The US Department of Energy (DOE) sponsors an extensive research program to improve the methods, dosimeters, and instruments available to DOE facilities for measuring neutron dose and assessing its effects on the work force. The Total Dose Meter was recently developed for measuring in real time the adsorbed dose of mixed neutron and gamma radiation and for calculating the dose equivalent. The Field Neutron Spectrometer was developed to provide a portable instrument for determining neutron spectra in the workplace for flux-to-dose equivalent conversion and quality factor calculation. The Combination Thermoluminescence/Track Etch Dosimeter (TLD/TED) was developed to extend the effective neutron energy range of the conventional TLDs to improve detection of fast-energy neutrons. An Optically Stimulated Luminescence Dosimeter ...
Manned-space missions bring an exposure due to corpuscular radiations of which nature is quite different from what we encounter in the ground environment. In the space environment, many secondaries are produced through interactions of cosmic ray primaries with the spacecraft wall and other surrounding materials. Among this large variety of radiation components in the space, the contribution of neutrons to the radiation exposure of astronauts has remained to be studied. Up to today, efforts to measure neutron dose equivalent have been made using passive detector systems. Considering uncertainties involved in current measurements and estimations of high energy neutrons, and their increasing importance for future manned missions, it is necessary to measure neutron spectrum in the spacecraft under realistic conditions. The neutron spectra have never been measured on ...
An original evaluating method of gain degradation has been found for neutron irradiated transistors. It establishes a correlation between degradation and the product of two coefficients: spectra factor and an electrical parameter which is measured or directly deduced from manufacturer's data. Equivalence for several type of spectra (fission, 14MeV and degradation sensitivity to electrical parameters values of individual components of a batch are obtained.
From optical point of view and due to the magnetic interaction of the cold neutrons with the unpaired electron shell, magnetic materials hae a neutron spin-dependent refractive index n[sup +] [spin up] and n[sup -] [spin down]. Magnetic media such as Fe, Co and Ni react like birefringent uniaxial crystals in ordinary optica. n[sup +] and n[sup -] are the equivalent of the ordinary and extraordinary refractive indices. The specular reflection of spin polarized neutrons which is due to the discontinuity of the magnetic induction at the surface of the ferromagnet is a sensitive probe of surface and interface magnetism. We shall first give the background of the art of polarized neutron optics. Secondly, some recent examples from surface and interface magnetism will be given to illustrate the power of this technique such as the magnetic coupling in thin films and multilayers and flux ...
The personal neutron dosimetry becomes more important with the increasing use of nuclear and accelerator facilities. The solid state track detector, film badge and thermo-luminescent dosimeter have widely been used as passive-type personal neutron dosimeters, but the real-time neutron dosimeter is strongly needed. A real time personal dosimeter which could give neutron dose equivalent over wide energy range from thermal to 10 odd MeV by using two neutron sensors has been developed by our group. For practical commercial product, some changes from these prototype sensors have recently been done by Fuji Electric Co. Ltd. The purpose of this work is the final performance test of the dosimeter just before sale. We checked again about the sensitivity in the monoenergetic neutron field from 8 keV to 15 MeV and in the neutron ...
The Tissue Equivalent Proportional Counter (TEPC) was developed to monitor low level neutron exposure rates at working stations in a nuclear fuel fabrication facility. It has proven capable of accurately measuring neutron dose rates at levels from 0.1 to 0.2 mrem/hr. It also calculates the Quality Factor which is of importance in locations where the neutron to gamma ratio may vary significantly and irregularily. The system described is computerized to monitor 100 work locations simulationeously and can be expanded to monitor 384 locations. Neutron dose is accumulated on a real time basis and after the proton drop point is established, dose rate can be read out at any time for the dose accumulated over a specified period of time. The current development program which provides reduced system maintenance, lower detection limits, and improved accuracy is discussed along with examples of ...
A detector has been developed and used to measure dose distributions versus linear energy transfer to thin gas targets in spherical geometry from fast neutron irradiation of tissue-equivalent plastic and carbon. The detector is a hemispherical proportional counter with a Cs(T1) scintillator at the center of the hemisphere. The coincidence of the proportional counter signals constrain the measurements to charged particles traversing the radius of the hemisphere. The charged particle energy deposition distributions are directly measured for a known pathlength. The A-150 kerma factor was measured at a neutron energy of 14.8 MeV and is in agreement with tabulated values. The carbon kerma factor measurements are less than the tabulated value at 14.8 MeV. The alpha-particle production in carbon was measured for neutron energies from 14.1 to 14.8 MeV and is compared with existing data.
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...
Neutron and gamma ray energy spectra were measured using an NE-213 scintillator at depths of 7.2, 15.2, and 22.2 cm in a tissue-equivalent phantom which was uniformly irradiated on one face by deuterium--tritium (DT) neutrons. Coupled neutron--gamma ray multigroup discrete-ordinates calculations were performed using semi-infinite slab geometry. These calculations were used to supplement the measured spectra below 1MeV. Similar calculations were performed to study the perturbation in the phantom due to the detector. The measured and calculated spectra were used to determine the kerma distributions for neutrons and gamma rays at each location. The gamma radiation was determined to contribute more than 10% of the total dose at each depth. The calculated kerma also reveals that a knowledge of the gamma ray spectra below 1 ...
A comprehensive attenuation data of dose equivalent for point isotropic monoenergetic neutron sources up to 400MeV in infinite shields of water, ordinary concrete and iron has been calculated using the ANISN-JR code and a neutron-photon multigroup macroscopic cross section HIL086R. The attenuation factors were fitted to a 4th order polynomial exponent formula, making possible to use easily for point kernel codes. Additional data in finite shielding geometry was also calculated to correct the effect due to infinite medium, giving the maximum correction of 0.23 in the region for more 400 cm distance from neutron source of 400 MeV in iron shield. Effective attenuation length for monoenergetic neutrons have been studied in detail. Subsequently, it was shown that the attenuation length was strongly dependent upon the penetration length and the Moyer`s formula using a single attenuation ...
The development of a flat response small size, real time neutron dosimeter and ratemeter for the energy range of about 1 eV to 14 MeV is presented. This dosimeter is adequate for measuring neutron dose equivalents of 3 mRem up to 100 Rem and dose rates of 300 mRem/h to 50 Rem/h or more. The dosimeter consists of four Si surface barrier detectors. _1_0B radiators are placed in front of three of the detectors and a polyethylene radiator is placed in front of the fourth one. The _1_0B pellets are used for dose equivalent measurements in the energy range 1 eV to proportional1MeV. The polyethylene radiator, made in two parts having thicknesses of 10 and 100 mg/cm_2 in an area ratio of 8 to 1, flattens the response to +-40% in the energy range 1-14 MeV. The signal-to-background ratio for different Si surface barrier detectors and for _1_0B polyethylene radiators was ...
To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca{sub 2}SO{sub 4}:Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose ...
We have carried out numerical simulations of strongly gravitating systems based on the Einstein equations coupled to the relativistic hydrodynamic equations using adaptive mesh refinement (AMR) techniques. AMR coalescences of neutron stars can now be simulated with sufficient resolution covering the neutron stars while having the computational domain extend to the local wave zone. We show an AMR simulation carried out with a workstation having an accuracy equivalent to that of a 1025^3 regular uni-grid simulation, which is, to the best of our knowledge, larger than all previous simulations of similar NS systems on supercomputers. We believe the capability opens new possibilities in general relativistic simulations.
A clean benchmark experiment on beryllium was performed with D-T neutrons at the FNS facility of the Japan Atomic Energy Agency. The main objective was to verify the integral data related to the tritium production on lithium isotopes. Tritium production rates, as well as activation reaction rates were measured inside the beryllium assembly that was shaped as a pseudo-cylindrical slab with an area-equivalent diameter of 628 mm and a thickness of 355 mm. Experimental results were analyzed with a three-dimensional Monte Carlo transport code MCNP-4C and FENDL/MC-2.0, JENDL-3.2/3.3 neutron transport libraries. Evaluation of reaction rates was based on the cross section data taken from the JENDL Dosimetry File and ENDF B-VI data libraries. Analysis shows that all calculation combinations (transport and activation cross section libraries) used for evaluation of reaction rates give data that is agreeable with measured values within ...
Target vessel materials used in spallation neutron source will be exposed to proton and neutron irradiation and mercury immersion environments. In order to evaluate the surface degradation of the vessel candidate materials due to such environment, the triple-ion beam irradiation taking the spallation reaction into account and mercury immersion tests were carried out. Mechanical properties of the gradient surface layer were evaluated by the inverse analysis with multi-layer model that considers distribution of surface characteristic was applied to the load and depth curves measured by using the instrumented indentation machine. Transmission electron microscopic observations were performed to evaluate the changes of microstructure in irradiated surface layer using focused ion-beam cut micro-specimen. The mechanical properties distributions in the surface layer were evaluated quantitatively and the changes in microstructures were correspondent to ...
The X-ray spectra of some magnetized isolated neutron stars (NSs) show absorption features with equivalent widths (EWs) of 50 - 200 eV, whose nature is not yet well known. To explain the prominent absorption features in the soft X-ray spectra of the highly magnetized (B ~ 10^{14} G) X-ray dim isolated NSs (XDINSs), we theoretically investigate different NS local surface models, including naked condensed iron surfaces and partially ionized hydrogen model atmospheres, with semi-infinite and thin atmospheres above the condensed surface. We also developed a code for computing light curves and integral emergent spectra of magnetized neutron stars with various temperature and magnetic field distributions over the NS surface. We compare the general properties of the computed and observed light curves and integral spectra for XDINS RBS\\,1223 and conclude that the observations can be explained by a thin hydrogen atmosphere above ...
The equivalence of representations of symmetry groups operating upon wave-functions in configuration space is studied with regard to the (intuitive) notion of physical equivalence. A refinement of the usual projective equivalence relation is introduced, called gauge equivalence, for which the allowed unitary equivalence transformations are gauge transformations. For a Euclidean as well as for Newton-Hooke symmetry group the gauge equivalence classes of unitary multiplier representations are determined. These examples support the assertion that equivalence from a physical viewpoint corresponds better to this new gauge equivalence concept than to the usual notion of projective equivalence. (author).
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeVneutronequivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
The RD50 collaboration has been exploring the development of radiation hard semiconductor devices for very high-luminosity colliders since 2002. The target fluence to qualify detectors set by the anticipated dose for the innermost tracking layers of the future upgrade of the CERN large hadron collider (LHC) is 1016 1MeVneutronequivalent (neq) cm-2. This is about an order of magnitude higher than the maximum dose for the most exposed silicon detectors in the current machine. RD50 investigates the radiation hardening of silicon sensors from many angles: improvement of the intrinsic tolerance of the substrate material, optimisation of the readout geometry and study of novel design of detectors. A review of some of the recent activities within RD50 is here presented.
In calibration measurements with low energy X-rays, a double peak effect appears in low pressure proportional counters with a helix, when used for simulation of tissue equivalent diameters considerably larger than 2 m. An interpretation of this phenomenon is discussed, based upon electron capture and electric field perturbation at the counter helix. A description of the physical processes is presented showing that the double peak effect is a problem in the case of helix counters (called also Rossi counters) for all simulated diameters. Conclusions are drawn on systematic errors introduced by the counter helix into microdosimetric spectra and anti y/sub D/ of photons and neutrons. The authors recommend to use cylindrical counters with optimized geometrical and electronic parameters rather than the spherical counters with a helix discussed.
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
The Effective Dose Equivalent Concept defined by the International Commission on Radiological Protection in 1977 considers the risk from irradiation including both hereditary and somatic effects. This paper will deal with the definition of a concept for somatic effects only, the somatically significant dose equivalent. This is defined as the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by various individuals. The somatically effective dose equivalent for a particular radiopharmaceutical is the weighted sum of the average dose equivalent to various organs. The dose equivalent to various organs can be derived from an extended MIRD formalism also considering the rest of body excluding the source ...
Lithium Ceramics offer tremendous potential as a source for the production of tritium ("3H) for fusion power reactors. Their successful application will depend to a great extent upon the diffusion properties of the "6Li within the matrix. Consequently knowledge of "6Li concentration gradients in the ceramic matrices is an important requirement in the continued development of the technology. In this investigation, the neutron depth profile (NDP) technique has been applied to the study of concentration profiles of "6Li in lithium aluminate ceramics, doped with 1.8%, 50% and 95% "6Li isotopic concentrations. Specimen for analysis were prepared at Battelle (PNL) as pellet discs. Samples for diffusion studies were arranged as diffusion couples in the following manner: 1.8% "6Li discs/85% "6Li powder. Experiments were performed at the Texas A and M Nuclear Science Center Reactor Building, utilizing 1 MW equivalent thermal neutron ...
First structural wall material (FSW) materials in inertial fusion energy (IFE) power reactors will be irradiated under typical repetition rates of 1-10 Hz, for an operation time as long as the total reactor lifetime. The main objective of the present work is to determine whether a continuous-pulsed (CP) approach can be an efficient method in modeling the pulsed activation process for operating conditions of FSW materials. The accuracy and practicability of this method was investigated both analytically and (for reaction/decay chains of two and three nuclides) by computational simulation. It was found that CP modeling is an accurate and practical method for calculating the neutron-activation of FSW materials. Its use is recommended instead of the equivalent steady-state method or the exact pulsed modeling. Moreover, the applicability of this method to components of an IFE power plant subject to repetition rates lower than those of the FSW is ...
A working group (SC 45B/WG B8) exists within the international electrochemical commission (IEC) which is working on the combination and revision of the IEC standards 61283, 61323, 61344, 61525 and 61526. All these standards concern direct reading, electronic, personal dose equivalent meters for the quantities H{sub p}(10) and H{sub p}(0,07); they are different with regard to the kind of radiation (photons, and/or beta rays and/or neutrons). The new standard with the number 61526 shall cover the following topics: 1. Combination of all the mentioned standards; 2. Maintenance of the essential requirements of the former standards; 3. Inclusion of the determination of the uncertainty of measurement for the measured dose equivalent value according to the ''Guide to the Expression of Uncertainty in Measurement''; 4. Consideration of all the relevant ISO-standards for reference radiation fields ...
Neutron radiography and neutron radioscopy are rapidly becoming the valuable tools for nondestructive testing and basic research. The Phoenix Memorial Laboratory has developed a neutron facility capable of both film neutron radiography and real time neutron radioscopy, and has used this facility to study several phenomena of interest to the researchers in many areas. Neutrons can be used for imaging the phenomena that X-ray cannot image, such as the presence, absence or movement of hydrogenous materials inside metals such as aluminum or steel. There are three basic methods for obtaining images using neutrons: high resolution film neutron radiography, real-time neutron radioscopy and transfer film neutron radiography. The neutron radiography facility at ...
To evaluate whether children with and without autism could exhibit (a) functional equivalence in the course of yoked repeated-reversal training and (b) reversal learning set, 6 children, in...Full Text Available
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...
The authors have developed a high-sensitivity real-time neutron radiography (NR) system by the use of the low power reactor of Kinki University. The system was constructed with a high efficiency neutron-photon converter, an image intensifier and a SIT TELEVISION camera. Some digital image processing techniques were applied for improving the quality of the real-time neutron images. By the use of this system, dynamic neutron imaging was performed successfully under the condition of a weak neutron field that was about two orders of magnitude lower than that of the standard NR system. The neutron flux, calculated from the fluctuation of the neutron response of the images, was nearly equal to the value measured by the foil activation method. From this fact, the efficiency for the neutron detection of the imaging system was ...
... Propulsive efficiency is equivalent to the product of thrust efficiency and the hull/waterjet interaction efficiency. ... t'waterjet pump Ktorque repeated ...
Presented are results of a test of a method for measuring neutron fluences using detectors with fissionable nuclides. The investigations show the soundness of of using neutron-activation detectors of the type Am for mesurements in nuclear installations for values of thermal-neutron fluence of from 10/sup 13/ to 10/sup 20/ neutrons/cm/sup 2/ with exposure for up to several months. The proposed method can be used for prolonged measurements in strong fields of both thermal and fast neutrons.
This report discusses the following topics: Prompt fission neutron energy spectra for {sup 235}U and {sup 239}Pu; Two-parameter measurement of nuclear lifetimes; ``Black`` neutron detector; Data reduction techniques for neutron scattering experiments; Inelastic neutron scattering studies in {sup 197}Au; Elastic and inelastic scattering studies in {sup 239}Pu; and neutron induced defects in silicon dioxide MOS structures.
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Following a recent refurbishment of the NPL Thermal Neutron Facility, the spectrum of the epithermal and fast neutron component of the beam produced by the thermal column of this facility was measured over the energy range from thermal to 20 MeV using a Bonner sphere spectrometry system. The effect of the presence of epithermal and fast neutrons on the measured response of commonly-used thermal neutron dosemeters was calculated. (author)
Constructive and combinatorial relationships between order-isomorphisms and order-equivalence classes within the generalized genetic code are presented, not only for the biologically relevant groups of order 4, but also for finite groups of arbitrary order. The main result is the derivation of the number (and types) or order-equivalence classes for a group of order n. Finally, an extension of this work to all biologically admissible alternative codes is discussed.
To help confirm correct functioning of an epithermal neutron sonde, we measured tightly bonded water content of selected Nevada Test Site (NTS) drill holes. Tuff and alluvium samples were dried overnight at 105/sup 0/C. The samples were then heated for 45 min in a split tube furnace at 700/sup 0/C. The water that came off due to this heating was collected and the amount recorded. The error in this procedure is +- 0.59 wt %. Total water can be calculated for samples from analyses of free and tightly bonded water contents. The maximum error in this calculation is equivalent to the error in determining the more tightly bonded water. Average total water content values have been assigned to geologic units. These values, in weight fraction, are alluvium 0.14 +- .05 and tuff 0.19 +- .04. Further division of the tuff gives values of Rainier Mesa 0.15 +- .01, Paintbrush 0.18 +- .03, Tunnel Beds 0.20 +- .04, and Grouse Canyon 0.29 +- .02. Statistically ...
The US DOE manages the safe storage of approximately 650,000 tons of depleted uranium hexafluoride remaining from the Cold War. This slightly radioactive, but chemically active, material is contained in more than 46,000 steel storage cylinders that are located at Oak Ridge, Tennessee; Paducah, Kentucky; and Portsmouth, Ohio. Some of the cylinders are more than 40 years old, and approximately 17,500 are considered problem cylinders because their physical integrity is questionable. These cylinders require an annual visual inspection. The remainder of the 46,000-plus cylinders must be visually inspected every four years. Currently, the cylinder inspection program is extremely labor intensive. Because these inspections are accomplished visually, they may not be effective in the early detection of leaking cylinders. The inspection program requires approximately 12--14 full-time-equivalent (FTE) employees. At the cost of approximately $125K per FTE, this translates to ...
One of the limiting contributors to the heat load constraint for a long term spent fuel repository is the decay of americium-241. A possible option to reduce the heat load produced by Am-241 is to eliminate it via transmutation in a light water reactor thermal neutron environment, in particular, by taking advantage of the large thermal fission cross section of Am-242 and Am-242m. In this study we employ lattice loading optimization techniques to define the loadings and arrangements of fuel pins with blended americium and uranium oxide in boiling water reactor bundles, specifically, by defining the incineration of pre-loaded americium as an objective function to maximize americium transmutation. Subsequently, the viability of these optimized lattices is tested by assembling them into bundles with Am-spiked fuel pins and by loading these bundles into realistic three-dimensional BWR core-wide simulations that model multiple reload cycles and observe standard ...
A neutron imaging system (NIS) has been recently installed at the University of Texas TRIGA reactor facility. The imaging system establishes new capabilities for beam diagnostics at the Texas Cold Neutron Source (TCNS) for real-time neutron radiography (RTNR) and for neutron computed tomography (NCT) research. The NIS will also be used for other research projects. The system consists of two subsystems as follows: (1) Thomson 9-in. neutron image intensifier (NII) tube sensitive to cold, thermal, and epithermal neutrons, (2) image-processing unit consisting of vidicon camera, two high-resolution monitors, image enhancement and measurement processor, and video printer. The NIS is installed at the cold neutron beam of the TCNS for testing and cold neutron beam diagnostics.
In this paper, a time-domain equivalent circuit method is applied to solve dispersion of coupled-cavity travelling-wave tube (CCTWT). First, the time-domain circuit equations of CCTWT coupled-cavity chain are deduced from the equivalent circuit model. Then, the equations are solved numerically by fourth-order Runge-Kutta method and a program CTTDCP is developed using MATLAB. Last, a L-band CCTWT is calculated using CTTDCP and the cavity pass-band of this tube is computed to be 1.08-1.48 GHz, which is consistent with the experimental results and the simulation results of electromagnetic code and demonstrates the validity of the time-domain equivalent circuit method. In addition, a new design method which uses the equivalent circuit method and electromagnetic simulation together to optimize the cold cavity characteristics of CCTWT is proposed. (authors)
By applying the linear-dose effect relation, the weighting factors for total risks recommended by IRCP can be transformed to weighting factors for somatic effects. Another weighting factor Msub(s) has to be used which takes into account the dependence of the latent period for occurrence of malignant disease and the variation of the incidence with time. On this basis a somatically significant dose equivalent can be defined as 'the dose equivalent which if received by every member of the population, would be expected to produce the same total somatic injury to the population as does the actual dose equivalent received by the various individuals', and an approximation has been derived for this. Tables are presented of the somatic effective dose equivalents calculated for different x-ray examinations for various organs and tissues. The S.E.D. equivalents have also been calculated for ...
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented.
Optimal neutron energy for boron neutron capture therapy (BNCT) has been studied. Epithermal neutron is superior to thermal neutrons in treating deep-seated tumors. Design of the epithermal neutron column for BNCT has been performed by using a two-dimensional transport calculation code. Aluminum and heavy water are used as moderation materials. A thermal neutron column is also designed using heavy water as thermalization material. The configuration of the facility for treatment and research of BNCT and also for basic radio-biological studies of neutrons has been presented. (author).
Neutron-induced soft error rates (SER`s) of subhalf-micron CMOS SRAM and Latch circuits were studied both experimentally and analytically to investigate cosmic ray neutron-induced soft errors (SE`s). Because the neutron beam used in the measurement has an energy spectrum similar to that of sea-level atmospheric neutrons, the SER data corresponds to those induced by cosmic ray neutrons. The {alpha}-particle induced SER`s were also measured for comparison with the neutron-induced SER`s. Neutron-induced SE`s occurred in both circuits. On the other hand, {alpha}-induced SE`s occurred in SRAM, but not in the Latch circuit. The measured SER`s agreed with simulated results. The authors discussed the significance of how cosmic ray neutrons affects CMOS circuits at ground level.
Gamma-ray spectrometric analysis was employed to determine the nuclides formed in thorium by neutron irradiation. Thorium sample was irradiated by neutron from a pure thermal neutron field, neutron field of Cd ratio of about 4, and epithermal neutron field, respectively. The former irradiation was carried out in a thermal neutron column provided for medical uses of neutrons, and the latters were done in the F-ring position of TRIGA II research reactor of Musashi Institute of Technology. The gamma-ray spectra were obtained and analyzed by employing a fully automatic gamma-ray analysis system named ''GAMA: giant frog:-SYSTEM'' developped by Musashi Institute of Technology. The formation of Pa-233 (U-233) was discussed quantitatively with respect to the difference of the neutron field. (author).
