, sup 2 sup 4 sup 1 Am, sup 2 sup 4 sup 2 sup g Am and sup 2 sup 4 sup 2 sup m Am. Neutron data were obtained at energies from 20 to 250 MeV and combined with JENDL-3.3 data at 20 MeV. Evaluation of the proton data has been done from 1 to 250 MeV. The coupled channel optical model was used to obtain angular distributions for elastic and inelastic scattering and transmission coefficients. Pre-equilibrium exciton model and Hauser-Feshbach statistical model were used to describe neutron and charged particles emission from excited nuclei. These evaluation is the first work for producing full sets of evaluated file up to 250 MeV for sup 2 sup 3 sup 7 Np and Americium isotopes.
Differential elastic and inelastic neutron-scattering cross sections of elemental iron are measured from 4.5 to 10 MeV in increments of {approx}0.5 MeV. The measurements are made at >or{approx}40 scattering angles distributed between {approx}17 and 160 , with emphasis on elastic scattering and inelastic scattering due to the excitation of the yrast 2{sup +} state. The measured data is combined with earlier lower-energy results from this laboratory, with recent high-precision {approx}9.5-15 MeV results from the Physikalisch. Technische Bundesanstalt and with selected values from the literature to provide a detailed neutron-scattering data base extending from {approx}1.5 to 26 MeV. This data is interpreted in the context of spherical-optical and coupled-channels (vibrational and rotational) models, and the physical implications are discussed. Deformation, coupling, asymmetry and dispersive effects are ...
The MOS-technology allows to make tiny electronic lenses for multibeam electron systems. In the paper results of research and principles of designing of tiny magnetic electron lenses are submitted. Electronic lenses with a nonconventional configuration of tiny magnetic circuit and electronic lenses with coincident electric and magnetic fields in nonconventional tiny performance are considered
A study of the electron beam dynamics in the linac is conducted for the FERMI free electron laser (FEL) founded for construction at the Sincrotrone Trieste.
A study of the electron beam dynamics in the linac is conducted for the FERMI free electron laser (FEL) founded for construction at the Sincrotrone Trieste
We show that, for the high electron currents used in present-day free-electron lasers, spontaneous radiation is distributed according to thermal statistics.
... iFfficiency-en- enhanced spontaneous radiation at the free-electron- ... as enhanced spontaneous radiation at the free-electron-laser wavelength. ...
The proton beam has an advantage of the sharp dose falloff in dose distribution called Bragg peak while conventional radiation therapy modalities such as photons exhibit considerable amount of exit dose. To take advantage of this property it is important to know the exact location of the distal dose falloff. An error can cause overdose to the normal tissue or underdose to the tumor volume. The only way of finding out the dose distribution in-situ in particle therapy is to measure the gammas produced by nuclear reactions with tissue materials. Two kinds of gammas can be used: one is prompt gamma and the other is coincident gamma from the positron-emission isotopes. We chose to detect prompt gammas, and developed a prompt gamma scanning system (PGS). The proton beams of the proton therapy facility at National Cancer Center were used. The gamma distribution was compared to the dose distribution measured by an ionization chamber at three different energies of 100, 150, 200 MeV's. ...
Full text of publication follows: Radiation hardening and embrittlement due to high-energy neutron radiation around 623 K are the important issues on reduced-activation ferritic/martensitic (RAF/M) steels. It is expected that the improvement of radiation hardening might be one of effective ways to control the mechanical properties of RAF/M after irradiation. It has been reported that the weld joint has less hardening than the base metal from the tensile test results of TIG weldments irradiated in HFIR. This report indicated that radiation hardening can be reduced by the optimization of heat treatment condition for F82H. The purposes of this study are to establish the condition of heat treatment for minimum of radiation hardening in F82H steel using Neutron/Ion-irradiation and to examine a correlation between tensile property and micro-hardness before/after irradiation. The materials used in this study were F82H IEA heat and F82H heat treatment variants. Neutron irradiation was ...
Three resonances at the proton energies 7.0, 7.08, and 7.53 MeV on the target "8"8Sr were chosen to investigate the possibility of determining the amplitudes of the weak coupling experimentally. The corresponding "8"9Sr levels under investigation were 1.93 MeV ("5/_2"+), 2.00 MeV ("3/_2"+), and 2.46 MeV ("3/_2"+). Angular distributions were measured on resonance at 7.0, 7.08, and 7.53 MeV from proton inelastic scattering to the 1.84 MeV (2"+) state of "8"8Sr for differential cross section, analyzing power, spin-flip probability, and spin-flip asymmetry. A polarized beam of protons was used to obtain the analyzing power. The spin-flip probability was obtained from the coincidence of the prompt gamma rays from the (p,p'#gamma#) reaction with the scattered protons. With the polarized beam, the gamma coincidence technique was further used to obtain a spin-flip ...
In the framework of the $^3P_0$ meson decay model, the strong decays of the $3 ^1S_0$ and $4 ^1S_0$ $s\\bar{s}$ states are investigated. It is found that in the presence of the initial state mass being 2.24 GeV, the total widths of the $3 ^1S_0$ and $4 ^1S_0$ $s\\bar{s}$ states are about 438 MeV and 125 MeV, respectively. Also, when the initial state mass varies from 2220 to 2400 MeV, the total width of the $4 ^1S_0$ $s\\bar{s}$ state changes from about 100 MeV to 132 MeV, while the total width of the $3 ^1S_0$ $s\\bar{s}$ changes from about 400 MeV to 594 MeV. A comparison of the predicted widths and the experimental result of $(0.19\\pm 0.03^{+0.04}_{-0.06})$ GeV, the width of the $\\eta(2225)$ with a mass of $(2.24^{+0.03+0.03}_{-0.02-0.02})$ GeV recently observed by BES Collaboration in the radiative decay ...
The purpose was to identify human in vitro cell lines with a high relative cellular sensitivity to fast neutrons as compared to photons and to examine their relationship to intrinsic photon radiosensitivity and cellular proliferation kinetics. The clonogenic cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell kinetic parameters of 30 human in vitro cell lines, covering a wide range of histologies, were analyzed alone and with previously published data of Fertil and Malaise. The relative survival at 1.6 Gy of neutrons (SF_1_._6) compared to 2 Gy of photons (SF_2) and the cell kinetic parameters of the 30 cell lines were also compared. The relative lethality of 62.5 MeV fast neutrons was ...
Purpose: Patients with mycosis fungoides [cutaneous T-cell lymphoma (CTCL)] may benefit from adjuvant therapy after completing total skin electron beam therapy (TSEBT). We report the results for (T1(T2)) CTCL patients treated with adjuvant oral psoralen plus ultraviolet light (PUVA) with respect to overall survival (OS), disease-free survival (DFS), salvage of recurrence, and toxicity. Methods and Materials: Between 1974 and 1993, TSEBT was administered to a total of 213 patients with CTCL. Records were reviewed retrospectively, and a total of 114 patients were identified as having T1 or T2 disease. Radiotherapy was provided via a 6-MeV linac to a total of 36 Gy, 1 Gy/day, 4 days/week, for 9 weeks. Beginning in 1988, patients were offered adjuvant PUVA within 2 months of completing TSEBT. This was started at 0.5-2 J/m"2, 1-2 treatments/week, with a taper over 3-6 months. Therapy then continued once per month. There were 39 T1 and 75 T2 ...
A Bragg curve detector (BCD) has been designed and built to be used for AMS purposes. Its design is described and its performance, obtained in tests at the Australian National University (ANU), is reported. At a {sup 36}Cl energy of 154 MeV, the energy resolution was found to be 0.38%, and the charge resolution 1.3%. The {sup 36}Cl and {sup 36}S are completely discriminated. Good separation was also achieved at 64 MeV, and a measurement at this energy of the {sup 36}Cl/Cl ratio of a sample measured previously at 154 MeV with the standard ANU ionization detector agreed well with the earlier value. This very simple detector has been shown to be suitable for use in AMS programs.
All stable even-A molybdenum isotopes and sup(90,92)Zr have been investigated with the (d, "6Li) reaction at Esub(d) = 45 MeV to study proton- and neutron-pair correlations. Differential cross sections were measured for states up to Esub(x) = 3 MeV in "8"6Sr, sup(88,92,94,96)Zr and up to 6 MeV in "8"8Sr and "9"0Zr. Particular attention was paid to the comparison of #alpha#-pickup data with two-nucleon pickup data. The population of low-lying 0"+ and 5"- states for two-neutron and four-nucleon pickup reactions was calculated using simple phenomenological wave functions for the initial and final states. The results of these calculations are in satisfactory agreement with the data. (orig.).
TiH{sub 2} and TiD{sub 2} thick targets were bombarded with 100 to 200 keV protons. Evidence for nuclear reactions was obtained by means of a surface barrier particle detector. Proton irradiation of TiD{sub 2} produced the following observations: {alpha} particle emission identified as (p, {alpha}) reactions from {sup 11}B and {sup 7}Li impurities in the target at ppm concentrations; and {approx}3 MeV proton and {approx}1 MeV triton emission from secondary D-D reactions caused by elastic scattering of the primary proton with a target deuteron. A 3.9 MeV {alpha} particle peak measured by others was not observed. (author)
The dd{yields}{sup 4}He{eta} reaction has been investigated near threshold using the ANKE facility at COSY-Juelich. Both total and differential cross-sections have been measured at two excess energies, Q=2.6 MeV and 7.7 MeV, with a subthreshold measurement being undertaken at Q=-2.6 MeV to study the physical background. While consistent with isotropy at the lower energy, the angular distribution reveals a pronounced anisotropy at the higher one, indicating the presence of higher partial waves. Options for the decomposition into partial amplitudes and their consequences for the determination of the s-wave {eta}{alpha} scattering length are discussed. (orig.)
An experiment on the K#beta#/K#alpha# characteristic X-ray intensity ratio in silver was performed at VEC Centre, Calcutta using the #alpha#-beams at energies 40 MeV and 50 MeV employing a Si(Li) detector system on-line. The results show that the K#beta#/K#alpha# X-ray intensity ratio at energies 40 and 50 MeV are 0.215 #+-# 0.006 and 0.216 #+-# 0.006, respectively, which indicates no change with beam energy and in accordance with the earlier reports. The present experiment shows the feasibility of studying the K#beta#/K#alpha# ratios as a function of beam energy in different regions of periodic table. Experiments in elements belonging to the 3d shell and their compounds are suggested to look for the chemical effects and their dependence on #alpha#-energy. (author). 7 refs.
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
The high selectivity of 201 MeV inelastic proton scattering at forward angles for exciting ..delta..L=0 spin flip transitions is outlined by comparison with (e,e') and 65 MeV (p,p') measurements. A summary of the results obtained on the calcium isotopes, the N=28 isotones, /sup 88/Sr and /sup 90/Zr is presented. The differences in the relative M1 strength distributions between the (p,p') and the (e,e') results are discussed. Preliminary results on /sup 208/Pb are given; the ''isoscalar'' 1/sup +/ state at 5.846 MeV is excited.
The production of the {lambda}- and {sigma}{sup 0}-hyperons has been measured via the pp{yields}pK{sup +}{lambda}/{sigma}{sup 0} reaction at the internal COSY-11 facility in the excess energy range between 14 and 60 MeV. The transition of the {lambda}/{sigma}{sup 0} cross-section ratio from about 28 at Q{<=}13 MeV to the high-energy level of about 2.5 is covered by the data showing a strong decrease of the ratio between 10 and 20 MeV excess energy. Effects from the final-state interactions in the p-{sigma}{sup 0} channel seem to be much smaller than in the p-{lambda} channel. Estimates of the effective range parameters are given for the N{lambda} and the N{sigma} systems. (orig.)
This paper describes a concept for a current drive system based on negative ions with beam energy > 1 MeV. Preliminary physics calculations show that the core current necessary for stability enhancement can best be achieved by beams with energy ranging from 1 to 4 MeV. Further study and experiments will better define the optimum energy. Work under way at Oak Ridge National Laboratory (ORNL) and at collaborating institutes in Canada and the Federal Republic of Germany is defining a system, its elements, a configuration and operational scenarios deemed appropriate for such devices as ITER and other future steady-state tokamaks, and the requisite research and development to provide such a system. 7 refs., 2 figs.
The study of the {alpha}-particle energy distributions associated with ND and SD states in {sup 151,152}Dy has been carried out. The Dy isotopes were produced in the reaction {sup 37}Cl+{sup 123}Sb at 191 MeV via the ({alpha}5n) and ({alpha}4n) channels, respectively. In {sup 151}Dy the {alpha}-particle energy distributions associated to ND and SD are very different from each other, both at the low and high energy sides inducing a difference of 3 MeV in the {alpha}-particle mean energy. In {sup 152}Dy the situation is different; the {alpha}-particle spectral shapes are similar and a difference in the {alpha}-particle mean energy of only 0.7 MeV is deduced. A description in terms of energy localization of entry states is given. (orig.)
We analyze the nucleon axial-vector coupling to two loops in chiral perturbation theory. We show that chiral extrapolations based on this representation require lattice data with pion masses below 300 MeV.
A statistical treatment has been applied to interpret the experimental data on the Xe M-shell vacancy production in slow 1.05 MeV Xe-Xe collisions and is shown to give better agreement with experiment than that of the molecular-orbital models.
Reverse genetics technology so far established for measles virus (MeV) is based on the Edmonston strain, which was isolated several decades ago, has been passaged in nonlymphoid cell lines, and is no...Full Text Available
The giant resonance region in several nuclei in A {>=} 90 have been re-measured using 240 MeV {alpha} particle scattering with a detector provides that both horizontal and vertical angles. Slice analyses with multipole fits were performed and strength due to both low and high energy components of the isoscalar giant dipole resonance (ISGDR) was identified. E1 strengths for the high energy component corresponding to 70{+-}15%,68{+-}15% and 67{+-}14% of the isoscalar E1 energy-weighted sum rule were identified, with centroid energies of 26.3{+-}0.6 MeV, 24.7{+-}0.6 MeV and 21.7{+-}0.6 MeV for {sup 90}Zr, {sup 144}Sm and {sup 208}Pb, respectively. The centroid of the high energy component of the strength distribution is in closer agreement with the microscopic prediction generated using compressibilities obtained from the isoscalar giant monopole resonance data.
A nuclear resonance fluorescence experiment on {sup 88}Sr has been performed with bremsstrahlung of 6.7 MeV endpoint energy. The {gamma}-ray linear polarisation has been measured with a EUROBALL CLUSTER detector used as a Compton polarimeter. The results indicate positive parity for the J=1 state at 4.742 MeV in {sup 88}Sr, in contrast to the previous interpretation as a 1{sup -} two-phonon (2{sup +}{sub 1} x 3{sup -}{sub 1}) state and in conflict with the predictions of the quasiparticle-phonon model. On the basis of such calculations the 1{sup +} state at 3.486 MeV may be considered as the 1{sup +}{sub 1} one-phonon state and the very strong 1{sup +}{sub 1}{yields}0{sup +}{sub 1} deexcitation as proton spin-flip 2p{sub 1/2}{yields}2p{sub 3/2} transition. (orig.)
To calibrate channels A1 to A4 for particles with Z >= 1, tests were done on the IBIS accelerator at AERE, Harwell, which gave protons up to 3 MeV. ...
A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation length brought large error into the dose estimation behind thick ...
Careful measurements do not confirm an anomalous anisotropy in the angular distribution of fission fragments from the fast neutron fission of Americium 242. The energy range covered was 1.60-3.15 MeV. (AIP)
of the supplier of pulled p-type silicon material. of G-6 and E 8 centers irradiated in the 1 t o 3 MeV range. tions w i l l be performed using the General ...
A study was made into microstructure and hardening in austenitic stainless steel 0Kh18N10T irradiated with neon ions (230 MeV) and neutrons (E_n > 0.1 MeV). The experiments were accomplished using an external beam of U-400 cyclotron (Dubna) and EWA reactor (Poland). The dependences of tensile properties, hardening index, microstructure, dislocation density on damaging dose were determined. An attempt is made to reveal the correlation between an yield strength increment and defect cluster accumulation. The interpretation of variations of mechanical properties and microstructure under irradiation is given.
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements (PGE) and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a tandem Van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
The general usefulness of neutron activation analysis (NAA) for samples containing the platinum group elements and Au, either as major or trace constituents, is discussed. Charged particle activation is shown to be a viable or complementary alternative. Proton (6-10 MeV) and alpha particle (9-15 MeV) beams, produced in a Tandem van de Graaff accelerator, have been established to be the most effective choice. By taking advantage of the Coulomb barrier effect and the fact that many charged particle induced reactions have relatively large threshold values, the same instrumental technique can be applied, with minor modifications, to a wide range of materials.