The detection efficiency of a lithium glass detector was calculated using MCNP code, and the calculation was compared with the published results in Pulsed Sphere Plan. A lithium glass detector of our own was made, and its neutron efficiency was calculated. The calculated neutron efficiency was verified with both pulsed and steady DD neutrons. Characteristics of Neutron response of "6Li detector was discussed. (authors)
This paper reviews the effects of neutron irradiation on thermal and mechanical properties and bulk tritium retention of armour materials (beryllium, tungsten and carbon). For each material, the main properties affected by neutron irradiation are described and the specific tests of neutron irradiated armour materials under thermal shock and disruption conditions are summarized. Based on current knowledge, the expected thermal and structural performance of neutron irradiated armour materials in the ITER plasma facing components are analysed.
A thermal neutron imaging facility for computed tomography and real-time neutron radiography is being developed at the University of Texas at Austin. The TRIGA reactor is a graphite-reflected Mark It pool-type research reactor. The neutron imaging facility will use beam port, which is at one end of a through part. Monte Carlo calculations were used to design the neutron collimator for this facility.
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A high-purity, intense, fast-neutron source has been developed at our laboratory. We describe two inexpensive, straightforward methods of determining the total number of neutrons produced and we review precautions to be taken in applying these methods. (orig.).
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...
Neutron radiography is a non-destructive test method to examine a material by using the dependency of neutron attenuation on the nuclear characteristics of the atoms composing the object material. There are two categories of neutron radiography; static neutron radiography and dynamic neutron radiography. The static neutron radiography is a technique to observe a standing object by using a camera or a film cassette. The dynamic neutron radiography(DNR) is a technique to observe a moving object usually by using a camera. Depending on the camera frame rate, the dynamic neutron radiography is categorized into the real time neutron radiography(RTNR) and the high speed neutron radiography(HSNR). The frame rate for RTNR is 30 frames/s and that for HSNR is usually more that 500 ...
Effects associated with the temperature dependence of the level density parameter, a(T), are investigated in connection with neutron evaporation processes. Different approximations, for this temperature dependence, are compared for the case of neutron emission from the compound nucleus /sup 209/Pb.
It is shown that a natural consequence of the binary pulsar's evolution is a neutron star collision. Such a collision is expected to eject neutron-rich matter of an r-process character. Taking reasonable estimates for the number of such events over the history of the galaxy, it may be that they account for all of the r-process nuclei.
A black neutron detector of novel design has been constructed and tested as a neutron flux monitor. The neutron time-of-flight (TOF) technique was used to measure the zero degree neutron spectrum from a subnanosecond pulsed proton beam on a thick metallic lithium target. We describe the detector, discuss the shielding arrangement and electronics, determine the low-energy cut-off. We calculate the efficiency, show spectra and compare measured zero degree differential cross-section of the {sup 7}Li(p, n{sub 0}){sup 7}Be reaction with recommended published cross-sections. (orig.).
Because of limitation on neutron-incident data, it is difficult to obtain global optical model potential for neutrons. In contrast, there are some global optical model potentials for proton in detail. It is interesting to convert the proton-incident global optical potentials into neutron-incident ones. In this study we introduce (N-Z)/A dependent symmetry potential terms into the global proton-incident optical potentials, and then obtain neutron-incident ones. The neutron potentials reproduce total cross sections in an acceptable degree. However, a comparison with potentials proposed by other authors brings about a confused situation in the sign of the symmetry terms. (author).
A method and apparatus for nuclear borehole logging, and in particular, neutron porosity logging, uses a neutron source, and a pair of spaced lithium detectors, preferably Li"6I crystal or Li"6 doped glass, to detect neutrons emitted from a borehole formation being logged. The spectrum developed by the lithium detectors is processed to remove the gamma ray background radiation and the hydrogen absorption peak, thus allowing a more accurate neutron count. A Gaussian curve is fitted to the neutron peak of the spectrum, the curve eliminating the hydrogen absorption peak. The area under this Gaussian curve represents the neutron count. (author).
The introduction prior to series of papers on the application of neutrons for materials science (MS) in this issue starts with a brief summary of neutron scattering research history in Japan; from the individual activity by Motoharu Kimura at RIKEN early around 1940s to those at present era of world leading neutron science facilities of both JRR3 research reactor and JPARC of the largest proton Accelerator complex in Tokai. Then physical properties of low energy neutrons applied to MS as well as such neutron sources are also reviewed (http://www.jstage.jst.go.jp/browse/jvsj2). (author)
Determination of thermal to fast neutron flux ratio (ffast) and fast neutron flux (phi-fast) is required for fast neutron reactions, fast neutron activation analysis, and for correcting interference reactions. The ffast and subsequently phi-fast were determined using the absolute method. The ffast ranged from 48 to 155, and the phi-fast was found in the range 1.03x1010-4.89x1010 n cm-2 s-1. These values indicate an acceptable conformity and applicable for installation of the fast neutron facility at the MNA research reactor.
Thermal neutron beam from the TNRF of JRR-3M was utilized for detection of mice lung cancer in vivo. Both the static and real-time neutron imaging were tried. Very strong thermal neutron beam is necessary to detect lung cancers because small changes are hidden by the very large attenuation of thermal neutron beam by the hydrogens in the tissues. The detection was successfully performed. Especially, the Super Eye of Hamamatsu Photonics contributed very effectively. Bone marrows and cartilages were also shown clearly. If an efficient and compact neutron source will become available in future, this method will grow up as a powerful tool for biomedical application. (author).
A neutron collimator system is being designed as part of a neutron imaging facility for computed tomography and real-time neutron radiography research at the through beam port of the University of Texas TRIGA reactor. Lack of sufficient information about collimator systems in a through port from the literature necessitated the use of Monte Carlo calculations using the MCNP code 3 to search for optimal design configuration and materials that maximize the thermal neutron intensity at the image plane while minimizing the fast neutrons and gamma radiation.
There are several equivalent descriptions for constant B-field background of open string. The background can be interpreted as constant B-field as well as constant gauge field strength or infinitely many D-branes with non-commuting Chan-Paton matrices. In this article, the equivalence of these open string theories is studied in Witten's cubic open string field theory. Through the map between these equivalent descriptions, both algebra of non-commutative coordinates as well as Chan-Paton matrix algebra are identified with subalgebras of open string field algebra. (author)
The dosimetry for radiotherapy involving neutrons is very complicated, owing to the complexity of secondary radiation components, whose contributions to the total absorbed dose have to be discriminated, owing to the different radiobiological effects. In order to separate thermal neutrons and photons, LiF dosimeters are mostly utilized. containing different percentage of Li, like as TLD-700, TLD-100 and TLD-600, but many problems arise. In the response of TLD-700 exposed to neutron-gamma mixed fields with high neutron flux, the contribution of thermal neutrons to the Tl emission is high. Moreover. TLD-100 and TLD-600 may undergo radiation damage, and great care has to be taken in order to obtain reliable results. Other TLDs showing lower sensitivity to neutrons are proposed and experimented for such high-flux neutron fields. The faced ...
A prediction of delayed neutron yields for actinides which are important in the nuclear energy field is given. The prediction is based on a correlation related to a suggested cluster structure of the nucleus. (author).
Neutron yield from the "6","7Li + d reaction has been investigated. The results obtained are compared with the published data with some theoretical models.
The delayed neutrons from neutron-induced fission in /sup 232/U, /sup 237/Np, /sup 238/Pu, /sup 241/Am, /sup 242/Am/sup m/, /sup 245/Cm, and /sup 249/Cf were studied for the first time; those from /sup 232/Th, /sup 233/U, /sup 235/U, /sup 238/U, /sup 239/Pu, /sup 241/Pu, and /sup 242/Pu were measured again. The data were used to develop an expression for the prediction of the absolute delayed neutron yield, and the prediction of delayed neutron emission with time. This approach accurately predicts observed delayed neutron yields and decay characteristics. A fission product yield model was used in conjunction with delayed neutron emission probability to analytically predict delayed neutron characteristics. The results of this analysis are in excellent agreement with experimental values.
The measurements of the total delayed neutron yield from fast neutron induced fission of sup 2 sup 3 sup 8 U were made. The experimental method based on the periodic irradiation of the fissionable sample by neutrons from a suitable nuclear reaction had been employed. The preliminary results on the energy dependence of the total delayed neutron yield from fission of sup 2 sup 3 sup 8 U are obtained. According to the comparison of experimental data with our prediction based on correlation properties of delayed neutron characteristics, it is concluded that the value of the total delayed neutron yield near the threshold of (n,f) reaction is not a constant.
It is shown numerically that on a time scale of order 1 msec a neutron star with pion condensation will undergo separation into a core and an envelope with a sharp interface. The envelope will not, however, be ejected.
... hypersonic aerodynamic force, or the space-equivalent region. Some of these experiments change the X-15 from a research airplane to a kind of space probe, ...
COATINGS FOR THE METAL-SEMICONDUCTOR SOLAR CELLS 3S GIVEN. THIS METHOD UTILIZES THE MEASURED EQUIVALENT INDEX OF. REFRACTION OBTAINED FROM ELLIPSOMETRY ...
One of the challenges facing engineers is developing newer, safer detonators that are equivalent to devices currently in use. There is no clear consensus on an exact method for drawing equivalence of detonators. This paper summarizes our current efforts to develop diagnostics addressing various aspects of detonator design to better quantify and prove equivalency. We consider various optical techniques to quantify the output pressure and output wave shape. The development of a unique interpretation of streak camera breakouts, known as the apparent center of initiation, will be discussed as a metric for detonation wave shape. Specific examples apply these techniques to the comparison of a new laser-driven detonator with an existing exploding bridgewire (EBW) detonator. Successes and short-comings of the techniques will be discussed.
High-spin states in the mirror pair nuclei {sup 49}Cr and {sup 49}Mn and their cross-conjugate partners, the mirror pair {sup 47}V and {sup 47}Cr have been investigated using experimental {gamma}-ray spectroscopic techniques. The combination of high-efficiency EUROBALL cluster Germanium detectors and clean exit-channel gating afforded by a 31-element silicon ball used in conjunction with a 15-detector neutron wall allowed a revision and extension to the energy level schemes of all four nuclei up to J{sup {pi}}=31{sup -}/2. The difference in excitation energy between states of equivalent spin in the parent nucleus and its analogue partner have thus been established for both mirror pairs up to the f{sub 7/2}-shell band terminating state for the first time. This difference is assumed to be due almost entirely to the Coulomb effect and is therefore called the Coulomb energy difference (CED). The variation in the CED with spin has been interpreted ...
The radionuclide characteristics of light-water-reactor (LWR) spent fuel play key roles in the design and licensing activities for radioactive waste transportation systems, interim storage facilities, and the final repository site. Several areas of analysis require detailed information concerning the time-dependent behavior of radioactive nuclides including (1) neutron/gamma-ray sources for shielding studies, (2) fissile/absorber concentrations for criticality safety determinations, (3) residual decay heat predictions for thermal considerations, and (4) curie and/or radiological toxicity levels for materials assumed to be released into the ground/environment after long periods of time. The crucial nature of the radionuclide predictions over both short and long periods of time has resulted in an increased emphasis on thorough validation for radionuclide generation/depletion codes. Current radionuclide generation/depletion codes have the capability to follow the ...
Recent developments in design and production of thermal neutron detectors based on a crystalline Si diode coupled to a Gd converter are reviewed. The most significant results of neutron test measurements carried out on prototype systems and pointing out the performances of the device are reported. Progress through various detection schemes and technological solutions for the production of a real time neutron counter for routine operation are outlined.
Neutron Science Project was started at Japan Atomic Energy Research Institute since 1996 for promoting futuristic basic science and nuclear technology utilizing neutrons. For this purpose, research and developments of intense proton accelerator and spallation neutron target were initiated. The present paper describes the current status of such research and developments. (author)
The characteristics of real-time neutron radiography are described briefly in this paper, and the acquirement of neutron flux, the selection of convertor and the structure of the twilight imaging system and the image-sampling and image-processing system in SPRR-300 reactor are also analyzed detailedly. The experimental result of real-time neutron radiograph is too analyzed in this paper
We describe the continued development of a portable, real-time neutron spectrometer. The spectrometer is composed of two distinct detector systems: a Helium 3 gas filled proportional counter for the lower neutron energy interval between 20 KeV and 2 MeV and a bulk silicon solid state detector for the higher energy interval between 2 MeV and 500 MeV. Modeling and experimental results with mono-energetic neutron beams are reported.
Isospin-breaking effects in the baryonic sector are studied in the framework of a medium-modified Skyrme model. The neutron-proton mass difference in infinite, asymmetric nuclear matter is discussed. In order to describe the influence of the nuclear environment on the skyrmions, we include energy-dependent charged and neutral pion optical potentials in the s- and p-wave channels. The present approach predicts that the neutron-proton mass difference is mainly dictated by its strong part and that it strongly decreases in neutron matter. (orig.)
A 68 MeV neutron transmission experiment on iron has been analyzed with MCNPX using the Los Alamos LA150 neutron data library, the ECN/BRC 150 MeV neutron data library and with the intranuclear cascade code LAHET. The clear improvement of using the data libraries is confirmed. Also, other materials present in LA150 have been checked using the same MCNPX set-up. 10 refs.
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of {sup 6}Li and {sup 7}Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of {sup 6}Li and {sup 7}Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
In 1998, research began at Idaho National Engineering and Environmental Laboratory to investigate the application of "6Li and "7Li isotopes to the measurement of neutron and gamma radiation. Various size pairs of "6Li and "7Li based detectors were exposed to mixed neutron and gamma radiation. Experiments demonstrated that these detectors could be used to measure low level neutron radiation in the presence of high level gamma radiation. (author)
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of ...
The field of neutron imaging has a broad scope of applications and has played a pivotal role in visualizing and quantifying hydrogenous masses in metallic matrices. The field continues to expand into new applications with the installation of new neutron imaging facilities. In this scope, a neutron imaging facility for computed tomography and real-time neutron radiography is currently being developed around 2.0 MW TRIGA MARK-II Reactor at Maamora Nuclear Research Centre in Morocco (CENM). The neutron imaging facility consists of a neutron collimator, a real-time neutron imaging system and imaging process systems. In order to reduce the gamma-ray content in the neutron beam, the reactor tangential channel was selected. For power of 250 kW, the corresponding thermal neutron flux measured at the inlet of ...
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed and built at the University of Texas TRIGA reactor. Herein the authors present preliminary results of radiography and tomography test experiments. These preliminary results showed that the beam is of high quality and is suitable for radiography and tomography applications. A more detailed description of the facility is given elsewhere
The Albedo Theory was applied in order to develop an one-group algorithm for coupled neutron-gamma shielding calculations. The configuration analyzed consists of multilayered plane systems, where a incident neutron current generates gamma radiation through neutron-gamma reactions. The results obtained by Albedo Method and ANISN code have shown excellent agreement. (author)
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
A multi-group neutron-gamma cross-section library in DTF-IV format is supplemented with electron production matrix to generate a coupled neutron-gamma-electron library. This is realized by estimating the contributions from Compton scattering, pair production and photoelectric effect to the electron production cross-sections. A novel application of this new library, which involves transport of neutrons, gammas and electrons, for estimating the Compton current due to a pulse of radiation in air is discussed.
Using the boson-fermion equivalence in 2-d conformal field theory and the boson-boson equivalence of the superconformal bosonic ghost fields of the string theory, the authors construct a level {Kappa} = +1 representation of the affine superalgebra OSp(M*N)/sup 1/ in terms of vertex operators.
In the present study an estimate is made of the malignancy significant dose from external beam radiotherapy in New Zealand utilizing data obtained in a survey conducted in 1975. This survey had been designed to assess genetically significant dose. A weighted effective dose equivalent is derived from the malignancy significant dose for direct comparison with mean per capita effective dose equivalents arising from other sources of radiation. 14 refs., 1 fig., 8 tabs.
This report revises estimates of population exposure to external natural background made by D. T. Oakley in 1972. The revisions include more recent estimates of dose equivalents from cosmic rays, use of 1970 U.S. census data, and corrections for building shielding and for self-shielding in the body. The dose equivalents calculated are those from cosmic rays and terrestrial radiation, and do not include doses from natural radioactive materials in the body.
Concentrations of 226Ra, 232Th, and 40K measured in bauxite waste, local building materials, and soils are presented and used in model equations to estimate the effective gamma dose-equivalent increments over background in the center of a standard-sized room in a prototype house. Calculated and measured values compare reasonably well.
Depth dose distributions for protons in the energy range from 2 to 600 MeV have been calculated by Monte Carlo and analytical methods. The dependence on energy of Maximum Dose Equivalent (MDE), quality factor and isotropic factor recommended for practical use are presented. The problems connected with regulation of maximum permissible proton fluxes are discussed. (author).
The title refers to the area of research which studies infinite groups using measure-theoretic tools, and studies the restrictions that group structure imposes on ergodic theory of their actions. The paper is a survey of recent developments focused on the notion of Measure Equivalence between groups, and Orbit Equivalence between group actions. We discuss known invariants and classification results (rigidity) in both areas.
To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a heavy water reactor (HWR) has preference above irradiation in a PWR or in a high temperature gas-cooled reactor (HTGR). (authors) 4 refs.
To get a considerable reduction of the radiotoxicity due to americium, a thermal neutron fluence of 2.10{sup 22} cm{sup -2} or a fast neutron fluence of 2.10{sup 24} cm{sup -2} is required. Irradiation in a thermal neutron flux leads to lower masses of {sup 234}U and precursors and of {sup 237}Np and precursors, but to higher curium masses and much higher neutron emission rates than irradiation in a fast neutron flux. Therefore, irradiation in a fast neutron flux has preference when multiple recycling is adopted. When once-through burning is applied, irradiation in a thermal neutron flux can be applied. Then irradiation in a HWR has preference above irradiation in a PWR or in a HTGR. (orig.).
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design. PMID:15246420
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, is potentially identifiable with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
An explanation is given of what a loop heat pipe (LHP) is, and how it works. It is then shown that neutron imaging (both real time neutron radioscopy and single exposure neutron radiography) is an effective experimental tool for the study of LHPs. Specifically, neutron imaging has helped to identify and correct a cooling water distribution problem in the condenser, and has enabled visualization of two-phase flow (liquid and vapor) in various components of the LHP. In addition, partial wick dry-out, a phenomenon of great importance in the effective operation of LHPs, has been identified with neutron imaging. It is anticipated that neutron radioscopy and radiography will greatly contribute to our understanding of LHP operation, and will lead to improvement of LHP modeling and design.
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
A novel system for real-time radiation monitoring in reactor or accelerator facilities has been studied using an imaging plate. The authors made a feasibility study on a new neutron detection system using both photostimulated luminescence (PSL) and prompt luminescence (PL) generated in a neutron imaging plate (NIP) when the NIP is irradiated by neutrons. A readout system consisting of a semiconductor laser and a photomultiplier tube was fabricated for the purpose. It was confirmed that the system can measure both PSL and PL, where Am-Li was used as a neutron source. It may be possible to establish a new wide-range neutron monitoring system using the developed system as a PL mode normally, and as a PSL mode in case of intense neutron dose that cannot be measured in a PL mode because of saturation of the detection system. (author)
The neutron radiography facility was installed at the tangential beam port of the 3 MW TRIGA MARK-II research reactor. In the facility only direct film neutron radiography method is being used. The project involves development of electronic imaging system for real time neutron radiography in the existing facility with the aim of utilizing it for research and industrial applications. In establishing the electronic imaging system for real time neutron radiography the improvements of existing facility were almost done during this period. In parallel, the former facility was used for the research: (a) A study of wood and wood plastic composites with and without additive by using film neutron radiography and (b) A study of jute reinforced polymer composites by using film neutron radiography technique. (author)
The registration of secondary cosmic ray neutrons is a convenient tool for the investigation of primary cosmic ray variations and for meteorological effects as well. At present a large network of neutron monitors exists, aiming at studies of cosmic ray variations which are related to interplanetary conditions and geomagnetic activity. At the same time cosmic ray variations may be related to some atmospheric processes. In this connection, using the data from two neutron monitors (a standard and a lead free one), a gamma detector from Moscow station and lead free neutron monitor at BEO Moussala, we studied the correlations between rain flows and neutron flux. In this study we used daily averages on the basis of 10 min data for the neutron flux, corrected for barometric pressure and data from local meteo-stations. The preliminary analysis indicates a correlation ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible ...
The University of Virginia's real-time neutron radiography facility was characterized by measurement of the total neutron flux, gold/cadmium ratio, neutron/gamma ratio, and the effective collimar length-to-aperture diameter (L/D) ratio. The real-time neutron imaging system and collimator were further characterized by measuring the modulation transfer function (MTF) of the system. The collimator effectiveness was measured by using the MTF to determine the ''unparallelism'' of the neutron beam. The computer-based image processing system allowed rapid calculation of the MTF and the collimator effectiveness. The results of these measurements, using no collimator and a simple tube collimator, demonstrated the method's ability to determine the effective L/D ratio. The MTF measurement scheme provided a fast, reliable, and reproducible means of monitoring any changes in the real-time ...
By using this doping method, silicon semiconductors with extremely uniform dopant distributions can be produced, and this is the dominant advantage of NTD compared with a conventional chemical doping. Good uniformity of a dopant concentration is usually required for high power applications such as thyristor (SCR), IGBT, IGCT and GTO and for special sensors. Achieving an accurate neutron fluence corresponding to a target resistivity as well as a uniform irradiation is the prime target of a neutron irradiation for NTD. Generally, in order to reach an accurate neutron fluence, a real time neutron flux is monitored by a neutron detector such as a Self-powered Neutron Detector(SPND). And, after an irradiation, the total irradiation fluence is confirmed by measuring the absolute activity of a neutron activation sample that has been irradiated with ...
Neutron semiconductor detectors for neutron counting and neutron radiography have an increasing importance. Simple silicon neutron detectors are combination of a planar diode with a layer of an appropriate neutron converter such as 6LiF. These devices have limited detection efficiency of not more than 5%. The detection efficiency can be increased by creating a 3D microstructure of dips, trenches or pores in the detector and filling it with a neutron converter. The first results related to the development of such devices are presented. Silicon detectors were fabricated with pyramidal dips on the surface covered with 6LiF and then irradiated by thermal neutrons. Pulse height spectra of the energy deposited in the sensitive volume were compared with simulations. The detection efficiency of these devices was about 6.3%. Samples with different ...
The equivalent doses of K-feldspar grains in a range of grain sizes from 90 to 250#mu#m diameter were measured using a single-aliquot regenerative-dose protocol for the infrared stimulated luminescence (IRSL) signals for two samples of desert sand. The equivalent doses for each sample were compared with that for the 125-150#mu#m grains of quartz from the same samples. The results suggested that the K-feldspar equivalent doses were underestimated because of anomalous fading. Measurements of the decay of the IRSL signals following laboratory irradiation for these two samples, and an additional one from a previously published isochron study, showed anomalous fading during the period of laboratory storage. The decay rate was about 3% per decade for all samples and was independent of the grain size used. Using plots of equivalent doses for K-feldspars as a function of their calculated internal dose rate, and ...