The satellite-borne experiment PAMELA has been used to make a new measurement of the cosmic-ray antiproton flux and the antiproton-to-proton flux ratio which extends previously published measurements down to 60 MeV and up to 180 GeV in kinetic energy. During 850 days of data acquisition approximately 1500 antiprotons were observed. The measurements are consistent with purely secondary production of antiprotons in the galaxy. More precise secondary production models are required for a complete interpretation of the results.
Using U-120 cyclotron in the course of correlation experiment one studied mechanisms of excitation and decay of "1"2C nucleus states resulting from irradiation of deuterium-polyethylene target by 27.2 MeV energy #alpha#-particle beam via recording of #alpha#-#alpha#-coincidence simultaneously with investigations of #alpha# + d-interactions. Production of "1"2C excited states decaying with the escape of #alpha#-particle and "8Be nucleus in the ground and the excited states is the basic mechanism of the studied #alpha# + "1"2C interaction
Nuclear reaction cross-sections for stable strontium and cesium isotopes, which were calculated by different approaches, are compared to available experimental data. Neutron and proton induced reaction cross-sections for the long-lived radionuclides [sup 90]Sr and [sup 137]Cs have been calculated in the energy range from 1 MeV to 10 GeV. Recommendations concerning cross-section calculations for strontium and cesium isotopes at intermediate and high energies are given. (orig.)
In the reaction sup(nat)Ag + /sup 40/Ar (285 MeV) there have been measured the energy spectra of the isotopes of elements from H to Cl at an emission angle of 40/sup 0/, the energy spectra and angular distributions of /sup 1/H, /sup 2/H, /sup 3/H, and /sup 4/He, and the angular distributions of Li, Be, B, and C. The contribution from multinucleon transfer reactions to the formation of light charged particles is discussed.
Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.
The L-subshell and total M-shell X-ray production cross sections of Ta, W, Pt, Au, Pb and Bi have been measured by protons of energy between 0.7 and 2.4 MeV. The obtained results for X-ray production cross sections have been compared with the existing experimental data, prediction of the ECPSSR theory and also with fitted empirical cross sections of Strivay and Weber.
Experimental differential cross sections for 104 MeV #alpha#-particle scattering have been analysed using a method recently proposed for model-independent analyses. Reliable values of isoscalar (0"+ -3"1"-) octupole transition rates in _5_0Ti, _5_2Cr and _2_0_8Pb are presented and compared with electromagnetic rates. (author).
Data for the excitation of the 2_1"+ and 2_2"+ states in the "8"8Sr(p,p') reaction at 25 and 31 MeV indicate sustantial contributions from the interior of the nucleus, Microscopic DWBA calculations reproduce this and yield a fair description of the data. A detailed description, especially of the 2_2"+ state, is sensitive to the effective nucleon-nucleon interaction used and the non-locality of the optical potential, which are insufficiently known at present. (orig.).
Data for the excitation of the 2/sub 1//sup +/ and 2/sub 2//sup +/ states in the /sup 88/Sr(p,p') reaction at 25 and 31 MeV indicate sustantial contributions from the interior of the nucleus, Microscopic DWBA calculations reproduce this and yield a fair description of the data. A detailed description, especially of the 2/sub 2//sup +/ state, is sensitive to the effective nucleon-nucleon interaction used and the non-locality of the optical potential, which are insufficiently known at present.
The energy spectra of few-nucleon transfer reactions obtained by bombarding a /sup 197/Au nucleus with the 341 MeV /sup 20/Ne beam of the Berkeley cyclotron have been analysed successfully in terms of direct surface transfer reactions populating the continuum states. At the grazing angle we are dealing with one-step processes; at forward angle two-step processes have to be taken into account.
Angular distributions for the elastic and inelastic scattering of /sup 12/C at 80 MeV by /sup 88/Sr and of /sup 7/Li at 36, 42 and 48 MeV by /sup 54/Fe have been analysed. The optical potentials of /sup 12/C and /sup 7/Li ions are calculated in terms of the alpha-particle and triton optical potentials. Coupled-channels calculations using these potentials are performed. Good fits to the experimental data and the phenomenological calculations are obtained for /sup 12/C projectiles.
The charge distribution in the alpha particle induced fission of "2"0"9Bi has been studied at alpha particle energy of 55.7 MeV and 58.6 MeV. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo and "1"1"2Pd have been determined using gamma ray spectrometry. The charge distribution have been found to be broad. (author). 4 refs., 1 ta b.
High energy ion backscattering analysis in combination with recently-developed resonance scattering analysis is described, with a stress on precise and quantitative oxygen analysis and its successful application to the characterization and quality estimation of high T_c oxide superconductors. Particularly, the present status of high energy ion backscattering analysis, the review of analytical results for YBa_2Cu_3O_7 _- _x, the estimation of composition and crystalline quality of (La_1 _- _xSr_x)_2CuO_4 by 7 MeV alpha particle backscattering analysis are described.
Alpha-particle emission induced by neutron bombardment of carbon has been studied from threshold to over 30 MeV using the spallation neutron source at WNR/LAMPF. Targets include thin foils of CH{sub 2} and thicker foils of CH and polycrystalline graphite. Comparisons are made with evaluated data. Values for KERMA (kinetic energy released in materials) based on the results will be presented and compared with those obtained through other experimental approaches.
The detection efficiency of #alpha# particles of "2"1"4Po 7.69 MeV and "2"1"8Po 6.00 MeV in measuring radon daughters were determined through the data which were measured with long-lived #alpha# standard source and radon daughter standard source and with curve-fitting method of general formulation. The indeterminacy was #<=#2.5% and #<=#2.7% respectively. Their ranges in filter membrane were also determined, and the effect of the indeterminacy on the self-absorption factors was #<=#1.3%.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from /sup 90/,/sup 92/Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates.
Differential cross sections have been measured for the elastic and inelastic scattering of 104 MeV alpha-particles from "9"0,"9"2Zr. The experimental data are analyzed in terms of coupled channels on the basis of a flexible anharmonic vibrator model and using different parametrizations of the radial shape of the extended optical potential. The results favour the squared Saxon-Woods type for the real part. Additionally to a radial momentum analysis of the real potentials a semimicroscopic folding model has been invoked for extracting isoscalar quadrupole and hexadecapole transition rates. (orig.).
Atoms in very high Rydberg states, 100 approx-lt n approx-lt 1100, are used to investigate electron-molecule interactions at electron energies extending down to a few microelectronvolts. At such energies the cross section for electron capture by CCl_4 is observed to vary inversely with electron velocity, indicative of an s-wave process. Studies with the polar target CH_3Cl suggest that dipole-supported states may be important in inelastic electron-polar molecule scattering at very low electron energies.
An e.p.r. spectrum of the reduced form of the electron-transport component (X), thought to be the primary electron acceptor of Photosystem I, was obtained. By using line-shape simulations of this component...Full Text Available
The existence of a narrow peak of electron state density in A-15 is explained by a strong electron-phonon interaction that brings about the polaron narrowing of zone. In the supposition of weak and intermediate bond, the analytical expression for the critical transition temperature is found that corre lates Tsub(c) with phonon spectrum. The model permits to explain Tsub(c) correlation with the number of electrons per atom, temperature direction of resistance, value and temperature dependence of magnetic susceptibility and electron thermal capacity.
The existence of a narrow peak of electron state density in A-15 is explained by a strong electron-phonon interaction that brings about the polaron narrowing of zone. In the supposition of weak and intermediate bond, the analytical expression for the critical transition temperature is found that corre lates Tsub(c) with phonon spectrum. The model permits to explain Tsub(c) correlation with the number of electrons per atom, temperature direction of resistance, value and temperature dependence of magnetic susceptibility and electron tehrmal capacity.
We study two correlated electrons in a nearest-neighbour tight-binding chain, with both on-site and nearest-neighbour interaction. Both the cases of parallel and antiparallel spin are considered. In addition to the free electron band for two electrons, there are correlated bands with positive or negative energy, depending on whether the interaction parameters are repulsive or attractive. Electrons form bound states, with amplitudes that decay exponentially with separation. Conditions for such states to be filled at low temperatures are discussed.
A new magnetic electron microscope, UEMB-100, was designed with an increased electron-optical parameter. The electron-optical system consists of an electron canon (the high voltage is supplied by armored lead) and condensed, objective, intermediate, and projection lenses. In contrast to other native apparatuses, the microscope has a high resolving property (up to 20A) snnd great universality. (tr-auth)
Conversion electron studies of medium-heavy to heavy nuclear mass systems are important where the internal conversion process begins to dominate over gamma-ray emission. The use of a segmented detector array sensitive to conversion electrons has been used to study multiple conversion electron cascades from nuclear transitions. The application of the silicon array for conversion electron detection (SACRED) for in-beam measurements has successfully been implemented. (orig.). With 2 figs.