An equation of state of neutron star matter with strange baryons has been obtained. The effects of the strength of hyperon-hyperon interactions on the equations of state constructed for the chosen parameter sets have been analysed. Numerous neutron star models show that the appearance of hyperons is connected with the increasing density in neutron star interiors. The performed calculations have indicated that a change of the hyperon-hyperon coupling constants affects the chemical composition of a neutron star. The obtained numerical hyperon star models exclude a large population of strange baryons in the star interior.
The applications of neutron reflectometry to study dynamic phenomena at surface and interfaces have been restricted so far. This was mainly due to the low intensity of neutron sources, but now high-intensity spallation neutron sources are under construction in Japan (J-PARC) and US (SNS). We are planning to install a spin-echo option on the J-PARC neutron reflectometer with horizontal sample geometry for studies of dynamics of surfaces and interfaces. This option is based on the resonance spin-echo method and aimed at dynamics up to hundreds of nanoseconds. In this contribution, the plan and status of development are introduced together with the principle and characteristics of this option.
The polarized triple-axis spectrometer TASP at SINQ has been optimized for measuring magnetic cross sections in condensed matter. The neutrons are polarized or analyzed either by means of benders or Heusler monochromators. The beam divergence, i.e. the intensity, and the spectral range of the neutrons is rather large because of the supermirror coatings of the feeding neutron guide. The intensity can be further increased at the sample position by means of a focussing monochromator and a focussing anti-trumpet. The end position of TASP allows the tailoring of the neutron beam already before the monochromator and to scatter neutrons over very wide ranges of angles. (author) 6 figs., 1 tab., 8 refs.
A helium-3 proportional detector was equipped with the experiment of Liaw-type electrolytic cell contained eutectic LiCl-KCl molten salt saturated by LiD electrolytic to collect the informations of the rate and the energy distribution of possible neutron produced during the electrolysis processes. For long time monitoring, the significant reproducible neutron bursts appeared at several runs of cells during electrolytic processing. The neutron counting rate increased about a factor of two above the level of the background measurement. The pulse height signals were verified of neutron energy ranging from thermal up to 350 keV. (author).
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
Measurements were made of the cross section for /sup 242/Am/sup m/ fission induced by neutrons in the energy range 0.04< or =E/sub n/< or =4.52 MeV as well as by neutrons with E/sub n/roughly-equal14.8 MeV. An electrostatic generator and a low-voltage accelerating tube were used to generate the quasimonochromatic neutrons. Measurements in the low-energy region were made by using the time-of-flight technique in neutrons from a nuclear explosion. Results of the measurements are compared with previously published data.
A Si array neutron detector is proposed based on commercial CCD and CMOS sensor technology coupled with a thin film neutron conversion coating. System sensitivity is estimated for a baseline device containing a single array and various schemes to increase detection probability by simple area scaling and stacking are discussed. Some possible use scenarios are discussed involving static and moving sources. Likely neutron source fluxes for weapons grade and commercial grade nuclear material are estimated along with expected intensities of cosmic background neutrons which would establish a noise floor to detection limits.
This paper analyzes fission neutron multiplicity for the /sup 242m/Am(n,f) reaction. The fission neutron multiplicity, v bar, of /sup 242m/Am(n,f) was measured relative to that of /sup 235/U(n,f) using the neutron time-of-flight facility at the Lawrence Livermore National Laboratory 100-MeV electron Linac. A comparison of the measured energy dependence of v-bar is made with semi-empirical models of neutron emission from the actinides. 22 refs.
A method of detecting explosives in a vehicle includes providing a first rack on one side of the vehicle, the rack including a neutron generator and a plurality of gamma ray detectors; providing a second rack on another side of the vehicle, the second rack including a neutron generator and a plurality of gamma ray detectors; providing a control system, remote from the first and second racks, coupled to the neutron generators and gamma ray detectors; using the control system, causing the neutron generators to generate neutrons; and performing gamma ray spectroscopy on spectra read by the gamma ray detectors to look for a signature indicative of presence of an explosive. Various apparatus and other methods are also provided.
Inelastically scattered neutron spectra and angular distributions measured for a number of nuclei at the 9.1 and 14.4 MeV incident neutron energies are fitted well as a sum of neutron evaporation spectrum and the direct interaction part. For the last one the practical scheme of parametrization based on direct interaction theory is presented. The relative contribution of direct interactions in double differential cross sections and parameters of neutron evaporation spectra have been evaluated. All results have a simple physical interpretation and may be useful at interpolating of data in a wide energy interval.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter.
Recently the real-time neutron radiography system of the Kyoto University Reactor (KUR) has been developed and practically applied to penetrating the side plates of the MTR type reactor fuels and investigation of moving objects. In this paper an application of the KUR neutron TV system to neutron computed tomography (NCT) is described. By using the NTV system, projection data can be acquired in a single measurement and simultaneously the projection image can be observed on a CRT monitor. The Fourier-convolution technique is used to produce the reconstructed image and its image has a good enough quality for revealing water in a small hole of 1.5 mm in diameter. (orig.).
As part of a general study of personnel neutron dosimetry systems, three British and two German TL albedo dosimeters were compared. They range from simple albedo devices to multi-element devices which detect combinations of incident and albedo neutrons. They were exposed to beams of mono-energetic neutrons, a thermal neutron column and a "2"5"2Cf source. The variation in response with neutron energy above 0.1MeV was similar for all dosimeters. The resuls show that in general multi-component dosimeters fo not provide enough information to deduce the effective energy of incident neutrons. The choice of single or multi-element dosimeters for particular types of environment is discussed. The Harvey dosimeter has the most acceptable thermal neutron response of the simpler devices. For ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
A system for real-time neutron radiography of moving objects is described. It comprise a source adapted to generate a continuous uninterrupted series of neutron pulses. Each pulse has a predetermined peak power and duration compatible with the framing times of a real-time video imaging system. A transporter moves an object to be examined to bring sequentially position selected portions of the object in the path of the pulses. Where the object itself has moving components, pulses are sequentially incident on the object. According to any dissimilarities, the object will alter the intensity of the neutrons passing therethrough. In order to record separately the changes in the neutron intensity, for each pulse, an imager is positioned to receive the neutron beam pulses which have been altered by their passage through the object and produce images indicating intensity alterations. A ...
Within the past two and one half years of the project ``Surface Physics With Cold and Thermal Neutron Reflectometry`` a new thermal neutron reflectometer was constructed at the Rhode Island Nuclear Science Center (RINSC). It was used to study various liquid and solid surfaces. Furthermore, neutron reflection experiments were be un at different laboratories in collaboration with Dr. G.P. Fetcher (at Argonne National Laboratory), Dr. T. Russell (IBM Almaden) and Drs. S.K. Satija and A. Karim (at the National Institute for Standards and Technology). The available resources allowed partial construction of an imaging system for ultracold neutrons. It is expected to provide an extremely high resolution in momentum and energy transfer in surface studies using neutron reflectometry. Much of the work reported here was motivated by the possibility of later implementation at the planned ...
When the history of neutrons is considered, three large discoveries are recalled, that is, the discovery of neutrons by Chadwick in 1932, the discovery of the nuclear fission of uranium by Hahn and Strassmann in 1938, and the continuation of chain reaction in nuclear fission by Fermi and others in 1942. In neutron capture reaction, the reaction cross section can become very large. The fields of research, to which neutrons have contributed most as the experimental probe, are neutron activation analysis and neutron diffraction. The development of the prompt gamma ray analyzer at the JRR-3M in Japan Atomic Energy Research Institute is reported. This method eliminates the various defects in ordinary neutron activation analysis. By installing the cold neutron source with hydrogen cooling in the JRR-3M, the new field of ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in the development of real-time neutron radiography systems and neutron-to-light converter screens optimized for real-time application. Two screens currently available at MURR are: (1) a 0.041-cm-thick Gd_2O_2S screen manufactured by 3M Company and (2) a "6KiF-ZnS(Ag) screen (NE 426) manufactured by Nuclear Enterprises. These screens are presently used in conventional film neutron radiography and represent two of the commercially available screens that have demonstrated the greatest resolution and sensitivity. Unfortunately, these screens have severe limitations when used for real-time neutron radiography. In order to isolate and minimize the factors contributing to these limitations, several neutron absorbers and ...
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...
Delayed-neutron (DN) energy spectra following thermal neutron induced fission of /sup 239/Pu as a function of time after fission have been measured, using the beta-neutron time-of-flight (TOF) spectrometer at the University of Lowell. Thermal/epithermal neutrons were produced on the 5.5-MV Van de Graaff accelerator using the /sup 7/Li(p,n)/sup 7/Be reaction. Time spectra over the neutron energy range of 0.01-4.0 MeV were measured for seven different time intervals after fission, each interval containing varying contributions from the six delayed neutrons groups. The DN energy spectra following induced thermal fission of /sup 239/Pu are compared to those resulting from induced thermal fission of /sup 235/U for each of the seven delay time intervals. Decomposition of the measured spectra into six-group DN spectra was accomplished employing an iterative ...
A device for detecting neutrons includes a semi-insulated bulk semiconductor substrate having opposed polished surfaces. A blocking Schottky contact comprised of a series of metals such as Ti, Pt, Au, Ge, Pd, and Ni is formed on a first polished surface of the semiconductor substrate, while a low resistivity ("ohmic") contact comprised of metals such as Au, Ge, and Ni is formed on a second, opposed polished surface of the substrate. In one embodiment, n-type low resistivity pinout contacts comprised of an Au/Ge based eutectic alloy or multi-layered Pd/Ge/Ti/Au are also formed on the opposed polished surfaces and in contact with the Schottky and ohmic contacts. Disposed on the Schottky contact is a neutron reactive film, or coating, for detecting neutrons. The coating is comprised of a hydrogen rich polymer, such as a polyolefin or paraffin; lithium or lithium fluoride; or a heavy metal fissionable material. By varying the ...
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in ...
This article provides a survey of neutron scattering experiments in condensed matter research, which are of interest to chemistry. The theoretical background has been treated in a previous issue. The present article consists of two parts. The first part exhibits the range of experimental possibilities by means of a few selected examples. The starting point is classical neutron diffraction by which the position of atomic nuclei may be determined. Additional information on the spatial distribution in the outer electron shells may be obtained via combined X-ray/neutron-diffraction experiments or via the diffraction of polarized neutrons. Progress in instrumentation, due to the development of more intense sources, has influenced especially the fields of small angle scattering and spectroscopy. The second part features domains of research of current interest, where a combination of several ...
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...
The themal neutron sensitivities of SEI and Toshiba FD-P10-7 radiophotoluminescent silver activated metaphosphate glass dosimeters have been measured and studied theoretically. The graphite thermal neutron column attached to the AEEW reactor NESTOR was utilised as a source of thermal neutrons with minimal fast neutron and gamma-ray contamination. Both the neutron removal and gamma correction measurement techniques were applied and these gave consistent results. It was found that the thermal neutron sensitivity of the Toshiba dosimeters is comparable to the most neutron intensitive thermoluminescent materials available. Because of their larger size and higher silver concentration, however, SEI dosimeters are an order of magnitude more neutron sensitive. The neutron sensitivity of FD-7 glass has not ...
The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and [alpha]-induced SE analysis.
The authors review two types of simulators for the analysis of cosmic ray neutron-induced soft errors (SE's). One of them is the neutron-induced soft error simulator (NISES). A recently proposed nuclear reaction theory forms the foundation for the nuclear reaction database used in NISES. The other simulator, the simplified simulator MBGR, is based on a modified version of the burst generation rate (BGR) model. Both simulators accurately simulate neutron-induced SE rates (SER's). MBGR actually provides an easier and quicker estimation of neutron-induced SER's than NISES. On the other hand, NISES covers more applications; it simulates neutron-induced charge collection, multiple-bit SE, and #alpha#-induced SE analysis
One of the significant factors of neutron radiographic image degradation is scattering blur from the object. A practical method is described to enhance image quality by eliminating the overlapping of scattered thermal neutrons component from the objects in ETRR-2 neutron radiography facility, using aluminum Gd-coated antiscatter grid. The MCNP code was used to determine the optimum grid dimensions that will reduce the scattered thermal neutrons from the object. An experiment was performed to determine the optimum grid height and irradiation time that gives the best image with acceptable geometric unsharpness. Using the MCNP code it was found that 97% of the scattered neutrons were removed by the grid. The wall dimensions and Gd coating are so small that the facility resolution cannot detect the image pattern superposition on the film.
For neutron radiography (NR), photographic techniques have been mainly used for many years. To observe a dynamic event and to test many samples, the real-time neutron radiography (i.e. neutron television - NTV) system has been introduced at the E-2 experimental tube of the Kyoto University Research Reactor (KUR). The NTV system has been practically applied to penetrating the side plates containing boron burnable poison to test MTR type reactor fuel, to investigation of moving objects and to neutron computed tomography (NCT). New approaches using some advanced neutron converters, a high sensitive and resolution TV camera and a high performance image processing system are being undertaken for standard indicators, visualization on air-water two-phase flow, NCT and so on. (author).
Japan Atomic Energy Research Institute (JAERI) is developing the world`s strongest spallation neutron source using high power proton accelerator and promoting a neutron science project for comprehensive studies on basic science and nuclear transmutation of high-level radioactive nuclide from nuclear power stations. For this purpose, JAERI organized the Special Taskforce for Neutron Science and OMEGA Project in April 1996 and reorganized it to Center for Neutron Science in April 1997. During this period, various research plans using the spallation neutron source are proposed and facilities necessary for research are studied by mainly research groups of JAERI. This report describes research plans and results of the preliminary conceptual design study on proposed facilities plan. (author)
Neutron energy spectra were measured for two OSURR experimental facilities. The method of multiple foil activation was used with the SAND-II neutron spectrum unfolding code to obtain spectral data for the Central Irradiation Facility and Rabbit tube. Limited data was obtained for the thermal column using only gold foils. Calculations were made of the neutron environment in various locations using the MORSE code. A shift towards higher neutron energies was observed comparing results for LEU and HEU cores. A slight loss in total thermal neutron flux was measured for all positions. Calculational results show reasonable agreement with measured data.
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has recently been developed at the University of Texas TRIGA reactor. Extensive Monte Carlo design calculations were used to determine optimal design parameters of the neutron collimator system to avoid costly trial and error. Thermal neutron flux determined by gold foil activation is 5 {times} 10{sup 6} n/cm{sup 2}{center_dot}s at the primary imaging location with beam size of 22.5 cm in diameter. The collimation ratio can be varied from 125 to 235. The neutron-to-gamma ratio is 7.8 {times} 10{sup 6} n/cm{sup 2}{center_dot}mR. The facility has been tested for radiography and tomography applications and is now fully operational.
A neutron scanning device was developed in order to obtain accurate neutron intensities of high burn-up BWR fuels. This scanning device was calibrated with a "2"5"2Cf source and used to measure axial distributions of neutron intensities of BWR fuels with various enrichments (2.0%-3.4%) irradiated up to 60 GWd/tU at Fukushima Daini Nuclear Power Station Unit 2(2F-2). The measured neutron intensities were approximated well with power law interpolations on the calculated burn-up values. The neutron intensities calculated by the ORIGEN2-86 code showed good agreements with the measured ones within 20%. (author)
Measurements of neutron and gamma-ray penetrations in an iron shield were performed up to a 60-cm depth in a tightly coupled source shield configuration with the fast-neutron reactor YAYOI as a source. Rates of neutron reactions and gamma-ray dose rates in the iron shield were obtained using activation foils and thermoluminescent dosimeters. Analyses of the experiments were made by using the DOT-III code with coupled neutron and gamma-ray cross sections from ENDF/B-IV and POPOP4 libraries. To obtain the source condition for the iron shield analyses, the calculated spectrum was adjusted to the measured reaction rates at the reactor shield boundary. The calculated neutron and gamma-ray distributions in the iron shield show fairly good agreement with the experiments. The effect of difference in Bondarenko-type self-shielding factors on the analyses of the iron shield is also shown.
A successful boron neutron capture treatment (BNCT) of a patient with multiple liver metastases has been first given in Italy, by placing the removed organ into the thermal neutron column of the Triga research reactor of the University of Pavia. In Finland, FiR 1 Triga reactor with an epithermal neutron beam well suited for BNCT has been extensively used to irradiate patients with brain tumors such as glioblastoma and recently also head and neck tumors. In this work we have studied by MCNP Monte Carlo simulations, whether it would be beneficial to treat an isolated liver with epithermal neutrons instead of thermal ones. The results show, that the epithermal field penetrates deeper into the liver and creates a build-up distribution of the boron dose. Our results strongly encourage further studying of irradiation arrangement of an isolated liver with epithermal neutron fields.
The effects of group structures and weighting functions on neutron penetration through a thick Na-Fe geometry are studied. The recommended broad-group (61-neutron/23-gamma-ray) and few-group (22-neutron/10-gamma-ray) structures are tailored to the sodium and iron resonances, windows, and capture gamma-ray spectra. The best weighting functions are shown to be fine-group fluxes selected from a few key locations in the geometry. These group structures and weighting functions, relative to existing group structures and conventional weighting functions, improve the accuracy of the computed 61-neutron-group Bonner ball responses by up to one hundred percent and of the computed 22-neutron-group results by up to six hundred percent.
An apparatus for non-invasively inspecting an object, such as an item of luggage, for explosives material is described. It comprises a multi-channel thermal neutron inspection system having a plurality of neutron irradiation chambers. Simultaneous operation of several channels increases the maximum system throughput several times. Each chamber has a lithium neutron source which is stimulated to neutron production by a proton beam. Beam switching magnets are energised by pulsing to divert a common proton beam to each source in turn. The initial beam is generated by a radio frequency quadrupole accelerator. The advantages of this system are very low residual source activity and controllable neutron production thereby minimising safety hazards. The irradiation chamber may contain several different gamma ray detectors to identify the elements present in explosives material. In addition, ...
Three electronic personal dosimeters (EPD-N) manufactured by Siemens, serial numbers 0635, 0658, and 0683, were tested at the Radiation Calibration Laboratory for an evaluation of their response to neutron, gamma and x-ray radiation. Designed to provide real-time neutron and photon dosimetry, the EPD-N is capable of estimating and displaying neutron and gamma dose components separately for a range of energies from 50 keV to 7 MeV for photon and 0.025 eV to > 10 MeV for neutron. All tests were conducted using the factory calibrations. A technical representative of the manufacturer indicated that site-specific calibrations are required as factory settings are calibrated for the lowest neutron energy limit of 0.025 eV. This raises concerns about the reliability of these devices in measuring neutrons when calibrations are made for a specific site radiological ...
A new methane cold neutron source has been tested at the IBR-2 pulsed reactor at the Frank Laboratory of Neutron Physics. In a paper the results of experiments at neutron diffractometers HRFD and DN-2 which are placed at the IBR-2 from the methane moderator side are given. A comparison with the results obtained with the conventional water comb-like moderator is performed. The perspectives of the cold source for various kinds of neutron diffraction experiments, including atomic and magnetic structural analysis and real time experiments are discussed. It is shown, that for a huge number of the experiments which are performing at both HRFD and DN-2 the methane cold neutron source provides the better conditions than water comb-like moderator.
The coupled neutron-gamma cross section libraries BUGLE-80 and SAILOR are compared, with focus on gamma production and transport and its sensitivity to the thermal component of the neutron flux. In addition, the importance of the prompt versus delayed components of the gamma source is addressed. Although BUGLE-80 shows some discrepancies in the core region, the two libraries demonstrate similar capability in the vicinity of the pressure vessel and beyond. The delayed fission product gammas from the core have little impact on the local gamma fluxes beyond the pressure vessel. Although thermal neutron capture is the dominant component of the gamma source, there is little sensitivity of the gamma source to uncertainties in the thermal neutron cross sections, due to compensating effects which tend to keep the thermal neutron capture rate relatively constant.
Abstract - We have designed, built, and tested a 2-D pixellated thermal neutron detector. The detector is modeled after the MicroMegas-type structure previously published for collider-type experiments. The detector consists of a 4X4 square array of 1 cm 2 pixels each of which is connected to an individual preamplifier-shaper-data acquisition system. The neutron converter is a 10B film on an aluminum substrate. We describe the construction of the detector and the test results utilizing 252Cf sources in Lucite to thermalize the neutrons.Drift electrode (Aluminum) Converter (10B) 3 mm Conversion gap neutron (-900 V)
The GSD must be considered as a quantity by means of which the risk in a given population can be described exclusively in terms of genetic risk. In cases of a simultaneous increase in the rate of examinations, the GSD may lead to a misinterpretation of the population exposure, suggesting a decreasing trend, although there is an actual increase in the somatic radiation exposure. It is recommended to indicate not only the GSD but also the amount of somatic radiation exposure of the population for each specific source when comparing and evaluating radiation exposures from different sources. Although the somatically significant dose formally would be suited as a complement to the GSD, it is recommended to use the effective per caput dose equivalent. It must be pointed out that the application of the concept of effective dose equivalent is only appropriate for comparative evaluations of the population exposure to different sources of radiation. ...
A two-dimensional (2D) lattice model with anisotropic resonant microstructures is found to provide an anisotropic band gap structure. A 2D continuum with anisotropic effective mass density is introduced to represent this lattice system. Two methods are proposed to derive the equivalent continuum. In the first method, the effective mass density of the equivalent continuum is obtained by matching the dispersion relations for harmonic waves propagating in the principal directions. The second approach employs an approximate estimation of the effective mass density by volume-averaging an effective mass that represents the resonant microstructure. For both equivalent continuum models, the effective mass density is frequency-dependent and may become negative in certain frequency ranges. Subsequen...
In this report we focus on some aspects related to modeling and formal verification of embedded systems. Many models have been proposed to represent embedded systems . These models encompass a broad range of styles, characteristics, and application domains and include the extensions of finite state machines, data flow graphs, communication processes and Petri nets. In this report, we have used a PRES+ model (Petri net based Representation for Embedded Systems) as an extension of classical Petri net model that captures concurrency, timing behaviour of embedded systems; it allows systems to be representative in different levels of abstraction and improves expressiveness by allowing the token to carry information. Modeling using PRES+, as discussed above, may be convenient for specifying the input behaviour because it supports concurrency. However, there is no equivalence checking method reported in the literature for PRES+ models to the best of our knowledge. In ...
Since Taiwan lacks sufficient self-produced energy, increasing energy efficiency and energy savings are essential aspects of Taiwan's energy policy. This work summarizes the energy savings implemented by 303 firms in Taiwan's textile industry from the on-line Energy Declaration System in 2008. It was found that the total implemented energy savings amounted to 46,074 ton of oil equivalent (TOE). The energy saving was equivalent to 94,614 MWh of electricity, 23,686 kl of fuel oil and 4887 ton of fuel coal. It represented a potential reduction of 143,669 ton in carbon dioxide emissions, equivalent to the annual carbon dioxide absorption capacity of a 3848 ha plantation forest. This study summarizes energy-saving measures for energy users and identifies the areas for making energy saving to provide an energy efficiency baseline.