An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.
An electron accelerator unit is described for electron beam therapy, comprising: a source of an electron beam; means for finally directing at least a portion of the beam to a therapy site, the directing means being mechanically independent of, and electrically isolated from, the source, and having a target area; and means for aligning the source with the directing means, the aligning means comprising means for projecting at least one beam of light from the source toward the target area.
The electron beam ion source (EBIS) at Texas A and M University was constructed and is currently undergoing tests on the injection and transmission of the electron beam through the solenoid. Results of computer simulation of the electron beam are presented, as well as measurements of electron beam profiles using a pinhole beam analyzer.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
The literature of radiation damage measurements on cadmium zinc telluride (CZT), cadmium telluride (CT), and mercuric iodide (HgI{sub 2}) is reviewed and in the case of CZT supplemented by new alpha particle data. CZT strip detectors exposed to intermediate energy (1.3 MeV) proton fluences exhibit increased interstrip leakage after 10{sup 10} p/cm{sup 2} and significant bulk leakage after 10{sup 12} p/cm{sup 2}. CZT exposed to 200 MeV protons shows a two-fold loss in energy resolution after a fluence of 5 {times} 10{sup 9} p/cm{sup 2} in thick (3 mm) planar devices but little effect in 2 mm devices. No energy resolution effects were noted from moderated fission spectrum of neutrons after fluences up to 10{sup 10} n/cm{sup 2}, although activation was evident. Exposures of CZT to 5 MeV alpha particle at fluences up to 1.5 {times} 10{sup 10} {alpha}/cm{sup 2} produced a near linear decrease in peak position with fluence and ...
Photosynthetic (Ps) electron transport pathways often contain multiple electron carriers with overlapping functions. Here we focus on two c-type cytochromes (cyt) in facultative phototrophic...Full Text Available
The main subject of this thesis is the study of the hardronic final state in deep-inelastic electron-proton scattering. Theexperiment described in this thesis is performed with such a high resolution that the substructure of the proton is probed by the electron beam with a resolution of less than 10{sup -15} cm. (orig./HSI).
For over 50 years, electron beams have been an important modality for providing an accurate dose of radiation to superficial cancers and disease and for limiting the dose to underlying normal tissues and structures. This review looks at many of the important contributions of physics and dosimetry to the development and utilization of electron beam therapy, including electron treatment machines, dose specification and calibration, dose measurement, electron transport calculations, treatment and treatment-planning tools, and clinical utilization, including special procedures. Also, future changes in the practice of electron therapy resulting from challenges to its utilization and from potential future technology are discussed. (review)
When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e{yields}{gamma} conversion for future {gamma}{gamma} colliders. (orig.). 16 refs.
When polarized electrons traverse a region where the laser light is focused their polarization varies even if their energy and direction of motion are not changed. This effect is due to interference of the incoming electron wave and an electron wave scattered at zero angle. Equations are obtained which determine the variation of the electron-density matrix, and their solutions are given. The change in the electron polarization depends not only on the Compton cross section but on the real part of the forward Compton amplitude as well. It should be taken into account, for example, in simulations of the e#->##gamma# conversion for future #gamma##gamma# colliders. (orig.).
The Advanced Power Electronics Interfaces for Distributed Energy Workshop, sponsored by the California Energy Commission Public Interest Energy Research program and organized by the National Renewable Energy Laboratory, was held Aug. 24, 2006, in Sacramento, Calif. The workshop provided a forum for industry stakeholders to share their knowledge and experience about technologies, manufacturing approaches, markets, and issues in power electronics for a range of distributed energy resources. It focused on the development of advanced power electronic interfaces for distributed energy applications and included discussions of modular power electronics, component manufacturing, and power electronic applications.
Though notes in electronic medical record systems (EMRs) have advantages, they are often criticized for their unattractive and unprofessional appearance. We sought to identify notes regarded by physicians...Full Text Available
A detailed treatment is introduced to measure the dynamic stability of the relativistic electrons in a self-amplified spontaneous emission free-electron laser (FEL) system, which includes the numerical approach of the Kolmogorov entropy (entropy-like quantity), the general equations of motion for a charged particle and the method of monitoring the simulation accuracy. Numerical experiments reveal a new phenomenon that there exists the possibility of the transition from chaotic to non-chaotic phase-space trajectories of the strongly relativistic electrons due to the effect of their self-fields. The adiabatic magnetic field of a one-dimensional wiggler may have a slight influence on the electron transportation in the absence of the FEL fields, but substantially affects the dynamic stability of the electrons in the process of the FEL interaction. Moreover, the laser fields diminish the ...
In the beam pipe of the positron damping ring of the Next Linear Collider, electrons will be created by beam interaction with the surrounding vacuum chamber wall and give rise to an electron cloud. Several solutions are possible for avoiding the electron cloud, without changing the bunch structure or the diameter of the vacuum chamber. Some of the currently available solutions for preventing this spurious electron load include reducing residual gas ionization by the beam, minimizing beam photon-induced electron production, and lowering the secondary electron yield (SEY) of the chamber wall. We will report on recent SEY measurements performed at SLAC on TiN coatings and TiZrV non-evaporable getter thin films.
The kinetic energy transferred to some elements by an electron of kinetic energy 100 to 400 kV is discussed. The displacement rates are compared to the signal generation. (DCL)
The symposium reviewed the use of electronics in mining today. Subjects covered include control systems; remote sensing; telemetry; data transmission; microprocessors and transportation systems. 15 papers have been abstracted separately.
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1 MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was investigated. This dosimeter can give a rough estimation of the ...
In a positive polarity induction adder each of the induction cavities is a cathode, which emits electrons at a unique potential. These broad spectrum electrons strongly affect Magnetically Insulated Transmission Line (MITL) behavior. Electron flow decreases the cavity-to-MITL coupling efficiency, and reduces the power transport efficiency along the system. Also, the operating impedance of the MITL is lowered, reducing the diode impedance required for good coupling and good total system power efficiency. It is therefore imperative to understand the details of MITL electron flow. In previous work, measurement of MITL electron flow for a twenty-stage linear induction adder (Hermes III), operated in positive polarity, was compared with simulations. There was qualitative agreement, but some differences were noted. For example, measured electron flow in the first ...
We report the results of characterization of nonlinear refractive index of the composite material produced by MeV Ag ion implantation of LiNbO{sub 3} crystal (z-cut). The material after implantation exhibited a linear optical absorption spectrum with the surface plasmon peak near 430 nm attributed to the colloidal silver nanoclusters. Heat treatment of the material at 500 C caused a shift of the absorption peak to 550 nm. The nonlinear refractive index of the sample after heat treatment was measured in the region of the absorption peak with the Z-scan technique using a tunable picosecond laser source (4.5 ps pulse width). The experimental data were compared against the reference sample made of MeV Cu implanted silica with the absorption peak in the same region. The nonlinear index of the Ag implanted LiNbO{sub 3} sample produced at five times less fluence is on average two times greater than that of the reference. (orig.) 20 refs.
The /sup 40/Ca(p,n)/sup 40/Sc reaction was studied at 134 MeV. Neutron energy spectra were measured by the time-of-flight technique with resolutions of 220 keV at angles from 0"0 to 41"0 and 415 keV out to 62"0. The 2"-,3"-,4"-,5"- band of states based on the (f/sub 7/2/,d/sub 3/2//sup -1/) 1p1h structure was observed at low excitation energies, in good agreement with known analog states in /sup 40/Ca and /sup 40/K. The shapes of the cross-section and analyzing-power angular distributions are in good agreement with distorted-wave impulse-approximation calculations using simple 1p1h (Tamm-Dancoff approximation) shell-model wave functions. A relatively strong transition to a state at E/sub x/ = 2.3 MeV with L = 3 is identified tentatively as a 4"- state with the predominant 1p1h structure (1f/sub 7/2/,2s/sub 1/2//sup -1/).
Oxygen-16 induced fission studies of [sup 209]Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM [approx equal] mass units) with a peak near mass [approx equal] 108. The charge distribution in the [sup 16]O ion induced fission of [sup 209]Bi has also been studied at particle energy of 89.5 MeV. The relative cumulative yields of [sup 92]Sr, [sup 97]Zr, [sup 99]Mo, [sup 101]Mo, [sup 112]Pd and [sup 117m]Cd have been determined using gamma ray spectrometry. The width of charge distribution has been found to be broad. (orig.)