Two perfluorosulfonic acid membranes, Nafion{sup R} 105 and Nafion{sup R} 115 with the same thickness but different equivalent weights (EW = 1000 g/eq. resp. 1100 g/eq.) were characterised by conductivity measurements at different water vapour activities in the temperature range of 25-70{sup o}C. The results demonstrate that a lower membrane equivalent weight opens the possibility to obtain the needed proton conductivity at lower water vapour activity. This is especially important for those fuel cell applications, in which the cell is operated without external humidification of the fuel gases. (author) 5 figs., 5 refs.
A tissue-equivalent dosimetry system has been developed for use in absorbed dose determinations with physical models of Reference Man. The dosimeter used was a thermo-luminescent dosimeter (TLD) powder which was mixed with a 'tissue-equivalent' material and modeled to closely approximate an organ's geometry and absorption properties. A separation procedure was developed by which the TLD powder was washed and the 'tissue-equivalent' material, a wax, was dissolved and extracted following the irradiation of the model. The procedure was tested to determine losses of powder, homogeneity of the powder's distribution throughout the wax, the effects of the separation procedure upon the powder and the statistical behavior of the procedure. The results of these tests established the feasibility of the procedure. A full-scale model of the pancreas was tested and the results supported the validity of the technique. (author)
The full text follows. A thermal neutron imaging facility (TNIF) capable of real time neutron radiography and computed tomography was developed for the University of Texas TRIGA Mark II (UT-TRIGA) reactor from 1994-1998. The facility was developed with a through reactor beam port capable of producing a 5.2 x 10{sup 6} n/cm{sup 2}/s thermal neutron flux with a gamma dose rate of less than 1 mR/s after collimation. The original TNIF included the UT-TRIGA reactor, neutron collimation array, sample positioning system, neutron image intensifier tube, video camera, computerized image acquisition system, and a radiation shield. A 0.7 mm slit in cadmium was easily detectable using neutron radiography, and 1.4 mm diameter holes bored in an aluminum block were easily resolved using computed neutron tomography. Precise lower limits of the system ...
High precision fundamental neutron physics experiments have been proposed for the intense pulsed spallation neutron beams at JSNS, LANSCE, and SNS to test the standard model and search for new physics. Certain systematic effects in some of these experiments have to be controlled at the few ppb level. The NPD Gamma experiment, a search for the small parity-violating {gamma}-ray asymmetry A{sub Y} in polarized cold neutron capture on parahydrogen, is one example. For the NPD Gamma experiment we developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to rf neutron spin flippers based on ...
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...
Boron Neutron Capture Therapy (BNCT) is a promising binary treatment modality for high-grade primary brain tumors (glioblastoma multiforme, GM) and other cancers. BNCT employs a boron-10 containing compound that preferentially accumulates in the cancer cells in the brain. Upon neutron capture by {sup 10}B energetic alpha particles and triton released at the absorption site kill the cancer cell. In order to gain penetration depth in the brain Fairchild proposed, for this purpose, the use of energetic epithermal neutrons at about 10 keV. Phase I/II clinical trials of BNCT for GM are underway at the Brookhaven Medical Research Reactor (BMRR) and at the MIT Reactor, using these nuclear reactors as the source for epithermal neutrons. In light of the limitations of new reactor installations, e.g. cost, safety and licensing, and limited capability for modulating the reactor based neutron ...
The Neutron Radiography Reactor (NRAD) operated by Argonne National Laboratory is described in this paper. NRAD was designed to allow radiography of highly absorbing reactor fuel assemblies in the vertical position on the routine basis. 7 figs.
Revised neutron fluence and damage values are reported for the MOTA-2A experiment in the Fast Flux Test Facility (FFTF). This revision corrects an error with processing of the {sup 235}U(n,f) reaction. Net corrections are on the order of 5%.
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique.
This neutron reflectometry study evaluates the structures resulting from different methods of preparing polymer-cushioned lipid bilayers. Four different techniques to deposit a dimyristoylphosphatidylcholine...Full Text Available
The observation by inelastic neutron scattering techniques of a high energy peak in the phonon spectrum (14 THz) of V_3Si is reported, and is attributed to a peak in the phonon density of states due to vanadium motions by the incoherent inelastic neutron scattering process.
We argue that neutron interference experiments and experiments on gravitational bound states of neutron unambiguously disprove entropic origin of gravitation. The criticism expressed in a recent paper [arXiv:1104.4650] concerning our arguments against entropic gravity is shown to be invalid.
The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich {sup 101}Sr to the neutron-deficient {sup 101}In.
The 1985 evaluation of A = 1-1 (85B1114) has been revised. Experimental information is presented from the neutron-rich "1"0"1Sr to the neutron-deficient "1"0"1In.
A study of the joint evolution of the normal- and neutron-star components of massive binaries opens with a classification scheme and the analytic expressions to be applied in Paper II for computer simulation of the observable properties of such systems.
Neutron Star Evolution with Internal Energy h'q/>a. Dissipation by Vortex Creep. N. Shibazaki and F. K. Lamb. University of Illinois at Urbana-Champaign ...
The availability of new, high-intensity, cold and thermal neutron sources has opened the possibility of performing high-precision fundamental neutron physics experiments, including measurements that study the hadronic weak interaction and standard model test measurements, using neutron decay. The observables in these experiments are usually correlated with the direction of neutron polarization and are often very small (10 8 10 6). Mott-Schwinger scattering of polarized neutrons can produce spin-dependent shifts in beam centroids, which has the potential to produce significant systematic effects for these types of experiments. An accurate calculation of this process for neutral atoms and basic molecules has not been carried out for low neutron energies. In this work, we derive a general expression for the electromagnetic (Mott-Schwinger) contributions to the ...
We present the results of modeling intended to evaluate the feasibility of using neutrons from induced fission in highly enriched uranium (HEU) as a means of detecting clandestine HEU, even when it is embedded in absorbing surroundings, such as commercial cargo. We characterized radiation from induced fission in HEU, which consisted of delayed neutrons at all energies and prompt neutrons at energies above a threshold. We found that for the candidate detector and for the conditions we considered, a distinctive HEU signature should be detectable, given sufficient detector size, and should be robust over a range of cargo content. In the modeled scenario, an intense neutron source was used to induce fissions in a spherical shell of HEU. To absorb, scatter, and moderate the neutrons, we place one layer of simulated cargo between the source and target and an identical layer between the ...
The cosmic ray neutron spectrum at sea level has been measured by the method of pulse shape discrimination in anthracene scintillator. The exponent of the differential spectrum was found to be 2.2+-0.1. (Auth.).
An analytic model of magnetic torques applied to an accreting neutron star is employed to evaluate the magnetic dipole moments of x-ray pulsars. A new type of close binary system containing a neutron star is suggested.
A technique was developed that permits fluid flow to be visualized even where the flow is completely shrouded by metal. The technique employs real-time neutron radiography, which is similar to x-ray radiography except a collimated beam of neutrons is used. Various combinations of neutron-opaque tracer materials were tested with neutron-transparent fluid. Neutron opaque tracers, such as solid particles, fluid droplets, and streaklines were imaged through metal walls as they convected in neutron-transparent ambient fluid. Visualization of bubbles/voids were evaluated for possible future applications. Surface-flow patterns were also imaged by using neutron-opaque tufts. These techniques were evaluated for image contrast, resolution, and the ability to accurately track fluid flow fields. The techniques were also modeled to optimize contrast in ...
A prototype detector based on the inclined boron layer principle is introduced. For typical measurement conditions at the Liquids Reflectometer at the Spallation Neutron Source, its count rate capability is shown to be superior to that of the current detector by nearly two orders of magnitude.
A prototype detector based on the inclined absorber layer principle is introduced. For the Liquids Reflectometer at the Spallation Neutron Source, it is shown to be a significant improvement over its current detector, which imposes an instantaneous count rate limitation of 50 kcps.
Main features of star evolution are recalled. Then the general structure of white dwarf stars is examined. From the equation of state of an electron gas completely degenerated are deduced: mechanical equilibrium, Viriel theorem, mass-radius relationship and Chandrasekhar limit. These results are applied to neutron stars.
Careful measurements do not confirm an anomalous anisotropy in the angular distribution of fission fragments from the fast neutron fission of Americium 242. The energy range covered was 1.60-3.15 MeV. (AIP)
An array of multiwire proportional counters has been employed to image, in 'real-time', a collimated neutron beam produced at an electron linac facility. Test results are presented, along with a discussion of the advantages of this technique. (orig.).
BackgroundThe precision in carbon ion radiotherapy depends on the calibration of Hounsfield units (HU) as measured with computed tomography (CT) to water equivalence. This calibration...Full Text Available
Ten subjects balanced their own body or a mechanically equivalent unstable inverted pendulum by hand, through a compliant spring linkage. Their balancing process was always characterized by repeated...Full Text Available
It was found that neither the enzymes of the grapes nor those of wine yeast Saccharomyces ellipsoideus strain 223 attacked the higher polysaccharides present in corn syrups. The alcohol...Full Text Available
Provides standardized energy balance sheets expressed in a common unit of tons of oil equivalent for all OECD countries as well as the regions: OECD total, IEA, North America, Pacific, OECD Europe, EEC and Yugoslavia.
A pedagogical introduction to the equivalence theorem for longitudinal vector bosons in electroweak theories is given and the problem of tree-level unitarity at high energies in models of electroweak interactions is briefly reviewed. To make the treatment self-containded, the basic of the Standard Model are summarized in an appendix.
Ayurvedic drugs have begun to be evaluated in controlled clinical trials. The trials, often placebo controlled, are usually designed to demonstrate superiority. Though the results have been usually...Full Text Available
disposal through HC, and the effects of kerbside collection (KC) of recyclable materials, by measuring ...waste equivalent to 12 % could be attributed to HC and KC.Comparisons between the residual weight data for ...Control showed that the contributions of HC and KC to the overall reduction in residual waste were
This report describes mathematical predictions for the migration of radionuclides from an emplaced radioactive waste container. The model assumes a spherical-equivalent waste solid surrounded by backfill but neglects the effect of decay heat. 7 refs., 2 tabs. (TEM)
The mammalian neocortex consists of six layers. By contrast, the reptilian and avian cortices have only three, which are believed to be equivalent to layers I, V and VI of mammals. In mammals, the majority...Full Text Available
BackgroundThe Emergency Care Summary (ECS) was introduced in 2006 to allow aspects of the general practitioner (GP; family doctor, equivalent to primary care physician) medical record...Full Text Available
Phase transformations in TiD_#approx#_0_._7_5 subjected to high-pressure treatment were investigated by simultaneous real-time measurements of neutron diffraction and small-angle neutron scattering. The neutron spectra were taken on heating the samples in temperature ranges 100 to 300 K and 300 to 870 K. A sequence of structural transitions was observed, which involves 7 different phases and intermediate states with hcp, fcc, fco or bcc metal sublattices and hydrogen atoms. 30 refs., 9 figs., 1 tab.
We report on measurements of radiation hardness of the plastic scintillating fiber SCSF-81. Fibers were irradiated with "6"0Co #gamma#-rays and fast neutrons up to 105 Gy and up to 5 x 1013 n/cm"2, respectively. Deterioration of the attenuation length of the scintillating fiber was studied. Some significant deterioration was observed at the integrated dose of about 1 x 103 Gy and at the integrated neutron flux (neutron fluence) of about 1 x 1012 n/cm"2 for #gamma#-ray and neutron irradiation, respectively. (author).
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
An advanced video system has been assembled from commercially available equipment to support the real-time neutron radiography facility established jointly by the University of Virginia Department of Nuclear Engineering and Engineering Physics, and the Philip Morris Research Center. A schematic diagram of the equipment used for real-time neutron radiography is presented. To obtain quantitative density measurements with this system, several modifications of both hardware and image processing software were required. After implementation of these changes, the system was capable of determining material densities by measuring the degree of neutron attenuation.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q{sup 2}=1.0-4.8 GeV{sup 2} with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
The neutron elastic magnetic form factor was extracted from quasielastic electron scattering on deuterium over the range Q2=1.0-4.8 GeV2 with the CLAS detector at Jefferson Lab. High precision was achieved with a ratio technique and a simultaneous in situ calibration of the neutron detection efficiency. Neutrons were detected with electromagnetic calorimeters and time-of-flight scintillators at two beam energies. The dipole parametrization gives a good description of the data.
Neutron resonance interactions with /sup 100/Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% /sup 100/Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture ..gamma..-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images. (author).
Fission reaction rates for four nuclides were measured in the leakage spectrum outside spherical water moderators of various radii surrounding a {sup 252}Cf neutron source. Using the MCNP transport code, matching calculations were made with highly detailed modeling of the measurement apparatus. The calculations predicted significantly higher leakage of neutrons in the epicadmium energy range than was found in the measurements. A discrepancy of the same sign but weaker magnitude was found for thermal neutrons. These discrepancies may be relevant to problems with criticality calculations in special cases.
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
Energy conservation and local energy deposition are investigated in the context of coupled-particle (i.e., neutrons, gamma rays, and charged particles) transport analysis. For charged particles, the concept of group splitting the 1 = 0 transfer matrix to ensure both particle and energy conservation is introduced. Although these procedures are more complex than those found in the usual neutron or coupled-neutron gamma-ray problem, they yield a consistent approach for the calculation of local energy deposition.
Abstract. The modification of kaon and antikaon properties in the interior of (proto-)neutron stars is investigated using a chiral SU(3) model. The parameters of the model are fitted to nuclear-matter saturation properties, baryon octet vacuum masses, hyperon optical potentials and low-energy kaon-nucleon scattering lengths. We study the kaon/antikaon medium modification and explore the possibility of antikaon condensation in (proto-)neutron star matter at zero as well as finite temperature/entropy and neutrino content. The effect of hyperons on kaon and antikaon optical potentials is also investigated at different stages of the neutron star evolution.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
This report summarizes the major activities and accomplishments of the Idaho National Engineering and Environmental Laboratory (INEEL) Advanced Radiotherapy Research Program for calendar year 2001. Applications of supportive research and development, as well as technology deployment in the fields of chemistry, radiation physics and dosimetry, and neutron source design and demonstration are described. Contributions in the fields of physics and biophysics include development of advanced patient treatment planning software, feasibility studies of accelerator neutron source technology for Neutron Capture Therapy (NCT), and completion of major modifications to the research reactor at Washington State University to produce an epithermal-neutron beam for NCT research applications.
The spherical harmonic analysis of cosmic ray neutron data from the worldwide network neutron monitor stations during the years 1966 to 1969 was carried out. The second zonal harmonic component obtained from the analysis corresponds to the Pole-Equator anisotropy of the cosmic ray neutron intensity. Such an anisotropy makes a semiannual variation. In addition to this, it is shown that the Pole-Equator anisotropy makes a variation depending on the interplanetary magnetic field (IMF) sector polarities around the passages of the IMF sector boundary. A mechanism to interpret these results is also discussed.
We made Basic designs of neutron guide, choppers, and detectors in order to optimize the design parameters of DC-TOF to be built in the HANARO Cold Neutron Guide Hall. In addition, we calculated the expected performance of DC-TOF using Monte Carlo simulations and evaluated the properties of neutron beam. Based on the results we obtained, we have compared the expected performance of the DC-TOF with those of existing instruments overseas. In conclusion, we believe that we will be able to construct the DC-TOF at HANARO as one of the best instruments of its kinds and it will become an invaluable instrument to researchers in the related field.
Instrumental neutron activation analysis is used for simultaneously determination of macrocomponents in ferroelectric materials LLZT. Pb, Zr, Ti have been determined by "2"0"3Pb, "8"9Zr and "4"8Sc nuclides created by fast neutron (14.5 MeV) activation. Application of paraffine as neutron moderator and reflector allows to simultaneously determine lanthanum by "1"4"0La nuclide. It has been shown that zirconium, titanium and lanthanum can be determined with the accuracy of #+-#0.1 mas. % and lead - #+-#0.7 mas. %.
We have developed a new type personal dosemeter by using a B-10 doped silicon p-n junction detector with a polyethylene radiator and a polyethylene moderator. The purpose of this study was to develop a real time neutron dosemeter with a nearly flat response in the energy range from thermal to 15 MeV and low angular dependence to the incident neutron direction. The neutron response of the dosemeter was obtained with the Monte Carlo calculation and the monoenergetic neutron experiment in a free air field and also under a condition attached on a phantom.
A powder neutron diffraction study has been carried out on /sup 239/PuN, which was reported to be antiferromagnetic below T = 13 K. No magnetic ordering has been detected at 4 K, the limit of the magnetic ordering which could be detected being ..mu..sub(ord) = 0.25 ..mu..sub(B) per Pu atom. Moreover a neutron scattering length determination of /sup 239/Pu was performed which gave a value of bsub(239Pu) = (0.81 +- 0.05) x 10/sup -12/ cm at a neutron wavelength lambda = 1.219 A.
Noncommutative tori are among historically the oldest and by now the most developed examples of noncommutative spaces. Noncommutative Yang-Mills theory can be obtained from string theory. This connection led to a cross-fertilization of research in physics and mathematics on Yang-Mills theory on noncommutative tori. One important result stemming from that work is the link between T-duality in string theory and Morita equivalence of associative algebras. In this article we give an overview of the basic results in differential geometry of noncommutative tori. Yang-Mills theory on noncommutative tori, the duality induced by Morita equivalence and its link with the T-duality are discussed. Noncommutative Nahm transform for instantons is introduced.
In radiation risk assessment it must be differentiated between somatic and genetic effect on the one hand as well as between stochastic and non-stochastic effect on the other. According to definitions of the ICRP report 26 the limit for the dose equivalent of all tissues prevents non-stochastic radiation effects. With stochastic radiation effects probably exist no threshold doses; therefore the ALARA principle must be applied concerning radiation protection. The individual risk by stochastic radiation effects in its linear, linear-quadratic and quadratic extrapolations, respectively, is discussed in detail. The effective stochastic dose equivalent (H/sub eff/) as well as collective dose and collective damage are outlined.
The NPPs safety system in Germany is discussed. It is shown that there exists no threat for the German NPPs at the peace times. They release insignificant quantities of radioactive substances into the water and atmosphere. The average equivalent dose constitutes 0.0005 mSv annually. The annual equivalent dose for the personnel is equal to 4.4 mSv. At the same time, the NPPs contribute to a certain degree to the environmental medium improvement, preventing the ingress therein of the sulfur and carbon dioxide, dust and nitrogen oxides by application of fossil fuels. Attention is also paid to reprocessing facilities and also to the nuclear fuel wastes disposal. The advantages of the nuclear power engineering in comparison with the fossil fuel power engineering are enumerated
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
In order to understand the detail transient two-phase flow structure, more advanced two-phase flow instrumentation is required. One advanced technique for flow visualization is real-time neutron radiography. Reconstruction method of visualized radiographic image of liquid metal two-phase flow generated by the real-time neutron radiography system is proposed in this paper. Image processing techniques for noise reduction and image enhancement are discussed in detail. (author).
Using the Relativistic Mean Field Theory (RMF) it is shown that different proton fraction which is directly connected with the neutron excess and with the asymmetry of the system affects proto-neutron stars parameters and changes their composition. The obtained form of the equation of state allows to construct the mass-radius relations and shows that the increasing asymmetry creates more compact stars. The inclusion of {delta} meson together with nonlinear vector meson interaction terms and magnetic field make this effect even stronger.
The properties of strange neutron stars have been studied with the use of the parameter sets stemming from the effective field theory. The impact of the strength of hyperon interactions on neutron star masses has been analyzed. The inclusion of additional nonlinear meson interaction terms together with the strong hyperon-hyperon interaction leads to the existence of additional stable stellar configurations. (authors)
The current status and future plans of the Ok Ridge Spallation Neutron Source (ORSNS) are reviewed. The ORSNS is a new project initiated by the U.S. Department of Energy (DOE) beginning October 1, 1995, to prepare the conceptual for a new spallation neutron source. (author) 2 refs.
The status of neutron activation cross sections for some threshold reactions important for reactor materials dosimetry is reviewed. An attempt is made to understand and explain discrepancies between integral and differential data, using recent available experimental results. The importance of standard and benchmark neutron fields for testing differential data for reactor dosimetry is emphasized and the Interlaboratory Reaction Rate (ILRR) program, as well as a similar program pursued by the IAEA, are briefly described.
The energy distribution of neutrons generated due to bombardment of 40 MeV alpha particles on thick elemental tantalum is measured using threshold activation detectors. A method of unfolding the neutron spectrum from the activation data based on information-entropy weighted average solution is described. The present unfolding method does not require 'a priori' information about the shape of the solution spectrum. 16 refs. (author).
Structural units of a hydrogen fuel cell whose characteristics are advisable to investigate by different neutron scattering methods are discussed. The results obtained with the use of Bragg diffraction and small-angle neutron scattering from fuel membranes, nanocarbon-platinum catalysts, and Zn_1_-_xCu_xO hydrogen storage systems are presented.
The structural variations of amorphous metals, such as Pd/sub 80/Si/sub 20/, with irradiation of helium ion, neutron, and gamma ray have been mainly pursued by the method of X-ray diffraction and thermal analysis. It should be noticed that the amorphous metals show a radiation resistance, that is, no remarkable structural changes under helium ion, neutron, and gamma ray irradiation.
Recent nucleosynthesis calculations of Type II supernovae using advanced neutrino transport determine that the early neutrino winds are proton-rich. However, a fraction of the ejecta emitted at the same time is composed of neutron-rich pockets. In this paper we calculate the nucleosynthesis contribution from the neutron-rich pockets in the hot convective bubbles of a core-collapse supernova and show that they do not contribute significantly to the total nucleosynthesis.
This meeting focussed on the study of the structure and dynamics of biological molecules, with particular emphasis on neutron and complementary methods as well as related enabling technologies. The program covered biological problems that are being addressed by neutron scattering and those where there is the potential to do so in the future. This document provides the abstracts of the different presentations. (A.L.B.)
The image processing system for the dynamic neutron radiography has been developed. It is based on the hardware subset, composed by the method of the pipe-line and use of algorithm of local statistics. The processing speed per one pixel is shorter than 100 n sec and video-rate processing can be executed on it. Some image processes for improving the quality of the real-time neutron image, noise reduction and contrast stretching would be attempted by the use of this system. (author).
The importance of neutron measurements both as a succinct measure of the progress to fusion ignition using the magnetic confinement route and also as a diagnostic of plasma conditions is discussed. The various neutron diagnostic systems that have been or are being constructed by AERE Harwell for JET are described. The properties to be measured by such diagnostics are clearly identified and some results obtained with the installed diagnostics during d-d plasmas are presented.
ORNL has developed the technology to detect hidden explosives in luggage using X ray and neutron detection devices. The Federal Aviation Administration has ordered the airlines to buy and install Thermal Neutron Analysis (TNA) units. The combined pulsed-neutron and X-ray interrogation inspection (CPNX) system developed at ORNL uses less radioactive materials as well as being more sensitive to weapons, electronic devices and plastic explosives.
The gamma-ray spectrum following neutron capture on /sup 87/Sr was measured at 3 neutron energies: E/sub n/ = thermal, 2 keV, and 24 keV. Gamma rays were detected in a three-crystal Ge(Li)-NaI-NaI pair spectrometer. Gamma-ray intensities deduced from these spectra by spectral unfolding are presented.