Oxygen-16 induced fission studies of "2"0"9Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM #approx =# mass units) with a peak near mass #approx =# 108. The charge distribution in the "1"6O ion induced fission of "2"0"9Bi has also been studied at particle energy of 89.5 MeV. The relative cumulative yields of "9"2Sr, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. The width of charge distribution has been found to be broad. (orig.).
The "1"6O induced fission studies of "2"0"9Bi have been carried out at particle energies of 89.5 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The yield distribution of fission products has been found to be broad (FWHM=16) with a peak near mass 107. The charge distribution in the "1"6O particle induced fission of "2"0"9Bi has been studied at "1"6O particle of 89.5 MeV. The fractional cumulative yields of "9"2Y, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"0"5Rh, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. (author). 7 refs., 2 tabs.
The differential cross sections for neutron emission in the reactions {sup 115}In(p,xn), {sup 115}In(d,xn), and {sup 113}Cd({alpha},xn) are measured and analyzed for proton energies 11.2 and 22.2 MeV, deuteron energy 22.3 MeV, and {alpha}-particle energies 26.8 and 45.2 MeV, respectively. The parameters of the nuclear-level density in the Fermi-gas model with negative energy shift are determined for the {sup 113}Sn, {sup 114}Sn, {sup 115}Sn, and {sup 116}Sn nuclei over a wide range of excitation energies. Analysis is performed in a statistical model that uses the Hauser-Feshbach mathematical formalism to describe multistage processes. It is shown that, as excitation energy increases, the parameter of the level density for these nuclei first decreases (this behavior is consistent with the predictions of the generalized model of a superfluid nucleus) and then increases (this points to the destruction of the nuclear-shell ...
Excitation functions ({alpha},3n) and ({alpha},4n) for {sup 209}Bi have been measured up to 60 MeV {alpha}-particle energy. The excitation functions are measured at 15{alpha}-particle energies by a stack foil technique in two steps. Excitation functions for the above two reactions have been reported for the first time in the energy range from 40 to 60 MeV. The measured experimental values are compared with the geometry-dependent hybrid (GDH) model in which the emission of particles prior to the equilibrium decay is taken into account whenever the interaction of projectile with the target nucleus is considered. It is found that the compound nucleus decay mechanism alone is unable to explain the experimental trend of our data. The initial exciton number 4 with different configurations has been tested and it is concluded that the configuration (2n + 2p + 0h) gives the best fit to the experimental data. (author).
Excitation functions (#alpha#,3n) and (#alpha#,4n) for "2"0"9Bi have been measured up to 60 MeV #alpha#-particle energy. The excitation functions are measured at 15#alpha#-particle energies by a stack foil technique in two steps. Excitation functions for the above two reactions have been reported for the first time in the energy range from 40 to 60 MeV. The measured experimental values are compared with the geometry-dependent hybrid (GDH) model in which the emission of particles prior to the equilibrium decay is taken into account whenever the interaction of projectile with the target nucleus is considered. It is found that the compound nucleus decay mechanism alone is unable to explain the experimental trend of our data. The initial exciton number 4 with different configurations has been tested and it is concluded that the configuration (2n + 2p + 0h) gives the best fit to the experimental data. (author).
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO{sub 2} layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. {copyright} {ital 1999 American Institute of ...
We demonstrate that the excess vacancies induced by a 1 MeV Si implant reduce the excess interstitials generated by a 40 keV Si implant during thermal annealing when these two implants are superimposed in silicon. It is shown that this previously observed reduction is dominated by vacancy annihilation and not by gettering to deeper interstitial-type extended defects. Interstitial supersaturations were measured using B doping superlattices (DSL) grown on a silicon-on-insulator (SOI) substrate. Implanting MeV and keV Si ions into the B DSL/SOI structure eliminated the B transient enhanced diffusion normally associated with the keV implant. The buried SiO_2 layer in the SOI substrate isolates the deep interstitials-type extended defects of the MeV implant, thereby eliminating the possibility that these defects getter the interstitial excess induced by the keV Si implant. copyright 1999 American Institute of Physics.
We calculate the masses of the resonances D{sub s0}{sup *}(2317) and D{sub s1}(2460) as well as their bottom partners as bound states of a kaon and a D{sup (*)} - and B{sup (*)} -meson, respectively, in unitarized chiral perturbation theory at next-to-leading order. After fixing the parameters in the D{sub s0}{sup *}(2317) channel, the calculated mass for the D{sub s1}(2460) is found in excellent agreement with experiment. The masses for the analogous states with a bottom quark are predicted to be M{sub B{sup *}{sub s0}}=(5696{+-}40) MeV and M{sub B{sub s1}}=(5742{+-}40) MeV in reasonable agreement with previous analyses. In particular, we predict M{sub B{sub s1}}-M{sub B{sub s0}}{sup *}=46{+-}1 MeV. We also explore the dependence of the states on the pion and kaon masses. We argue that the kaon mass dependence of a kaonic bound state should be almost linear with slope about unity. Such a dependence is specific to the ...
Obtained experimental data on integral cross sections (ICS) of inelastic scattering of 50.5 MeV #alpha# particles with the excitation of "6","7Li, "9Be, "1"2","1"3C, "1"4C, "1"4N, "2"0Ne, "2"4Mg, "2"8Si nucleus low-lying energy levels are discussed. Regularities, detected in the behaviour of ICS forward scattering for 20-90 deg angles and backscattering for 90-160 deg angles for the target-nucleus under investigation are considered. Effect of reaction open channel number on #alpha#-particle scattering ICS where n,p,d- and #alpha#-channels were considered as the main channels for all the target-nuclei, is discussed. Dependence of #alpha#-particle scattering ICS on the target-nucleus level excitation energy and dependences of reaction open channel number on the channel spin, calculated for 50.5 MeV #alpha# particles and different target nuclei are shown in the diagrams. It is noted that the observed regularities in the #alpha#-particle inelastic ...
Angular distributions of "6Li+"6Li elastic scattering were measured for E_l_a_b=5-40 MeV. An optical model analysis of these data together with older data of "7Li+"7Li elastic scattering taken at E_l_a_b = 8-17 MeV was performed with the aim to search for a ''global'' OM potential which describes elastic scattering in both Li-Li systems in a broad energy range. Both surface and volume absorbing potentials can be found which fulfill this requirement if a linear energy dependence is assumed of the depths of the real as well as the imaginary potential. These depths, if fitted to individual angular distributions, are found to vary in a correlated manner with the beam energy. This is taken as indication of strong coupling between elastic, inelastic, and reaction channels. This is corroborated by the existence of resonances in reaction channels at these energies where the potential depths are most pronouncedly changing. (orig.).
The new proton-induced nuclear reaction data for C, Fe, Cu and Pb for KASKAD-S have been generated using a newly developed data preparation system. The new system utilizes the NJOY and TRANSX codes to prepare these data with the latest evaluation instead of using the SADCO code with the built-in nuclear data. Auxiliary codes have been developed to help the conversion of TRANSX output into the reaction data for running the KASKAD-S. The basic nuclear data selected for this work are the LA150 and KAERI high energy files whose energy ranges are up to 150 and 250 MeV, respectively. The total neutron yields were calculated using KASKAD-S and the new reaction data up to 250 MeV bombarding energy. The calculations were compared with the measurements or MCNPX calculations when the measured data were absent. The comparison shows that our calculations give an overall good agreement with the measurements and MCNPX calculations except around 30 ...
Elastic scattering of 27.2 MeV #alpha# particles on "4"0Ca has been investigated. Differential cross sections have been measured in the angular range from 10 deg to 175 deg in the lab. system. The theoretical analysis has proceeded from the proposition that the results of a calculation based on the optical model in the range of small angles (less than 20 deg for "4"0Ca) are independent of parameters and shape of the potential employed. Elastic scattering of #alpha# particles at angles up to 50 deg has been calculated using three sets of the optical potential parameters in the energy range 23.37-28.92 MeV. In the range of small angles a rather similar behaviour of the calculated curves can be observed whereas in the range of medium and large angles these curves behave very differently. The success in the reproduction of the angular distributions for the entire energy range is indicative of the weak energy dependence of the optical potential ...