A facility for studying photon-neutron reactions under a braking #gamma#-beam with an energy of up to 26 MeV from a betratron includes Saratov-2, SM-4A, and IBM AT-386 microcomputers. Neutron detectors, pulsed braking radiation dosimeters, and the devices to control the betatron energy are described.
In this study the development of a methodology to detect illicit drugs and plastic explosives is described with the objective of being applied in the realm of public security. For this end, non-destructive assay with neutrons was used and the technique applied was the real time neutron radiography together with computerized tomography. The system is endowed with automatic responses based upon the application of an artificial intelligence technique. In previous tests using real samples, the system proved capable of identifying 97% of the inspected materials.
The theory of neutron moderation and spectroscopy are briefly reviewed, and moderators that are useful for Bonner sphere spectrometers are discussed. The choice of the neutron detector for a Bonner sphere spectrometer is examined. Spectral deconvolution methods are briefly reviewed, including derivative, parametric, quadrature, and Monte Carlo methods. Calibration is then discussed. (LEW)
The principal mathematical tools frequently available for calculations in Nuclear Engineering, including coupled neutron-gamma radiations shielding problems, involve the full Transport Theory or the Monte Carlo techniques. The Multigroup Albedo Method applied to shieldings is characterized by following the radiations through distinct layers of materials, allowing the determination of the neutron and gamma fractions reflected from, transmitted through and absorbed in the irradiated media when a neutronic stream hits the first layer of material, independently of flux calculations. Then, the method is a complementary tool of great didactic value due to its clarity and simplicity in solving neutron and/or gamma shielding problems. The outstanding results achieved in previous works motivated the elaboration and the development of this study that is presented in this dissertation. The radiation balance ...
This report documents radionuclide air emission from the Hanford Site in 1997, and the resulting effective dose equivalent to the maximally exposed member of the public, referred to as the MEI. The report has been prepared in accordance with reporting requirements in the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emissions Standards for Hazardous Air Pollutants, Subpart H, National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities. This report has also been prepared in accordance with the reporting requirements of the Washington Administrative Code Chapter 246-247, Radiation Protection-Air Emissions. The effective dose equivalent to the MEI from the Hanford Site`s 1997 point source emissions was 1.2 E-03 mrem (1.2 E-05 mSv), which is well below the 40 CFR 61 Subpart H regulatory limit of 10 mrem/yr. Radon and thoron emissions, exempted from 40 CFR ...
The purpose was to identify human in vitro cell lines with a high relative cellular sensitivity to fast neutrons as compared to photons and to examine their relationship to intrinsic photon radiosensitivity and cellular proliferation kinetics. The clonogenic cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell survival following exposure to low LET, 4 MeV photons or, high LET, 62.5 MeV (p #-># Be"+) fast neutrons and the cell kinetic parameters of 30 human in vitro cell lines, covering a wide range of histologies, were analyzed alone and with previously published data of Fertil and Malaise. The relative survival at 1.6 Gy of neutrons (SF_1_._6) compared to 2 Gy of photons (SF_2) and the cell kinetic parameters of the 30 cell lines were also compared. The relative lethality of 62.5 MeV fast neutrons was ...
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10{sup 7} neutrons cm{sup -2}s{sup -1} and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t{sub s} of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
Real-time neutron powder diffraction and small-angle scattering techniques have been developed on the TOF diffractometer DN-2 at the IBR-2 pulsed reactor at JINR (Dubna) with a total flux on the sample of 10"7 neutrons cm"-"2s"-"1 and a resolution of about 1%. A special arrangement of the detector system ensures a high counting rate of diffracted neutrons. Depending upon sample type and experimental conditions, the measuring time t_s of one neutron pattern varies from a few minutes to several seconds. The performance of the diffractometer is discussed and typical data are shown to demonstrate current achievements using real-time techniques at a pulsed reactor. (orig.).
The report considers experimental and theoretical works on studying the energy spectra of prompt neutrons emitted in spontaneous fission and neutron induced fission of Minor Actinides. It is noted that neutron spectra investigations were done for only a small number of such nuclei, most measurements, except those of Cf-252, having been carried out long ago by obsolete methods and imperfectapparatus. The works have no detailed description of experiments, analysis of errors, detailed numerical information about results of experiments. A conclusion is made that the available data do not come up to modern requirements. It is necessary to make new measurements of fission prompt neutron spectra of transuranium nuclides important for the objectives of working out a conception of minor actinides transmutation by means of special reactors. (author).
In order to assess various core parameters a reference equilibrium core with Low Enriched Uranium (LEU) fuel for Pakistan Research Reactor (PARR-1) was assembled. Due to increased volume of reference core, the average neutron flux reduced as compared to the first higher power operation. To get a higher neutron flux an irradiation facility was created in centre of the reference equilibrium core where the advantage of the neutron flux peaking was taken. Various low power experiments were performed in order to evaluate control rods worth and neutron flux mapping inside the core. The neutron flux inside the central irradiation facility almost doubled. With this arrangement reactor operation time was cut down from 72 hours to 48 hours for the production of the required specific radioactivity. (author)
Real Time Radiography (RTR) finds extensive applications for inspection of objects on assembly lines for rapid inspection. A typical RTR widely used includes a image intensifier, CCD camera, image processor and high resolution TV monitor in addition to radiographic source. Image intensifiers used in X-radiography employ CsI as the input detector. With the increased use of neutrons as radiation source, real time neutron radiography is also being practised widely. Image intensifiers used in neutron radiography employ gadolinium as the input screen. The neutron image intensifier system at the authors laboratory essentially consists of a 9 inch Trifield image intensifier tube, motorised zoom lens, CCD camera and a high resolution TV monitor
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Illinois. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged.
A real time neutron radiography system has been developed at the University of Michigan Phoenix Memorial Laboratory (PML) and has recently been used to test the imaging capabilities of a neutron imaging device developed by Lixi, Inc. of Downers Grove, Ill. This device uses an input phosphor that is high in gadolinium to generate a light image which is then sent through an intensifier stage to provide images that can be viewed by eye, video camera, or standard 35 mm camera. It was determined that this device provides images of much higher resolution and sensitivity than those obtained with the imaging system currently being used at PML. Using computerized image enhancement techniques, the images obtained with the Lixi neutron imaging device can then be further enhanced or processed to obtain quantitative information on the object being imaged. (orig.).
The Advanced MAPLE is a research reactor design under development as a high-flux neutron source. The main performance goals for the reactor are a high peak thermal neutron flux in a heavy-water reflector tank, and a high average fast neutron flux in a central irradiation facility, with a maximum linear fuel rod rating of less than 120 kW/m. This study investigated the neutronic and reactor design consequences of the use of H_2O coolant as opposed to D_2O. The neutronics results, and several other considerations, indicate that H_2O coolant has a number of advantages. It is suggested that the H_2O coolant option be considered in the design of the Advanced MAPLE reactor. (L.L.) 9 refs., 4 figs., tab.
This is the final report of a three-year, Laboratory Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). The authors investigated the evolution and radiation characteristics of individual neutron stars and stellar systems. The work concentrated on phenomena where new techniques and observations are dramatically enlarging the understanding of stellar phenomena. Part of this project was a study of x-ray and gamma-ray emission from neutron stars and other compact objects. This effort included calculating the thermal x-ray emission from young neutron stars, deriving the radio and gamma-ray emission from active pulsars and modeling intense gamma-ray bursts in distant galaxies. They also measured periodic optical and infrared fluctuations from rotating neutron stars and search for high-energy TeV gamma rays from discrete celestial sources.
Reliable facility of cyclotron-based real time neutron radiography system has been developed and applied to some industrial components. The equipment for neutron fluoroscopy is based on a sub-compact cyclotron and a LiF/ZnS (Ag) fluorescent screen viewed by a silicon intensifier target TV camera. The real time image is monitored on a CRT, recorded with a standard video recorder and processed by a digital image processor. The effectiveness of our real time neutron radiograph has been demonstrated to be applicable to not only the dynamic observation but also the magnifying and stereoscopic observation of fluoroscopic images.
Differential cross sections for dijet photoproduction in association with a leading neutron using the reaction e{sup +}+p{yields}e{sup +}+n+jet+jet+X{sub r} have been measured with the ZEUS detector at HERA using an integrated luminosity of 6.4 pb{sup -1}. The fraction of dijet events with a leading neutron in the final state was studied as a function of the jet kinematic variables. The cross sections were measured for jet transverse energies E{sub T}{sup jet}>6 GeV, neutron energy E{sub n}>400 GeV, and neutron production angle {theta}{sub n}<0.8 mrad. The data are broadly consistent with factorization of the lepton and hadron vertices and with a simple one-pion-exchange model.
The ground state masses of thirty-nine neutron-rich nuclei from [sup 51]Ca to [sup 72]Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of [sup 68]Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.)
The ground state masses of thirty-nine neutron-rich nuclei from "5"1Ca to "7"2Ni have been measured using the Time-of-Flight Isochronous (TOFI) spectrometer. Eight of these masses have been measured for the first time and thirty-one are remeasurements of neutron-rich nuclei previously reported. Good agreement between these results and a previous TOFI experiment was observed except for the most neutron-rich isotopes of vanadium through iron with the present results being more bound and in better agreement with theory. The low binding energy of "6"8Ni, as indicated by an unreasonably low two-neutron separation energy, suggests the presence of a high-lying, long-lived isomeric state in this nucleus. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd{sub 3}) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
Visualization of a liquid metal flow and image processing methods to measure the vector field are carried out by real-time neutron radiography. The JRR-3M real-time thermal neutron radiography facility in the Japan Atomic Energy Research Institute was used. Lead-bismuth eutectic was used as a working fluid. Particles made from a gold-cadmium intermetallic compound (AuCd_3) were used as the tracer for the visualization. The flow vector field was obtained by image processing methods. It was shown that the liquid metal flow vector field was obtainable by real-time neutron radiography when the attenuation of neutron rays due to the liquid metal was less than l/e and the particle size of the tracer was larger than one image element size digitized for the image processing. (orig.).
The proton and neutron densities, root-mean-square (rms) radii of proton density and neutron density, and neutron skin thickness of "4"-"1"0He, "6"-"1"1Li, and "7"-"1"2Be isotopes are calculated using Skyrme-Hartree-Fock method with SLy4, SLy5, SLy6, and SLy7 force parameters. The evaluated results are compared with experimental data. Also, the results of halo nuclei ("6","8He, "1"1Li, and "1"1Be) are compared with the results of other isotopes for selected nuclei having the same neutron configuration.
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
A number of concrete culverts used to retrievably store drummed, dry, radioactive waste at the Savannah River Site (SRS), were suspected of containing ambiguous quantities of transuranic (TRU) nuclides. These culverts were assayed in place for Pu-239 content using thermal and fast neutron counting techniques. High resolution gamma-ray spectroscopy on 17 culverts, having neutron emission rates several times higher than expected, showed characteristic gamma-ray signatures of neutron emitters other than Pu-239 (e.g., Pu-238, Pu/Be, or Am/Be neutron sources). This study confirmed the Pu-239 content of the culverts with anomalous neutron rates and established limits on the Pu-239 mass in each of the 17 suspect culverts by in-field, non-intrusive gamma-ray measurements.
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization ...
Thermal hydraulics of a liquid metal is important to design the blanket of a magnetic confined fusion reactor. Since a liquid metal has high thermal and electrical conductivity, the flow characteristics are often different from those of an ordinary liquid like water especially in thermal convection and under a magnetic field. It is difficult to simulate such flows in a liquid metal cooled blanket by water. Flow visualization is a popular method to study thermal hydraulics. Since most of metals are visible by neutron rays, neutron radiography is available to the flow visualization of a liquid metal. The purpose of this study is to develop a visualization technique of the flow in a liquid metal by real-time neutron radiography using the tracer and the dye injection methods. A real-time thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute was used for the visualization ...
The effect of both dopant and neutron radiation on the optical and thermal properties of polyvinyl chloride (PVC) has been studied. The doped samples with Pb and Cd were irradiated with a 14 MeV-neutron fluence in the range 7-28.8 x 10"9 n/cm"2. The optical energy gap E_o_p exhibits a significant dependence on the type of additive and the neutron irradiation fluence. The specific heat at constant pressure C_p showed a nonmonotonical change with radiation fluence. The results of this study show that PVC:Pb behaves as a crystalline structure which is only slightly affected by neutron irradiation, while PVC:Cd is highly affected. (author).
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
This paper describes an electronic imaging system for producing real time neutron radiography from a low power research reactor, which will allow inspections of samples with high efficiency, in terms of measuring time and result analysis. This system has been implanted because of its potential use in various scientific and industrial areas where neutron radiography with photographic film could not be applied. This real time system is installed in neutron radiography facility of Argonauta nuclear research reactor, at the Instituto de Engenharia Nuclear of the Comissao Nacional de Energia Nuclear, in Brazil. It is adequate to perform real time neutron radiography of static and dynamic events of samples.
To investigate the characteristics of a reactor and a neutron generator, a small scintillation detector with an optical fiber with ThO_2 has been developed to measure fast neutrons. However, experimental facilities where "2"3"2Th can be used are limited by regulations, and S/N ratio is low because the background counts of this detector are increase by alpha decay of "2"3"2Th. The purpose of this study is to develop a new optical fiber detector for measuring fast neutrons that does not use nuclear material such as "2"3"2Th. From the measured and calculated results, the new optical fiber detector which uses ZnS(Ag) as a converter material together with a scintillator have the highest detection efficiency among several developed detectors. It is applied for the measurement of reaction rates generated from fast neutrons; furthermore, the absolute detection efficiency of this detector was obtained ...
Perfect single-crystal neutron interferometers are adversely sensitive to environmental disturbances, particularly mechanical vibrations. The sensitivity to vibrations results from the slow velocity of thermal neutrons and the long measurement time that are encountered in a typical experiment. Consequently, to achieve a good interference solutions for reducing vibration other than those normally used in optical experiments must be explored. Here we introduce a geometry for a neutron interferometer that is less sensitive to low-frequency vibrations. This design may be compared with both dynamical decoupling methods and decoherence-free subspaces that are described in quantum information processing. By removing the need for bulky vibration isolation setups, this design will make it easier to adopt neutron interferometry to a wide range of applications and increase its sensitivity.
Using indigenously developed computer program, coupled neutron gamma multi-group libraries have been generated from MA TXS-NJOY files. The MATXS format contains all the details for each reaction. Temperature and dilution factor dependent cross-sections have been generated and used in discrete ordinates method for benchmark studies of fast critical experiments. We have analyzed criticality benchmarks, which includes CSEWG fast critical benchmarks, "2"3"3U and Pu spheres and enriched uranium spheres using 30-group neutron cross-sections. Neutron and gamma spectra for spheres with point neutron source at the center, are also calculated with 42-group coupled neutron gamma cross-sections. (author)
The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x10{sup 19} n {omega} cm{sup -1}. The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual {sup 32}P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neutron transmutation doping of the initially p-type silicon ingot was established.
The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x1019 n ? cm-1. The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual 32P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neutron transmutation doping of the initially p-type silicon ingot was established.
The Advanced Neutron Source will be a new world-class facility for research using hot, thermal, cold, and ultra-cold neutrons. The heart of the facility will be a 330-MW (fission), heavy-water cooled and heavy-water moderated reactor. The reactor will be housed in a central reactor building, with supporting equipment located in an adjoining reactor support building. An array of cold neutron guides will fan out into a large guide hall, housing about 30 neutron research stations. Appropriate office, laboratory, and shop facilities will be included to provide a complete facility for users. The ANS is scheduled to begin operation at the Oak Ridge National Laboratory early in the next decade. This PDR document defines the plant-level requirements for the design, construction, and operation of ANS. It also defines and provides input to the individual System Design Description (SDD) documents. Together, this ...
Both travelers were members of a nine-person US delegation that participated in an international workshop on accelerator-based 14 MeV neutron sources for fusion materials research hosted by the University of Tokyo. Presentations made at the workshop reviewed the technology developed by the FMIT Project, advances in accelerator technology, and proposed concepts for neutron sources. One traveler then participated in the initial meeting of the IEA Working Group on High Energy, High Flux Neutron Sources in which efforts were begun to evaluate and compare proposed neutron sources; the Fourth FFTF/MOTA Experimenters' Workshop which covered planning and coordination of the US-Japan collaboration using the FFTF reactor to irradiate fusion reactor materials; and held discussions with several JAERI personnel on the US-Japan collaboration on fusion reactor materials.
A 2.45 MeV neutron time-of-flight spectrometer was designed and built for measurements of neutron energy spectra from the JT-60U Tokamak. The spectrometer consists of two fast plastic scintillators (50 cm{sup 2} and 1800 cm{sup 2}, thickness: 2 cm) where each detector is located on two constant time-of-flight spheres. The time-of-flight spheres have radius of 1 m which gives a neutron flight length of {approx}164 cm and a time-of-flight of {approx}92 ns for 2.45 MeV source neutrons. The calculated spectrometer efficiency and resolution are 2.8 x 10{sup -2} cm{sup 2} and 105 keV (4.3%), respectively. The energy resolution corresponds to a time resolution of 2.0 ns. The spectrometer will measure neutrons in a vertical line-of-sight, {approx}9 m from the plasma center. For a total neutron emission of 10{sup 16} n/s, the countrate in the first scattering detector, ...
Prompt fission neutron energy spectra for "2"3"5U and "2"3"9Pu have been measured for fission neutron energies greater than the energy of the incident neutrons inducing fission. The measurements were undertaken to investigate the shape dependence of the fission neutron spectra upon both the incident neutron energy and the mass of the nucleus undergoing fission. Measurements were made for both nuclides at incident neutron energies of 0.50, 1.50, 2.50 and 3.50 MeV. The data are presented either as relative yields or as ratios of measured spectra to that of "2"3"5U at 0.50 MeV. Incident neutrons were produced by the "7Li(p,n)"7Be reaction using a pulsed, bunched proton beam from the 5.5 MV Van de Graaff accelerator at the University of Massachusetts Lowell Radiation Laboratory. Fission neutrons were detected by a thin ...
Full text: Semiconductor detectors coated with boron or lithium compounds have been studied for neutron detection for decades but, until recently, have been limited to thermal neutron detection efficiencies of less than 5%. We reported previously on development and simulation studies of perforated detectors whose perforations are filled with neutron-reactive material in order to produce higher detection efficiencies. Incorporation of bare and cadmium-backed detectors into battery-powered devices with low-power electronics enables us to produce compact personal neutron dosimeters that provide LED readout of counts, which can be related approximately to neutron dose. We report here on experimental studies with such compact devices; devices capable of direct readout in dose units are anticipated. The thermal and epithermal neutron flux densities from the tangential ...
Prompt fission neutron spectrum measurements at the University of Massachusetts Lowell 5.5 MV Van de Graaff accelerator laboratory require that the neutron detector efficiency be well known over a neutron energy range of 100 keV to 20 MeV. The efficiency of the detector, has been determined for energies greater than 5.0 MeV using the Weapons Neutron Research (WNR) white neutron source at the Los Alamos Meson Physics Facility (LAMPF) in a pulsed beam, time-of-flight (TOF) experiment. Carbon matched polyethylene and graphite scatterers were used to obtain a hydrogen spectrum. The detector efficiency was determined using the well known H(n,n) scattering cross section. Results are compared to the detector efficiency calculation program SCINFUL available from the Radiation Shielding Information Center at Oak Ridge National Laboratory.
Plutonium metal is produced by reducing PuF{sub 4} prepared from PuO{sub 2} by fluorination. Both fluorination and reduction are batch processes at the Los Alamos Plutonium Facility. The conversion of plutonium oxide to fluoride greatly increases the neutron yield, a result of the high cross section for alpha-neutron ({alpha},n) reactions on fluorine targets compared to the (more than 100 times) smaller {alpha},n yield on oxygen targets. Because of the increase, total neutron counting can be used to monitor the conversion process. This monitoring ability can lead to an improved metal product, reduced scrap for recycle, waste reduction, minimized reagent usage, and reduce personnel radiation exposures. A new stirred-bed fluorination process has been developed simultaneously with a recent evaluation of an automated neutron-counting instrument for quantitative process monitoring. ...
A real-time neutron radiography system was installed at the neutron radiography facility of Sumitomo Heavy Industries where a sub-compact cyclotron is used as a neutron generator and nominal neutron flux was observed as 1.1 x 10"6 n/cm"2/sec. Preliminary tests were made for various kinds of such components as collimators, scintillators, cameras and lenses and the system was chosen to give the highest quality images. Especially for the scintillator screen, screening tests were carried out for compounds of LiF/ZnS(Ag) and Gd_2O_3/ZnS(Ag) by radiographic film method. The neutron radiography image was converted to fluorescent images by means of the converter and observed by a SIT type TV camera. The video signal was directly displayed on a CRT or after processed with digital image processing devices. The characteristics of this system as for the resultant resolution are presented ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
Several configurations of moderating and shielding materials have been designed and measured on the LVR-15 reactor for boron neutron capture therapy (BNCT) purposes. To determine the neutron and gamma ray space-energy distributions in the cylindrical geometry, the two-dimensional code DOT with the coupled neutron-gamma data library DLC-36 was used. The experimental verification of the beam parameters was performed in the LVR-15 reactor thermal column empty space with layers of graphite, aluminium, alumina, lead and bismuth. Attention was paid to establishing techniques and instrumentation for monitoring the neutron and gamma ray dose and beam quality. The thermal and epithermal flux densities were measured by activation foils, the neutron spectrum was determined with a Bonner spectrometer and gamma ray background with a scintillation spectrometer. The distribution of thermal ...
An experimental study of the {sup 241}Am incineration in a high-intensity thermal neutron flux was carried out at the high-flux reactor of the Institut Laue-Langevin in Grenoble. The combination of nuclear {gamma}-ray spectroscopy and off-line mass spectrometry methods made possible the measurement of several parameters of the transmutation chain and the first experimental determination of the unknown {sup 242gs}Am thermal neutron capture cross section, which plays an essential role in the {sup 241}Am incineration process. During a 19 days irradiation in a thermal neutron flux of 5.6x10{sup 14} n/(s cm{sup 2}), (46{+-}5)% of the initial {sup 241}Am was transmuted by neutron capture of which (22{+-}8)% was incinerated by nuclear fission. A value of the thermal neutron cross section of {sup 242gs}Am(n,{gamma}) of (330{+-}50) barns was obtained. We show that this keeps the option open ...
This report describes a neutron fluence assessment performed for the Kori Unit 3 pressure vessel beltline region based on the guidance specified in Regulatory Guide 1.190. In this assessment, maximum fast neutron exposures expressed in terms of fast neutron fluence (E>1MeV) and iron atom displacements (dpa) were established for the beltline region of the pressure vessel. After Cycle 16 of reactor operation, 2nd Ex-Vessel Neutron Dosimetry Program was instituted at Kori Unit 3 to provide continuous monitoring of the beltline region of the reactor vessel. The use of the Ex-Vessel Neutron Dosimetry Program coupled with available surveillance capsule measurements provides a plant specific data base that enables the evaluation of the vessel exposure and the uncertainty associated with that exposure over the service life of the unit. Ex-Vessel ...