Inelastic scattering of 180 MeV {pi}{sup +} and {pi}{sup {minus}} from {sup 52}Cr shows an angular distribution for the 2{sub 2}{sup +} state at 2.96 MeV that differs greatly from the usual {ital L} = 2 shapes for 2{sup +} states. This state is perhaps the only case from pion-inelastic scattering in which standard distorted-wave impulse approximation models (including multistep and single-step responses) fail to reproduce the measured angular distribution. Furthermore, this unique excitation has been shown to have the features expected of a seniority-four proton excitation yet the pion data show charge symmetry. While coupled-channel calculations are not able to reproduce the pion data, they do agree with the shape observed for 42 MeV {alpha} particle scattering to this state, but the magnitude of the {alpha} scattering data is not consistent with a collective model and known {gamma} ray deexcitations. Scattering to the ...
Inelastic scattering of 180 MeV #pi#"+ and #pi#"- from "5"2Cr shows an angular distribution for the 2_2"+ state at 2.96 MeV that differs greatly from the usual L = 2 shapes for 2"+ states. This state is perhaps the only case from pion-inelastic scattering in which standard distorted-wave impulse approximation models (including multistep and single-step responses) fail to reproduce the measured angular distribution. Furthermore, this unique excitation has been shown to have the features expected of a seniority-four proton excitation yet the pion data show charge symmetry. While coupled-channel calculations are not able to reproduce the pion data, they do agree with the shape observed for 42 MeV #alpha# particle scattering to this state, but the magnitude of the #alpha# scattering data is not consistent with a collective model and known #gamma# ray deexcitations. Scattering to the first and third 2"+ states of "5"2Cr with ...
A Bragg curve counter equipped with an internal production target was developed for the measurements of double-differential cross-sections of fragment production induced by neutrons at energies of tens of MeV. The internal target permitted a large detection solid angle and thus the registration of processes at low production rates. In this specific geometry, the detection solid angle depends on the emission angle and the range of the particle. Therefore the energy, atomic number, and angle of trajectory of the particle have to be taken into account for the determination of the solid angle. For the selection of events with tracks confined within a defined cylindrical volume around the detector axis, a segmented anode was applied. The double-differential cross-sections for neutron-induced production of lithium, beryllium, and boron fragments from a carbon target were measured at 0 deg. for 65 MeV neutrons. The results are in good agreement with ...
We develop the formalism of a unified semi-microscopic description of low-energy proton and {alpha}-particle interaction with nuclei. We analyze elastic and inelastic proton scattering at the energy 25.05 MeV and {alpha}-particle scattering at the energy 104 MeV by the {sup 90}Zr nucleus. Information is obtained on differences in the deformation of the proton and neutron distributions. We study the energy dependence of the semi-microscopic {alpha}-particle potential including the energy dependence of the potential geometry.'' We analyze the change in angular distributions of elastically scattered {alpha} particles with increase of energy and the contribution to the scattering cross section from nucleon-nucleon correlations.
The analysis of elastic and inelastic scattering of #alpha# particles with energy of 50 MeV by nuclei with mass numbers A=54-124 and of "3He particles by the nucleus "6"4Ni is given in the framework of the optical model. The parameters of multipole deformations for lower states are determined. The parameters for quadrupole and octupole deformations of the potential for the nucleus "1"1"2Sn are extracted, the values of the hexadecupole deformation #beta#_4 of the potential for nuclei "9"4Zr, "1"2"0","1"2"4Sn are found. Information is extracted on the ratio of deformation parameters for the neutron and proton components in lower collective states (2_1"+, 3_1"-) of nuclei with A=90-124.
An opportunity to study the system {sup 22}Ne+{sup 208}Pb in the proximity of the Coulomb barrier with the PRISMACLARA apparatus was given by a test of the PIAVE-ALPI accelerator in mid-December 2005. The {sup 22}Ne projectiles, having the kinetic energy of 131 MeV, collided with a {sup 208}Pb target 300 {mu}g/cm{sup 2} thick. (The beam was run for {approx}20 hours with a current of {approx}6 particle-nA). The reaction products, mainly originated by scattering or transfer processes, were detected by the PRISMA spectrometer (positioned in the proximity of the grazing angle, {approx}70 degrees), coupled to the CLARA array of germanium detectors.
Experiments have been carried out in water at 355 C to study transport of oxygen and hydrogen (as deuterium) in growing corrosion films. Composition of the films was also examined in 2.9 Mev and 3.9 Mev /alpha/-particle backscattering experiments. Corrosion occurs predominantly by oxygen diffusion through the film via grain boundary or similar short circuit diffusion paths, to form fresh oxide at the oxide metal interface. Increasing grain size within thick pre-breakaway films contributes to a decrease in diffusivity. The rate transition results from the generation of new diffusion pathways in previously protective oxide. Unexpectedly high concentrations of deuterium were observed. 26 refs.
The results on 5 K irradiation available so far may be summarized as follows. (1) Increases of j/sub c/ following neutron irradiation occur only in conductors which are far from the optimal metallurgical treatments. (2) The changes of j/sub c/ following neutron irradiation and a thermal cycle to room temperature are small and in most cases comparable to the results obtained after 77 K irradiation. (3) The data available so far indicate that the degradation of j/sub c/ at 8 T is larger by about 5 to 10% than the corresponding changes at 5 T at a neutron fluence of 1.3 x 10/sup 22/ m/sup -2/ (E > 0.1 MeV). (4) The increase of Cu-resistivity is significant even after a thermal cycle to room temperature and requires design changes for a stable magnet operation.
The energy spectra and angular distributions of proton emission in a reaction of {sup nat}Fe(n,xp) at a neutron energy of 14.6 MeV are measured by the University of Science and Technology of China multitelescope system. The double-differential cross sections of 16 reaction angles from 25 to 164.5 deg are obtained in this measurement. The statistical errors are reduced largely because of the thick target used. The angular distributions show a slightly energy-dependent forward-backward asymmetry. The angle-integrated proton spectrum is compared with theoretical calculations and other results. The total proton-emission cross section is in fair agreement with the prediction and evaluation.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV /sup 40/Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV /sup 40/Ar ions exhibits a satisfactory Z separation around Z = 18.
By using Bragg curve spectroscopy, one can measure atomic number and energy of high energy heavy ions stopping in a gas-filled ionization chamber with longitudinal electric field. In this paper, we report on the results obtained with an isobutane filled detector. An energy resolution of 0.8% fwhm and a Z resolution of 2.7% fwhm were achieved for elastically scattered 300 MeV "4"0Ar ions. We study the Bragg peak amplitude dependence on the energy of the incoming ions, a dependence presumably due to the Frisch grid screening inefficiency. The corrected Bragg peak spectrum of inelastically scattered 300 MeV "4"0Ar ions exhibits a satisfactory Z separation around Z = 18. (orig.).
The fully depleted pn-junction charge coupled device (pn-CCD) has been developed as a detector for X-ray imaging and high-resolution spectroscopy for the X-ray satellite missions XMM and ABRIXAS. If the detector is exposed to a particle radiation environment, the energy resolution is degraded due to charge transfer losses and a dark current increase. In a first experiment, prototype devices were irradiated with 10 MeV protons. After completion of the detector development, the proton irradiation was repeated for a quantitative study of the radiation damage, relevant for the satellite missions. The irradiation test was extended by a 5.5 MeV {alpha}-particle and a 6 keV X-ray exposure of the pn-CCD, including the CAMEX preamplifier chip.
A new method of determining the nuclear level density is presented. This method is based on the statistical analysis of the partial width fluctuations appearing in an excitation function of the radiative proton capture. The method was applied in the case of the /sup 88/Sr(p,..gamma..sub(..omega..))/sup 89/Y and /sup 89/Y(p,..gamma..sub(..omega..))/sup 90/Zr reactions. The density of levels with spin I/sup -/ in /sup 90/Zr and the densities of levels with spins 1/2/sup +/ and 3/2/sup +/ in /sup 89/Y at excitation energies from 10.9 to 11.6 MeV and from 9.3 to 10.8 MeV respectively, were determined with an uncertainty of about 35%.
We compare standard nuclear polarization mechanisms, ..delta..-hole-polarization and meson-exchange-current effects in the q-dependent quenching of isovector spin transitions. Calculations are performed for the M1-transition form factors of the 1/sup +/ states in /sup 48/Ca (10.23 MeV) and /sup 88/Sr (3.48 MeV). We obtain a satisfactory description of both form factors if the repulsive part of the residual interaction in the ..delta..-hole channel is of similar strength to that in the nucleon-hole channel. Meson-exchange currents lead to an enhancement of M1 transitions by an amount which is small in general, but sensitive to the particular nuclear state involved. 44 references.
We compare standard nuclear polarization mechanisms, #DELTA#-hole-polarization and meson-exchange-current effects in the q-dependent quenching of isovector spin transitions. Calculations are performed for the M1-transition form factors of the 1"+ states in "4"8Ca (10.23 MeV) and "8"8Sr (3.48 MeV). We obtain a satisfactory description of both form factors if the repulsive part of the residual interaction in the #DELTA#-hole channel is of similar strength to that in the nucleon-hole channel. Meson-exchange currents lead to an enhancement of M1 transitions by an amount which is small in general, but sensitive to the particular nuclear state involved. (orig.).
The neutron-induced fission cross-section of {sup 233}U has been measured at the CERN n-TOF facility relative to the standard fission cross-section of {sup 235}U between 0.5 and 20MeV. The experiment was performed with a fast ionization chamber for the detection of the fission fragments and to discriminate against {alpha} -particles from the natural radioactivity of the samples. The high instantaneous flux and the low background of the n-TOF facility result in data with uncertainties of {approx} 3%, which were found in good agreement with previous experiments. The high quality of the present results allows to improve the evaluation of the {sup 233}U (n,f) cross-section and, consequently, the design of energy systems based on the Th/U cycle. (orig.)
M-shell X-ray production cross sections for the light rare-earth elements of {sup 68}Er, {sup 7}Yb and {sup 71}Lu have been measured for incident {sup 4}He{sup +} ions in the energy range from 0.75 to 6 MeV. The measured X-ray production cross sections are compared to the predictions of the First Born approximation, the ECPSSR theory and the ECUSAR theory. A comparison of the ytterbium M-shell X-ray production cross sections with these theories is made for two different sets of fluorescence yields and Coster-Kronig factors that are further modified for multiple ionization.
The total photoabsorption cross section on a free proton was measured at the GRAAL facility in the energy range E ? = 600?1500 MeV. The large-aperture LAGRAN?E detector and a liquid hydrogen target were used in the experiment performed with a back-scattered Compton gamma beam. To improve the accuracy, two alternative methods were employed. First, a subtraction method of using empty-target measurements allowed the cross section ? tot to be evaluated directly because of a low level of the electromagnetic background. Second, an algorithm for evaluating ? tot on the basis of summing the dominating partial cross sections was developed. Experimental results obtained for ? tot by the two methods are compared with existing data.
The magnetic pyrochlore Er{sub 2}Ru{sub 2}O{sub 7} has been studied with neutron scattering and susceptibility measurements down to a base temperature of 270 mK. For the low temperature phase in which the Er sublattice orders, new magnetic Bragg peaks are reported which can be indexed with integer (hkl) for a face centered cubic cell. Inelastic measurements reveal a wealth of crystal field levels of the Er ion and a copious amount of magnetic scattering below 15 meV. The three lowest groups of crystal field levels are at 6.7, 9.1 and 18.5 meV.
Lifetime observations on a group of 358 rhesus monkeys indicate that life expectancy loss from exposure to protons in the energy range encountered in the Van Allen belts and solar proton events is influenced primarily by the dose rather than the energy of radiation. After 24 years, life expectancy losses from similar surface doses of low-LET (138-2300 MeV) and high-LET (32-55 MeV) protons are not significantly different, but the high-LET protons are associated with more deaths in the early years, while the low-LET protons contribute more to mortality in later years. In males, the most significant cause of life shortening is nonleukemia cancers.
K-shell x-ray production cross sections and K#beta#/K#alpha# ratios have been measured for thin targets of Ti, V, Cr, Fe, Ni, Cu, Zn, Ga, As, Se, Rb, Sr, and Y for 0.5- to 2.5-MeV alpha particles. The experimental values are compared to the nonrelativistic plane-wave Born approximation (PWBA), the binary-encounter approximation, and the PWBA with binding energy and Coulomb deflection corrections. The PWBA with corrections provides the best agreement with the experimental cross sections.
Specimen damage and element loss induced by 3 MeV proton and 2 MeV alpha particle bombardment of thin sections of freeze-dried kidney tissue and embedding medium have been studied. Yields of ions scattered from H and C, and characteristic X-rays were measured versus accumulated charge, for curent densities in the range from 8x10{sup -15} to 1.1x10{sup -11} A/{mu}m{sup 2}. Structural damage, dissolouration and loss of S, Cl, C and H have been observed. Implications of this study for ion beam microanalysis of biological tissues are discussed with particular reference to the results for H loss. (orig.).
The resonant scattering of bremsstrahlung #gamma#-rays by a SrCO_3 target has been studied for #gamma#-ray energies of 5-11 MeV. Six #gamma#-transitions of energies between 6-8 MeV, which indicate six resonant states in "8"8Sr, were observed. The relative intensities of the resonantly scattered #gamma#-rays at 125 and 150"0 were found to be compatible only with the assignment of spin 1 to the six states. Radiative widths of the resonant states were deduced. The possibility that these states are components of the giant M1 resonance in "8"8Sr is discussed. (orig.).
Data from Monte Carlo transport codes are used to model radiobiological effects. We previously reported the Fourier analysis of ionization data generated by simulating a 500-keV proton traversing water. Here, we extend Fourier analysis to energy transfer data of another radiation type, a 14-MeV #alpha#-particle. A radiobiological model based on this frequency-domain analysis views cell as an information processing system . It lends itself naturally to traditional engineering analyses. One engineering principle-the output response of a linear system to random signal-is applied here to explain the fact that there is measurable difference in the magnitude of the biological effectiveness when a given biological system is irradiated with two different radiation types of the same Linear Energy Transfer (LET).
The phenomenon of radiation blistering by helium ion bombardment has been the subject of extensive studies in recent years because of its technological importance in thermonuclear fusion devices and reactors. However, the mechanism of radiation blistering is still not well understood. There are two different models of blister formation: the gas-pressure model and the lateral stress model. The former model is, however, supported by many experimental observations, the prominent one is that of Evans and Eyre who observed blisters appearing on the front and rear surfaces of a thin wedge-shaped molybdenum foil irradiated by helium ions. Their experiment also indicates that the thickness of the irradiated specimen could be important in affecting the characteristics of blisters. With this in view, we have studied the development of blisters in thin foils of tantalum by 30 MeV ..cap alpha..-particle bombardment.
The phenomenon of radiation blistering by helium ion bombardment has been the subject of extensive studies in recent years because of its technological importance in thermonuclear fusion devices and reactors. However, the mechanism of radiation blistering is still not well understood. There are two different models of blister formation: the gas-pressure model and the lateral stress model. The former model is, however, supported by many experimental observations, the prominent one is that of Evans and Eyre who observed blisters appearing on the front and rear surfaces of a thin wedge-shaped molybdenum foil irradiated by helium ions. Their experiment also indicates that the thickness of the irradiated specimen could be important in affecting the characteristics of blisters. With this in view, we have studied the development of blisters in thin foils of tantalum by 30 MeV #alpha#-particle bombardment. (orig.).
We have developed an energy-extension method of a Bragg curve counter (BCC) at the high-energy end for the measurements of double-differential cross-sections (DDXs) of fragment productions induced by tens of MeV protons. In this method, we estimate the incident energies of the fragments penetrating a BCC on the basis of the energy loss and atomic number (Z). We applied this method to the DDX measurements of the {sup nat}C(p, Li) and {sup nat}C(p, Be) reactions induced by 70 MeV protons. The validity of this method has been confirmed by comparing the DDXs of beryllium with theoretical predictions of the PHITS code and the two-body kinematics. This method improves the energy acceptance of the BCC for light fragments twice as wide as that of a conventional method without remodeling of the BCC and any loss of the original advantages.
Shadow effect was used for investigating damage of uranium dioxide monocrystal. The dependence of shadow minimum parameters on fluence of "2"2Ne ions with 172 MeV energy was followed when detecting fission fragments. Ion dose responsible for sufficient microdamage of lattice structure, included into the classification of heavy ion damage effect on monocrystals was determined. The problem of radiation intensity effect on the character of occurred damages was studied. It was established that macroscopic sample failure, caused by generation of considerable mechanical stresses in monocrystal under beam effect could be observed along with microdamages of lattice structure at ion flux density >10"1"2 cm"-"2Xs"-"1.