Employing a recently developed Monte-Carlo model, we study the fission of 240Pu induced by neutrons with energies from thermal to just below the threshold for second chance fission. Current measurements of the mean number of prompt neutrons emitted in fission, together with less accurate measurements of the neutron energy spectra, place remarkably fine constraints on predictions of microscopic calculations. In particular, the total excitation energy of the nascent fragments must be specified to within 1MeV to avoid disagreement with measurements of the mean neutron multiplicity. The combination of the Monte-Carlo fission model with a statistical likelihood analysis also presents a powerful tool for the evaluation of fission neutron data. Of particular importance is the fission spectrum, which plays a key role in determining reactor ...
Neutron radiography has been put to practical use in foreign countries as one of nondestructive inspection technologies, but in Japan, its application to other scientific fields is mainly researched. The reason is, the neutron radiography apparatuses installed in Japan are hard to be industrially utilized for a number of reasons, but also the characteristics of neutron radiography are not clearly established, and it is not standardized. The part from a collimator through an object to a detector is called ``upstream``, the part of an image detector is called ``midstream``, and the part of image processing is called ``downstream``. The nonparallel property of beam, image distortion and the lack of sharpness, beam quality and the interaction of neutron beam with an object are discussed about the upstream. The intensity of neutron beam, the energy spectra, the effective total ...
The system of the early forecast of radiation hazardous fluxes of solar cosmic rays in space on the basis of the real time neutron monitors data obtained by the NMDB (Neutron Monitor Data Base) network is created. The forecast system is based on a short cut technique of definition of a spectrum of solar protons from the data of the limited number of neutron monitor stations and with a simplified procedure of accounts. It is shown that the results of computations of solar proton spectra with the short-cut technique little differ from spectra obtained with a complete technique at energies less than 5 GeV. Thus the good agreement between derived from the neutron monitor data intensities of solar protons in an energy range of hundreds MeV with the data of direct measurements of solar protons at GOES-11 spacecraft is observed. The maximum of increase on neutron monitors outstrips on ...
In many experiments involving fast neutrons generated in nuclear reactions initiated by accelerator produced charged particle beams, it is important to be able to determine accurately the neutron yield from the target. A detector suitable for such applications should have: a constant efficiency over a large energy range; a fast time response; and the ability to discriminate between gamma rays and neutrons. The authors have constructed a open-quotes black neutron detectorclose quotes based on the design of Poenitz that has these characteristics. At the Lowell Van de Graaff accelerator laboratory neutrons are produced via the "7Li(p,n)"7Be reaction using a pulsed proton beam which impinges on metallic lithium targets. The pulsed beam enables the detector to be used in a time-of-flight spectrometer. Use of BC501 liquid scintillator permits neutron-gamma ...
The neutron capture cross sections of the stable molybdenum isotopes have been measured with high energy resolution (#DELTA#E/E < approximately 0.2%), between 3 and 90 keV neutron energy, at the 40 m station of ORELA. Average resonance parameters are extracted for s- and p-wave resonances. The s-wave neutron strength function is close to 0.5x10"-"4 for all isotopes, but the p-wave strength function exhibits a well defined peak near A approximately 95. Both s- and p-wave radiative widths decrease markedly as further neutrons are added to the closed shell. The p-wave radiative widths are generally greater than the s-wave widths showing the presence of non-statistical #gamma#-decay mechanisms. Valence neutron theory fails to explain the magnitude of the p- to s-wave radiative width disparity and doorway state processes are invoked. In particular, the data for "9"8Mo appear to ...
In 1959 Zeldovich pointed out to the possibility of storage in a closed vessel of very slow neutrons with energies below less than or equal to 10"-"7 eV noting that one may achieve the storage time up to the lifetime of a free neutron before #beta#-decay (approx.10"3 sec). This possibility is due to the effective repulsing potential which describes the interaction of slow neutrons with many substances employing a strong suppression of inelastic processes in the reflection of ultracold neutrons (UCN). In a series of experiments beginning 1968 the effective methods were developed of obtaining pure UCN beams from the maxwellian spectrum of thermal neutrons. The UCN beams of intensity about 10"3 n/sec and density up to 10"2 n/liter were obtained at the reactors with thermal neutron flux of 5 x 10"1"3 n/cm"2 sec. Such UCN beam parameters allow to measure easily the ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are ...
A real-time neutron radiography imaging system has been installed at the Texas A and M University Nuclear Science Center. The system employs a scintillating screen viewed by a low-light TV camera with a front surface mirror placed at 45deg to the neutron beam. The key components of the system are the neutron camera and the image capture and processing unit. The neutron camera uses an NE 426 scintillating screen (ZnS), front surface mirror, remote focus and zoom lens, intensified relay optics (IRO) and monochrome CCD television camera. The image capture and processing unit consists of an IBM PC AT-compatible computer, arithmetic frame grabber, frame processor and high-resolution color monitor. The neutron camera is similar to others using a silicon intensified target (SIT) television camera to provide a TV image of the low-level light from a NE 426 screen. The IRO and CCD camera are ...
Two neutron emesis experiments were conducted at the Armed Forces Radiobiology Research Institute (AFRRI). In both experiments (described as Phase I and Phase II) the radiation dose required to cause emesis in 50% of subjects (ED50) was determined for both neutron reactor and gamma reactor source radiation. Emesis onset, offset and duration times post-exposure are reported. Neutrons were maximized from the reactor by passing the beam through a 15.25 cm (6 in.) thick lead wall to filter out gamma photons. Gamma rays were maximized by thermalizing neutrons in 30.5 cm (12 in.) of water, then absorbing the thermal neutrons in a gadolinium-cadmium shield. In Phase I, 28 dogs were exposed to radiation: 12 were exposed to gamma photons at the rate of 0.69 Gy/min and 16 were exposed to neutrons at 1.2 Gy/min. In Phase II, 58 dogs in 3 groups were exposed to radiation: ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers ...
High energy physics facilities must monitor the radiation doses received by their personnel. This monitoring can only be effective if the radiation detection devices can be calibrated with a good degree of accuracy. Radiation fields are usually composed of several types of radiation, including gamma rays, beta radiation, neutrons, etc. The neutron detection instruments respond not only to the neutrons coming directly from the source but also those scattered from the floor, walls, and ceiling. The amount of neutron scattering varies from site to site depending on the construction materials and layout of the building. The purpose of this study was to determine the scattered neutron fraction in the central volume of the calibration mezzanine of the Radiation Physics Calibration Facility (RPCF) at the Fermi National Accelerator Laboratory (Fermilab). At Fermilab, radiation workers ...
We have updeated the radiological dose assessment for Enjebi Island at Enewetak Atoll using data derived from analysis of food crops grown on Enjebi. This is a much more precise assessment of potential doses to people resettling Enjebi Island than the 1980 assessment in which there were no data available from food crops on Enjebi. Details of the methods and data used to evaluate each exposure pathway are presented. The terrestrial food chain is the most significant potential exposure pathway and /sup 137/Cs is the radionuclide responsible for most of the estimated dose over the next 50 y. The doses are calculated assuming a resettlement date of 1990. The average wholebody maximum annual estimated dose equivalent derived using our diet model is 166 mremy;the effective dose equivalent is 169 mremy. The estimated 30-, 50-, and 70-y integral whole-body dose equivalents are 3.5 rem, 5.1 rem, and 6.2 rem, respectively. ...
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously ...
Collective dose equivalent and population dose from occupational exposures in Japan, 1988 were estimated on the basis of a nationwide survey. The survey was conducted on annual collective dose equivalents by sex, age group and type of radiation work for about 0.21 million workers except for the workers in nuclear power stations. The data on the workers in nuclear power stations were obtained from the official report of the Japan Nuclear Safety Commission. The total number of workers including nuclear power stations was estimated to be about 0.26 million. Radiation works were subdivided as follows: medical works including dental; non-atomic energy industry; research and education; atomic energy industry and nuclear power station. For the determination of effective dose equivalent and population dose, organ or tissue doses were measured with a phantom experiment. The resultant doses were compared with the doses previously ...
Concerning the transient phenomenon of solid-gas two-phase flow, an attempt was made to visualize and measure a flow phenomenon in which three-dimensional bubbles occurred, grew and collapsed in the vicinity of a gas injection nozzle while solid particles were circulating. Such a phenomenon could not or hardly be visualized and measured by conventional methods. Such two-phase flow was visualized using neutron radiography, its characteristics measured and the usefulness of the visualization by neutron radiography confirmed. For this purpose, three-dimensional fluidized bed vessels, rectangular or cylindrical-shaped, made of steel or aluminum sheet, were prepared. Polyethylene or glass beads were used as solid particles and activated carbon particles as the tracer. In the experiment, nitrogen gas was blown into the vessel from one nozzle and distributors provided at the bottom of the vessel and exhausted from the top via the exhaust valve, by ...
In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ({sup 241}Am, {sup 242}Am, {sup 242}Pu, {sup 237}Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess ...
In the framework of nuclear waste transmutation studies, the Mini-INCA project has been initiated at CEA/DSM with objectives to determine optimal conditions for transmutation and incineration of minor actinides (MA) in high intensity neutron fluxes. Our experimental tools based on alpha- and gamma-spectroscopy of the samples and the development of micro fission chambers could gather either microscopic information on nuclear reactions (total or partial cross sections for neutron capture and/or fission reactions) or macroscopic information on transmutation and incineration potentials. Neutron capture cross sections of selected actinides ("2"4"1Am, "2"4"2Am, "2"4"2Pu, "2"3"7Np) have already been measured at ILL, showing some discrepancies when compared to evaluated data libraries but in overall good agreement with recent data. The studies and possibilities offer by the MEGAPIE project to assess neutronic ...
Electron and ion beam dynamics of the PF-1000 facility were investigated for the first time at its upper energy limit (?1 MJ) in relation to neutron emission, the pinch's plasma ('target') characteristics and some other parameters with the help of a number of diagnostics with ns temporal resolution. Special attention was paid to the temporal and the spatial cross correlations of different phenomena. Results of these experiments are in favour of a neutron emission model based on ion beam-plasma interaction with three important features: (1) the plasma target is hot and confined during a few 'inertial confinement times'; (2) the ions of the main part of the beam are magnetized and entrapped around the pinch plasma target for a period longer than the characteristic time of the plasma inductive storage system and (3) ion-ion collisions (both fusion collisions, due to head-on impacts and Coulomb collisions) are responsible for ...
We report the results of the DC magnetization, neutron powder diffraction and neutron depolarization studies on the spin-chain compounds Ca3Co2-xFexO6 (x = 0, 0.1, 0.2 and 0.4). Rietveld refinement of neutron powder diffraction patterns at room temperature confirms the single-phase formation for all the compounds in rhombohedral structure with space group R3-barc. Rietveld refinement also confirms that Fe was doped at the trigonal prism site, 6a (0, 0, 1/4) of Co. The high temperature magnetic susceptibility obeys the Curie-Weiss law; the value of the paramagnetic Curie temperature (?p) decreases as the concentration of iron increases and it becomes negative for x = 0.4. No extra Bragg peak as well as no observable enhancement in the intensity of the fundamental (nuclear) Bragg peaks has been observed in the neutron diffraction patterns down to 30 K. No depolarization of neutron ...
The electromagnetic field due to an air explosion is here studied: neutron and the gamma-rays, generated by neutronic reactions, deposit energy which ionizes atmosphere; recoil electrons are also created by gamma collisions. This data set allows to solve the Maxwell equations which manage the electromagnetic field. The TRIPOLI-2 code studies the coupled neutron-gamma transport in 3D- geometries by the Monte Carlo method. The code has been modified to calculate the photon energy deposited in matter and the recoil electron current created by Compton effect. The method is tested wiht a simple case; then neutron and gamma transport is studied in air kerma, deposited photon energy, electron current are calculated as functions of space and time and the contributions of the different neutronic reactions are separately evaluated. The calculations presented here are only part of studies ...
In the High Flux Reactor (HFR) at Grenoble a new horizontally arranged cold neutron source will be installed that uses liquid deuterium (D_2) as the moderator for cold neutrons. This cold source should provide a high neutron flux, it should be simple in design, and be characterized by high reliability and by safe operation. A high neutron flux calls for installation of the cold source near the HFR core and good moderation requires a D_2 volume of #DELTA#5 litres. Hence, the moderator, contained in a horizontally arranged cylindrical cell of 21 cm diameter and 20 cm length, is installed at the end nearest to the core of a horizontal beam tube of roughly 4.5 m length with an inner diameter of only 23 cm (Fig. 1). The HFR will be equipped with a second cold neutron source. The installation in the existing horizontal beam tube together with the amount of heat released determined the ...
In neutron radiography, as in other forms of NDE, it is sometimes desirable to observe dynamic events. This need has generated increased interest in real-time neutron radiography systems. As in other forms of radiography, a standard method for measuring the image forming capability of real-time systems is necessary in order to compare the various methods and systems used. A technique which has been used extensively in general photography and has been applied in the characterization of several screen-film combinations used in conventional neutron radiography is to determine the imaging system's modulation transfer function (MTF). This gives a graphical representation of the system's spatial resolution capabilities and was therefore chosen as the method for evaluation of the real-time neutron radiography facility at the University of Missouri Research Reactor (MURR). The method used was to image a ...
Because the number of neutrons and gamma rays and the energy spectrum of particles from spontaneous fission are well characterized for {sup 252}Cf, it can be used as a timed source of fission neutrons and gamma rays. The first such usage incorporated a {sup 252}Cf source into gas scintillators. This paper describes a timed source of neutrons and gamma rays made by depositing {sup 252}Cf on one electrode of a parallel plate ionization chamber that can then be used for determining detection-system characteristics. The emission time of neutrons from spontaneous fission has also been determined by recording the emission time of prompt gamma rays from a {sup 252}Cf source (not incorporated into a detector) adjacent to the surface of a solid or liquid scintillator. This well characterized source of neutrons can thus be used as a randomly pulsed source for a variety of applications. This ...
The thermal neutron column of the JRR-2 reactor was remodelled in order to install a medical irradiation facility. The design experience and the cource of this remodelling are presented. At first, the thermal neutron flux was lower than expected, and the expected radiation condition was achieved by the following improvements: (1) removal of graphite from the thermal neutron column to increase the neutron flux, (2) twice increase of bismuth shielding and the shift of its position to improve the shielding effect against gamma ray, (3) application of B{sub 4}C rubber on the both surfaces of the shielding door to suppress the secondary gamma ray generation from the structural materials, (4) LiF tiles are applied on the inner face of the neutron beam exit hole to suppress the secondary gamma ray from the beam exit, and (5) installment a cone-shape polyethylene collimator to relieve the ...
The research on the therapy of brain tumors and others by the thermal neutron irradiation using research reactors is to kill tumor cells by accumulating boron at a tumor part, and using {alpha} particles and {sup 7}Li generated by {sup 10}B(n, {alpha}){sup 7}Li reaction of thermal neutrons, which is known as boron neutron capture therapy (BNCT). In Japan Atomic Energy Research Institute, the medical irradiation facility was installed in the thermal neutron column of the JRR-2, and as of March, 1994, 22 cases of irradiation have been carried out. In order to monitor the variation of thermal neutron flux during irradiation, the real time measurement using a simultaneous monitor is carried out, but there is the variation of measured values in the Si semiconductor, p-n junction detector possibly due to its direction dependence. The experiment was carried out to quantity the direction ...
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m{sup -3}){sup -1}. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for 6-10 days, ...
Inhalation of radon and its daughter products makes the major contribution to the total exposure of the population to natural radiations. In implementing a complex ecological survey, concentrations of radon and its daughter products were measured in different regions of Russia, namely, in the St. Petersburg Region, the Central Territories and the Altay Territory. Two suitable low price versions of the dosemeters for measuring environmental radon concentrations based on track-etch and activated-charcoal detectors were used. The radon daughter product activity and the effective dose equivalents were calculated with an equilibrium factor of 0.5 and a recommended effective dose equivalent factor of 0.061 mSv (Bq m"-"3)"-"1. Indoor measurements were taken in more than 1000 dwellings and public and industrial buildings of 21 towns and villages. The track chambers were exposed for about 2-3 months and the charcoal detectors for 6-10 days, mainly ...
We use UV/optical and X-ray observations of 272 radio-quiet Type 1 AGNs and quasars to investigate the CIV Baldwin Effect (BEff). The UV/optical spectra are drawn from the Hubble Space Telescope, International Ultraviolet Explorer and Sloan Digital Sky Survey archives. The X-ray spectra are from the Chandra and XMM-Newton archives. We apply correlation and partial-correlation analyses to the equivalent widths, continuum monochromatic luminosities, and alpha_ox, which characterizes the relative X-ray to UV brightness. The equivalent width of the CIV 1549 emission line is correlated with both alpha_ox and luminosity. We find that by regressing l_UV with EW(CIV) and alpha_ox, we can obtain tighter correlations than by regressing l_UV with only EW(CIV). Both correlation and regression analyses imply that l_UV is not the only factor controlling the changes of EW(CIV); alpha_ox (or, equivalently, the soft X-ray emission) plays a ...
This study investigated the engine performance and emissions of a supercharged dual-fuel engine fueled by hydrogen-rich coke oven gas and ignited by a pilot amount of diesel fuel. The engine was tested for use as a cogeneration engine, so power output while maintaining a reasonable thermal efficiency was important. Experiments were carried out at a constant pilot injection pressure and pilot quantity for different fuel-air equivalence ratios and at various injection timings without and with exhaust gas recirculation (EGR). The experimental strategy was to optimize the injection timing to maximize engine power at different fuel-air equivalence ratios without knocking and within the limit of the maximum cylinder pressure. The engine was tested first without EGR condition up to the maximum possible fuel-air equivalence ratio of 0.65. A maximum indicated mean effective pressure (IMEP) of 1425 kPa and a thermal efficiency of 39% ...
This paper reports on an experimental investigation of premixed methane/air combustion stabilized within a reticulated partially stabilized zirconia foam burner that was performed. A flame holder was used to extend the stability range to allow a stable flame to be maintained for a variety of flow rate and equivalence ratio combinations. The stability range, temperature distributions, and emissions were examined over a range of equivalence ratios and flow rates. The flame was found to be axisymmetric for all conditions in which the reactants were sufficiently well mixed and the flow distribution was sufficiently uniform. Burning speeds were measured that were well in excess of the laminar flame speed. The axial temperature distribution (measured around the burner annulus) in the postflame zone was found to be relatively insensitive to flow rate but dependent upon the burner core length. Very low concentrations of NO_x were found for fuel/air ...
Abstract We have experimentally and theoretically investigated the equivalent magnetic noise in a magnetoelectric Metglas/ 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 laminate sensor unit by considering the constituent noise sources of dielectric loss (NDE) and DC leakage resistance (NR). In the low frequency range (f = 1 Hz), theory predicts that NR dominates the noise charge (1.6 times larger than NDE), with a 1 Hz noise of 9.1\\;{\\rm pt}/\\sqrt {\\rm Hz}. The experimental equivalent magnetic noise was 10.8\\;{\\rm pt}/\\sqrt {\\rm Hz}. This observed value is slightly higher than the predicted one, which might be due to an oversimplification of the theoretical model in terms of electrical charge amplifier and external vibration noise sources. ( 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim)
The objective of this project were to investigate the dynamic behavior of peat and to evaluate the influence of that behavior on the dynamic response of peat deposits. During the course of the research, the objectives were expanded to explore the effects of strong earthquake shaking on pile foundations embedded in peat deposits. An experimental investigation was undertaken using samples of a peat deposit typical of many large peat deposits in western Washington. A series of ground response analyses was performed to investigate the seismic response of peat deposits. Three vertical profiles through Mercer Slough were analyzed using both equivalent linear and nonlinear ground response analyses. The analyses showed that the soft nature of the Mercer Slough peat would produce amplification of the long-period components of an earthquake ground motion. Comparison of the equivalent linear and nonlinear ground response analyses showed that the ...
The isomeric and {beta}-decay properties of neutron-rich {sup 53-57}Sc and {sup 53,54}Ca nuclei near neutron number N = 32 are reported, and the low-energy level schemes of {sup 53,54,56}Sc and {sup 53-57}Ti are presented. The low-energy level structures of the {sub 21}Sc isotopes are discussed in terms of the coupling of the valence 1f{sub 7/2} proton to states in the corresponding {sub 20}Ca cores. Implications with respect to the robustness of the N = 32 subshell closure are discussed, as well as the repercussions for a possible N = 34 subshell closure.
Amongst the minor actinides issued from the spent nuclear fuel, {sup 241}Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of {sup 241}Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the {sup 242gs}Am neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.
Amongst the minor actinides issued from the spent nuclear fuel, "2"4"1Am is present in high concentration and contributes significantly to the long-term radiotoxicity of nuclear waste. A major uncertainty was present in the transmutation chain of "2"4"1Am when irradiated by a high intensity thermal neutron flux. This uncertainty was brought about by the poor knowledge of the "2"4"2"g"sAm neutron capture cross section. A dedicated experiment has been performed at the Institut Laue-Langevin in Grenoble, which gives a definitive experimental answer to this problem.
The conceptual design of an ohmically heated, reversed-field pinch (RFP) operating at /approximately/5-MW/m/sup 2/ steady-state DT fusion neutron wall loading and /approximately/124-MW total fusion power is presented. These results are useful in projecting the development of a cost effective, low input power (/approximately/206 MW) source of DT neutrons for large-volume (/approximately/10 m/sup 3/), high-fluence (3.4 MW yr/m/sup 2/) fusion nuclear materials and technology testing. 19 refs., 15 figs., 9 tabs.
A calorimetric-time-of-flight (CTOF) technique was used for real-time, high-precision measurement of neutron spectrum at the angle of 175 degrees from the initial proton beam direction, which hits a face plane of a cylindrical iron target of 20 cm in diameter and 25 cm thick. A comparison was performed between the neutron spectra predicted by the MARS and the MCNPX code systems and measured by experiments for 0.4-, 0.6-, 0.8-, 1.0-, and 1.2-GeV protons.
The effect of high energy neutron irradiation (E > 1MeV) on the superconducting transition temperature, Tsub(c), of the A-15 compound Mo_3Os is reported. Tsub(c) was found to decrease with increasing neutron dose, but at a rate considerably less than observed in other A-15 compounds composed of non-transition metals. The results lend support to the idea that the effect of ordering on Tsub(c) is smaller for A-15 compounds composed only of transition metals than those composed of transition and non-transition metals. (author).
With 13 experimental facilities under construction to become available during the first year of SINQ operation, a nearly complete suite of options for users will be made available to carry out research with neutrons at PSI. Three more facilities are under design and will come on line somewhat later. To complete the suite, three more specialized instruments are being evaluated. SINQ being a novel neutron source concept, significant scope for improvement is also seen on the source side. It is a major goal of PSI to exploit these opportunities and to make - among others - use of neutron instruments to carry out the necessary research. (author) 9 figs., 1 tab., 11 refs.
We have measured the neutron capture and fission cross section of "2"3"3U at the neutron time-of-flight facility n-TOF at CERN in the energy range from 1 eV to 1MeV with high accuracy by using a high performance 4#pi# BaF_2 Total Absorption Calorimeter (TAC) as a detection device. The method, based on the shape analysis of the TAC energy response, allowing to disentangle between #gamma#'s originating from fission and capture will be presented as well as the first very preliminary results. (authors)
This paper discusses the stationary neutron radiography system (SNRS) with respect to the component positioning systems (CPSs) and the rationale behind their design. As design work is on-going at science Applications International Corporation, this report gives a current update of progress. The SNRS has four separate radiography bays, Bays 1 through 4. The first three bays have automated positioning systems for real-time and near real-time neutron radiography of aircraft components. Bay 4 has been designed to accommodate components from the solid rocket booster, but will be used first for film radiography of pyrotechnic components.
Subcritical source-driven noise measurements are simultaneous Rossia and randomly pulsed neutron measurements that provide measured quantities that can be related to the subcritical neutron multiplication factor. In fact, subcritical source-driven noise measurements should be performed in lieu of Rossia measurements because of the additional information that is obtained from noise measurements such as the spectral ratio and the coherence functions. The basic understanding of source-driven noise analysis measurements can be developed from a point reactor kinetics model to demonstrate how the measured quantities relate to the subcritical neutron multiplication factor.
The improved facilities of the ISOLDE isotopic separator on-line with the 600 MeV synchrocyclotron at CERN opened the possibility to reach nuclei very far from stability (as far as 22 neutrons deficient in the Cs region and 27 neutrons deficient in the Hg region). Simultaneously the development of on-line spectrometry allowed the study of nuclei with very short half-lives and low counting rates. Results recently obtained in the odd-A iridium region are presented after a short summary of recent on-line devices developments and results. (Auth.).
The McMaster Neutron Radiography Facility (MNRF) is fortunate to own the only Real-Time Neutron Radiography system in Canada. Current research at the MNRF involves the visualization of gas-liquid and gas-solid two-phase flow in complex channels, such as nuclear fuel channels, using light water, heavy water, freon-134A, slurries, and other fluids. Other research at the MNRF has examined single-phase flow, material purity, film deposition, turbine blades, and automotive parts.
The response of a real time neutron dosemeter using a thin LiF target sandwiched between tow parallel surface barrier semiconductor detectors is studied for different neutron distributions and different angles of incidence. Calculations of the response function defined for a simultaneous detection by the two detectors of the particles emitted when the reaction "6Li(n,t)#alpha# occurs in the target are fulfilled by geometrical considerations of the reaction kinematics and the differential cross section variations. Finally, the efficiency of the studied detection systems is analyzed for dosimetric uses. (author).
Some results on mechanical property study of copper and titanium subjected to impact load and next to neutron irradiation are presented. It was shown that shock wave influence involves a substantial shape change of the stress-strain diagram and of respective mechanical characteristics. Yield- and ultimate strength were substantially increased, as well as hardness with a considerable drop of plasticity. Also a heat stability of copper and titanium specimens was studied after being treated with shock-waves and neutron radiation. Results are given of electron microscope study of titanium structure sfter explosion hardening, which caused decomposition of hydride segregations in titanium and increased dislocation density.
The #gamma#-radiation following thermal neutron capture in "1"0"0Mo has been studied by singles and coincidence measurements. A "1"0"1Mo level scheme has been deduced and is compared with the results of previous (d,p), (n,#gamma#) and "1"0"1Nb decay studies. The existence of the first excited state at 13.51 keV has been confirmed. The present data yield a neutron binding energy of 5398.4 KeV. (Auth.).
A thermal neutron imaging facility for real-time neutron radiography and computed tomography has been developed at the University of Texas reactor. The facility produced good-quality radiographs and two-dimensional tomograms. Further developments have been recently accomplished. A computer software has been developed to automate and expedite the data acquisition and reconstruction processes. Volume tomographic visualization using Interactive Data Language (IDL) software has been demonstrated and will be further developed. Volume tomography provides the additional flexibility of producing slices of the object using software and thus avoids redoing the measurements.
This report is a summary of the progress and research produced for the Idaho National Engineering and Environmental Laboratory (INEEL) Boron Neutron Capture Therapy (BNCT) Research Program for calendar year 1996. Contributions from the individual investigators about their projects are included, specifically, physics: treatment planning software, real-time neutron beam measurement dosimetry, measurement of the Finnish research reactor epithermal neutron spectrum, BNCT accelerator technology; and chemistry: analysis of biological samples and preparation of {sup 10}B enriched decaborane.
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
Epoxy-resin based neutron shielding material, NS-4-FR, is used for spent fuel transport and/or storage cask. In this paper the outline of thermal aging test performed to evaluate the heating effect on this neutron shielding material, NS-4-FR, is introduced. The test is consisted of two kinds of thermal aging test, one is 'Basic Test' and the other is 'Block Heating Test'. The former is cooperatively performed by ten Japanese Electrical Power Companies, and the latter is done by GESC and NOF Corporation. (authors)
The prompt neutron spectra of {sup 241}Am, {sup 242m}Am, and {sup 243}Am were evaluated for the next version of Japanese Evaluated Nuclear Data Library, using the methodology developed by the authors. The method is based on the Madland-Nix theory with some improvements to consider the multimodal nature of the fission process, and shell effects on the level density parameters and the neutron multiplicity from light and heavy fragments. The results were compared with previous evaluations. (authors)
Neutron deficient nuclei with mass numbers A {approx} 90 and 40 {<=} Z {<=} 44 have been studied making use of the Osiris and Nordball spectrometers. The high spin states of these nuclei and their electromagnetic decay properties are compared to shell model calculations based on the core {sup 88}Sr and using different parametrizations of the residual interaction. The dependence of the mean square deviations of experimental and theoretical level energies, branching ratios, and transition probabilities on the neutron numbers N = 46-50 and the validity of seniority as a good quantum number are discussed. (orig.).
The aim of this thesis is the study of new systems devoted to the real time neutron spectrometry and dosimetry. The microelectronics technologies have been used to research a micro system integrating sensor and data processing in real time. The multi range sensor is based on many pair of semiconductor diodes placed face to face and covered by lithium fluoride. The sensor has been designed and its behavior has been simulated. Its operating in reference neutrons beams has been analyzed. (A.L.B.)
Beta-decay studies of the new neutron-rich isotopes sup(58,59)Cr, "6"3Mn, sup(66,67)Co and "6"9Ni, yielding distinctly shorter half-lives than the corresponding theoretical predictions, are presented. The influence of the short half-lives on the r-process calculations of nuclear abundances is discussed. It is concluded that a significantly higher neutron density than the one obtained from explosive helium burning in supernovae is needed to reproduce the observed abundances around A = 80. (orig.).
A diagnosis of the refrigerant flows in a refrigerator was carried out by real-time neutron radiography. The thermal neutron radiography system of JRR-3M in Japan Atomic Energy Research Institute and the real-time image processing system developed by Musashi Institute of Technology were used. Freon evaporating flows in the evaporator, condensing flows in the condenser, flashing flows in the capillary tube and flows in the accumulator were visualized and the dynamic behaviors under practical conditions were clarified. In the case of the capillary tube of 0.8 mm i.d., a cooled-CCD camera was utilized. (orig.).
Alpha-particle emission induced by neutron bombardment of carbon has been studied from threshold to over 30 MeV using the spallation neutron source at WNR/LAMPF. Targets include thin foils of CH{sub 2} and thicker foils of CH and polycrystalline graphite. Comparisons are made with evaluated data. Values for KERMA (kinetic energy released in materials) based on the results will be presented and compared with those obtained through other experimental approaches.
The isomeric and ?-decay properties of neutron-rich 53-57Sc and 53,54Ca nuclei near neutron number N=32 are reported, and the low-energy level schemes of 53,54,56Sc and 53-57Ti are presented. The low-energy level structures of the 21Sc isotopes are discussed in terms of the coupling of the valence 1f7/2 proton to states in the corresponding 20Ca cores. Implications with respect to the robustness of the N=32 subshell closure are discussed, as well as the repercussions for a possible N=34 subshell closure.
An extensive set of benchmark measurement of PDDs and beam profiles was performed in a heterogeneous layer phantom, including a lung equivalent heterogeneity, by means of several detectors and compared against the predicted dose values by different calculation algorithms in two treatment planning systems. PDDs were measured with TLDs, plane parallel and cylindrical ionization chambers and beam profiles with films. Additionally, Monte Carlo simulations by meansof the PENELOPE code were performed. Four different field sizes (10x10, 5x5, 2x2, and1x1 cm"2) and two lung equivalent materials (CIRS, #rho#_e"w=0.195 and St. Bartholomew Hospital, London, #rho#_e"w=0.244-0.322) were studied. The performance of four correction-based algorithms and one based on convolution-superposition was analyzed. The correction-based algorithms were the Batho, the Modified Batho, and the Equivalent TAR implemented in the Cadplan (Varian) treatment ...
A real-time two-dimensional void fraction distribution measurement of gas-liquid two-phase flow was carried out by real-time neutron radiography and real-time image processing. The JRR-3M real-time thermal neutron radiography system and a Musashi dynamic image processing system were used. Image processing methods to calculate two-dimensional and cross-sectional void fraction distributions were proposed. The void fraction distribution was calculated by non-linear processing of the neutron radiography image and displayed by pseudo-color in real-time. A simple gas-liquid two-phase flow induced by injecting gas through needles at the bottom of water pool in a rectangular vessel was tested. (orig.).
The neutron capture cross-section of {sup 234}U has been measured for energies from thermal up to the keV region in the neutron time-of-flight facility n-TOF, based on a spallation source located at CERN. A 4{pi} BaF{sub 2} array composed of 40 crystals, placed at a distance of 184.9 m from the neutron source, was employed as a total absorption calorimeter (TAC) for detection of the prompt {gamma}-ray cascade from capture events in the sample. This text describes the experimental setup, all necessary steps followed during the data analysis procedure. Results are presented in the form of R-matrix resonance parameters from fits with the SAMMY code and compared to the evaluated data of Endf in the relevant energy region, indicating the good performance of the n-TOF facility and the TAC. (authors)
For the application of dynamic neutron radiography to the two-phase flow research using HANARO, several experimental items to which the radiography technique is beneficial were identified through the review of the outputs from the related researches and the discussions with experts. Also, the investigation of the equipments including the beam port, camera and converter was made and a hardware and a software for image processing were equipped. It was confirmed that the calibration curve for the attenuation of neutron beam in fluid which is required for the two-phase flow experiment could be obtained by the computer code calculation. Based on the investigation results on the equipment and the results from the measurement of BNCT beam characteristics, a high speed camera and an image intensifier will be purchased. Then, the high speed dynamic neutron radiography facility for two-phase flow experiments will be fully equipped.
The results on 5 K irradiation available so far may be summarized as follows. (1) Increases of j/sub c/ following neutron irradiation occur only in conductors which are far from the optimal metallurgical treatments. (2) The changes of j/sub c/ following neutron irradiation and a thermal cycle to room temperature are small and in most cases comparable to the results obtained after 77 K irradiation. (3) The data available so far indicate that the degradation of j/sub c/ at 8 T is larger by about 5 to 10% than the corresponding changes at 5 T at a neutron fluence of 1.3 x 10/sup 22/ m/sup -2/ (E > 0.1MeV). (4) The increase of Cu-resistivity is significant even after a thermal cycle to room temperature and requires design changes for a stable magnet operation.
Neutron Coded Aperture Imaging is a nondestructive imaging technique that utilizes neutrons scattered from an object through specially designed apertures. Coded Aperture Imaging is an alternative technique to Computed Tomography for three-dimensional imaging. Coded Aperture Imaging has the advantage that all of the three-dimensional information is contained in a single image, whereas Computed Tomography requires several images or projections. This technique has been implemented by other using photographic film as an image recording medium and optical reconstruction or decoding of the images. In this work, the possibility of using a real-time neutron video camera to record the images, followed by digital decoding methodology has been investigated. Because only a small fraction of the neutrons incident on the object are scattered to the neutron camera, a new ...
The thermal neutron capture cross sections and the neutron capture resonance integrals of {sup 241}Am leading to the production of the isomer {sup 242m}Am and the ground-state {sup 242g}Am were measured radiochemically by the Cd-ratio technique with neutron flux monitors of Co/Al and Au/Al alloy. Highly-purified {sup 241}Am targets were irradiated in an aluminum capsule by using JMTR. The neutron fluxes and their epithermal neutron fractions were determined by measuring {gamma}-rays of {sup 60}Co and {sup 198}Au. The yields of {sup 242m}Am and {sup 242g}Am were decided by analyzing growth and decay curves of the {alpha}-ray activity ratios {sup 242}Cm/{sup 241}Am. The resultant thermal neutron capture cross sections are 85.7 {+-} 6.3 b and 768 {+-} 58 b for {sup 242m}Am and {sup 242g}Am, and the resonance integrals 114 {+-} 7 b and 1,694 {+-} 146 b, ...
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., {+-}5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate ...
A computer-based beam dosimetry measurement system for boron neutron capture therapy provides accurate, sensitive, and rapid readout and recording of all beam dose components, epithermal and thermal neutron flux, and gamma-ray dose rate. This dosimetric system includes input from the characterization of the epithermal neutron beam developed at the Massachusetts Institute of Technology, actual BPA pharmacokinetic data from a specific human subject being irradiated, output of MacNCTPLAN, a treatment planning system developed by the authors group, and input from the five on-line beam detectors. The purpose of this system and associated readout systems is to ensure that the desired dose is delivered to the subject within acceptable dose tolerances, e.g., #+-#5% of the target dose, and that any perturbations in the neutron beam that may occur during irradiation can be rapidly evaluated and the appropriate ...
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
Real-time neutron radiography was demonstrated to be a viable and useful tool in studying water flow in unsaturated media. The experiment was designed to test the method for following water flow. The wetting front advance, water-flow patterns, and neutron attenuation density were observed in a 7.7-cm diameter sand column. The advance was fit with a simple i = A t/sup B/ equation yielding an excellent correlation. Theoretical calculations presented estimate the minimum and maximum detectable water content in various sizes of columns. The ability of real-time neutron radiography to allow both qualitative and quantitative spatial and time measurements to be made in an nonintrusive manner was demonstrated.
The authors have made new and improved measurements of the neutron capture and total cross sections of {sup 88}Sr at the Oak Ridge Electron Linear Accelerator (ORELA). Improvements over previous measurements include a wider incident neutron energy range, the use of metallic rather than carbonate samples, better background subtraction, reduced sensitivity to sample-dependent backgrounds, and better pulse-height weighting functions. Because of its small cross section, the {sup 88}Sr(n,{gamma}) reaction is an important bottleneck during the s-process nucleosynthesis. Hence, an accurate determination of this rate is needed to better constrain the neutron exposure in s-process models and to more fully exploit the recently discovered isotopic anomalies in certain meteorites. They describe the experimental procedures, compare the results to previous data, and discuss their astrophysical impact.
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10/sup 11/ m/(m/sup 2/-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83/sup 0/C +/- 8/sup 0/C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3/sup 0/ +/- 0.1/sup 0/ thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time ...
A real-time neutron radiography facility was constructed including the capability of neutron tomography. The neutron beam was measured for total neutron flux ((1.0 +/- 0.2) x 10"1"1 m/(m"2-sec)), gold cadmium ratio (52 +/- 3) and effective neutron temperature (83"0C +/- 8"0C). The angular divergence or nonparallelism of the neutron beam was measured to be 2.3"0 +/- 0.1"0 thereby providing a means of quantifying the collimator effectiveness. The resolution capabilities of both static film and real-time neutron radiographs were quantified using a Fourier transform algorithm to calculate the modulation transfer function of both types of radiographs. The contrast sensitivity of both types of radiographs. The contrast sensitivity of both types of radiographs was measured as 3.1% for film and 4.0% for real-time radiographs. Two tomography ...
Neutron resonance interactions with "1"0"0Mo were studied at a time-of-flight facility. The transmission of two oxide samples (97.4% "1"0"0Mo) was measured at a 78.20 m flight path and the neutron capture cross section was measured at 40.12 m. Resonance analyses yielded parameters of 124 resonances. Capture #gamma#-ray spectra from 11 resolved resonances were measured with a Ge(Li) detector at a 10.45 m flight path. In contrast to neighboring nuclei, partial radiation widths of strong p-wave resonances are not in agreement with valence model predictions.
Differential cross sections for the excitation of the first octupole-vibrational state in the closed-neutron-shell nuclides "8"8Sr and "9"0Zr and in the closed-proton shell-nuclei sup(116,118,120,124)Sn by 11 MeV neutrons are presented. The distorted-wave Born approximation is used to obtain deformation lengths, delta(3"-) for each state. Results are compared with earlier measurements of inelastic proton scattering to the same states. Although limited resolution in the neutron time-of-flight spectrometer complicates the interpretation of the Sn data, the overall conclusion that deltasub(nn')(3"-) approx. deltasub(pp')(3"-) is supported by all of the measurements. (orig.).
In 2002, an innovative neutron time-of-flight facility started operation at CERN: n_TOF. The main characteristics that make the new facility unique are the high instantaneous neutron flux, high resolution and wide energy range. Combined with state-of-the-art detectors and data acquisition system, these features have allowed to collect high accuracy neutron cross-section data on a variety of isotopes, many of which radioactive, of interest for Nuclear Astrophysics and for applications to advanced reactor technologies. A review of the most important results on capture and fission reactions obtained so far at n_TOF is presented, together with plans for new measurements related to nuclear industry.
INAA (instrumental neutron activation analysis) analyses have been made of subsamples of each OSL (Optically stimulated luminescence) sample, for dosimetry ...
Presented are the investigation results of electrophysical and physico-mechanical properties of KLF-20, Viksint U-4-21, Viksint KT-73, UF-7-21, KG-184, KL-4, KL-16SE-305, VIAT-1 and PPK-21 sealants, irradiated with sources of continuous and pulse #gamma#-radiation, as well as pulse #gamma#-neutron radiation. It is shown that electrophysical and physico-mechanical properties of sealants after irradiation by continuous #gamma#-radiation up to 10"6 doses and pulse gamma-neutron radiation with neutron fluence of 10"1"3 neutron/cm"2 and #gamma#-radiation dose of 10"4R do not practically change. Electric conductivity and tangent of the angle of dielectric losses increase in the process of irradiation. Electric conductivity depends on irradiation type, is proportional to dose rate and does not depend on temperature and pulse duration.
The aim of this work is the implantation and characterization of a neutron radiography system that uses an electronic device for attainment of images in real time, for its implementation in the nuclear research reactor Argonauta at IEN/CNEN (Nuclear Engineering Institute of the Brazilian Nuclear Energy Commission). The Electronic Imaging System in Real Time is composed by a scintillator screen for neutron, a video camera (CCD), a digital plate and a computer with specific computational programs for digital processing of the images. The System in installed real time is apt to carry through neutron radiography inspections of static and dynamic events of several types of samples. (author)
PSI has a relatively long tradition in neutron imaging since the first trials were done at its formerly existing research reactor SAPHIR with film methods. This reactor source was replaced after its shutdown in 1994 by the spallation neutron source SINQ in 1996, driven by the 590MeV cyclotron for protons with presently up to 2.3mA beam current. One of the first experimental devices at SINQ was the thermal neutron imaging facility NEUTRA, which was designed from scratch and has been the first device of its kind at a spallation source. Until now, NEUTRA has been successfully in use for many investigations in a wide range of studies covering fuel cell research, environmental behavior of plants, nuclear fuel inspection and the research on cultural heritage objects. It has been the host of PhD ...
The Helium and Lead Observatory (HALO) is a supernova neutrino detector under development for construction at SNOLAB. It is intended to fulfill a niche as a long term, low cost, high livetime, and low maintenance, dedicated supernova detector. It will be constructed from 80 tonnes of lead, from the decommissioning of the Deep River Cosmic Ray Station, and instrumented with approximately 384 meters of {sup 3}He neutron detectors from the final phase of the SNO experiment. Charged- and Neutral-Current neutrino interactions in lead expel neutrons from the lead nuclei making a burst of detected neutrons the signature for the detection of a supernova. Existing neutrino detectors are mostly of the water Cerenkov and liquid scintillator types, which are primarily sensitive to electron anti-neutrinos via charged-current interactions on the hydrogen nuclei in these materials. By contrast, the large neutron ...
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20/sup 0/ and 130/sup 0/. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron ...
Neutron time-of flight spectra were measured from 90 MeV protons and 140 MeV alpha-particle bombardment of Al, Ni, Zr, and Bi at laboratory angles between 20"0 and 130"0. The proton induced neutron spectra reveal three distinct energy regions; a low energy evaporation region, a high-energy region dominated by quasi-free scattering processes and an intermediate-energy region dominated by multi-step, pre-equilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-induced neutron spectra show these same distinct energy regions plus an exponential fall-off above the beam energy per nucleon. The high-energy portions of the forward-angle neutron and proton cross sections are in ratios consistent with the assumption that single nucleon-nucleon scattering dominates. For heavy-mass targets, the low-energy evaporation regions show neutron yields ...
We measured neutron time-of-flight spectra from 90 MeV protons and 140 MeV alpha particles bombarding thin targets of Al, Ni, Zr, and Bi at laboratory angles between 20_0 and 135_0. The low-energy (5 to 45 MeV) portions of the spectra were measured with 5 cm diameter by 5 cm deep NE-213 counters at 1 m flight paths with n-#betta# pulse-shape discrimination. The high-energy (35 to 150 MeV) portions of the spectra were measured with 12.7 cm diameter by 10.2 cm deep NE-102 counters at flight paths of 2.0 to 5.0 m. The proton-induced measured neutron spectra reveal three distinct energy regions: a low-energy evaporation region, a high-energy region dominated by the quasifree scattering process, and an intermediate-energy region dominated by multistep, preequilibrium processes. In the latter two regions, the spectra show strong angular dependence. The alpha-particle induced neutron spectra show these same distinct energy regions ...
The effect of a sawtooth crash on the radial distribution of the slowing down fusion product tritons and on beams ions, is examined with measurements of the 2.5 MeV and 14 MeV neutron emission line-integrals before and after sawtooth crashes. In deuterium discharges, the 14 MeV neutron production was wholly attributable to burnup of the 1MeV fusion product tritons from d-d fusion. The local emissivity of 14 MeV neutrons, and hence of the profile of thermalizing tritons, is shown to be only weakly affected by crashes in the discharges studied. This is in contradiction with the apparent behaviour of injected beam ions as deduced from a study of the considerable changes in local emissivity of the 2.5 MeV neutrons. Nevertheless, the behaviour of the fusion product tritons is consistent with the scaling of the beam injected deuterium. 1 ref., 6 figs.
Doubly decoupled structures in doubly odd deformed nuclei are reexamined and shown to be composed of a pseudo-spin aligned neutron and a decoupled proton. (orig.).
Doubly decoupled structures in doubly odd deformed nuclei are reexamined and shown to be composed of a pseudo-spin aligned neutron and a decoupled proton. (orig.).
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively.
Real-time neutron radiography (NTV) has been used for practical applications at the Kyoto University Reactor (KUR). At present, however, the direct image from the TV system is still poor in resolution and low in contrast. In this paper several image improvements are demonstrated, such as a frame summing technique, which are effective in increasing image quality in neutron radiography. Image integration before the A/D converter has a beneficial effect on image quality and the high quality image reveals details invisible in direct images, such as: small holes by a reversed image, defects in a neutron converter screen through a high quality image, a moving object in a contoured image, a slight difference between two low-contrast images by a subtraction technique, and so on. For the real-time application a contouring operation and an averaging approach can also be utilized effectively. (orig.).