Researchers report results from the Low Energy Antiproton Experiment (LEAP), a balloon-borne instrument which was flown in August, 1987. They found a value of 4.2 by 10-6 for the antiproton to proton ratio in the energy range from 120 MeV to 600 MeV at the top of the atmosphere. In particular, this experiment places an upper limit on the flux almost an order of magnitude below the reported flux of Buffington et al. This upper limit allows us to place significant constraints on both the primordial black hole and weakly interacting Majorana Fermion hypothesis, as well as on the low energy processes in more conventional models of galactic cosmic ray antiproton production.
Dose dependences of conductivity at a temperature of 78 K for InSb and InAs single crystals under reactor fast neutron, 50 MeV proton and 80 MeV alpha particle irradiation up to fluence of 10{sup 17} cm{sup -2} are considered. Special attention is given to non-trivial, but little known semi-conductor characteristics in terms of {sigma}(F) dependence at large fluences, and also to the versatility of such dependence for all semiconductors. The behaviour of semiconductor materials conductivity dependence on fluence presented here may be used for semiconductor dosemeters characterisitic variation forecasting under large fluence measurements and in radiation emergency dosimetry. (author).
The simultaneous hydrogen and silicon atom densities in amorphous silicon, a-Si, films prepared by the glow discharge technique have been measured by 25 MeV #alpha#-particle elastic scattering. Integrated band intensities for the silicon-hydrogen stretching modes, #omega#_1sup(s) and #omega#_2sup(s) in the region 1800 to 2200 cm"-"1 were determined for the same freely supported films. A similar analysis has been carried out for the bands observed at 890, 840 and 640 cm"-_1. Effective oscillator strengths for the #omega#_1sup(s) and #omega#_2sup(s) modes in a-Si films have been estimated and compared with the current theories on the effect of the silicon matrix on the infrared absorption characteristics. (author).
Summation Copper-64 (T1/2?=?12.7 hours; ?+, 0.653?MeV [17.8 %]; ??, 0.579?MeV [38.4 %]) has decay characteristics that allow for positron emission tomography (PET) imaging and targeted radiotherapy of cancer. The well-established coordination chemistry of copper allows for its reaction with a wide variety of chelator systems that can potentially be linked to peptides and other biologically relevant small molecules, antibodies, proteins, and nanoparticles. The 12.7-hours half-life of 64Cu provides the flexibility to image both smaller molecules and larger, slower clearing proteins and nanoparticles. In a practical sense, the radionuclide or the 64Cu-radiopharmaceuticals can be easily shipped for PET imaging studies at sites remote to the production facility. Due to the versatility of 64Cu, ...
The LAHET code system calculations and experimental results for proton interactions with an energy <50 MeV are compared. For these energies, the theories behind the LAHET models are not applicable. Three quantities compared are (a) the magnitude of the neutron yield generated through proton interactions, (b) the energy and angular distributions of the resultant neutrons, and (c) the residual nuclei produced by proton interactions (spallation products). The comparisons are for protons incident on iron and copper, except in the case of the energy and angular distributions, which are calculated only for iron. The neutron yields predicted by LAHET agree with published measurements to within 50% for both materials. For iron, the predicted energy and angular distributions agree to within a factor of 3. Finally, the predicted spallation product yields of both materials agree with measurements to within a factor of 4.
The "1"2C induced fission of "2"0"9Bi at particle energy of 84.2 MeV has been studied using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The charge distribution has also been studied and the relative fractional cumulative yields of "9"2Y, "9"7Zr, "9"9Mo, "1"0"1Mo, "1"0"5Rh, "1"1"2Pd and "1"1"7"mCd determined. The yield distribution of fission products has been found to be broad (FWHM #approx =# 18) with a peak near mass #approx =# 105. (author). 7 refs., 2 tabs.
Ionizing radiations that differ in number, size, and distribution of energy deposition events might be expected to cause different effects for the same absorbed dose. Furthermore, microdosimetry calculations suggest that large variations in biological effectiveness might be expected for internally deposited alpha-emitting radionuclides for the same absorbed dose, depending upon the specific activity and spatial distribution of the sources in tissue. The study described in this article was designed to demonstrate these phenomena in vitro. Cultured Chinese hamster ovary (CHO-K1 BH4) cells were exposed in vitro to inert, insoluble ceramic microspheres in zirconium dioxide labeled with "2"3"9Pu. The average exit energy of the 5.15 MeV alpha particle was calculated to be 4.3 MeV. Exposure times varied from four to seven hours to achieve the desired dose level.
The alpha particle induced fission of {sup 209}Bi has been investigated for E{sub {alpha}} = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of {sup 97}Zr, {sup 99}Mo, {sup 101}Mo, {sup 112}Pd and {sup 117m}Cd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).
The alpha particle induced fission of "2"0"9Bi has been investigated for E_#alpha# = 55.7 and 58.6 MeV using gamma ray spectrometry. The cross sections for the production of fission products have been determined. The mass distributions have been found to be broad with a peak near mass 104. The charge distribution has been studied at the same particle energies. The fractional cumulative yields of "9"7Zr, "9"9Mo, "1"0"1Mo, "1"1"2Pd and "1"1"7"mCd have been determined using gamma ray spectrometry. The width of charge distribution is broad. (orig.).
Measurements of alpha spectra in the (n, #alpha#) reactions induced on /sup 90,91/Zr at 14.3 and 18.15 MeV incident neutron energy are presented. A microscopic calculation of these spectra has been made using both pick-up and knock-on theories, and in both cases only one overall normalizing factor, which is the same for the two target nuclei and incident energies and all the considered transitions, appears as a free parameter in the calculation. Pick-up calculations provide a very satisfactory reproduction of the data. Knock-on calculations reproduce many qualitative features of the measured spectra, but do not allow a fully satisfactory reproduction of them. While the results obtained do not exclude knock-on contributions to these reactions, their presence is not established.
Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.
Differential cross sections of the (#alpha#, t) reactions on "4"5Sc, "5"1V, and "5"9Co nuclei are measured in the 10-71 deg, 10-155 deg, and 10-171 deg angular ranges, respectively, with 27.2 MeV alpha particles. The cross sections have also been calculated on the basis of the distorted wave theory. The possibility of an unambiguous choice of the optical potential for alpha particles is discussed. The angular distribution calculations using several combinations of the optical potentials in the inlet and outlet channels of the reactions show that consistence between the calculations and the measurements is achieved (especially in angular range, less than 90 deg, if one of the potentials is chosen to be a sufficiently deep one.
The cross section database for electron impact excitation and electron impact ionization for hydrogen beam kinetic energies greater than 100 eV was considered, giving for each particular process a reference to a recommended publication of cross sections, as well as the accuracy or estimated accuracy. The work is motivated by the application of neutral beam injection in magnetic confinement devices, such as large tokamaks. 9 refs, 2 figs.
Electron Cyclotron Heating experiments have been performed on the TEXT tokamak using Varian gyrotron. Some degradation of electron energy confinement is observed for sawtoothing and non-sawtoothing discharges. Sharp electron temperature profiles are produced in high-q discharges by extremely localized ECH power deposition.
The polarization characteristics of spontaneous radiation from relativistic electrons moving through helical and planar wiggler fields are evaluated for imperfect beam injection. Maximum coherent gain in free-electron laser systems are seen to occur in optical fields having these polarization characteristics rather than those of the wiggler magnets. Coupling coefficients for an electron beam skewed at an angle to the optical mode are presented.
We report the homodyne detection of phase modulation sidebands induced on a laser beam by a coherently bunched electron beam. This provides a sensitive and nonperturbing measurement of complex Fourier time series components of the electron density. A proof-of-principle measurement of the microwave frequency component of electron density in a crossed-field device, which agrees well with a calculation of the same quantity, is reported.
The authors study the nonuniformity of a-Si:H films obtained by the method of vacuum condensation, with the help of x-ray small-angle scattering (SLS) and transmission electron microscopy. Films of hydrogenated amorphous silicon are greatest interest, because the electronic properties of this material can be controlled by doping. As a result of the compensation of the ruptured bonds, and possibly, effects of melting, the properties of such films are analogous to those of singlecrystalline silicon. XLS enables a quantitative determination of the prameters of the regions of low electron density (RLD) in such objects.
Using the experimentally determined cutoff energies of the muon-electron and the pion-electron conversion curves in a tachyon-bradyon model of the electron and the muon, the magnetic moments of these particles have been derived and found to be the Bohr magnetons identically. The tachyons, being bound to the bradyons and unable to drop below the speed of light, cause the bradyons to revolve in an orbit. It is this orbital motion of the charged bradyons that generates the magnetic moments.