Energy and angular double differential cross-section data of fragments by tens of MeV neutron or proton are important to evaluate dosimetry and radiation effect in devices or instruments, since fragments cause a large local ionization. Up to now, experimental data of the fragment production are very scarce due to experimental difficulties of fragment detection. A bragg curve spectrometer (BCS) for fragment measurement is a gridded-ionization chamber that identify fragments on the basis of the difference of Bragg peak value. The BCS was fabricated to adopt for fragment measurement in neutron-induced reactions and tested with a charged-particle beam and then applied to a neutron field successfully. The structure of BCS is a cylindrical gridded ionization chamber, and filled with a Ar + 10% CH{sub 4} gas at a pressure of 2.7 x 10{sup 4} Pa. To confirm the performance of BCS, the following tests were performed: 1) the ...
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid ...
Experimental investigations have been conducted to determine two-phase natural circulation interfacial parameters by real-time neutron radiography. The natural circulation loop used in the present experiments consists of a vertical two-phase section, a gas liquid separator, and a gas injection/heating section. Experiments were performed in a neutron beam for visualization using realtime neutron radiography system. The natural circulation was initiated by injection of known gas flow rate in the heated section. Two-phase flow interfacial parameters including interfacial geometry and phase velocities etc. for bubbly flow and slug flow patterns observed in the experiments will be given in detail. The results indicate that while the natural circulation is largely as expected and that steady stable flows are possible, there are some local phenomena that introduce instabilities due to the interfacial phenomena between the liquid ...
As a contribution to the US/Japan cooperative program in fusion neutronics, we have prepared a library of multigroup neutron cross sections, scattering matrices, and covariances (uncertainties and their correlations). This 74-group library, called COVFILS-2, is being used at Los Alamos and at the University of California at Los Angeles in the sensitivity and uncertainty analysis of the Li_2O integral experiment recently performed at the Fast Neutron Source (FNS) in Japan. Another intended use of this library is in the estimation of the uncertainty in key performance parameters (such as breeding ratio) of conceptual fusion reactors. The 14 materials included in the first version of COVFILS-2 are H, "6Li, "7Li, Be, C, N, O, Na, Al, Si, Cr, Fe, Ni, and Pb.
Radiation portal monitors used for interdiction of illicit materials at borders include highly sensitive neutron detection systems. The main reason for having neutron detection capability is to detect fission neutrons from plutonium. The currently deployed radiation portal monitors (RPMs) from Ludlum and Science Applications International Corporation (SAIC) use neutron detectors based upon 3He-filled gas proportional counters, which are the most common large neutron detector. There is a declining supply of 3He in the world, and thus, methods to reduce the use of this gas in RPMs with minimal changes to the current system designs and sensitivity to cargo-borne neutrons are being investigated. Four technologies have been identified as being currently commercially available, potential alternative neutron detectors to replace the use of 3He in ...
The neutron transmutation doping (NTD) method was applied to the initially p-type silicon in order to extend the NTD applications at HANARO. The relationship between the irradiation neutron fluence and the final resistivity of the initially p-type silicon material was investigated. The proportional constant between the neutron fluence and the resistivity was determined to be 2.3473x1019ncm-1. The deviation of the final resistivity from the target for almost all the irradiation results of the initially p-type silicon ingots was at a range from -5% to 2%. In addition, the burn-up effect of the boron impurities, the residual 32P activity and the effect of the compensation characteristics for the initially p-type silicon were studied. Conclusively, the practical methodology to perform the neut...
Mar 1, 2011 ... Currently there is no compact, portable and real time neutron detector instrumentation available for use inside spacecraft or on planetary ...
This paper describes activation measurements of the neutrons from fusion plasmas. We are primarily interested in two narrow bands of neutron energies around 2.5 and 14 MeV. The d-d reaction has two branches with nearly equal probability, one generating a 0.8 MeV {sup 3}He nucleus and a 2.45 MeV neutron, the other a 1MeV triton and a 3 MeV proton. The d-t fusion generates a 3.5 MeV alpha particle and a 14 MeV neutron. The triton burnup can be defined as the ratio of triton removal rate to triton generation rate. The burnup depends on how well the tritons are confined in the plasma during their slowing down to energies that make d-t fusion probable. It is important to study the tritons as they have similar kinematics to the 3.5 MeV alpha particles in a d-t plasma. Threshold reactions make a distinction between 2.5 and 14 MeV neutrons ...
Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.
Of some interest is the comparison between the actinide nuclide burning up (fission) rates such as americium 241, americium 242, curium 244, and neptunium 237, in the reactors with fast or thermal neutron spectra.
A recently developed neutron diagnostic probe system has the potential to satisfy a significant number of van-mobile and fixed- portal requirements for nondestructive verification of sealed munitions and detection of contraband explosives and drugs. The probe is based on a unique associated-particle sealed-tube neutron generator (APSTNG) that interrogates the object of interest with a low-intensity beam of 14-MeV neutrons generated from the deuterium-tritium reaction and that detects the alpha-particle associated with each neutron. Gamma-ray spectra of resulting neutron inelastic scattering and fission reactions identify nuclides associated with all major chemicals in chemical warfare agents, explosives, and drugs, as well as many pollutants and fissile and fertile special nuclear material. Flight times determined from determined from detection times of the gamma-rays and ...
The {rvec n} + p {yields} d + {gamma} experiment under construction at LANSCE studies the weak interaction between neutrons and protons. The experiments will measure the directional dependence of the parity-violating {gamma}-ray asymmetry, A{sub {gamma}}, in the polarized cold neutron capture by para-hydrogen. The goal is to measure A{sub {gamma}} with uncertainty of 0.5 x 10{sup -8}, 10% of its predicted value. A{sub {gamma}} primarily isolates the {Delta}I = 1 component of the hadronic weak interaction and thus will determine the long-range weak pion-nucleon coupling constant H{sub {pi}}{sup 1}. The experiment is carefully designed for the LANSCE pulsed spallation neutron source to achieve the proposed statistical precision and to control systematic errors. We discuss the experiment and its status.
A 16 l liquid parahydrogen target has been developed for a measurement of the parity-violating {gamma}-asymmetry in the capture of polarized cold neutrons on protons in the {rvec n} + p {yields} d + {gamma} reaction by the NPDGamma collaboration. The target system was carefully designed to meet the stringent requirements on systematic effects for the experiment and also to satisfy hydrogen safety requirements. The target was designed to preserve the neutron polarization during neutron scattering on liquid hydrogen (LH{sub 2}), optimize the statistical sensitivity to the {rvec n} + p {yields} d + {gamma} reaction, minimize backgrounds coming from neutron interaction with the beam windows of the target cryostat, minimize LH{sub 2} density fluctuations which can introduce extra noise in the gamma asymmetry signal, and control systematic effects. The target incorporates two mechanical refrigerators, two ...
High-pressure, lean, premixed methane/air flames are investigated experimentally to determine turbulent flame speeds (s{sub T}). The results are based on the statistical analysis of single-shot OH-PLIF images. The influences of pressure (p = 5 - 14.4 bars) and equivalence ratio ( {phi} 0.43 - 0.56) on the turbulent flame speed are discussed. The analysis reveals that s{sub T} is independent of pressure and it depends strongly on equivalence ratio. The turbulent flame speed at {phi} = 0.56 is about 3 times higher than at {phi} = 0.43 because of the higher integral reaction rate caused by the higher fuel concentration and therefore higher adiabatic flame temperature. (author)
A method and system for enhancing the transient stability of an intertied three-phase electric power generating system. A set of power exporting generators (10) is connected to a set of power importing generators (20). When a transient cannot be controlled by conventional stability controls, and imminent loss of synchronism is detected (such as when the equivalent rotor angle difference between the two generator sets exceeds a predetermined value, such as 150 degrees), the intertie is disconnected by circuit breakers. Then a switch (30) having a 120-degree phase rotation, or a circuit breaker having a 120-degree phase rotation is placed in the intertie. The intertie is then reconnected. This results in a 120-degree reduction in the equivalent rotor angle difference between the two generator sets, making the system more stable and allowing more time for the conventional controls to stabilize the transient.
The optical spectroscopy measurements of gadolinium gallium garnet (GGG) crystals doped with Yb show evidence of the presence of non-equivalent optical centers with very similar radiative decay rates. The energy level schemes of those centers have been determined on the basis of optical absorption, luminescence and Raman experiments. Crystal field fitting resulted in two sets of slightly different crystal field parameters for two non-equivalent Yb centers. Both sets of parameters describe perfectly the experimentally detected Y b3+ energy levels. Correlation between systematic trends in the experimental energy level schemes and crystal field parameters is discussed.
This paper quantifies the avoided CO{sub 2} emission due to the using, as vehicle fuel, of the alcohol produced in Brazil during the period 1995 - 2025. With this purpose, internal demand sceneries were elaborated for Otto cycle engines. The results suggest that the introduction of the flex-fuel and the increasing of the production and using of hydrated alcohol can reduce up to 1.23 Gt of CO{sub 2} equivalent during the period 2003 - 2025, representing an annual average of 53.5 Mt CO{sub 2} equivalent.
Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of {sup 226}Ra and {sup 232}Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)
Measurements are presented of indoor radon levels made in a prototype house constructed partly of bauxite waste (red mud) and partly of conventional materials. The mud used contains higher than the average amounts of "2"2"6Ra and "2"3"2Th found in local building materials. The rates of exhalation of radon from the material used in the construction of the house are measured and employed with measured air change rates to make estimates of the average contribution of the various materials to the measured radon levels indoors. There is fairly good agreement between the two. The increment of radon related dose equivalents above background are also estimated and these are combined with previously determined gamma dose equivalents and used as a basis for assessing the acceptability of the practice of using red mud as a building material. (author)
Shaping has proven to be a powerful but precarious means of improving reinforcement learning performance. Ng, Harada, and Russell (1999) proposed the potential-based shaping algorithm for adding shaping rewards in a way that guarantees the learner will learn optimal behavior. In this note, we prove certain similarities between this shaping algorithm and the initialization step required for several reinforcement learning algorithms. More specifically, we prove that a reinforcement learner with initial Q-values based on the shaping algorithm's potential function make the same updates throughout learning as a learner receiving potential-based shaping rewards. We further prove that under a broad category of policies, the behavior of these two learners are indistinguishable. The comparison provides intuition on the theoretical properties of the shaping algorithm as well as a suggestion for a simpler method for capturing the algorithm's benefit. In addition, the ...
Although infrared-stimulated luminescence (IRSL) signals in feldspars can be bleached rapidly by sunlight, there could still be a small amount of IRSL signal remaining in sediment grains if they have experienced only relatively short sunlight exposure before deposition. This remaining signal results in a ''remnant dose'' stored in the grain and is important for young samples but negligible for old samples. Several methods have been introduced to detect insufficient bleaching, and some of them can provide information on the extent of the bleaching. Others can only distinguish between samples bleached for a very long time and for a short time. Empirical methods are introduced to evaluate the possible values of equivalent dose accumulated since the grains were deposited. These methods involve the analysis of the equivalent doses and the natural IRSL signals obtained using single-disc dose determination methods. (author).
This work aimed to develop a fast-dissolving film made of low dextrose equivalent maltodextrins (MDX) containing nicotine hydrogen tartrate salt (NHT). Particular attention was given to the selection of the suitable taste-masking agent (TMA) and the characterisation of the ductility and flexibility under different mechanical stresses. MDX with two different dextrose equivalents (DEs), namely DE 6 and DE 12, were selected in order to evaluate the effect of polymer molecular weight on film tensile properties. The bitterness and astringency intensity of NHT and the suppression effect of several TMA were evaluated by a Taste-Sensing System. The films were characterised in term of NHT content, tensile properties, disintegration time and drug dissolution test. As expected, placebo films made of ...
The MCNPE-BO and MCNP4 Monte Carlo electron-photon codes were used to calculate the dose equivalent per unit fluence at various depths in tissue-equivalent slab phantoms for broad parallel beams of monoenergetic electrons with energies from 50 keV to 10 MeV. The study was carried out in the framework of the activities of a ICRP/ICRU Joint Task Group with the support of EURADOS WG4 (Numerical Dosimetry). Some preliminary results and comparisons as well as a general discussion on the performances of the codes are presented, demonstrating quite a satisfactory agreement among the results obtained using the two codes and those of other authors. (author).
This paper presents a procedure for transferring the CTOD fracture toughness obtained from laboratory specimens to an equivalent CTOD for structural components, taking constraint loss into account. The Weibull stress criterion is applied to correct the CTOD for constraint loss, which leads to an equivalent CTOD ratio, b, defined as b=d/dWP, where d and dWP are CTODs of the standard fracture toughness specimen and the structural component, respectively, at the same level of the Weibull stress. The CTOD ratio b is intended to apply to the fracture assessment of ferritic steel components to stress levels beyond small-scale yielding. Nomographs are given to determine the b-value as a function of the crack type and size in the component, the yield-to-tensile ratio of the material and the Weibul...
Processing of symbolic sequences represented by mapping of symbolic data into numerical signals is commonly used in various applications. It is a particularly popular approach in genomic and proteomic sequence analysis. Numerous mappings of symbolic sequences have been proposed for various applications. It is unclear however whether the processing of symbolic data provides an artifact of the numerical mapping or is an inherent property of the symbolic data. This issue has been long ignored in the engineering and scientific literature. It is possible that many of the results obtained in symbolic signal processing could be a byproduct of the mapping and might not shed any light on the underlying properties embedded in the data. Moreover, in many applications, conflicting conclusions may arise due to the choice of the mapping used for numerical representation of symbolic data. In this paper, we present a novel framework for the analysis of the equivalence of the ...
The low-cycle fatigue behaviour of copper and a-brass CuZn30 was investigated in uniaxial and biaxial tests. Planar biaxial fatigue tests were carried out using cruciform samples with proportional stain paths with and without phase shift between the two axes. Microcharacterisation was performed by electron microscopy as well as by high-resolution X-ray line profile analysis. The biaxial cyclic stress-strain curves show good agreement with the uniaxial ones using the von Mises equivalent strain hypothesis. The dislocation densities and microhardness values of the biaxial case, however, show significantly lower values compared to the uniaxial case at equivalent von Mises stresses.
One of the unsolved problems of the natural gas dual fuel engine is that there is too much exhaust of Total Hydrogen Carbon(THC) at a low equivalent mixture ratio. To fix it, a natural gas mixed with hydrogen was applied to engine test. The results showed that the higher the mixture ratio of hydrogen to natural gas, the higher the combustion efficiency. And when the amount of the intake air is reached to 90% of WOT, the combustion efficiency was promoted. But, like a case making the injection timing earlier, the equivalent mixture ratio for the nocking limit decreases and the produce of NOx increases. 5 refs., 9 figs., 1 tab.
The present study was designed to determine the exercise intensity equivalent to the metabolic aerobic/anaerobic transition of alloxan diabetic rats, through lactate minimum test (LMT), and to evaluate the effects of swimming exercise at this intensity (LM) on the glucose and protein metabolism of these animals. Adult male Wistar rats received alloxan (SD, alloxan-injected rats that remained sedentary) intravenously (30 mg kg?1 body weight) for diabetes induction. As controls (SC, vehicle-injected rats that remained sedentary), vehicle-injected rats were utilized. Two weeks later, the animals were submitted to oral glucose tolerance test (oGTT) and LMT. After the tests, some of the animals were submitted to swimming exercise training [TC (vehicle-injected rats that performed a 6-week exerc...
Radon concentration measurements were performed for one year in 12 different boron, chromium and coal underground mines in Western Turkey. Lucas cells and nuclear track detectors were used for the measurements of radon and its decay products. The effects of parameters, such as type of mine, gallery depth and ventilation rate, on the radon concentration in mine air were examined. The radiation exposure doses of miners due to the inhalation of radon and radon daughters were determined. Gamma survey measurements were also realized together with radon measurements and the total effective dose equivalents in mSv y{sup -1} were estimated.
Much attention is being paid to electric vehicles from environmental standpoints. One disadvantage of the electric vehicle is that its operative range is short. A means to overcome this difficulty is to use a hybrid battery which consist of a energy battery and a power battery. A method to make it possible to calculate the discharge characteristics of the battery hybrid system taking into account the charging behavior from the energy battery to the power battery is presented. In the proposed method, first the output voltage and the output current of an equivalent battery, which is required for realizing the given operating pattern are calculated. Next, the conduction ratio of the main chopper and the equivalent discharge of electric charge of each battery are calculated. These calculated data are used to calculate the operating range.
Delayed neutron energy spectra have been measured for six delay-time intervals following the fast fission of "2"3"8U nuclei. The delay-time intervals span the range 0.17 to 10.2 seconds following initial fission while the measured spectra span neutron energies from 10 keV to 4 MeV. The experiment was performed utilizing the UMass/Lowell 5.5 MV Van de Graff accelerator to produce fast neutrons for inducing fission in a "2"3"8U lined fission chamber. The fission fragments were flushed via a helium jet stream to a well-shielded counting room where they were deposited onto a moving tape (magnetic audio tape) and transferred to a beta-neutron time-of-flight spectrometer. By adjusting the tape speed, composite delayed neutron time-of-flight spectra were measured for several different delay-time intervals. These measurements involved beta-neutron coincidences with ...
Full text: The principal nuclear design tools available to the shielding designer include diffusion approximation, transport theory, and Monte Carlo techniques. Full transport theory or Monte Carlo methods are routinely used for shielding analyses, where penetration investigations are more sensitive to directional aspects. However, the aim of this paper is to illustrate the coupled neutron-gamma Albedo method particularly as applied to problems of shielding analysis. The multigroup Albedo method is applied to coupled neutron-gamma radiations considering 'n' neutron energy groups and 'g' gamma energy groups to estimate the probabilities of transmission through, absorption in, and reflection from shieldings composed by multiple material layers, 'm' slabs, in which no fission occurs. In this study, these energy groups were selected in order to minimize upscattering effects of the radiation from lower energy groups to higher ...
In this report, we outline the progress achieved in two distinct under the DOE-sponsored cross section project: the initial results obtained from the pulsed 14 MeV neutron facility, and a cooperative effort with Argonne National Laboratory in the measurement of fast neutron cross sections in yttrium. In the 14 MeV neutron laboratory, this year has seen the maturation of the project into one in which initial scattering measurements are now underway. We have improved the accelerator and ion source in several significant ways, so that neutron intensities have now been proven to be adequate for our series of elastic scattering angular distribution measurements outlined in our initial proposal of two years ago. We have successfully tested all components of the time-of-flight spectrometer and recorded initial neutron spectra from the ring targets that we have obtained for our first ...
The structure of polydispersed populations of unilamellar vesicles is studied by small-angle neutron scattering for three types of lipid systems, namely, single-, two-and four-component vesicular systems. Results of the numerical analysis based on the separated-form-factor model are reported.
The effect of nuclear scattering on the suprathermal fusion probability of recoiling d-t nuclei under the impact of fusion products, a 14.1-MeVneutron and a 3.5 MeV alpha particle, in thick pellets is investigated with the help of the Boltzmann-Fokker-Planck equation. Although the suprathermal fusion from alpha-particle recoils is quite small, the one originating from neutron recoils is considerable.
We have developed a set of modeled nuclear reaction cross sections for use in radiochemical diagnostics. Systematics for the input parameters required by the Hauser-Feshbach statistical model were developed and used to calculate neutron induced nuclear reaction cross sections for targets ranging from osmium (Z = 76) to gold (Z = 79). Of particular interest are the cross sections on Ir and Au including reactions on isomeric targets.
We have performed precision measurements in a magneto-optical trap of the 7P1/2 hyperfine structure of the isotopes 209-210Fr. The ratio of these hyperfine constants to the previously measured 7S1/2 ground state values reveals a significant hyperfine anomaly. This anomaly results from the different radial dependence of the electron density in the two atomic levels. The measurements are sensitive to changes in the radial distribution of the neutron magnetism.
Water transport in the ionomeric membrane, typically Nafion{reg_sign}, has profound influence on the performance of the polymer electrolyte fuel cell, in terms of internal resistance and overall water balance. In this work, high resolution neutron imaging of the Nafion{reg_sign} membrane is presented in order to measure water content and through-plane gradients in situ under disparate temperature and humidification conditions.
We present a study of the crystal field in PrNiAl, NdNiAl, ErNiAl and ErCuAl intermetallic compounds based on inelastic neutron spectroscopy. These compounds crystallize in the ZrNiAl-type hexagonal structure with an orthorhombic symmetry on rare-earth sites. The results are compared with the specific-heat data, and the lower parts of the crystal-field energy-level schemes are determined. (orig.)
We present a study of the crystal field in PrNiAl, NdNiAl, ErNiAl and ErCuAl intermetallic compounds based on inelastic neutron spectroscopy. These compounds crystallize in the ZrNiAl-type hexagonal structure with an orthorhombic symmetry on rare-earth sites. The results are compared with the specific-heat data, and the lower parts of the crystal-field energy-level schemes are determined. (orig.)
A new software for neutron activation analysis was designed, built and implemented on a desktop computer using Visual Basic 6.0 program. The construction of this data analyzer computer program is described. The new software deals with peak reports resulting from Gammaplus software with minimum interference from the user in order to save time, manpower and minimize human errors. Its ability to find the concentrations of chemical elements within samples is proven to be fast, reliable and user friendly. (author)
Results on defect structure study and degree of molybdenum radiation hardening irradiated by fission neutrons and medium energy alpha-particles are presented. It is shown that molybdenum irradiation by alpha-particles and neutrons leads to different degree of material hardening for the same damage level. It is established that molybdenum radiation hardening is mainly defined by radiation defect clusters visible in electron microscope whose coefficient of rigidity depends on their size. 5 refs.; 6 figs.; 2 tabs. (author).
The ..beta.. decay half-lives of neutron-rich isotopes with Z=24-28 are calculated in the QRPA with a Gamow-Teller residual interaction. For odd-mass and odd-odd systems QRPA phonon correlations are introduced to quasiparticle transitions in first-order perturbation. The calculated half-lives agree very well with the experimental values. For later application of this model to nuclei far from stability, we have examined the dependence of the calculated half-lives on the model parameters.
The #beta# decay half-lives of neutron-rich isotopes with Z=24-28 are calculated in the QRPA with a Gamow-Teller residual interaction. For odd-mass and odd-odd systems QRPA phonon correlations are introduced to quasiparticle transitions in first-order perturbation. The calculated half-lives agree very well with the experimental values. For later application of this model to nuclei far from stability, we have examined the dependence of the calculated half-lives on the model parameters. (orig.).
The Monte Carlo transport codes LAHET and MCNP were used to calculate energy fluence spectra at three neutron therapy facilities. The results compare very favourably with measured data. Kerma spectra and the ratio of ICRU muscle tissue kerma to A-150 kerma, along the carbon to oxygen kerma ratio, were determined. Absorbed dose rate calculations are in reasonable agreement with measured values. Use of these codes to study modifications to existing therapy beams is briefly discussed. (author).